CS Paper Radar

A four-step validation protocol for radiomic survival analysis in small cohorts: a body composition case study

Mariela Talavera-Muñoz, Cecilia Diana-Albelda, Miguel Antonio Sampedro-Nuñez, Victor Rodriguez-Laval, Jesus Bescos, Álvaro García-Martín

eess.IV cs.CVcs.LG ·submitted 2026-11-09 16:46 UTC · v1
code/data

Abstract

Gastroenteropancreatic neuroendocrine tumors (GEP-NET) lack prognostic biomarkers, and computed tomography (CT)-based body composition radiomics at the third lumbar vertebra (L3) is a promising candidate. Small cohorts make high-dimensional radiomic models prone to overfitting and single-split evaluations variable and optimistic. This methodological study proposes a four-step validation protocol for radiomic survival analysis in small cohorts: (1) false discovery rate (FDR)-corrected feature selection, (2) a dual-path comparison of prior feature selection versus embedded regularization, (3) repeated nested cross-validation (CV) and (4) a negative control with Gaussian noise features. In 78 GEP-NET patients, 535 radiomic features from five L3 compartments were used to evaluate five survival models with Harrell's concordance index (C-index), time-dependent area under the curve (AUC) and integrated Brier score (IBS). Step 1 selected at least one feature in 18% of outer folds under noise (nominal level 20%) versus 84% with radiomic features. The dual-path comparison showed no consistent difference between strategies. Repeated nested CV reduced variability across seeds (41% median reduction in C-index standard deviation), but not enough to distinguish models. The nested CV C-index exceeded chance by 0.07-0.15 with radiomic features but not clearly under noise (0.40-0.42 with prior feature selection, 0.47-0.55 with embedded regularization). Frequently selected features tentatively linked greater subcutaneous fat, skeletal muscle compactness and texture to better prognosis. These findings suggest a modest prognostic signal in L3 radiomics, with considerable uncertainty that the protocol quantifies. The protocol may transfer to other small-cohort radiomic survival studies. Code: https://github.com/marielatalaveram/radiomics-survival-validation-protocol.

Closest papers

Nearest neighbours by meaning across the whole index.

How Robust Are Prognostic Radiomic Features? Comparing Selection Techniques on Pooled Glioblastoma Cohorts

cs.CV cs.AIq-bio.QM ·2026-10-19 ·Yannick Sodonougbo, Marlene Schnieders, Alexia Rizoudis, Santiago Cepeda, Frank Kramer +1 more
similarity 0.67
Abstract · 7 pages, 1 figure

Radiomic survival studies in glioblastoma report heterogeneous prognostic features, but how much of this stems from the methodology itself is rarely examined. We analysed the association of 463 radiomic, anatomical and clinical features from pre-treatment MRI with overall survival in 705 IDH-wildtype glioblastoma patients from three public cohorts, using three techniques: a log-rank test after median split, univariate Cox regression (both Benjamini-Hochberg corrected) and an XGBoost regressor interpreted with SHAP. The log-rank test selected 99 features, Cox regression 72 and SHAP its top 20; five were selected by all three: age, a peritumoural T2 texture feature, the number of connected peritumoural mask components and two image-level intensity maxima. The two survival tests shared 51 features, about half of the SHAP top 20 were also selected by either test, and where selections overlapped, effect directions agreed. Many selections were PyRadiomics diagnostic descriptors that are not restricted to tumour voxels. Analytical pipeline choices, including ranking method, pre-filtering and descriptor handling, can substantially influence which features appear prognostic.

0.24

Radiomics--Foundation Fusion for Interpretable RCC Classification: Internal Benchmarking and Exploratory External Transfer

cs.CV ·2026-09-22 ·Yuan Liang, Fangyijie Wang, Kathleen M. Curran, Guénolé Silvestre, Sourav Bhattacharjee +1 more
published similarity 0.64
Abstract · Accepted for an oral presentation at CaPTion 2026, a MICCAI 2026 workshop. 11 pages, 3 figures

Accurate preoperative subtype classification of renal cell carcinoma (RCC) from contrast-enhanced CT remains clinically challenging because clear cell RCC (ccRCC) and non-clear cell RCC often show overlapping imaging appearances. This study evaluates whether foundation representations reduce reliance on handcrafted radiomics, or whether radiomics remains complementary for interpretable tumour characterisation. We compared radiomics, conventional CNN features, MedicalNet-pretrained features, MedVAE representations, and fusion variants for binary ccRCC classification on KiTS23, reporting area under the receiver operating characteristic curve (AUC) with bootstrap confidence intervals and average precision (AP) as a complementary class-imbalance-sensitive metric. We further assessed branch-removal ablation, TCGA/AIMI external transfer, and interpretability using radiomics permutation importance and gate-level analysis. Internally, 3D MedVAE gated fusion achieved the best performance, with an AUC of 82.7% and AP of 92.2%. On the external TCGA cohort, the same model achieved an AUC of 79.5% and AP of 98.9%, although specificity remains uncertain because only two external non-ccRCC cases were available. Gate analysis showed a radiomics-dominant fusion regime, suggesting that foundation representations acted as case-dependent refinement signals rather than replacements for structured tumour descriptors. These findings support radiomics as a complementary and clinically interpretable component of CT-based RCC characterisation in the foundation-model era.

