CS Paper Radar

FESTiVE: Self-calibrated Spatial-temporal Gradient Characterization for Non-cartesian Imaging on High Performance Systems

Zachary Shah, Daniel R. Abraham, Nan Wang, Xiaozhi Cao, Qiang Liu, Lipeng Ning, Yogesh Rathi, Nastaren Abad, Seungkyun Lee, Eric Fiveland, Afis Ajala, Thomas Foo, Adam B. Kerr, Kawin Setsompop

eess.SP ·submitted 2026-10-30 23:57 UTC · v2

Abstract

Gradient imperfections disrupt the encoding benefits of long-readout imaging applications on high-performance systems. Currently, external field monitoring hardware provides the only reliable solution for general spatial-temporal gradient characterization. We present FESTiVE, a data-driven alternative to higher-order field monitoring. FESTiVE leverages parallel imaging to both implicitly model and explicitly recover field imperfections. Using a fast k-t mapping calibration scan, FESTiVE formulates a time-varying GRAPPA problem which maps k-space data corrupted by a time-varying gradient imperfection against a clean reference. This mapping is represented compactly with an implicit neural representation, from which the spatial-temporal fields are recovered in image space using coil sensitivities. In phantom, FESTiVE produces comparable field measurements to a Skope field camera across multiple non-cartesian 2D acquisition strategies and gradient specifications. In vivo, FESTiVE achieves state-of-the-art image quality for a high-performance diffusion spiral protocol on the head-only MAGNUS 3T, where higher-order phase imperfections are significant. At 7T, on the head-only Siemens TerraX system, FESTiVE enables 300μm spiral imaging where conventional field camera-based approaches fall below probe dephasing limits. In conclusion, FESTiVE enables robust high-resolution non-cartesian imaging on high-performance gradients, characterizing gradient imperfections using parallel imaging rather than field monitoring hardware.

Closest papers

Nearest neighbours by meaning across the whole index.

Measurement-Adaptive Light-Cone Transform for Robust Non-Line-of-Sight Imaging

eess.IV cs.CV ·2026-10-16 ·Lianfang Wang, Xueying Liu, Junnan Dong, Qinghua Zhang, Jun Liu +2 more
published similarity 0.58
Abstract

Practical non-line-of-sight (NLOS) measurements are affected by noise and deviations from idealized light transport, which can degrade reconstruction with conventional light-cone transform (LCT) methods. We propose the Measurement-Adaptive Light-Cone Transform (MALCT), a physics-guided framework that retains the efficient Fourier-domain inversion structure of LCT. {Within a unified variational formulation, MALCT combines the analytical response with a shared learned response through measurement-conditioned weighting and predicts a measurement-conditioned, frequency-dependent regularization map.} An attention-enhanced spatio-temporal feature extraction module captures long-range temporal dependencies and local spatial correlations to support reconstruction under low-signal conditions. Experiments on synthetic data and real measurements from different NLOS systems demonstrate improved reconstruction quality. Controlled evaluations further assess robustness to temporal-response broadening and reduced acquisition time. MALCT also preserves scene structures with spatial sampling grids down to $32\times32$, supporting its potential for NLOS imaging under limited acquisition budgets.

0.35

Directional Total Variation-Regularized Implicit Neural Representations (DTV-INR) for Continuous Super-Resolution in Degraded Imaging Domains

cs.CV ·2026-09-21 ·Mahmoud Saeedi Kelishami
similarity 0.58
Abstract · 18 pages, 8 figures, 3 tables

In this paper, we introduce the Directional Total Variation-Regularized Implicit Neural Representation (DTV-INR), an advanced variational paradigm that synergistically integrates coordinate-driven implicit neural networks with an anisotropic, structure-tensor-informed total variation regularizer tailored for resolution-agnostic image super-resolution. Casting the continuous-to-discrete acquisition process into an ill-posed inverse problem framework, our formulation equips a SIREN-architected coordinate network with a dynamic Riemannian metric tensor field D(x). By leveraging its spectral decomposition, the proposed regularizer preferentially directs diffusion parallel to dominant structural contours while penalizing cross-edge dissipation, successfully circumventing the classical staircasing artifacts inherent to scalar total variation schemes. We rigorously prove the well-posedness of this formulation in H^1(Omega) by establishing the existence, uniqueness, and metric stability of the variational minimizer, and realize this via an alternating projected optimization algorithm that decouples network parameter tuning from adaptive tensor field updates. Comprehensive experiments conducted on clinical brain magnetic resonance imaging (MRI) and biomedical transmission electron microscopy confirm substantial quantitative and qualitative improvements, yielding PSNR enhancements reaching +5.05 dB over baseline unregularized INRs and +1.71-2.85 dB over isotropic TV-INR across continuous (non-integer) upsampling factors, alongside remarkable noise robustness up to sigma_eta = 0.10 and monotonic preconditioned convergence behavior.

