CS Paper Radar

Effects of Sequence Timing on the Spatio-Temporal Properties of 3D BOLD fMRI: A Formal Framework and Analysis

Samuel Bianchi, Klaas P. Pruessmann

eess.IV ·submitted 2026-09-17 12:06 UTC · v1

Abstract

3D sequences provide an alternative to 2D or multiband sequences for BOLD fMRI. The impact of acquisition time differences between slices is well understood for 2D or multiband sequences. For 3D sequences, k-space is partitioned into multiple segments and the final image depends on samples taken over an extended period of time. Any precise timing information is lost during reconstruction. A theoretical description of how sequence timing impacts 3D BOLD fMRI data properties is lacking in the literature. We present a formal framework that models sequence timing effects and draw connections to existing literature. The framework rests on the statistical description of a spin system that allows incorporation of BOLD signal changes and is completed by a general description of spatial encoding and image reconstruction. Using this formulation, we define three key images: the actual image reconstructed from a segmented 3D acquisition, an optimal reference image unaffected by sequence timing, and an error image representing their difference. Two sets of operators are defined that describe the generation of these images and allow us to analyse the effects of sequence timing independent of the object. All operators take the form of spatio-temporal filters. They mix signal content spatially and based on its temporal waveform. High-frequency BOLD signal content is affected more strongly compared to low-frequency content. Simulations demonstrate that while the total variance of 3D image time series can be reduced, spatio-temporal fidelity is increasingly lost. Furthermore, we hypothesize that the heightened sensitivity of 3D sequences to physiological noise (compared to 2D) is caused by sequence timing damping thermal noise more strongly than physiological fluctuations. The impact of motion and system instabilities on image time series needs to be studied further.

Closest papers

Nearest neighbours by meaning across the whole index.

SGAM: Shared Gaussian Geometry with Implicit Amplitude Modeling for Scan-Specific 3D Multi-Contrast MRI Reconstruction

cs.CV ·2026-09-21 ·Jingran Xu, Dong Liang, Hairong Zheng, Yuanyuan Liu, Yanjie Zhu
similarity 0.61
Abstract

Three-dimensional (3D) multi-contrast magnetic resonance imaging (MCMRI) provides rich anatomical and quantitative information but requires long acquisition times, motivating k-space undersampling. However, reconstruction of large volumetric datasets imposes substantial computational and memory demands. To address this challenge, we propose SGAM, a memory-efficient, scan-specific framework for joint full-volume 3D MCMRI reconstruction. SGAM is based on a shared-geometry Gaussian representation in which amplitudes are modeled by a multi-output implicit neural representation (INR) and contrast-specific phases by explicit variables. This design exploits common anatomical structure across contrasts while preserving contrast-specific signal variations. The representation is jointly optimized using only the acquired multi-coil k-space without external training data. Experiments showed that SGAM consistently outperformed the comparison methods across imaging tasks and acceleration factors, with greater improvements under stronger undersampling. SGAM also achieved a favorable balance between reconstruction quality and computational cost, demonstrating its effectiveness for 3D multi-contrast MRI reconstruction.

0.12

MnemoDyn: Learning Resting State Dynamics from 40K FMRI sequences

cs.LG ·2026-08-25 ·Sourav Pal, Viet Luong, Hoseok Lee, Tingting Dan, Guorong Wu +3 more
published similarity 0.59
Abstract · ICLR 2026

We present a dynamical-systems based model for resting-state functional magnetic resonance imaging (rs-fMRI), trained on a dataset of roughly 40K rs-fMRI sequences covering a wide variety of public and available-by-permission datasets. While most existing proposals use transformer backbones, we utilize multi-resolution temporal modeling of the dynamics across parcellated brain regions. We show that MnemoDyn is compute efficient and generalizes very well across diverse populations and scanning protocols. When benchmarked against current state-of-the-art transformer-based approaches, MnemoDyn consistently delivers superior reconstruction quality. Overall, we find that with such large-scale pre-training on (non-proprietary) rs-fMRI datasets, we get a highly performant model for various downstream tasks. Our results also provide evidence of the efficacy of the model on small sample size studies which has implications for neuroimaging studies at large where resting state fMRI is a commonly acquired imaging modality.

