CS Paper Radar

Virtual EMI Receiver Generation (VERGE) for Improved EMI Removal in MRI

Alexander Mertens, Diego Martinez, Amgad Louka, Ying Yang, Chad Harris, Ian Connell

eess.IV ·submitted 2026-11-17 06:13 UTC · v1
unusual

Abstract

MRI is not designed to operate in the presence of EMI emitting electronic devices. To accomodate this, we propose VERGE which improves on previous EMI removal methods and can operate without external EMI sensors. VERGE estimates a reference coil non-linearly from all imaging and non-imaging coils by training a small per-scan convolutional neural net to generate a virtual coil. The virtual coil is then used with STRIDE, a reference-based EMI removal method. For single-source EMI contamination, VERGE performed similarly to the reference method. For multi-source dynamic EMI contamination, VERGE outperformed the comparison methods. Notably, VERGE with zero physical EMI sensors outperformed the comparison methods even with two physical EMI sensors. A non-linearly estimated virtual EMI coil improves reference-coil-based EMI removal under dynamic multi-source EMI, and enables effective EMI removal without physical EMI sensors or training data.

Closest papers

Nearest neighbours by meaning across the whole index.

SNIF: a Self-Navigator Intelligent Filter correcting off-center and spin-history artifacts in quasi-random radial MRI

eess.IV ·2026-11-09 ·Tanguy Boucneau, Brice Fernandez, Peder Larson, Luc Darrasse, Xavier Ma{î}tre
unusual similarity 0.48
Abstract · 10 pages, 6 figures; supplementary material (93 pages): DC-signal spectra for every reception channel

For self-navigation and self-gating in MRI, self-navigators are extracted from the complex values of the k-space center, called DC-signal, through a temporal frequency analysis. However, this signal often carries artifacts. This paper introduces a Self-Navigator Intelligent Filter (SNIF) that models the physical origin of the k-space center artifacts to properly estimate them and thus more accurately remove them. The artifact affecting the DC-signal $S_{DC}$ generally has two main origins: the jitter of the k-space center (''off-center artifact'') and the cumulative history of the spins (''spin-history artifact''). Both add noise-like artifacts to the signal. The off-center effect can be modeled as a perturbative signal $S_0$ and the spin-history effect as a convolution kernel $h$ so that the measured DC-signal is $S_{DC} = S_m + S_0 \star h$, where $S_m$ is the motion-related component which effectively contains the expected self-navigators. Methods to compute $h$ and $S_0$ were developed, which gives the possibility to extract $S_m$ from $S_{DC}$. They were implemented and evaluated on thoracic UTE datasets acquired on a healthy volunteer. Qualitative visual comparison and quantitative spectral analysis of the DC-signal before and after SNIF demonstrate that the method improves both the accuracy and the precision of the extracted respiratory and cardiac self-navigators. By considering the physical origin of the DC-signal artifacts, SNIF makes both respiratory and cardiac self-navigators more sensitive to motion, which supports finer MRI motion tracking.

0.27

Detection Instead of Inversion: T1-T2 Microstructure Quantification With Detection Transformers

cs.CV cs.LGphysics.med-ph ·2026-11-01 ·Sebastian Endt, Fatih Özkan, Marion I. Menzel
code/data similarity 0.46
Abstract · 4 pages, 3 figures, 1 table; For submission to IEEE ISBI 2027; Code: https://github.com/SebastianEndtTHI/t1t2-detr

T1-T2 correlation MRI has strong potential to quantify microstructural compartments without imposing a biological model. Traditionally, full T1-T2 spectra per voxel are reconstructed with an ill-conditioned and time-consuming Inverse Laplace Transform. We propose to view this challenge as an object detection task: A Detection Transformer (DETR) takes 64 TI/TE signals and directly predicts a set of compartments specified by T1, T2, and signal fraction. We achieve a mean average precision mAP@10 of 76.8% on simulated data, outperforming both our previous model design (53.8%) and regularized NNLS (66.1%). We show that our DETR approach outperforms NNLS in almost every setting across compartment count, compartmental signal fraction, and SNR. Reconstruction is orders of magnitude faster than NNLS. The results are fully reproducible from our public code: github.com/SebastianEndtTHI/t1t2-detr

