CS Paper Radar

Uncertainty-Aware Compositional Localization and Placement Assessment of Catheters and Tubes in Chest X-Rays

Harshil Lodhiya

eess.IV cs.CVcs.LG ·submitted 2026-08-11 16:04 UTC · v2

Abstract

Assessing catheter and tube placement on chest X-rays is safety-critical yet tedious and error-prone. Current deep learning methods either classify placement globally -- losing track of which device is where -- or segment all devices into a single mask, making per-device assessment impossible when catheters overlap. We introduce UCompCXR, a compositional framework that detects local catheter fragments, associates them into device instances via graph-based clustering, fuses per-fragment tip predictions through precision-weighted Gaussian estimation, and classifies placement per device. On the RANZCR CLiP dataset (30,083 images, 5-fold patient-level CV with bootstrap CIs), UCompCXR detects 26% more devices than a strong multi-task baseline sharing the same MobileNetV3 backbone, with 75% fewer false positives and well-calibrated tip uncertainty (95% coverage = 0.948). The aggregate tip error rises -- but only because the model finds devices the baseline misses entirely, especially nasogastric tubes. On matched devices, catastrophic localization failures drop substantially. At 2.27M parameters in a single forward pass, the model is deployable on resource-constrained clinical hardware.

Comment
21 pages, 8 figures Included declaration for paper is under consideration at Pattern Recognition Letters

Closest papers

Nearest neighbours by meaning across the whole index.

Beyond Accuracy: Quantifying Pulmonary Attribution in Anatomy-Guided Chest X-Ray Classification Under Domain Shift

cs.CV ·2026-08-31 ·Abdullah Al Mamun, Md. Nasif Osman Khansur, Md Ashraful Hossen Akash, Md. Kishor Morol, Tze Hui Liew
code/data similarity 0.66
Abstract · 34 pages, 8 figures, 7 tables. Code available at https://github.com/Abdullah-229/BeyondAccuracy

Deep-learning models can achieve strong chest X-ray (CXR) classification performance without establishing whether their predictions predominantly rely on pulmonary image content. This study evaluates pulmonary attribution containment as an anatomy-related reliability property distinct from diagnostic performance. We propose DBCA-SegNet-MGAP, a multi-task anatomy-guided CNN-Transformer framework that combines complementary feature representations through bidirectional cross-backbone attention, predicts a soft lung mask, and incorporates this anatomical prior directly into classification through Mask-Guided Adaptive Global Average Pooling (MGAP). Pulmonary attribution containment is quantified using the Anatomical Local Energy Ratio (ALR) and high-intensity cumulative ALR (cALR@0.9). Experiments were repeated across three training seeds using the COVID-19 Radiography Database for four-class internal testing and a locked Shenzhen-to-Montgomery protocol for zero-shot external tuberculosis testing. On COVID-19, the proposed model achieved a weighted F1 of $0.9615 \pm 0.0015$ and macro ROC-AUC of $0.9906 \pm 0.0007$. In an architecture-matched dual-bridge comparison, replacing conventional GAP with MGAP increased ALR from $0.3878 \pm 0.0098$ to $0.7086 \pm 0.0104$ and cALR@0.9 from $0.5265 \pm 0.0101$ to $0.9905 \pm 0.0018$, while weighted F1 remained essentially unchanged ($0.9618 \pm 0.0015$ vs. $0.9615 \pm 0.0015$). Under locked external transfer to Montgomery, ROC-AUC remained $0.9080 \pm 0.0043$ and pulmonary ALR remained $0.6466 \pm 0.0081$, whereas weighted F1 decreased to $0.7528 \pm 0.0080$ and ECE increased to $0.1683 \pm 0.0055$. These findings show that diagnostic discrimination, calibration, and pulmonary attribution containment are distinct model properties and support their joint evaluation under internal testing and external domain shift.