0.33

OpenMASC: An Open-Source Pipeline for Cross-Trajectory Metal-Aware Sampling and Correction in Accelerated MRI

cs.CV ·2026-09-26 ·Zhengyi Lu, Ming Lu, Chongyu Qu, Junchao Zhu, Junlin Guo +9 more
code/data similarity 0.57
Abstract

Metal implants corrupt MRI measurements throughout $k$-space, yet existing accelerated MRI methods assume clean data and most metal artifact reduction approaches assume fully sampled acquisitions. No public dataset provides paired $k$-space and images with and without metal for the same anatomy, and no framework jointly addresses artifact-aware acquisition and reconstruction across sampling trajectories. We present OpenMASC, an open-source pipeline covering the full workflow from data generation to deployment. A physics-based data generation module converts public CT volumes into paired clean and metal-corrupted MRI data in both Cartesian and radial formats. MA-VarNet, an unrolled reconstruction network with a per-cascade DC Rectifier, corrects artifacts that data-consistency steps reintroduce from corrupted measurements. A reinforcement learning agent actively selects $k$-space readouts and co-trains with the reconstruction network through a decoupled three-stage procedure. The framework is trajectory-agnostic except for the data-consistency operator, supporting both Cartesian and radial acquisition without architectural changes. Experiments on two datasets at $4\times$ and $8\times$ acceleration demonstrate consistent improvements over conventional and learned baselines on both trajectories.

0.31

UMPIRE-Net: Unrolled Magnitude-Phase Regularization Network for Accelerated MRI

eess.IV cs.CVeess.SPphysics.med-ph ·2026-08-14 ·Mahdi Saberi, Toygan Kiliç, Mehmet Akçakaya
code/data similarity 0.56
Abstract · IEEE International Workshop on Machine Learning for Signal Processing (MLSP)

MRI reconstruction from undersampled k-space measurements is an ill-posed inverse problem. Physics-driven deep learning (PD-DL) methods have shown strong performance for this task by combining the MRI forward model with learned image regularization within algorithm-unrolling frameworks. However, most existing PD-DL methods reconstruct complex-valued images directly, thereby implicitly coupling magnitude and phase within a single learned representation. This coupled regularization may be suboptimal in reconstruction settings where accurate phase modeling plays an important role, such as partial Fourier (PF) imaging, where recovery of the omitted asymmetric k-space measurements depends on the underlying image phase. In such scenarios, explicit modeling of magnitude and phase as separate components may reduce the reliance on externally estimated or predefined phase information. To this end, we propose UMPIRE-Net (Unrolled Magnitude-Phase In REgularization Network), a PD-DL method that introduces separate learned regularizers for magnitude and phase components, together with a novel data-fidelity formulation that enforces measurements consistency. We evaluate UMPIRE-Net for accelerated MRI with PF across different datasets and acceleration factors. Experimental results demonstrate that our proposed method improves reconstruction quality compared with a conventional complex-valued PD-DL baseline, yielding sharper images and reduced artifacts. Code available at: https://github.com/MahdiSaberii/UMPIRE-Net

0.59

FIRM: Flow-based Imaging via Regularized Minimization

cs.CV ·2026-09-11 ·Shirin Shoushtari, Edward P. Chandler, Xiao Shi, Ulugbek S. Kamilov
similarity 0.56
Abstract

Flow matching methods for imaging inverse problems typically incorporate measurements through network conditioning or guidance during sampling. Neither approach explicitly applies the forward operator within the learned conditional velocity field. We develop a principled measurement-conditional velocity parameterization that does. For a linear interpolation path, we express the optimal velocity through the posterior mean $E[x_1|x_t, y]$ and show that this mean is the unique minimizer of a variational objective with an explicit data-consistency term. The velocity defined by this minimizer provably transports the source distribution to the measurement-conditioned posterior. This result leads to a forward operator-aware velocity field that is trained end-to-end and requires no separate guidance during sampling. Across five imaging tasks, our method achieves leading reconstruction quality with up to $50\times$ fewer network evaluations than competitive flow-based methods. Varying the number of sampling steps also controls the distortion-perception trade-off without retraining.