0.52

DRAFT: Decoding and Reconstructing 3D Room Layouts from fMRI and Camera Trajectories

cs.CV cs.LG ·2026-10-22 ·Chi-Wei Lee, An-Kai Chen, Cheng-Han Chiang, Yi-Chun Chang, Po-Chih Kuo
similarity 0.56
Abstract · 42 pages, 7 figures, 18 tables

While functional magnetic resonance imaging (fMRI) decoders reconstruct images and 3D objects, recovering the metric geometry of rooms from a moving viewpoint remains an open challenge. We introduce, to our knowledge for the first time, the task of reconstructing 3D layouts of held-out scenes using only the known camera trajectories and the fMRI signals of participants watching indoor walkthroughs, without any visual frames. The task is hard because of the temporal mismatch between rapid visual changes and blurred fMRI signals. Our method, DRAFT (Decoding and Reconstructing 3D room lAyouts from fMRI and Trajectories), extracts a compact layout representation from the early visual cortex and fuses this neural code with the geometric free space derived from camera motion. To evaluate it, we propose layout r, the Pearson correlation between predicted and ray-cast log depths. On ten held-out scenes (20 participants), DRAFT reaches a layout r of 0.480, outperforming the camera path alone (0.446) and seven fMRI decoders (at most 0.429). DRAFT also works as a plug-in that improves all seven decoders without retraining, raising their layout r from 0.171-0.429 to 0.487-0.493. Brain activity and camera motion can thus recover the metric layout of unseen rooms, a first step toward reconstructing the 3D spaces people see.

0.23

High-Temporal-Resolution Motion Correction in Magnetic Resonance Fingerprinting Using a Quantitative Scout and Compact Spiral Navigators

eess.SP ·2026-09-21 ·Aizada Nurdinova, Xiaozhi Cao, Daniel R. Abraham, Daniel Polak, Nan Wang +4 more
similarity 0.55
Abstract

Motion correction in magnetic resonance fingerprinting (MRF) helps preserve the accuracy of quantitative maps; however, existing approaches provide motion updates only every 7-8 seconds. We propose a navigation framework that integrates compact k-space navigators throughout the MRF acquisition, enabling sub-second motion estimation at minimal sequence overhead. A 3D spiral-projection MRF sequence was augmented with three orthogonal spiral navigators inserted every 0.5 seconds, enabling motion estimation by comparing navigator signals with quantitative scout (Q-Scout) data, i.e., motion-free low-resolution k-space with matching contrast evolution. The Q-Scout is obtained via a rapid calibration during the dummy preparation period, incurring no additional scan time. Motion estimation is formulated as dictionary matching in a discriminant subspace with optimization refinement. The method was evaluated in simulation and in vivo for 1 mm isotropic brain 3D MRF at 3 T. Across 35 motion-corrupted acquisitions with motion-free references available, the proposed motion correction reduced MRF reconstruction normalized root-mean-square error (NRMSE) by 7.1% and increased the structural similarity index measure (SSIM) by 0.085. Motion estimates aligned with 8 second temporal-rate image-based navigation (mean absolute difference of 0.15 mm and 0.23 degrees), while the proposed method provided higher temporal resolution and improved motion correction. The proposed framework enables robust motion navigation in MRF at 0.5 second temporal resolution with minimal sequence overhead. By using contrast-consistent modeling and efficient inference, it improves the reliability of quantitative MRI under rapid, unpredictable motion.

0.23

FAST-Brain: A Flow-Aligned Spatio-Temporal Surrogate Brain Model

cs.LG q-bio.NC ·2026-09-28 ·Shucheng Liu, Changchun Shi, Kai Zhang, Hongtu Zhu
similarity 0.55
Abstract

Modeling resting-state functional magnetic resonance imaging (rs-fMRI) data is crucial for understanding brain-wide neural activity. However, traditional methods struggle to capture complex temporal dynamics over long horizons, to account for the brain's anatomical spatial structure, and to model high-dimensional ambient signals that lie on a low-dimensional intrinsic subspace. We propose FAST-Brain, a unified flow-aligned spatio-temporal surrogate brain model that addresses all three challenges. At its core is a flow-aligned generative framework that directly predicts the clean blood-oxygen-level-dependent (BOLD) signal, paired with a graph convolutional network that captures spatial structural constraints and a Transformer that models long-range temporal dependencies. Theoretically, we show that under a low-dimensional subspace assumption, the approximation error of our model scales with the intrinsic dimension rather than the ambient dimension, which justifies our direct modeling of the BOLD signal. Extensive experiments on synthetic and Human Connectome Project datasets demonstrate that FAST-Brain achieves state-of-the-art performance in recovering functional connectivity, effective connectivity, and the implicit low-dimensional signal subspace.

