CS Paper Radar

CG-GLORE: A Conjugate Gradient-Based Global-Local Regularization Network for Sparse-View CT Reconstruction

Tran Xuan Hieu Le, Doanh C. Bui, Vu Trung Duong Le, Hoai Luan Pham, Khang Nguyen, Mai K. Nguyen, Tu Bao Ho, Yasuhiko Nakashima

cs.CV cs.AI ·submitted 2026-08-15 14:08 UTC · v1
published

Abstract

Sparse-view computed tomography (CT) reduces radiation dose by acquiring fewer projection views, but the resulting inverse problem is highly ill-posed and often produces severe streak artifacts. Existing deep reconstruction methods have achieved promising performance, yet many rely on first-order updates or large regularization networks, which can be less effective in ill-conditioned settings. We propose \textbf{CG-GLORE}, a compact deep unrolling framework inspired by second-order optimization for sparse-view CT reconstruction. Each unrolled stage uses a CG-solved linear system based on a structured Hessian surrogate: it retains the physics-induced curvature of the data-fidelity term while using an identity approximation for the learned regularization term. Thus, the method is second-order-inspired rather than an exact Newton method for the full learned objective. To model image priors, we design a Global-Local Regularization Network (GLORE), which combines convolutional local feature extraction with a Long-Range Dependency Representation module based on sparse patchification and Nyström attention. This design captures anatomical details and non-local dependencies while maintaining practical complexity. Experiments on AAPM and DeepLesion under multiple sparse-view and noise settings show that CG-GLORE achieves strong quantitative performance, stable convergence, lower noise power, and improved visual fidelity compared with representative reconstruction methods.

Comment
Accepted for presentation at BMVC2026

Closest papers

Nearest neighbours by meaning across the whole index.

Taming Neural Fields with a Frequency-Lipschitz Curriculum for Sparse-View CT Reconstruction

cs.CV cs.LG ·2026-11-11 ·Songtao Hu, Jingrui Wu, Hong Ding, Fanhao Zhu, Yunhao Liu +1 more
similarity 0.78
Abstract

Sparse-view computed tomography (SVCT) reduces radiation dose by acquiring fewer projection views, but the resulting under-determined inverse problem requires careful regularization to prevent reconstruction algorithms from fitting streak artifacts and hallucinated structures. Existing implicit neural representation (INR) methods rely on implicit spectral bias or iterative external denoising, yet they provide limited control over when high-frequency capacity is exposed during optimization. To address this limitation, we propose FLIC (Frequency-Lipschitz INR Curriculum), a capacity-controlled self-prior INR framework that makes the network's representational capacity explicit and schedulable. The core of our method is a joint frequency-Lipschitz curriculum that couples random Fourier feature encoding with spectrally normalized MLP decoding under non-uniform Lipschitz budgets, guiding reconstruction along a coarse-to-fine trajectory from stable global anatomy to fine details. The terminal capacity is automatically calibrated from FBP gradient statistics, enabling scan-adaptive regularization without per-scan manual tuning of the terminal Lipschitz budget. We further introduce a prior-guided adaptive ray sampling strategy that concentrates integration samples near high-gradient anatomical boundaries, improving forward-model fidelity. The entire framework operates in a single training stage without iterative denoising, enabling efficient per-image reconstruction. Extensive experiments on four public CT datasets under noise-free and low-dose settings show that our method achieves state-of-the-art unsupervised reconstruction quality with consistent performance across diverse anatomical structures.

0.13

Extremely Sparse-View Computed Tomography from 2D Projections via Pose-Aware Diffusion Priors

cs.CV cs.AI ·2026-10-28 ·Linrui Dai, Jinxiu Liang, Chu Zhou, Mae Yamaguchi, Ryuya Takahashi +1 more
published similarity 0.74
Abstract · NeurIPS 2026 poster

Extremely sparse-view computed tomography (xSV-CT) is critical when scanning time, motion, or radiation tolerance limits each scan to only a few projections. In many such scenarios, the same acquisition limits also constrain dataset construction, making pre-reconstructed 3D volumes from dense scans unavailable. This exposes a gap in current sparse-view approaches: Optimization-based methods, which use the sparse measurements directly but lack data-driven priors to suppress artifacts, and learning-based methods, which use strong priors but usually require densely scanned training volumes acquired outside the xSV-CT regime. We study this train-sparse / infer-sparse setting by learning a pose-aware diffusion prior from one 2D projection per training sample, then guiding diffusion sampling with measured-view fidelity, shared-volume reprojection, and projection-physics consistency for tomographic reconstruction. On two public CT datasets across 1-, 4-, and 8-view settings, the proposed method achieves the best novel-view synthesis scores and best or competitive reconstruction quality compared with baselines that use dense-volume supervision.

