CS Paper Radar

Daily listing

2026-11-12 · eess.IV

11 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 11

Data Archive for 2D and 3D Electrical Impedance Tomography with moderate conductivity contrast phantoms

eess.IV cs.LG ·2026-11-12 ·S. J. Hamilton, A. Hauptmann, A. Hänninen, V. Kolehmainen, J. Niskanen +2 more
code/data
Abstract · 11 pages, 6 figures. Data available at https://doi.org/10.5281/zenodo.24120439

This document describes open Electrical Impedance Tomography (EIT) measurement data that were collected from biomedical imaging inspired phantoms with moderate conductivity contrasts. The data were collected with the KIT4 and KIT5 EIT measurement devices at the University of Eastern Finland, and are intended for EIT image reconstruction algorithm development and testing. The data from thoracic imaging inspired cylindrical and chest-shaped phantoms are suitable for 2D algorithms, and the data from an intracerebral hemorrhage imaging inspired head-shaped phantom with resistive skull are suitable for 3D algorithms. In addition to the measurement data, computational meshes and example reconstruction codes are provided and sample reconstructions included.

0.34

Automated PD-L1 Tumor Proportion Scoring with Uncertainty-Guided Triage in Non-Small Cell Lung Cancer

cs.CV eess.IV ·2026-11-12 ·Kesi Xu, Ayesha Azam, Tanvier Kaur, Monika Kondratowicz, Kinza Asim +5 more
hot direction
Abstract · 55 pages (29-page main text with 5 figures and 3 tables, followed by 26 pages of supplementary material)

Programmed death-ligand 1 (PD-L1) tumor proportion score (TPS) informs immunotherapy selection in non-small cell lung cancer. Near the 1% and 50% cutoffs, the score should also indicate when closer review is warranted. We designed a three-stage framework to follow the sequence of TPS assessment. Stage 1 identifies tumor regions and excludes macrophage-rich patches. Stage 2, a dual-branch cell counting network (D2Count-Net), counts PD-L1-positive and PD-L1-negative tumor cells in these regions to calculate TPS. Stage 3, TPS-Guard, an uncertainty-guided triage mechanism, reports model uncertainty as the disagreement among independently trained models, refers the most uncertain slides, and flags scores near the 1% or 50% cutoff when model estimates disagree across that cutoff. Flags state the reason for referral or alert the pathologist to possible scoring errors on auto-reported slides. In a retrospective, single-center study, 154 whole-slide images were scored by three pathologists, and the model and each pathologist were compared in turn with the mean of the other two. On the 114 slides unseen in training, model mean absolute error (MAE) was 6.96 percentage points, within the range of the three pathologists (4.24 to 8.29), and model uncertainty correlated with absolute TPS error (Spearman rho = 0.77) and inter-pathologist disagreement (rho = 0.71). After referral of the 15% most uncertain slides, model and pathologist MAE both decreased. Applied without retraining to an external, publicly available dataset, TPS-Guard still directed review to higher-error cases, and referring more uncertain cases raised sensitivity at the 50% cutoff. TPS-Guard provides reasons for reviewing individual automated scores and identifies slides that also produce greater disagreement among pathologists. Prospective reader studies should assess TPS-Guard's effect on TPS reporting.

0.31

Transmission-Mode Multispectral Imaging for Estimation of Microcystis spp. Cell Concentration and ELISA-Equivalent Microcystin Concentration in Water

eess.IV eess.SP ·2026-11-12 ·J. A. S. T. Jayakody, G. Thilakarathne, G. A. S. L. Ranasinghe, M. C. L. De Silva, K. A. D. S. A. Perera +5 more
unusual
Abstract · 30 pages, 9 figures, 2 tables. Includes Supplementary Information

Harmful algal blooms dominated by Microcystis spp. threaten freshwater systems through proliferation and microcystin (MC) production. Conventional measurements of cyanobacterial abundance and MC concentration commonly require laboratory processing, specialized instrumentation, or assay reagents. Because MC concentration cannot always be reliably inferred from cell abundance, complementary optical approaches for estimating both quantities are of interest. This study proposes and evaluates a transmission mode multispectral imaging (MSI) framework for estimating Microcystis spp. cell concentration and ELISA-equivalent MC concentration from culture derived dilution samples. A custom built MSI system acquiring twelve spectral bands from near-ultraviolet to near-infrared wavelengths measured transmitted light spectral responses. Following principal component analysis based dimensionality reduction, spectral variation was quantified using an aggregated Wasserstein distance descriptor for regression based prediction. Cell concentration estimation yielded $R^2=0.9819$ for calibration and $R^2=0.9754$ on held-out intermediate dilution levels, while ELISA-equivalent MC estimation yielded $R^2=0.9788$ for calibration and $R^2=0.9786$ on held-out intermediate dilution levels. These results demonstrate the feasibility of transmission-mode MSI as a dual output optical calibration framework for estimation of Microcystis spp. cell concentration and ELISA-equivalent MC concentration in water.