0.29

Fast Self-Supervised Generative CT Denoising via Few-Step Sampling

cs.CV ·2026-11-19 ·Xingyi Yao, Zhengtao Ma, Zhennong Chen
similarity 0.46
Abstract · 30 pages, 4 figures, 2 tables. Xingyi Yao and Zhengtao Ma contributed equally to this work. Zhennong Chen is the corresponding author

Low-dose and thin-slice computed tomography (CT) images suffer from elevated noise that obscures anatomical detail, while clean references for supervised denoising are often unavailable. Although Noise2Noise permits self-supervised training from noisy pairs, direct regression tends to oversmooth fine structure. Averaging multiple independently generated samples mitigates this blur, though repeating multi-step diffusion sampling is costly. We introduce Noise2Noise with Improved Mean Flow (N2N-iMF) to accelerate this process via few-step sampling. N2N-iMF learns to generate one noisy image conditioned on its paired counterpart; at inference, independent outputs are sampled and averaged to suppress noise. We evaluated image quality and sampling efficiency on simulated thin-slice brain and low-dose abdominal CT across four sampling methods and averaging counts from 1 to 20, and validated the approach on real-world photon-counting CT (PCCT) brain scans. With ten samples per conditioning input and three network evaluations per sample, N2N-iMF achieved a mean absolute error of 2.60 HU on brain CT and 14.02 HU on abdominal CT, outperforming 50-evaluation denoising diffusion implicit model (DDIM) sampling (2.91 and 14.53 HU). On the same GPU, per-output generation time dropped from 7.29 to 0.43 s. Across eight PCCT cases, N2N-iMF reached a mean gray-white matter contrast-to-noise ratio of 1.341, versus 0.916 for Noise2Noise and 1.176 for DDIM. N2N-iMF accelerates self-supervised generative CT denoising without distillation while keeping the number of averaged outputs adjustable at inference.

0.24

Toward Contrast-Free Breast MRI: Improving Cancer Detection With Virtual Contrast Enhanced Imaging

eess.IV cs.CV ·2026-10-29 ·Hongxi Chen, Sunwoo Kwak, Sanyukta Adap, Katerina Dodelzon, Paula Feldman +1 more
similarity 0.45
Abstract · 5 pages, 2 figures, 1 table. Submitted to ISBI 2027

Although contrast-enhanced (CE) breast MRI is an important tool for cancer detection, intravenous gadolinium administration introduces additional considerations for patients and clinical workflows. AI based virtual contrast enhanced (VCE) MRI could help identify patients for whom acquired CE imaging may be avoidable without compromising diagnostic performance. We developed a framework that combines non contrast (NC) and VCE MRI predictions for cancer detection. On the held-out test set, cancer detection using NC MRI alone achieved an AUROC of 0.865. Combining the predictions from NC and VCE MRI improved AUROC to 0.901. Building on this complementary predictive value, we evaluated patient-level routing to progressively replace acquired CE examinations with the NC plus VCE pathway, prioritizing patients with the most confident NC predictions. This simulation suggests that diagnostic performance can be largely preserved while limiting acquired CE imaging to approximately 40% of patients. Together, these findings demonstrate the complementary value of VCE MRI and suggest its potential to support selective contrast use in breast cancer screening.

0.22

Susceptibility source separation via Closed-form Alternating Newton-type Optimization

eess.IV ·2026-11-19 ·Ignacio Contreras-Zúñiga, Cristian Tejos, Carlos Milovic
similarity 0.45
Abstract

Quantitative Susceptibility Mapping (QSM) provides a bulk magnetic susceptibility estimate per voxel, so contributions from paramagnetic and diamagnetic sources within the same voxel partially cancel. Susceptibility source separation methods identify these compartments by fitting a three-pool complex exponential model to multi-echo gradient-echo (GRE) data. However, conventional voxel-wise fitting with general-purpose constrained solvers requires several hours per whole-brain volume and often fails in high-susceptibility regions. We present CANON-QSM (Closed-form Alternating Newton-type Optimization for QSM), a solver that reformulates the subproblems of the three-pool model and solves them alternately via exact closed-form updates and Newton-type steps, yielding a substantial per-voxel computational speedup. Both in silico and in vivo evaluations demonstrate not only a massive reduction in reconstruction time, completing a whole-brain volume in under two minutes, but also improved accuracy and robustness against artifacts in high-susceptibility regions. Finally, an echo-time analysis of the three-pool model shows that source separation is driven by second-order nonlinearities in signal decay and phase evolution rather than first-order bulk estimates.

