CS Paper Radar

Daily listing

2026-11-09 · eess.IV

10 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 9

MRFoundry: Knowledge-guided agent loops for end-to-end MRI research

eess.IV cs.AI ·2026-11-09 ·Ke Wang, Atakan Topcu, Hossein Momeni, Molin Zhang
code/data
Abstract · 18 pages, including 6 pages of Supporting Information. Code: https://github.com/KeWang0622/MRFoundry

AI agents can write code, use scientific software, and revise computational workflows, opening new possibilities for MRI research. Effective assistance requires connecting acquisition physics, data conventions, specialized tools, and scientific validation. We present MRFoundry, an open-source, extensible package that connects MRI knowledge to agent actions and output checks. Project-local memory preserves decisions and evidence, while reviewed contributions allow researchers to improve shared guidance. Researcher-supervised examples demonstrate skill-guided sequence auditing and acquired-data reconstruction, connecting tool use, output checks, and documented decisions. Alongside MRFoundry, we introduce MRI Agent Bench to compare agents with and without the package across models and MRI task domains. Across 240 paired Core evaluations spanning 24 task types and ten models, all-checks-passed completion increased from 67.5% without MRFoundry to 78.3% with it. Across 134 Hard pairs, completion increased from 36.6% to 44.8%. MRFoundry makes MRI workflow expertise available as reusable guidance that researchers can inspect, adapt, and extend within existing agent and scientific software environments. MRFoundry is openly available at https://github.com/KeWang0622/MRFoundry.

0.41

Is a CNN-Transformer Ensemble Worth It When a Chest X-Ray Foundation Model Is Available?

eess.IV cs.CV ·2026-11-09 ·Aditya Seelaboyina, Irfan Khan
code/datahot direction
Abstract · 8 pages, 2 figures, 10 tables. Code: https://github.com/adityaseelaboyina/cxr-ensemble-vs-foundation-model

Ensembles of ImageNet-pretrained convolutional networks and Vision Transformers are a common way to improve multi-label chest X-ray classification. We ask whether such an ensemble is still worth its cost when a model pretrained on chest radiographs is available. On the official patient-disjoint split of NIH ChestX-ray14 (25,596 test images, 2,797 patients), we train five ImageNet-pretrained backbones and the EVA-X-S foundation model with validation-only model selection, compare five fusion rules, and estimate every difference with a patient-level paired bootstrap. EVA-X-S alone reached a test macro-AUROC of 0.828; the five-model ensemble reached 0.814 (difference -0.0136, 95% CI -0.0178 to -0.0098) at about 7.8 times the summed backbone latency and ten times the parameters. Averaging the five ImageNet models with EVA-X-S changed AUROC by -0.0056 (-0.0095 to -0.0021). With all five ImageNet backbones trained with the EVA-X-S recipe, their ensemble scored 0.817, still -0.0109 (-0.0142 to -0.0076) below EVA-X-S, and across three seeds EVA-X-S varied by at most 0.001 AUROC. Under the ImageNet models' recipe, however, EVA-X-S fell to 0.798. Our full-stacking configuration never outperformed calibrated averaging. In this setting, the tested ImageNet ensembles did not improve on a single chest X-ray foundation model fine-tuned with its own recipe.

0.38

Image Quality and the Reliability of Fabric-Density Measurement: Counting Threads from Smartphone Photos Through a Pick Glass

cs.CV eess.IV ·2026-11-09 ·Anoubhav Agarwaal
publishedbenchmark
Abstract · Accepted at the WVAQ workshop at WACV 2027

Thread density, the threads per inch along and across a woven fabric, is a basic specification that buyers check whenever fabric is sold. Without laboratory instruments, inspectors count it slowly, by eye, through a pick glass, a folding 10$\times$ magnifier with a one-inch window. A smartphone photo through that glass could make the check faster and leave a record. We judge such a photo by what it is used for, as in task-based image quality: it is good if the thread count from it is within $\pm$5% of the true count, a common tolerance in fabric specifications. We introduce PickGlass-TPI: 76 factory scenes of 44 fabric patches, each counted in an open annotation tool by a textile-trained annotator, whose counts are the reference. On it we benchmark frontier and open vision-language models, CNNs, counting specialists and a training-free spectral counter (PG-Lattice). No method agrees with the reference within the tolerance. The best methods are off by about a quarter: a small open model that we tuned only on synthetic images (Molmo2-4B, 25%) is level with the best frontier model, GPT-6.1-sol (27% when asked directly, 25% given four magnified close-ups of the window). Both err less than a non-expert annotator (37%), but only the tuned model also beats, on both error measures, a baseline that guesses each scene's density as the average of the others. PG-Lattice most often repeats its count within 5% across two photos of the same patch, but its misses, like GPT-6.1-sol's errors, are often a factor of two. Even the reference repeats a count across such re-shoots only to a median 9%, so one photo cannot yet be shown to meet $\pm$5%; the image quality that matters is reliability across re-shoots. Generic no-reference quality scores chosen before labeling do not rank PG-Lattice's error, and generative enhancement raises perceptual scores but does not reliably improve the count.