0.27

TuMAP: A Dual-View, Morphotype-Aware Pathomics Pipeline for Quantifying Renal Tubular Remodeling

cs.CV eess.IV ·2026-11-12 ·Ruijie Wu, Yuechen Yang, Yanfan Zhu, Yu Wang, Shilin Zhao +6 more
Abstract · 5 pages, 3 figures, 1 table. Submitted to IEEE ISBI 2027

Quantifying disease-associated renal tubular remodeling is challenging because tubular appearances are heterogeneous. We introduce TuMAP (Tubular Morphotype-Aware Pathomics), a pipeline combining (1) dual-view foundation-model representations and provisional morphotype annotation, (2) compositional and within-morphotype pathomics, and (3) patient-level statistical inference. From 456,158 tubules in 358 PAS-stained kidney biopsy slides, TuMAP identified eight image-based morphotypes, seven of which showed stable subsampling assignments. Across 219 patients in six diagnostic groups, diabetic nephropathy (DN) and tubulointerstitial nephritis/acute tubular injury (TIN/ATI) each differed from minimal change disease in seven morphotype proportions, while IgA nephropathy differed in six. DN showed reduced nuclear solidity and increased eccentricity across all eight morphotypes. Area-normalized nuclear density exposed additional within-morphotype differences. TuMAP provides a framework for separating changes in tubular morphotype composition from phenotypic differences within morphotypes.

0.26

PiLLVD: A Real-World Low-Light Video Dataset for Dynamic Scenes Captured with Off-the-Shelf Cameras

cs.CV eess.IV ·2026-11-12 ·Yaser Abu Awwad, Paul L. Rosin, Oktay Karakuş
benchmarkdataset
Abstract · 14 pages, 7 figures, 5 tables. Dataset available on Zenodo: https://doi.org/10.5281/zenodo.23015904

Low-light image and video enhancement has received increasing attention in recent years. However, most existing enhancement methods are developed and evaluated on still images, while progress in low-light video enhancement remains limited by the lack of real-world paired video datasets. Acquiring paired low-light and normal-light video sequences is challenging because it requires spatially and temporally aligned captures while avoiding motion blur, exposure mismatch, and correspondence errors in dynamic scenes. To address this gap, we introduce PiLLVD, the Pi-based Low-Light Video Dataset, a paired low-light video dataset captured using an accessible Raspberry Pi-based multi-camera system with off-the-shelf cameras. PiLLVD provides paired low-light and aligned normal-light reference sequences for dynamic indoor and outdoor scenes, including diverse human and object motion under varying illumination conditions. Unlike existing datasets that are often image-based, static, synthetic, or limited to simple motion patterns, PiLLVD focuses on motion-rich scenes where frame-to-frame stability and motion-related artefacts are important for evaluation. In addition to presenting the dataset and acquisition pipeline, we benchmark representative pre-trained low-light video enhancement methods on PiLLVD under a zero-shot setting. The results show that existing methods do not generalise uniformly across the proposed sequences, highlighting the challenges posed by the proposed dataset and its value for both benchmarking existing methods and supporting the development of future low-light video enhancement algorithms.

0.22

Context-Predictive Low-Rank Adaptation for Face Presentation Attack Detection

cs.CV eess.IVeess.SPstat.ML ·2026-11-12 ·Aminu Yusuf, Shakeel Muhammad Ibrahim, Sulaimon Oyeniyi Adebayo, Muhammad Sohail Ibrahim, Muhammad Shahid Jabbar +1 more
benchmark
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