0.52

Clinical Knowledge Graphs for Chest X-Ray Device Reasoning

cs.AI cs.CV ·2026-08-25 ·Harshil Lodhiya
similarity 0.64
Abstract · 19 pages, 2 figures, 5 tables. Post-hoc descriptive analysis on archived RANZCR CLiP test predictions

Chest radiographs are routinely used to verify the position of catheters, tubes, and other support devices. Existing image models often return labels or segmentations, while report-processing systems structure text without access to image geometry. We present an uncertainty-aware clinical knowledge graph that represents device instances, tip estimates, placement assessments, provenance, report events, and temporal links as separate but connected evidence. We evaluate the implemented visual graph layer using saved predictions from the complete RANZCR CLiP test archive, comprising 30,083 studies from 3,255 patients across five non-overlapping outer folds. The graph builder materializes 914,632 B7 evidence nodes and 884,549 typed relationships. All 118,647 B7 predicted-device nodes retain tip covariance, placement probabilities, fragment provenance, and fragment counts, whereas the direct B2 baseline retains none of these fields. We further define typed data contracts, uncertainty representations, abstention rules, report-image grounding, and longitudinal query mechanisms for extending the graph to report-bearing cohorts. The reported graph-materialization analysis is post-hoc descriptive and does not establish report grounding, longitudinal performance, or clinical utility. It demonstrates a reproducible foundation for evidence-preserving AI reasoning over chest X-ray device assessments.

0.18

SPARCL: Spatially Adaptive Regional Coverage for Active Learning in Chest X-ray Analysis

cs.CV cs.LG ·2026-10-13 ·Juho Jung, Seongjae Kang, Mijoo Kim, Sungduk Cho, Yunkyoung Jun +2 more
similarity 0.63
Abstract · 10 pages, 7 figures

Pixel-level annotation for chest X-ray (CXR) lesion segmentation is expensive, making active learning (AL) essential. However, existing AL strategies fail to account for the spatial distribution of selected samples, resulting in inconsistent performance across focal (e.g., aortic calcification) and diffuse (e.g., nodules) pathologies. In this paper, we propose SPARCL (Spatially Adaptive Regional Coverage for Active Learning) to dynamically balance predictive uncertainty with cumulative spatial coverage. By employing a concave coverage function, SPARCL imposes diminishing returns on previously annotated regions, naturally directing the annotation budget toward under-labeled areas. Furthermore, an entropy gate reverts the algorithm to standard uncertainty sampling when spatial variation is absent. This coverage objective is monotone submodular, guaranteeing near-optimal greedy batch selection. To address how aggregate metrics like Dice obscure regional failures, we further introduce two metrics---Spatial Inconsistency (SI) and Performance Coverage (PC)---to quantify anatomical fairness across AL rounds. Evaluated on an in-house calcification cohort and public CXR benchmarks, SPARCL reaches 95% of fully supervised performance using only 24% of the data, compared to 29% for the best baseline. Ultimately, SPARCL ensures robust spatial reliability, surfacing regional gains that aggregate metrics miss.

0.25

Revealing Hidden Failure Modes in Chest X-ray Classification via Spectral Domain Analysis

cs.CV ·2026-10-21 ·Samuel Halimi, Loic Themyr, Arnaud Abreu
published similarity 0.63
Abstract · MIDL 2026 https://proceedings.mlr.press/v315/halimi26a.html

Deep learning models for chest X-ray anomaly detection remain vulnerable to subtle distributional shifts (e.g., acquisition technique, patient-related factors, and preprocessing). Traditional error analysis often relies on semantic metadata or model embeddings, which can mask low-level signal variations that degrade performance. In this work, we propose a data-centric framework for automated failure mode discovery using spectral analysis. We project images into the frequency domain and extract a compact profile summarizing the distribution of signal energy across frequency bands. By performing unsupervised clustering on these spectral profiles, we demonstrate that model failures are not randomly distributed, but are strongly concentrated within specific spectral clusters. This method effectively isolates "blind spots", enabling the prediction of model reliability and the discovery of performance-degrading data slices without requiring ground-truth failure annotations.

0.62

PCXR-Copilot: Device-aware pediatric chest radiographic analysis with segmentation, suppression, and edema-related cues

cs.CV ·2026-10-18 ·Xueyang Li, Alec Girten, Peng Zeng, Mingze Jiang, Shaoyang Huang +4 more
similarity 0.62
Abstract

Patients admitted to pediatric ICU and cardiac ICU often require intensive perioperative support and frequent chest radiography to monitor support devices, extravascular lung water, and body-wall edema. Radiographic interpretation and analysis is often difficult due to superimposed anatomic and iatrogenic structures that obscure clinically relevant signals. While deep learning can provide decision support, translation to pediatric radiographs is still limited by high device burden and scarcity of pediatric datasets with clinically grounded device annotations. To address this gap, we first introduce PediaDeviceSeg-1K, a curated dataset of 1,000 anterior-posterior radiographs of pediatric CICU patients with clinically grounded, fine-grained annotations of common ICU devices. To our best knowledge, this is the first publicly available pediatric CICU CXR resource with clinically grounded device annotations for device-focused benchmarking. Building on PediaDeviceSeg-1K, we further present PCXR-Copilot, a device-aware pipeline that outputs lung and device masks, optional device-suppressed views, and edema-related visualization maps and scalar indices. The full pipeline has been integrated and runs in real time within the TWIST platform at Boston Children's Hospital, demonstrating feasibility for real-world clinical deployment.