0.42

Resampling-based batch reweighting for ComBat harmonization of MRI radiomic features in a multi-scanner glioma cohort

eess.IV physics.med-ph ·2026-11-01 ·Rifa Sajda Tasnim, Yushuf Sharker, Md Forhad Hossain, Rakibur Rahman, Enamul Hoque Bhuiyan
published similarity 0.61
Abstract · Original article. Submitted to Journal of Magnetic Resonance Imaging (JMRI)

Radiomic features derived from magnetic resonance imaging (MRI) are sensitive to scanners; therefore, they require harmonization across scanners. In a radiomic feature dataset, some batches may be severely underrepresented compared to the others e.g., the Erasmus Glioma Database, which may provide harmonized features biased towards the larger batches in the dataset. We investigated whether reweighting underrepresented scanner batches before empirical-Bayes ComBat estimation improves feature harmonization and reduces residual scanner association while retaining grade-related information. In this retrospective, the Erasmus Glioma Database included 733 eligible patients acquired at a single center across nine vendor-by-field-strength configurations. Structural MRI acquired at 1 T, 1.5 T, and 3 T; four structural MRI sequences were analyzed. From four structural MRI sequences, 428 features were computed using an IBSI-compliant PyRadiomics implementation. The sample sizes of some scanner batches were very small compared to others, which may produce unequal precision and shrinkage of batch-effect estimates. We proposed a data augmentation approach to overcome the limitation of ComBat. We provided exploratory evidence, along with confirmatory Kruskal-Wallis tests with a Benjamini-Hochberg correction to assess the proposed method. Before harmonization, 392/428 features (91.6%) differed significantly across scanner batches (median eta-squared=0.463). Standard ComBat reduced this to 13/428 (3.0%), whereas batch-augmented ComBat reduced it to 8/428 (1.9%); the median residual effect size was <0.001 for both harmonized conditions. Batch augmentation appeared to be a useful strategy to improve the performance of ComBat for feature harmonization under severe batch-size imbalance.

0.32

Radiomics-Based Thyroid Nodule Classification with Label-Conditional Conformal Prediction

eess.IV cs.CVstat.AP ·2026-10-09 ·Laura Testa, Pierpaolo Brutti, Umberto Ferraro Petrillo
published similarity 0.60
Abstract · Accepted at the CIBB 2026 conference (https://cibb2026.teralab.ai/)

Thyroid nodule malignancy assessment relies on ultrasound imaging, yet current risk stratification systems suffer from substantial interobserver variability, contributing to a high rate of unnecessary biopsies. We propose a radiomics-based framework combining quantitative feature extraction via PyRadiomics with a Generalized Additive Model (GAM) classifier, selected among six candidates for its favorable trade-off between discriminative performance and interpretability. To complement point predictions with uncertainty estimates, Cross-Conformal Prediction with label-conditional guarantees is applied, flagging ambiguous cases for clinical review rather than forcing a binary decision. Experiments are conducted on TN5000, a publicly available ultrasound dataset of thyroid nodules. After Spearman correlation filtering, 36 features are retained and the GAM achieves an AUC of $0.89$, a sensitivity of $0.83$, and a specificity of $0.82$ on the validation set. At a significance level $ε=0.09$, selected to ensure empirical coverage guarantees on both classes, 63\% of nodules on the test set receive a certain (i.e., single-label) prediction, with conditional precision of $0.94$ for certain malignant and conditional Negative Predictive Value (NPV) of $0.73$ for certain benign cases, while the remaining 37\% are referred to the clinician.

0.47

Beyond Discrimination: Evaluating Probability Calibration in Radiomics-Image Fusion for Renal Cell Carcinoma Classification

eess.IV cs.AIcs.CVq-bio.QM ·2026-10-09 ·Yuan Liang, Morgan May, Abraham Campbell, Sourav Bhattacharjee, Simon Caton +1 more
top venue similarity 0.58
Abstract · 12 pages. 1 figure. Accepted at the 2026 Irish Conference on Artificial Intelligence and Cognitive Science (AICS 2026). Proceedings forthcom…

Reliable probability estimates are important for the clinical interpretation of machine-learning classifiers, yet radiomics--image fusion models for renal cell carcinoma (RCC) are commonly evaluated primarily by discrimination. Using 396 patients from the KiTS23 dataset, we evaluated whether adding radiomics to four image-model families improved probabilistic performance in addition to discrimination. Seventeen individual models and four probability-average ensembles were assessed using discrimination, probability calibration, and proper scoring measures. Across 12 matched image-only versus fusion comparisons, AUC and AP improved in all 12, while Brier score and negative log likelihood (NLL) improved in 11 of 12 and expected calibration error (ECE) in eight of 12. The 3D MedVAE gated-fusion model achieved the strongest overall individual-model profile. Probability averaging across concatenation, cross-attention, and gated fusion produced favourable point estimates across all five primary metrics relative to image-only models in all four families, although paired-bootstrap support was stronger for Brier score and NLL than for ECE. These findings show that radiomics--image fusion can improve probabilistic prediction quality beyond discrimination, while calibration behaviour varies across image architectures and fusion strategies. We show that our proposed probability-average ensemble models improve discrimination and calibration simultaneously across all architectures in the study.

