SNIF: a Self-Navigator Intelligent Filter correcting off-center and spin-history artifacts in quasi-random radial MRI

Tanguy Boucneau, Brice Fernandez, Peder Larson, Luc Darrasse, Xavier Ma{î}tre

eess.IV ·submitted 2026-11-09 15:50 UTC · v1
unusual

Abstract

For self-navigation and self-gating in MRI, self-navigators are extracted from the complex values of the k-space center, called DC-signal, through a temporal frequency analysis. However, this signal often carries artifacts. This paper introduces a Self-Navigator Intelligent Filter (SNIF) that models the physical origin of the k-space center artifacts to properly estimate them and thus more accurately remove them. The artifact affecting the DC-signal $S_{DC}$ generally has two main origins: the jitter of the k-space center (''off-center artifact'') and the cumulative history of the spins (''spin-history artifact''). Both add noise-like artifacts to the signal. The off-center effect can be modeled as a perturbative signal $S_0$ and the spin-history effect as a convolution kernel $h$ so that the measured DC-signal is $S_{DC} = S_m + S_0 \star h$, where $S_m$ is the motion-related component which effectively contains the expected self-navigators. Methods to compute $h$ and $S_0$ were developed, which gives the possibility to extract $S_m$ from $S_{DC}$. They were implemented and evaluated on thoracic UTE datasets acquired on a healthy volunteer. Qualitative visual comparison and quantitative spectral analysis of the DC-signal before and after SNIF demonstrate that the method improves both the accuracy and the precision of the extracted respiratory and cardiac self-navigators. By considering the physical origin of the DC-signal artifacts, SNIF makes both respiratory and cardiac self-navigators more sensitive to motion, which supports finer MRI motion tracking.

Comment
10 pages, 6 figures; supplementary material (93 pages): DC-signal spectra for every reception channel

Closest papers

Nearest neighbours by meaning across the whole index.

High-Temporal-Resolution Motion Correction in Magnetic Resonance Fingerprinting Using a Quantitative Scout and Compact Spiral Navigators

eess.SP ·2026-09-21 ·Aizada Nurdinova, Xiaozhi Cao, Daniel R. Abraham, Daniel Polak, Nan Wang +4 more
similarity 0.54
Abstract

Motion correction in magnetic resonance fingerprinting (MRF) helps preserve the accuracy of quantitative maps; however, existing approaches provide motion updates only every 7-8 seconds. We propose a navigation framework that integrates compact k-space navigators throughout the MRF acquisition, enabling sub-second motion estimation at minimal sequence overhead. A 3D spiral-projection MRF sequence was augmented with three orthogonal spiral navigators inserted every 0.5 seconds, enabling motion estimation by comparing navigator signals with quantitative scout (Q-Scout) data, i.e., motion-free low-resolution k-space with matching contrast evolution. The Q-Scout is obtained via a rapid calibration during the dummy preparation period, incurring no additional scan time. Motion estimation is formulated as dictionary matching in a discriminant subspace with optimization refinement. The method was evaluated in simulation and in vivo for 1 mm isotropic brain 3D MRF at 3 T. Across 35 motion-corrupted acquisitions with motion-free references available, the proposed motion correction reduced MRF reconstruction normalized root-mean-square error (NRMSE) by 7.1% and increased the structural similarity index measure (SSIM) by 0.085. Motion estimates aligned with 8 second temporal-rate image-based navigation (mean absolute difference of 0.15 mm and 0.23 degrees), while the proposed method provided higher temporal resolution and improved motion correction. The proposed framework enables robust motion navigation in MRF at 0.5 second temporal resolution with minimal sequence overhead. By using contrast-consistent modeling and efficient inference, it improves the reliability of quantitative MRI under rapid, unpredictable motion.

0.23

Beyond MSE: Rician Likelihood Denoising for Self-Supervised Cardiac $T2$ and $T1ρ$ MRI

eess.IV cs.CV ·2026-09-24 ·Nicholas A. Jacobs, Jason Mendes, Ravi Ranjan, Edward DiBella, Shireen Elhabian
similarity 0.51
Abstract · Made minor spelling and punctuation corrections

Magnetic resonance imaging involves an inherent trade-off among spatial resolution, acquisition time, and noise. This trade-off contributes to long scan times and high cost. Deep learning has improved image denoising, but cardiac MRI remains difficult because high-resolution, rapid acquisitions generally lack corresponding low-noise ground truth. Self-supervised denoising offers a potential solution by learning from noisy image pairs or even single noisy acquisitions. However, we show that Noise2Void-style blind-spot denoising, which uses a mean squared error (MSE) loss and assumes zero-mean, independent and identically distributed (i.i.d.) noise, is poorly suited to MR magnitude images. When applied to short-axis $T2$-weighted and $T1ρ$-weighted cardiac MRI with synthetic Rician noise, it produces biased denoised images and biased parametric maps of $T2$ and $T1ρ$. To address this limitation, we formulate self-supervised denoising as maximum likelihood estimation under a known Rician noise model. This yields unbiased denoisers that are competitive with supervised baselines.