0.11

Cross-dataset transportability of pediatric chest X-ray deep learning across three countries: discrimination, calibration, operating-point failure, and limited-label recovery

eess.IV cs.CV ·2026-09-04 ·Nazim-E-Alam
similarity 0.62
Abstract

Background and Objective: External evaluation of medical-imaging AI is often collapsed into discrimination. We evaluated a computational protocol that separately tests discrimination, probability calibration, fixed operatingpoint transport, shortcut-associated signal, and limited-label recoverability for pediatric pneumonia classification across datasets from three countries. Methods: After exact-duplicate removal, 5,824 Guangzhou radiographs supported leakage-controlled source development and internal testing. A frozen three-seed DenseNet121 dual-view ensemble was evaluated zero-shot on BDCXR-3257 from Bangladesh (n = 3, 257) and an untouched harmonized VinDr-PCXR/PediCXR test cohort from Vietnam (n = 1, 077). Matched seed-42 variants tested architectural robustness. Secondary BDCXR analyses used a fixed 651-image adaptation pool and 2,606-image hold-out; 163, 326, and 651 labels represented 5%, 10%, and 20% of complete BDCXR. Results: Internal AUROC was 0.976 with 95.1% sensitivity. BDCXR and VinDr-PCXR AUROC were 0.798 and 0.742, while frozen-threshold sensitivity fell to 6.2% and 0%. Source-to-BDCXR AUROC degradation occurred for a full-image baseline (0.961 to 0.749), ungated dual-view model (0.977 to 0.766), and gated MixStyle model (0.966 to 0.789). With 163 BDCXR labels, Platt recalibration preserved AUROC while increasing held-out sensitivity to 88.3%, but specificity was 47.9% and the alert rate was 78.5%. Two hundred repeated 163-label fits confirmed sensitivity recovery but substantial specificity variability. Conclusions: Cross-dataset shifts across countries affected ranking, probability alignment, and source-defined decision behavior differently. Transport studies should evaluate these components separately and quantify the operational burden of apparent recovery.

0.06

Look What the Probes Dragged In! Real-World Chest X-ray Shortcuts in MedCLIP

cs.CV cs.LG ·2026-08-12 ·Nikolette Pedersen, Regitze Sydendal, Veronika Cheplygina, Théo Sourget
publishedcode/data similarity 0.62
Abstract · 11 pages, 3 figure, poster presentation at the joint FAIMI, BRIDGE, and EPIMI workshop at MICCAI 2026 (Strasbourg, France) conference

Vision-language models, such as contrastive language-image pre-training (CLIP)-based approaches, have reached state-of-the-art (SOTA) results in medical artificial intelligence. However, recent work reveals that CLIP-based models remain vulnerable to shortcuts. We investigate how real-world shortcuts manifest across different layers of the medical CLIP-based model, MedCLIP, and its vision encoder, a frozen ResNet-50. We attach 17 linear classification probes to the intermediate layers of the ResNet-50 and train them on three different dataset configurations and targets: NIH-CXR14 (pneumothorax) and PadChest (cardiomegaly and pneumothorax). This setup allows us to observe model behaviour during evaluation using subgroup-based calibration and layer-wise confidence curves. We find that the final linear probes achieve a high AUROC but poor calibration in the models. The layer-wise confidence analyses suggest that shortcuts emerge at different depths. Patterns consistent with localised shortcuts, such as drains, appear at later layers, while patterns consistent with diffuse shortcuts, such as scanner-specific noise patterns, emerge earlier, aligning with previous work. Finally, we conduct a manual analysis of the images, which reveals data quality issues in both NIH-CXR14 and PadChest. Our findings underscore that even SOTA models remain vulnerable to shortcuts, and the need for high-quality and well-annotated datasets to draw solid conclusions. Code can be found on our GitHub: https://github.com/nikodice4/MedCLIP_shortcuts.

0.43

MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation

cs.CV cs.AI ·2026-10-02 ·Jiaying Li, Paolo Remagnino
top venue similarity 0.62
Abstract

Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

0.32