0.35

Artifact Filtering versus Artifact-Compensated Training in JPEG to JPEG AI Recompression

eess.IV cs.MM ·2026-11-09 ·Igor Podtsepko, Yuriy Kim, Karam Mahfod, Evgeny Belyaev, Kristian Kirs +2 more
Abstract · Preprint. Submitted to IEEE Multimedia on 21 February 2026. This is the author's draft version; it has not undergone peer review. 15 pages, …

In this paper, we consider the problem of recompression of images from JPEG to JPEG AI format. We show that direct recompression from JPEG to JPEG~AI trained on uncompressed images is accompanied by the preservation of the JPEG image artifacts in the resulting JPEG~AI image. In order to avoid it, we evaluate an approach where an artifacts removal neural network is first applied to the input JPEG image as an external pre-filter. However, in this case, the processing time is increased by 29 times. Therefore, we propose an artifact-compensated training for JPEG AI and show that it is able to combine pre-filtering against target distortions with efficient compression without increase in the processing time.

0.33

A four-step validation protocol for radiomic survival analysis in small cohorts: a body composition case study

eess.IV cs.CVcs.LG ·2026-11-09 ·Mariela Talavera-Muñoz, Cecilia Diana-Albelda, Miguel Antonio Sampedro-Nuñez, Victor Rodriguez-Laval, Jesus Bescos +1 more
code/data
Abstract

Gastroenteropancreatic neuroendocrine tumors (GEP-NET) lack prognostic biomarkers, and computed tomography (CT)-based body composition radiomics at the third lumbar vertebra (L3) is a promising candidate. Small cohorts make high-dimensional radiomic models prone to overfitting and single-split evaluations variable and optimistic. This methodological study proposes a four-step validation protocol for radiomic survival analysis in small cohorts: (1) false discovery rate (FDR)-corrected feature selection, (2) a dual-path comparison of prior feature selection versus embedded regularization, (3) repeated nested cross-validation (CV) and (4) a negative control with Gaussian noise features. In 78 GEP-NET patients, 535 radiomic features from five L3 compartments were used to evaluate five survival models with Harrell's concordance index (C-index), time-dependent area under the curve (AUC) and integrated Brier score (IBS). Step 1 selected at least one feature in 18% of outer folds under noise (nominal level 20%) versus 84% with radiomic features. The dual-path comparison showed no consistent difference between strategies. Repeated nested CV reduced variability across seeds (41% median reduction in C-index standard deviation), but not enough to distinguish models. The nested CV C-index exceeded chance by 0.07-0.15 with radiomic features but not clearly under noise (0.40-0.42 with prior feature selection, 0.47-0.55 with embedded regularization). Frequently selected features tentatively linked greater subcutaneous fat, skeletal muscle compactness and texture to better prognosis. These findings suggest a modest prognostic signal in L3 radiomics, with considerable uncertainty that the protocol quantifies. The protocol may transfer to other small-cohort radiomic survival studies. Code: https://github.com/marielatalaveram/radiomics-survival-validation-protocol.