0.22

Effects of Sequence Timing on the Spatio-Temporal Properties of 3D BOLD fMRI: A Formal Framework and Analysis

eess.IV ·2026-09-17 ·Samuel Bianchi, Klaas P. Pruessmann
similarity 0.49
Abstract

3D sequences provide an alternative to 2D or multiband sequences for BOLD fMRI. The impact of acquisition time differences between slices is well understood for 2D or multiband sequences. For 3D sequences, k-space is partitioned into multiple segments and the final image depends on samples taken over an extended period of time. Any precise timing information is lost during reconstruction. A theoretical description of how sequence timing impacts 3D BOLD fMRI data properties is lacking in the literature. We present a formal framework that models sequence timing effects and draw connections to existing literature. The framework rests on the statistical description of a spin system that allows incorporation of BOLD signal changes and is completed by a general description of spatial encoding and image reconstruction. Using this formulation, we define three key images: the actual image reconstructed from a segmented 3D acquisition, an optimal reference image unaffected by sequence timing, and an error image representing their difference. Two sets of operators are defined that describe the generation of these images and allow us to analyse the effects of sequence timing independent of the object. All operators take the form of spatio-temporal filters. They mix signal content spatially and based on its temporal waveform. High-frequency BOLD signal content is affected more strongly compared to low-frequency content. Simulations demonstrate that while the total variance of 3D image time series can be reduced, spatio-temporal fidelity is increasingly lost. Furthermore, we hypothesize that the heightened sensitivity of 3D sequences to physiological noise (compared to 2D) is caused by sequence timing damping thermal noise more strongly than physiological fluctuations. The impact of motion and system instabilities on image time series needs to be studied further.

0.28

D-MOD: Diffusion mode estimation for accelerated MRI

cs.LG ·2026-10-29 ·Md Kawsar Ahmed, Mathews Jacob
theory similarity 0.48
Abstract

Diffusion models are powerful priors for accelerated MRI reconstruction, but most current methods are posterior samplers, which return a random draw from the posterior. A reproducible and high-quality reconstruction often requires averaging many samples, resulting in a high computational cost. We introduce D-MOD, a fast algorithm that instead provides a posterior mode. It uses a minorize-maximize algorithm on a lower bound of the smoothed log-posterior, which provably increases the objective. Each iteration draws S noisy samples of the current estimate at the current noise level, denoises them with a pretrained diffusion model, and combines their average with the measured k-space through a conjugate-gradient (CG) solve. We anneal the noise levels, as the distance between the bound and its target decays quadratically with noise. On fastMRI brain (T1, T2, FLAIR), a single D-MOD reconstruction exceeds, in PSNR, the 10-sample finite-MMSE estimates of DPS, DAPS and SNORE-P and stays within 0.31 dB of the strongest baselines (DiffPIR, DDS). This approach thus provides a fast deterministic reconstruction algorithm (11-73 times faster than MMSE estimates), which is useful in a clinical setting.

0.36

Diffusion-Encoding Gaussian Field for Joint k-q dMRI Reconstruction

cs.CV ·2026-09-02 ·Zhibo Chen, Yajuan Huang, Yu Guan, Qiuyun Fan, Dong Liang +1 more
similarity 0.48
Abstract · 11 pages, 8 figures. Preprint submitted to IEEE Journal of Biomedical and Health Informatics

Diffusion MRI requires repeated k-space acquisitions over multiple diffusion-encoding directions, making acquisition time dependent on both spatial and angular sampling. Existing joint k-q methods either associate directional parameters with fixed voxels or separate spatial reconstruction from angular completion. However, diffusion-weighted images acquired under different directions share the same anatomical organization, while their local signal intensities vary with diffusion encoding. Existing formulations do not fully exploit the complementarity between shared anatomy and direction-dependent signal variation. Consequently, residual spatial errors may be misinterpreted as genuine angular variation and propagated to unobserved directions. We propose a subject-specific spatial-angular Gaussian field for self-supervised joint k-q dMRI reconstruction. Shared 3D Gaussian primitives provide local spatial support, with each primitive carrying a continuous q-conditioned tensor-residual response. The signal at each location is synthesized from multiple overlapping primitive responses, coupling neighboring spatial regions and diffusion directions. The field is progressively optimized from undersampled k-space measurements of observed directions, without fully sampled targets or held-out-direction supervision. Experiments on three HCP diffusion shells under multiple acceleration settings demonstrated consistent improvements in missing-direction DWI reconstruction, tensor-derived metrics, and principal diffusion orientation estimation.