0.26

PhyDiCT: Plug-and-Play CT Reconstruction from Sparse X-Rays via Differentiable Rendering and Strong Priors

cs.CV ·2026-10-07 ·Weicheng Dai, Shantanu Ghosh, Kayhan Batmanghelich
top venuecode/data similarity 0.72
Abstract · Accepted at MICCAI 2026; to appear in LNCS 16888

Reconstructing 3D Computed Tomography (CT) images from a few X-ray projections is a highly ill-posed inverse problem due to the loss of volumetric information. We propose PhyDiCT, a training-free framework that integrates a differentiable Physics-based forward model, grounded in the Beer-Lambert law, with a text-conditioned Diffusion as a strong prior to reconstruct 3D lung CT images. We refer to our approach as training-free since the prior model is used without fine-tuning, and our goal is to steer the denoising procedure to generate samples consistent with X-ray observations. We guide the diffusion generation using Split Gibbs sampling to jointly optimize for projection fidelity (reward) and consistency with prior knowledge. Also, we introduce a test-time refinement step that enhances image realism and anatomical coherence. We extensively evaluate our method on publicly available 3D CT datasets using both perceptual and semantic metrics, demonstrating that it surpasses existing plug-and-play diffusion and fully trained reconstruction approaches. Our findings highlight that combining a strong generative prior with the underlying physics of image formation substantially improves reconstruction quality, e.g., 7.5\% improvement on SSIM compared to full training methods. Code will be released at https://github.com/batmanlab/PhyDiCT.

0.44

Accelerating Variational Cone-Beam CT Reconstruction with Learned Warm Starts

eess.IV cs.AIcs.CV ·2026-11-13 ·Héloïse Dudoignon, Clément Delmas, Laurent Facq, Clair Poignard, Baudouin Denis de Senneville
similarity 0.71
Abstract · Submitted to IEEE ISBI 2027

Variational reconstruction provides a rigorous framework for cone-beam computed tomography (CBCT) by combining an explicit acquisition model with image priors. However, iterative optimization remains computationally demanding, particularly under severe noise and sparse-view conditions. Although learning-based methods achieve high reconstruction quality, they often replace the original variational formulation with learned optimization schemes or nonlinear equilibrium models. We propose a neural network-guided warm-start framework that accelerates variational reconstruction while preserving its original formulation. Projection data are first reconstructed using the Feldkamp-Davis-Kress (FDK) algorithm, and the resulting image is refined by an image-domain neural network. The network output is used solely to initialize the subsequent model-based optimization, leaving the forward model, data-fidelity term, regularization, and optimization scheme unchanged. A pre-regularization step further improves compatibility with the variational priors. Experiments on pelvic CT images from the SynthRAD2025 challenge show a more than threefold reduction in reconstruction time while maintaining comparable image quality.

0.21

AD-GS: Anatomical Density-guided 3D Gaussian Splatting for Sparse-View Dental CBCT Reconstruction

cs.CV ·2026-10-10 ·Zonglin Li, Kexian Xie, Feiran Li, Chu Zhou, Yixing Huang +3 more
code/data similarity 0.71
Abstract

Sparse-view Cone-Beam Computed Tomography (CBCT) reconstruction is essential for reducing radiation dose and scan effort, but remains underconstrained due to limited projection information. Recent 3D Gaussian Splatting (3DGS)-based CBCT reconstruction methods rely on gradient-driven densification, which becomes unstable under sparse acquisition and often leads to over-smoothed structures. We propose AD-GS, an Anatomical Density-guided 3D Gaussian Splatting framework that formulates Gaussian densification as an attenuation-aware Markov Chain Monte Carlo (MCMC) sampling process. By interpreting Gaussians as samples from an underlying anatomical attenuation distribution, AD-GS adaptively concentrates representation capacity in high-attenuation regions, enabling sharper structural boundaries under sparse projections. To further constrain reconstruction, we incorporate a semantic regularization based on zero-shot features from Segment Anything in Medical Images, enforcing multi-view consistency through semantic priors. Experiments on the ToothFairy3 dental CBCT dataset demonstrate that AD-GS achieves superior structural fidelity and boundary preservation compared with existing 3DGS-based approaches under sparse-view settings within the dental and maxillofacial setting. Code is available at https://github.com/yulinjiaxue/AD-GS-BMVC2026.