0.15

When Model Complexity Matters in Cross-Subject Naturalistic fMRI Prediction

cs.AI q-bio.NC ·2026-11-02 ·Junhao Zhao, Jacob Kang, Colin Kurniawan, David Simberg, Nan Xu
similarity 0.55
Abstract · 43 pages

Increasingly complex neural models predict blood-oxygen-level-dependent (BOLD) responses to naturalistic stimuli, but the predictive value of this added complexity remains unclear. We ask when pretrained stimulus representations help and how much downstream complexity is needed, with and without recent measured BOLD history. We compare linear diagnostic references and nonlinear predictors across HCP movie fMRI (154 subjects), BOLD Moments (10 subjects), and Algonauts 2025 (4 subjects). Under a shared offline protocol, models are fitted on training subjects and evaluated on held-out subjects viewing largely familiar stimuli, without refitting. Pretrained visual features generally improve prediction over raw pixels; for linear autoregression, this advantage becomes more pronounced over longer rollouts (recursive predictions without additional measured BOLD). Measured BOLD history provides substantial gains that generally diminish {as rollouts lengthen}. Nonlinear stimulus-only predictors can improve on linear readouts, whereas linear autoregression provides a strong history-conditioned baseline. Controls examine context length, regularization, fitting procedures, and model capacity. Regional response consistency across subjects is associated with held-out prediction accuracy, while less consistent regions tend to gain more from measured history. In paired simulations with fixed linear neural dynamics, slower hemodynamic responses generally sustain high temporal prediction correlations over longer rollouts, illustrating how the observation process can contribute to predictive persistence. Together, these findings support evaluating stimulus representations and downstream complexity separately, using history-conditioned linear prediction as a diagnostic reference under matched inputs and measurement availability.

0.23

SpinSCI: Mask-Conditioned Spatial-Temporal Spin Transformer for Video Snapshot Compressive Imaging

cs.CV ·2026-11-09 ·Seungki Hong, Zhishuai Zhang, Taekwang Jang
benchmarkcode/dataunusual similarity 0.54
Abstract

Video snapshot compressive imaging (SCI) recovers multiple frames from one spatiotemporally coded measurement. This paper proposes SpinSCI, a mask-conditioned Spatial-Temporal Spin Transformer whose Mask-Conditioned Ising Refinement Block (MC-IRB) combines attention logits and sensing information to form signed spin couplings. Finite mean-field updates gate residual feature refinement. Physics-guided initialization and final data consistency incorporate the measurement model. Compared with HiSViT$_9$, SpinSCI achieves average PSNR gains of 0.51 dB, 0.23 dB, and 0.04 dB on small-scale gray, mid-scale color, and large-scale color benchmarks, respectively, with 16.9% fewer parameters, 21.0-21.6% fewer FLOPs, 17.1-49.9% lower latency, and 62.3-63.3% lower peak memory. Relative to DU-9stg, average PSNR differs by at most 0.13 dB across these benchmarks, with 28.2-28.7% fewer FLOPs, 64.6-71.7% lower inference latency, and 30.1-35.0% lower peak memory. Qualitative comparisons on the real benchmark further show recovery of fine details and textures. Code and reference checkpoints are available at https://github.com/skethz/SpinSCI.

0.34

High-Resolution Quantitative MRI Using Contrast-Domain Multiscale Energy (MuSE) Regularization

eess.IV ·2026-11-03 ·Rushdi Rusho, Jyothi Rikhab Chand, Steve R. Kecskemeti, James H. Holmes, Mathews Jacob
similarity 0.54
Abstract · 5 pages, 3 figures

Quantitative MRI methods can offer tissue parameter maps (e.g. T1) that are comparable across scanners, sessions and subjects, together with multiple contrast-weighted images from a single scan. However, most data are acquired at 1 mm, which limits their use in neurodegenerative diseases that affect fine brain structures. We introduce, to our knowledge, the first diffusion-model-based reconstruction for quantitative MRI at 0.5 mm isotropic resolution from scans of less than 5 minutes, which has eightfold smaller voxel volume than clinical protocols. The key idea is to apply the prior to the synthesized contrast images rather than to the subspace coefficients. The prior is then independent of the temporal basis and the sequence, which improves generalization and allows a 2-D multiscale energy (MuSE) model trained on grayscale CelebA face images to be used without any MRI training data. The explicit energy makes reconstruction MAP estimation by a step-size-free majorize-minimize algorithm that regularizes a rotating subset of contrasts along different axes, which makes 3-D multi-contrast reconstruction tractable. For 3-D radial MPnRAGE at 7 T in 4.3 min, MuSE reduced the phantom NRMSE from 0.133 (CG-SENSE) and 0.091 (L1-wavelet) to 0.074 and the WM T1 interquartile range from 117 and 47 ms to 38 ms, and it was demonstrated in vivo at 7 T.

0.24