CS Paper Radar

Daily listing

2026-11-04 · physics.optics

3 papers first submitted this day (UTC) in physics.optics — physics.optics. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 1

Perturbation-Based Reconstruction of Depth-Resolved OCT Attenuation without Requiring a Fully Decayed Signal Tail

eess.IV physics.optics ·2026-11-04 ·Jinglun Yu, Yaning Wang, Shuwen Wei, Jin U. Kang
unusual
Abstract · 26 pages, 10 figures, including 1 supplementary figure. Submitted to Biomedical Optics Express

Depth-resolved attenuation in optical coherence tomography (OCT) can provide quantitative optical contrast beyond structural imaging. However, conventional reconstruction methods can be biased when the OCT signal does not fully decay within the imaging range or when the distal signal tail is dominated by noise or residual reflections from distal sample or support interfaces. Here, we present a perturbation-based Beer-Lambert framework that combines a zeroth-order exponential estimate with a first-order correction, reducing reliance on the unreliable distal signal tail below the current depth. Numerical A-line simulations, Monte Carlo modeling, multilayer silicone-dye-TiO2 phantoms, and ex vivo bovine retina experiments were used to evaluate the method under finite-depth and heterogeneous imaging conditions. The numerical A-line tests showed reduced depth-dependent error against prescribed attenuation profiles; the Monte Carlo comparisons showed less distal drift relative to model-defined benchmarks, while the phantom profiles were compared with separately acquired single-layer OCT calibration values. In a Monte Carlo component test that withheld vessel-mask and vessel-boundary information from reconstruction and used that information only for post hoc evaluation, the first-order correction recovered 61% of the segmentation-informed target vessel contrast and reduced vessel ROI mean absolute error by 65% relative to the fixed zeroth-order baseline. These results suggest that perturbation-based reconstruction may provide a practical approach for depth-resolved reconstruction of effective OCT attenuation when the fully decayed A-line condition is not satisfied.

0.27

Robotics, Control & Signals 2

Single-sided lens terahertz flat-top beam shaping in the Fresnel region

eess.SY physics.optics ·2026-11-04 ·Ehsan Imanbeygi, Mohammad Hossein Koohi Ghamsari, Mehdi Ahmadi-Boroujeni, Babak Honarbakhsh
published
Abstract

In this paper, a novel, to our knowledge, analytical approach is introduced for the design of a single-sided plano-convex lens (PCL) capable of terahertz (THz) flat-top beam shaping in the Fresnel region. The lens profile, derived from geometrical optics principles, integrates collimating and beam-shaping functions into a single optical surface, thereby simplifying fabrication. The efficiency of the method is demonstrated by designing two PCLs that convert a divergent Gaussian beam from a monochromatic THz source (at 100 and 200 GHz) into flat-top beams with target radii of 400 and 500 mm at distances of 3 and 4 m, respectively. The resulting fields, evaluated through analytical, integral equation, and finite element techniques, are shown to be comparable to those produced by a conventional double-sided concave-convex lens. Furthermore, the sensitivity of the design to frequency and alignment variations is investigated, confirming the robustness of this single-curvature approach for integration into practical THz imaging systems.

0.67

Millimeter-Wave Gaussian-to-Flat-Top Beam Shaping Using a Single-Curvature Lens: A Novel Approach

eess.SY physics.optics ·2026-11-04 ·Ehsan Imanbeygi, Mohammad Hossein Koohi Ghamsari, Mehdi Ahmadi-Boroujeni
published
Abstract

This paper presents a novel method for converting the divergent Gaussian intensity distribution of a millimeter-wave source into a uniform (flat-top) distribution using a single curved surface. The proposed method combines the surface profile of a collimator with that of a beam shaper. To validate the method, the profile of a single-sided (plano-convex) lens is derived and placed 52 mm in front of a conical horn antenna operating at 100 GHz. The lens transforms the Gaussian radiation of the horn, with an incident beam radius of 11.9 mm, into a uniform beam with a radius of 400 mm at a distance of 3 m. The lens surface profile is optimized using a full-wave-simulation-based procedure, and the resulting output beam is compared with that of a previously designed double-sided (concave-convex) lens. Simulation results show that, within the desired field of view, the optimized single-sided lens produces a flat-top intensity distribution with satisfactory ripple and roll-off. Finally, the sensitivity of the optimized lens to frequency variation is investigated. The proposed lens is suitable for generating uniform illumination in active stand-off millimeter-wave imaging systems.

0.46