0.29

Feed-Forward Hierarchical Gaussian Diffusion for Extreme CT Reconstruction

cs.CV ·2026-08-15 ·Yuezhe Yang, Li Cheng
benchmarkcode/data similarity 0.69
Abstract

Reconstructing three-dimensional computed tomography (CT) from severely constrained projections is highly ill-posed. Sparse angular sampling, restricted angular coverage, and low photon counts can occur individually or jointly, obscuring global anatomy and local tissue detail. Many learned CT reconstruction methods are tailored to a single dominant degradation. Existing diffusion and Gaussian approaches commonly recover global structure and local detail within a shared representation. We propose HiGDiff, a feed-forward hierarchical Gaussian diffusion framework that decomposes reconstruction both spatially and from structure to detail. Physics-conditioned anatomical anchors and a foreground capacity field allocate learnable Gaussian primitives to informative regions. A structure diffusion stage first recovers global attenuation geometry, and its learned representation conditions a detail diffusion stage for residual boundaries and tissue transitions. The resulting Gaussian banks are rendered as attenuation fields and further refined by a gradient-isolated residual module. Experiments on three distinct CT benchmark datasets demonstrate state-of-the-art reconstruction performance across isolated, paired, and joint degradation settings, including improvements of 5.81 dB in macro-average peak signal-to-noise ratio (PSNR) and 0.113 in structural similarity index measure (SSIM) on the Low Dose CT Image and Projection Data (LDCT-PD) collection. Code and experimental configurations are openly available at https://github.com/Bean-Young/HiGDiff.

0.24

TomoTransformer: Towards a Foundation Model for CT Reconstruction

cs.CV cs.LG ·2026-09-29 ·AmirEhsan Khorashadizadeh, Benjamín Béjar
benchmark similarity 0.69
Abstract

Supervised deep learning has advanced sparse-view tomographic reconstruction. However, conventional models, which typically map filtered back-projection (FBP) images or sinograms to clean reconstructions, are brittle under distribution shifts. Because they require retraining whenever projection counts and angles, detector resolutions, or data distributions change, their deployment in real-world applications remains limited. To address this, we introduce TomoTransformer, a transformer-based architecture that treats each \textit{local} filtered projection as an individual token and predicts missing views via self-attention. Crucially, TomoTransformer operates in a \emph{back-projection space} that separates projections across spatial locations, making view interpolation geometrically well-posed and invariant to detector size. This design yields a single foundation model that can process any number of input projections, at arbitrary angular locations and detector dimensions, and query any number of target angles without retraining. Trained on a large-scale dataset spanning diverse medical CT anatomies and natural images, TomoTransformer generalizes effectively across anatomies, materials, and resolutions. Extensive evaluations on several benchmark sparse-view datasets show that TomoTransformer significantly outperforms concurrent multi-purpose models like ViewTrans and matches or exceeds strong protocol-specific baselines, while remaining fully agnostic to the number of input and target projections. Furthermore, the model demonstrates robust zero-shot generalization on real experimental nanoscale brain data collected from an X-ray synchrotron, showcasing its practical utility for real-world applications.

0.19

Coarse-to-Fine Diffusion with Residual Prior for Low-Dose CT Denoising

eess.IV ·2026-09-30 ·Ping Wu, Pengcheng Zheng, Jiahao Zhang, Bohao Chen, Yazhou Ren +1 more
similarity 0.68
Abstract · 10 pages

Low-dose CT (LDCT) reduces radiation exposure but often introduces severe noise and streak artifacts that obscure subtle anatomical structures. Existing diffusion-based denoising methods commonly rely on implicit assumptions about the noise distribution, which may not hold in practical LDCT scenarios and can degrade denoising performance. To address this limitation, we propose a Residual-Guided Diffusion framework that effectively incorporates an explicit difference prior to inform the diffusion process of noise distribution. The difference prior is computed as the residual between the LDCT image and a coarse clean estimate, constraining diffusion sampling to a plausible residual space. We further adopt a coarse-to-fine strategy in which a pre-trained RED-CNN provides the coarse estimate to anchor global anatomy, and the diffusion model refines the remaining details under the prior guidance. For efficiency, we employ accelerated sampling with 20 steps at inference. Experiments on three representative datasets demonstrate that our approach outperforms existing methods in both quantitative and qualitative performance measures.

0.14