Face presentation attack detection requires representations that distinguish physical spoofing cues across changes in acquisition devices, subjects, and attack media. Large visual encoders offer transferable representations, but conventional binary fine-tuning supervises their final decisions without explicitly constraining how local facial evidence is represented under partial observation. We present CP-JEPA, a context-predictive adaptation framework that combines low-rank tuning of a pretrained CLIP image encoder with a joint-embedding predictive objective. A student predicts complete-image teacher features at masked spatial locations, while unmasked classification, masked classification, and prediction consistency retain the connection to the live/spoof task. An exponential-moving-average teacher supplies evolving latent targets. The auxiliary components are used only during training; inference requires only the LoRA-adapted CLIP visual encoder and binary classifier. {We evaluate CP-JEPA under single-source and multi-source OCIM transfer, additional CelebA-Spoof training, transfer to CelebA-Spoof, two-source training, and unseen-attack evaluation on SiW-Mv2.} On the standard OCIM benchmark, CP-JEPA achieves 3.74\% mean HTER and 98.73\% mean AUC. {Single-source evaluation achieves 11.36\% mean HTER across twelve source--target combinations.} With CelebA-Spoof added to the three OCIM training sources, CP-JEPA reduces mean HTER from 3.45\% to 2.35\% and increases mean AUC from 98.68\% to 99.32\%. On SiW-Mv2, it achieves 3.36\% mean HTER across the held-out attack categories. Controlled loss ablations examine the contributions of latent prediction, masked classification, and prediction consistency. The results show that context-predictive adaptation can improve cross-dataset PAD performance, although the gains vary with the training sources and evaluation setting.

0.20

A thorough review on Deep Learning approaches to 2D-to-3D Registration in Medical Imaging

eess.IV cs.CVcs.LGphysics.med-ph ·2026-11-12 ·Andrea Borghesi, Julia van Beurden, Maarten van Alphen, Michiel van den Brekel, Luc Karssemakers +4 more
Abstract · 51 pages, 4 tables, 8 figures

2D-to-3D image registration is a key component for several medical imaging purposes such as intraoperative guidance, enabling the alignment between preoperative 3D volumes and real-time 2D images. While conventional optimisation-based methods often struggle with non-convex objectives, sensitivity to initialisation, and high computational demands, deep learning (DL) has emerged as a promising alternative, offering improved alignment robustness and the potential for real-time performance. This review provides a comprehensive analysis of DL frameworks developed to address the challenges inherent in 2D-to-3D registration. We first outline how core concepts of DL are adapted to the registration problem. We then examine recent methodological advancements from multiple perspectives, including pipeline design, architectural innovations, and domain adaptation strategies. Particular attention is given to quantitative metrics, highlighting how performance is defined and measured across studies. Across the 41 included studies, we find that direct regression is the most common pipeline (23 studies, against 18 iterative ones), that hybrid CNN-attention architectures are gaining ground, and that research remains heavily concentrated on X-ray-to-CT registration. We conclude by identifying the absence of per-case uncertainty estimation and the strong neglect of temporal or sequential modelling as the two methodological gaps most consequential for clinical readiness, and discuss state-space models as a way to add temporal memory within intraoperative latency budgets. Further opportunities lie in more principled domain adaptation and in the integration of foundation models for representation learning.

0.19

CODE-PIF: Convex/Deep (CODE) Multiview Pseudoinvariant Features for Multitemporal Multispectral Surface Reflectance Imagery

eess.IV ·2026-11-12 ·Chia-Hsiang Lin, Lino Garda Denaro, Jian-Kai Huang
Abstract · 14 pages, 6 figures

Multitemporal multispectral surface reflectance imagery exhibits radiometric and spectral variability due to atmospheric effects, sensor differences, and actual surface changes, complicating the identification of pseudoinvariant features (PIFs). The SOTA DeepMGCCA captures nonlinear dependencies across acquisition dates, but similarity in its learned feature space does not directly establish consistency in the original reflectance domain. Meanwhile, we believe that the PIFs extracted by DeepMGCCA preserve essential structural characteristics, providing an effective prior to guide subsequent refinement. Therefore, we propose the CODE-PIF architecture, an unsupervised convex/deep (CODE) framework that refines the coarse PIF from DeepMGCCA using convex optimization. Specifically, CODE-PIF uses the data-fitting term to integrate reflectance deviations, correlation-weighted spectral angles, and temporal reference change information to promote radiometric and spectral consistency between predicted PIFs and observed data. Moreover, the regularization term uses a mathematically simple Q-quadratic norm to incorporate information from the coarse PIF estimate into the refined solution. The resulting convex optimization problem is solved using the ADMM optimizer, which decomposes it into simpler subproblems and provides convergence guarantees under standard assumptions. Experiments across four distinct ROIs show improved average radiometric and spectral agreement relative to DeepMGCCA.Averaged across these regions, the RMSE decreases from 0.0192 to 0.0164, PSNR increases from 35.91 to 37.44 dB, and the between-date spectral angle decreases from 3.77 to 2.97 degrees. Although structural similarity and Pearson correlation do not improve in every scene, the results suggest that using observed data helps select PIFs with more consistent reflectance values and spectral shapes across dates.