0.30

SNIF: a Self-Navigator Intelligent Filter correcting off-center and spin-history artifacts in quasi-random radial MRI

eess.IV ·2026-11-09 ·Tanguy Boucneau, Brice Fernandez, Peder Larson, Luc Darrasse, Xavier Ma{î}tre
unusual
Abstract · 10 pages, 6 figures; supplementary material (93 pages): DC-signal spectra for every reception channel

For self-navigation and self-gating in MRI, self-navigators are extracted from the complex values of the k-space center, called DC-signal, through a temporal frequency analysis. However, this signal often carries artifacts. This paper introduces a Self-Navigator Intelligent Filter (SNIF) that models the physical origin of the k-space center artifacts to properly estimate them and thus more accurately remove them. The artifact affecting the DC-signal $S_{DC}$ generally has two main origins: the jitter of the k-space center (''off-center artifact'') and the cumulative history of the spins (''spin-history artifact''). Both add noise-like artifacts to the signal. The off-center effect can be modeled as a perturbative signal $S_0$ and the spin-history effect as a convolution kernel $h$ so that the measured DC-signal is $S_{DC} = S_m + S_0 \star h$, where $S_m$ is the motion-related component which effectively contains the expected self-navigators. Methods to compute $h$ and $S_0$ were developed, which gives the possibility to extract $S_m$ from $S_{DC}$. They were implemented and evaluated on thoracic UTE datasets acquired on a healthy volunteer. Qualitative visual comparison and quantitative spectral analysis of the DC-signal before and after SNIF demonstrate that the method improves both the accuracy and the precision of the extracted respiratory and cardiac self-navigators. By considering the physical origin of the DC-signal artifacts, SNIF makes both respiratory and cardiac self-navigators more sensitive to motion, which supports finer MRI motion tracking.

0.27

Leveraging High-Activity Post-Therapeutic I-131 Scans for Deep Learning Reconstruction of Extremely Sparse Planar Images in Differentiated Thyroid Cancer

eess.IV cs.CVphysics.med-ph ·2026-11-09 ·Boyang Pan, Hang Yang, Jianchen Pan, Cui Gan, Lanxi Zhang +2 more
Abstract · 12 pages, 2 figures, 3 tables

Background: Diagnostic I-131 whole-body planar imaging in differentiated thyroid cancer (DTC) is count-limited by low administered activity, and quality worsens under rapid acquisition. Models trained on such data struggle because their targets lack photon statistics. Purpose: To test whether high-quality post-therapeutic (PT) I-131 scans can serve as superior training references for enhancing sparse diagnostic planar images, using transfer learning and input-image addition. Methods: In this single-center prospective study, 111 patients were enrolled in PT training (n = 19), diagnostic follow-up (FU) training (n = 58), and FU paired test (n = 34) cohorts. Five Restormer-based models were trained: FU_DLx2 on FU labels; PT_DLx2 transfer-learned on PT data; PT_DLx1+ and PT_DLx2+ with input-image addition; PT_DLx6 as a PT-only reference. Test-time processing used two-step denormalization and Poisson re-scaling to preserve noise statistics. Quality was assessed by PSNR, SSIM, and a blinded dual-reader evaluation of all 34 test-cohort patients. Results: PT_DLx2 achieved the highest PSNR (34.4 +/- 3.6 dB) and SSIM (0.81 +/- 0.07). PT_DLx1+ and PT_DLx2+ were comparable (33.8 and 33.3 dB; SSIM 0.80). FU_DLx2 ranked below the unprocessed fast scan (30.3 vs. 32.0 dB; 0.76 vs. 0.79). Subjectively, PT_DLx2+ scored highest in image quality (4.54 +/- 0.60) and diagnostic confidence (4.54 +/- 0.60), surpassing the reference standard (4.19 +/- 0.83 and 4.31 +/- 0.81; P = 0.005 and P = 0.008). FU_DLx2 and PT_DLx6 scored lowest. Conclusion: Count-rich PT scans provide effective training priors for reconstructing extremely sparse images. Input-image addition and cross-domain transfer learning from PT data outperformed direct training on count-limited diagnostic data, supporting 2x scan acceleration with quality matching or exceeding the unaccelerated standard scan for selected PT-derived configurations.

0.26

Differentiable Inverse Rendering Recovers Intrinsic Properties from Intravascular Optical Coherence Tomography

cs.CV eess.IVphysics.med-phphysics.optics ·2026-11-09 ·Ajay Manicka, Karim Kadry, Sebastian Ruiz-Lopera, Maryam Alsharqi, Sanjana Arji +5 more
Abstract · 27 Pages, 6 Figures, Under Review