0.38

Radiomics-Conditioned Modulation of RenalCLIP Features for Clear Cell Renal Cell Carcinoma Classification

cs.CV cs.AI ·2026-09-22 ·Yuan Liang, Sourav Bhattacharjee, Abraham Campbell
published similarity 0.58
Abstract · Accepted at the 7th International Conference on Medical Imaging and Computer-Aided Diagnosis (MICAD 2026). 10 pages, 2 figures

Radiomics provides quantitative descriptions of tumour appearance that may complement disease-specific foundation models in small labelled cohorts. We investigate this complementarity for computed tomography-based classification of clear cell renal cell carcinoma. Our framework uses radiomics to modulate RenalCLIP features through feature-wise linear modulation (FiLM), while retaining a direct radiomics contribution. Internal testing and external validation compare it with conventional fusion strategies and reference classifiers. The FiLM model achieves an area under the receiver operating characteristic curve (AUC) of 0.804 internally and 0.854 externally, with the highest mean AUC among the evaluated RenalCLIP fusion strategies in both cohorts. Pathway ablations examine the contributions of conditional modulation and the direct radiomics residual, while feature permutation highlights the role of tumour texture. These findings support radiomics as a useful complement to RenalCLIP in a small labelled cohort and identify FiLM as an effective approach to integrating their representations for robust renal tumour classification.

0.44

A Multimodal Dataset for Survival Prediction in Resected Pancreatic Ductal Adenocarcinoma

cs.CV ·2026-09-24 ·Anh-Tien Nguyen, Mawuko Tettey, Jacqueline Michelle Metsch, Teresa Zimmer, Niklas Ullrich +12 more
similarity 0.58
Abstract

Survival research in pancreatic ductal adenocarcinoma (PDAC) is limited by the scarcity of datasets linking whole-slide histology with clinical, molecular, and long-term outcome data. We present a retrospective single-centre cohort of 302 patients who underwent PDAC resection at University Medical Center Gottingen. The dataset comprises 446 H&E whole-slide images, clinicopathological variables, targeted sequencing data for 154 patients, and overall-survival outcomes. During follow-up, 253 patients died, and the median follow-up was 76 months. To establish initial reference values, we evaluated fourteen survival-prediction configurations using identical five-repetition Monte Carlo cross-validation partitions. Ridge Cox regression using numeric clinicopathological variables achieved a mean concordance of $0.649 \pm 0.042$ and $0.652 \pm 0.046$ after adding KRAS and TP53 mutation status. The image-only attention model achieved $0.603 \pm 0.030$, while multimodal fusion achieved $0.619 \pm 0.025$, the highest concordance among the neural models. These results establish promising initial benchmarks for future research using this pancreas-specific multimodal dataset, paving the way for external validation.

0.25

Evidence-Bound Reasoning: Neuro-Semantic Verification of Biomedical AI in Glioblastoma Radiogenomics

cs.CL ·2026-10-06 ·Mariya Miteva, Maria Nisheva-Pavlova
benchmark similarity 0.57
Abstract · 15 pages, 4 figures, 4 tables. Preprint

Background: Biomedical AI can generate plausible explanations without reliably verifying whether each statement is supported by patient-specific evidence. We developed a neuro-semantic verification framework that converts radiomic measurements into addressable evidence records and machine-checkable claims. Methods: UPenn-GBM radiomics were aligned with de novo CaPTk extraction from standardized MRI and expert-validated segmentations in an independent multicenter cohort. The shared space comprised 1,728 features from T1, T1GD, T2, and FLAIR MRI across three tumor regions. Reference-defined semantic states were derived from 611 UPenn cases. We evaluated cross-cohort transportability, model-linked provenance, deterministic verification, controlled predictive degradation, and an LLM claim-extraction pilot; MGMT prediction served only as a transport stress test. Results: Median semantic-state agreement was 0.786 (weighted kappa 0.709), ranging from 0.918 for morphologic to 0.252 for intensity features. The external evidence ledger contained 1,655 model-linked records for 331 patients. The verifier achieved 100% exact-set accuracy in a 6,620-claim corruption benchmark. In a 24-case pilot, GPT-5.6 Sol reproduced 72/72 prespecified atomic claims, and the frozen verifier recovered 24/24 expected conditions. During controlled degradation, ROC AUC declined from 0.899 to 0.500 while verification accuracy remained 1.000. External MGMT discrimination was weak (ROC AUC 0.543). Conclusions: Verifiability can be engineered and evaluated independently of predictive performance. LLMs may structure explanations, while final evidence-consistency checking remains deterministic.

0.23