0.15

FGCARL: Fisher-Guided Continuously Adaptive Representation Learning for Medical Image Segmentation

eess.IV ·2026-11-12 ·Xiaobing Yu, Jin Yang, Peijie Qiu, Weiwei Ma, Xiaofeng Liu
Abstract · 19 pages, 5 figures

Deep learning (DL) has achieved remarkable success in medical image segmentation by learning data-driven representations from large-scale annotated datasets. However, medical images are often collected independently across clinical sites, resulting in substantial domain shifts due to differences in imaging modalities, acquisition protocols, and intensity distributions. Meanwhile, segmentation classes may vary across sites due to differences in annotation standards, leading to class shifts. These evolving domains and class definitions can substantially degrade segmentation performance on newly encountered data, while sequential adaptation may cause catastrophic forgetting of knowledge acquired from previously encountered domains and classes. Existing incremental learning methods for medical image segmentation primarily address either domain shifts or class shifts, with these two settings largely investigated independently. This separation leaves a critical gap in developing a unified approach that can simultaneously adapt to evolving domains and newly introduced classes while retaining previously acquired knowledge. To address this challenge, we propose Fisher-Guided Continuously Adaptive Representation Learning, a unified framework for domain- and class-incremental 3D volumetric medical image segmentation. FGCARL comprises two key components: Mutual Adaptive Instance Representation (MAIR), which adaptively aligns feature distributions across sequentially encountered domains through bidirectional normalization and denormalization, and Fisher-Guided Knowledge Retention (FGKR), which selectively preserves parameters important for previously learned domains and classes through Fisher-guided regularization. Experimental results demonstrate that FGCARL consistently outperformed state-of-the-art methods, effectively adapting to domain and class shifts while mitigating catastrophic forgetting.

0.14

Angel: Anchor-Structured Neural Gaussians for Explicit Fetal Diffusion MRI Slice-to-Volume Reconstruction with Cross-Subject Learning

eess.IV ·2026-11-12 ·Wenxuan Wu, Lucy Hall, Jonathan O'Muircheartaigh, Joseph V. Hajnal, J-Donald Tournier +1 more
Abstract

Diffusion magnetic resonance imaging (dMRI) provides a noninvasive view of developing tissue microstructure and white matter tracts in the fetal brain. During acquisition, however, fetal motion disrupts spatial correspondence between slices, diffusion encoding directions and signal intensities. We introduce ANGEL, an anchor-structured neural Gaussian framework for accurate slice-to-volume reconstruction (SVR) of fetal dMRI, that simultaneously estimates diffusion signal, fetal motion and intensity artefacts. Unlike standard explicit Gaussian representation, ANGEL is designed to prevent absorption of noise and artefacts into the reconstructed dMRI by learning a compact representation of spatio-angular signal via a shared decoder that predicts 3D Gaussians across anchors and subjects. The individual anatomical variability is compactly represented through subject-specific anchors. Experiments on simulated neonatal and in vivo fetal data show significant improvement of dMRI reconstruction in both spatial and angular domains, in comparison to explicit Gaussian representation, implicit neural representation as well as classical methods.

0.13

RouteDiff: Low-Dose CT Denoising via Fidelity-Refinement Routing and Hypergraph State Regulation

eess.IV cs.CV ·2026-11-12 ·Xinyuan Wang, Ruili Li, Tianyang Li, Yan Li, Xuepeng Liu
Abstract · 16 pages, 10 figures, 7 tables. Submitted to Knowledge-Based Systems

Diffusion models have become a strong prior for low-dose computed tomography (LDCT) restoration. However, existing samplers apply one structure-detail trade-off to the whole image, set the restoration emphasis of each step by the timestep, and derive each next state recursively from the current one, carrying its errors forward. We propose RouteDiff, a state-aware dual-route diffusion framework that routes detail to where it can be trusted, regulates each reverse step by the state it has reached, and re-enters the trajectory from an anchored estimate. Fidelity-Refinement Routing (FRR) equips one shared U-Net with a conservative fidelity route and a detail-oriented refinement route, fuses them pixel-wise with a confidence map, and exposes their disagreement as route evidence. Hypergraph State Regulation (HSR) organizes the current features and this evidence into a state hypergraph, whose soft hyperedges group scattered regions in the same state. Its readout yields an ordered stage judgment that modulates the bottleneck, and its incidence guides feature interaction in the skip connections. Estimate-Anchored Re-entry (EAR) re-projects a route-aware anchor onto the trajectory at a fixed step and hands the new state back to HSR to be judged again. With the ten network evaluations of its baseline, RouteDiff achieves the best peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM) on four datasets with inserted, real and simulated noise (40.95 dB and 95.13% on Mayo 2020; 45.18 dB and 97.23% on Mayo 2016). It also generalizes to unseen doses of real scans and yields the highest Dice (80.92%) in downstream segmentation.

0.12