Medical images encode intrinsic tissue properties that indicate disease progression, yet these properties remain entangled with the system-dependent physics of image formation. Differentiable inverse rendering asks whether they are recoverable by inverting the imaging system's forward physics rather than through post-hoc correction. We address this in optical coherence tomography (OCT), focusing on the optical attenuation coefficient, a per-pixel marker of pathology and cellular composition. Conventional recovery relies on closed-form inversions limited to simplified light-tissue models, or learned methods coupled to specific imaging configurations. We instead recover per-pixel attenuation from a single OCT image by gradient descent through a differentiable physics-based forward model. We verified the method against analytical solutions, validated it on five in vitro phantoms, and applied it without modification to 29{,}269 clinical intravascular OCT images from 128 patients. The inversion needs no training data or segmentations and is portable across platforms and retrospective archives. Replacing the forward model or recovering another optical parameter leaves the optimization procedure unchanged. We demonstrate per-pixel recovery is tractable because gradient information scales to this high-dimensional problem, where gradient-free methods become intractable. Our work supports quantitative tissue characterization from OCT images and provides a framework for extension across imaging modalities and organ systems.

0.26

Next-Generation Segmentation in Radiotherapy: A Narrative Review from Atlas-Based Methods to Agentic Vision-Language Models

eess.IV physics.med-ph ·2026-11-09 ·Josef A. Buchner, Richard Osuala, Ayhan Can Erdur, Melissa C. Olufs, Stephanie E. Combs +1 more
Abstract

Precise segmentation of target volumes and organs at risk is an essential prerequisite for modern, high-precision radiation therapy. However, this task has traditionally been time-consuming and subject to high interobserver variability. Motivated by these limitations, more advanced and novel approaches to automating this task have been developed over the past two decades. This narrative review highlights representative milestones, with a focus on the most recent developments. These approaches include atlas-based label propagation, convolutional architectures, promptable foundation models, and, most recently, vision-language models (VLMs), which integrate clinical text with volumetric segmentation. Each methodological generation has addressed limitations of its predecessor while introducing new ones. A substantial gap remains between research progress and clinical deployment, as routine workflows continue to be dominated by atlas-based and narrow task-specific deep-learning tools, which remain strong baselines in geometric overlap metrics but are highly rigid in terms of application, versatility, portability, and interpretability. As contouring systems further grow in complexity, conventional geometric overlap metrics become insufficient, motivating evaluation paradigms that incorporate surface-based, dosimetric, and prompt-adherence assessment. Emerging agentic architectures that combine large language models, retrieval-augmented generation, and vision-language segmentation modules are leading towards more flexible, guideline-aware, interactive contouring workflows. These systems could automate flexible and interpretable knowledge-based contouring and actively support the clinical reasoning underlying target volume definition.

0.10

Robotics, Control & Signals 1

STAR: Semantic-Criticality Tiered Allocation of Radio Resources via Zero-Shot Learning

eess.SP cs.AIeess.IV ·2026-11-09 ·Albert Shaju, Christo Kurisummoottil Thomas, Mingzhe Chen
Abstract · 6 pages, 9 figures, 1 table. Submitted to IEEE ICC 2027

In remote inference, edge devices transmit high-resolution images over wireless links to a receiver, where an artificial intelligence (AI) model answers task-specific questions about these images to enable reliable decisions. These answers are often determined by a small set of task-causal pixels, such as those of text, whose corruption changes the answer, so these pixels must be delivered with high fidelity. Conventional transmission protects every pixel equally, so it either consumes many resource elements (REs) or corrupts these regions at low signal-to-noise ratio (SNR). To overcome these limitations, in this paper, a zero-shot, domain-agnostic framework, termed semantic-criticality tiered allocation of resources (STAR), is proposed. In particular, a per-pixel semantic-criticality indicator (SCI) is derived from the attention of a frozen vision-language model, so new tasks and domains are handled by changing only the prompt, without retraining. The resulting task causality-aware resource allocation problem over protection tiers is solved exactly by a threshold rule on the SCI, realized by a coded tier for the task-causal pixels and an uncoded, downsampled base layer for the full image. Simulations over a 5G New Radio link demonstrate that STAR attains a semantic accuracy of at least 0.98 for $E_s/N_0 \geq -4$ dB and, at comparable semantic reliability, reduces the REs of robust coded transmission by 59.5% and 91.5% on factory- and vehicle-monitoring datasets, respectively, the latter without any change to the models. Although a deep joint source-channel coding baseline uses fewer REs at comparable semantic accuracy, it must be retrained with labeled data for every new task or domain.

0.16