0.25

Revolutionizing Diffusion MRI Microstructure Mapping via Global Inversion

eess.IV eess.SP ·2026-09-24 ·Yuxiang Wan, Hamza Farooq, Wenjie Zhang, Qiaozhi Huang, Lingjie Su +2 more
similarity 0.45
Abstract

Diffusion MRI microstructure mapping (MM) is conventionally solved voxel by voxel, ignoring the fact that tissue microstructure forms a spatially organized field. This isolation leaves each estimation problem ill-posed and nonconvex. We instead cast MM as a single global inverse problem, reconstructing the entire parameter field jointly from all measurements of a subject. An untrained neural representation supplies implicit spatial priors and eases the nonconvex optimization, requiring no training data, while coregistered T1-weighted anatomy contributes structural guidance that is freely available in standard protocols. On both synthetic and in-vivo data, our method compares favorably with established voxel-wise and learning-based baselines, suggesting global inversion is a promising alternative.

0.18

Beyond MSE: Rician Likelihood Denoising for Self-Supervised Cardiac $T2$ and $T1ρ$ MRI

eess.IV cs.CV ·2026-09-24 ·Nicholas A. Jacobs, Jason Mendes, Ravi Ranjan, Edward DiBella, Shireen Elhabian
similarity 0.44
Abstract · Made minor spelling and punctuation corrections

Magnetic resonance imaging involves an inherent trade-off among spatial resolution, acquisition time, and noise. This trade-off contributes to long scan times and high cost. Deep learning has improved image denoising, but cardiac MRI remains difficult because high-resolution, rapid acquisitions generally lack corresponding low-noise ground truth. Self-supervised denoising offers a potential solution by learning from noisy image pairs or even single noisy acquisitions. However, we show that Noise2Void-style blind-spot denoising, which uses a mean squared error (MSE) loss and assumes zero-mean, independent and identically distributed (i.i.d.) noise, is poorly suited to MR magnitude images. When applied to short-axis $T2$-weighted and $T1ρ$-weighted cardiac MRI with synthetic Rician noise, it produces biased denoised images and biased parametric maps of $T2$ and $T1ρ$. To address this limitation, we formulate self-supervised denoising as maximum likelihood estimation under a known Rician noise model. This yields unbiased denoisers that are competitive with supervised baselines.

0.22

Generalizable field of view extension for diffusion MRI via conditional flow matching

cs.AI ·2026-10-12 ·Gaurav Rudravaram, Lianrui Zuo, Ema Topolnjak, Michael E. Kim, Adam M. Saunders +20 more
similarity 0.44
Abstract

Incomplete field-of-view (FOV) diffusion MRI (dMRI) acquisitions compromise whole-brain white matter analysis by excluding brain regions from tractography and connectivity studies. While deep generative models for dMRI FOV extension have been proposed, their generalizability remains limited by the acquisition-dependent nature of dMRI, where signal intensity varies with b-value, gradient direction, and scanner protocol, and the inherent 4D complexity of the data, making it difficult to train models that transfer across sites or acquisition schemes without retraining. We propose a flow-matching generative model that extends the dMRI FOV in both the superior and inferior directions by predicting apparent diffusion coefficients (ADC) in six directions, conditioned on the two nearest acquired slices and the full-FOV T1w image to enforce both local diffusion continuity and anatomical consistency. The ADC representation decouples the model from acquisition-specific b-values and gradient directions, providing a middle-ground across protocols. The model was trained on 3,103 subjects (5,105 sessions) across five different datasets spanning diverse acquisition schemes (b = 500 and 1000 s/mm$^2$; 21--192 gradient directions), four single-shell (b = 1000) and one multi-shell (b = 500/1000). Evaluated on 299 subjects across five independent datasets spanning b = 750--1500 s/mm$^2$ and 32--90 gradient directions, with single- and multi-shell schemes unseen during training, the proposed method achieves significantly improved bundle Dice score on downstream tractography (p < 0.01).

0.16