0.26

Virtual EMI Receiver Generation (VERGE) for Improved EMI Removal in MRI

eess.IV ·2026-11-17 ·Alexander Mertens, Diego Martinez, Amgad Louka, Ying Yang, Chad Harris +1 more
unusual similarity 0.48
Abstract

MRI is not designed to operate in the presence of EMI emitting electronic devices. To accomodate this, we propose VERGE which improves on previous EMI removal methods and can operate without external EMI sensors. VERGE estimates a reference coil non-linearly from all imaging and non-imaging coils by training a small per-scan convolutional neural net to generate a virtual coil. The virtual coil is then used with STRIDE, a reference-based EMI removal method. For single-source EMI contamination, VERGE performed similarly to the reference method. For multi-source dynamic EMI contamination, VERGE outperformed the comparison methods. Notably, VERGE with zero physical EMI sensors outperformed the comparison methods even with two physical EMI sensors. A non-linearly estimated virtual EMI coil improves reference-coil-based EMI removal under dynamic multi-source EMI, and enables effective EMI removal without physical EMI sensors or training data.

0.26

Hankel Subspace Self-Supervised Learning for Parallel MRI Reconstruction

cs.CV ·2026-10-08 ·Mingyu Hu, Siquan Zhu, Xijun Zhong, Qiegen Liu
similarity 0.47
Abstract

Parallel magnetic resonance imaging reconstruction is an ill-posed inverse problem under undersampling. Multi-coil acquisition and Hankel lifting expose complementary repeated information: observations of the same anatomy across coils and repeated local k-space neighborhoods in overlapping windows. These dependencies guide recovery of missing k-space data. However, splitting lifted Hankel entries for self-supervision can place the original sample in both input and target, causing data leakage. We propose Hankel Subspace Self-Supervised Reconstruction (HSSRecon), a scan-specific reconstruction framework for parallel magnetic resonance imaging. HSSRecon partitions data by physical acquisition units before Hankel lifting and applies multiplicity normalization to repeated Hankel copies in overlapping windows. Rather than learning a mapping that directly predicts missing data, the network learns a compact complex-valued Hankel subspace operator. Reconstruction is performed over the original k-space variables using a conjugategradient solver with hard data consistency. This design separates structural learning in the Hankel domain from data consistency in the physical domain: the former exploits multi-coil and local Hankel correlations, while the latter solves over unacquired degrees of freedom. We provide theoretical analyses of physicalgroup splitting and multiplicity normalization, and establish positive definiteness, uniqueness, hard data consistency, and a finite-step conjugate-gradient error bound for the system. On fastMRI brain data with three contrasts and three sampling masks, HSSRecon achieves competitive peak signal-to-noise ratio, structural similarity, and normalized mean squared error across six aggregated conditions.

0.16

Angel: Anchor-Structured Neural Gaussians for Explicit Fetal Diffusion MRI Slice-to-Volume Reconstruction with Cross-Subject Learning

eess.IV ·2026-11-12 ·Wenxuan Wu, Lucy Hall, Jonathan O'Muircheartaigh, Joseph V. Hajnal, J-Donald Tournier +1 more
similarity 0.46
Abstract

Diffusion magnetic resonance imaging (dMRI) provides a noninvasive view of developing tissue microstructure and white matter tracts in the fetal brain. During acquisition, however, fetal motion disrupts spatial correspondence between slices, diffusion encoding directions and signal intensities. We introduce ANGEL, an anchor-structured neural Gaussian framework for accurate slice-to-volume reconstruction (SVR) of fetal dMRI, that simultaneously estimates diffusion signal, fetal motion and intensity artefacts. Unlike standard explicit Gaussian representation, ANGEL is designed to prevent absorption of noise and artefacts into the reconstructed dMRI by learning a compact representation of spatio-angular signal via a shared decoder that predicts 3D Gaussians across anchors and subjects. The individual anatomical variability is compactly represented through subject-specific anchors. Experiments on simulated neonatal and in vivo fetal data show significant improvement of dMRI reconstruction in both spatial and angular domains, in comparison to explicit Gaussian representation, implicit neural representation as well as classical methods.

0.13