0.17

Spectrally optimized implicit neural representations mitigate acquisition-related image quality trade-offs in intracranial 4D Flow MRI

eess.IV cs.CV ·2026-10-23 ·Oliver Welin Odeback, Nerea González-Aranceta, Sebastián Jofre, Javier Bisbal, Edward Ferdian +10 more
similarity 0.56
Abstract · 36 pages, 7 main figures, 2 supplementary figures. Under review at Medical Image Analysis

4D Flow MRI promises opportunities for non-invasive mapping of neurovascular hemodynamics, but its clinical utility faces trade-offs between resolution, acquisition time, and noise. Deep learning-based super-resolution offers a post-scan solution, but supervised approaches require paired or domain-specific data, while patient-specific physics-informed models can be computationally demanding. This creates a need for unsupervised reconstruction models that can adapt to individual acquisitions without paired high-resolution training data, while remaining robust across anatomy, disease severity, and acquisition quality. To address this, we introduce a spectrally tuned implicit neural representation (INR) framework for intracranial 4D Flow MRI, representing the velocity field as a continuous coordinate-based neural field using WIRE activation functions with tunable spectral bias. Data-driven and physics-informed variants were evaluated in nine cerebrovascular cases spanning healthy controls and moderate-to-severe intracranial atherosclerotic disease, using CFD-derived high-resolution reference fields, MR-realistic synthetic low-resolution inputs, and direct fitting to acquired in-vivo data. Cohort-optimal spectral-bias settings generalized across subjects with only small increases in relative error compared with subject-specific optima, reducing the need for case-specific hyperparameter tuning. Physics-informed regularization provided modest additional accuracy but required substantially longer optimization, whereas the data-driven INR achieved near-comparable reconstruction performance within minutes. The framework also remained robust to acquisition-realistic noise and moderate VENC-dependent aliasing. These findings establish spectrally optimized INRs as a flexible unsupervised approach for mitigating acquisition-related trade-offs in intracranial 4D Flow MRI.

0.21

LGGS: Longitudinal MRI Reconstruction via Guided Group Sparsity

eess.IV cs.CV ·2026-10-15 ·Nikola Janjušević, Hersh Chandarana, Yao Wang, Li Feng
similarity 0.56
Abstract · 10 pages main, 8 figures main, 5 pages supplementary, 7 figures supplementary

Serial MRI is routinely performed in current clinical practice for disease surveillance and applications such as MR-guided radiotherapy. However, long MRI scan times increase costs and limit patient access, making accelerated image reconstruction of broad clinical importance. Previous scans of the same patient contain image information highly correlated with the current exam, yet existing reconstruction methods rarely exploit this information. Major challenges in the effective use of prior scans include inter-visit misregistration, pathological changes, and image phase variation. In this work, we propose Longitudinal Guided Group Sparsity (LGGS), an interpretable deep-learning framework for longitudinally informed MRI reconstruction derived from classical group sparsity. The prior scan is incorporated into the reconstruction regularizer through learned phase-invariant circulant attention that identifies corresponding features across exams. This formulation provides robustness to local in-plane and through-plane misregistration as well as inter-visit phase variation. Across acceleration rates, LGGS achieves state-of-the-art performance on longitudinal T1-weighted multi-coil brain MRI data, outperforming the evaluated unguided and longitudinally informed reconstruction methods, with substantially fewer learned parameters. We further evaluated the contributions of multiple guide slices and phase-invariant similarity and demonstrated that accelerated prior images can also serve as effective guides with minimal degradation in reconstruction quality.

0.21

Image Fidelity is Not Field Fidelity: Joint Thermodynamic Reconstruction and Error Localization in Neural Tomography

cs.LG astro-ph.IMastro-ph.SR ·2026-09-24 ·Alan Hsu, Jenna Samra, Alin Razvan Paraschiv, Liam Connor
similarity 0.56
Abstract

Neural fields for scientific tomography are optimized from 2D images, but the actual quantity of interest is often a latent 3D physical field. Because the forward map is many-to-one, low 2D image error need not certify a correct 3D field. Moreover, the latent field is not directly supervised during training, and its error cannot be evaluated against truth at deployment. We develop CoroNeRF to jointly optimize 3D electron density and temperature fields directly from multiview, multiline intensities through a differentiable atomic-emission renderer. Using solar coronal tomography as a controlled testbed, we evaluate physical-field recovery and test whether cross-seed instability provides a ground-truth-free-at-inference indicator of local physical-field error. We underscore the following two observations. (i) Image fidelity is not field fidelity: spectral ablations show that limited-channel reconstructions can fit their available observations well while recovering substantially worse fields, whereas evaluation on a common richer probe exposes the discrepancy. (ii) Cross-seed instability ranks local physical-field error across tested matched-model conditions, supported by sparsification and physical signal-strength controls. Seed-deviation projections provide complementary directional validation, but shared forward-model mismatch can still produce incorrect cross-seed consensus. These results characterize joint thermodynamic recovery and the usefulness and limits of seed-based error localization in a controlled, single-scene solar tomography testbed.

0.30