CS Paper Radar

Population Structure Analysis of an Inbred Population using Quantitative Shape Phenotyping from Stereo Retinal Photographs

Li Tang, Michael D Abramoff

cs.LG cs.CVq-bio.QM ·submitted 2026-08-16 01:30 UTC · v1

Abstract

The population structure of an inbred population of 781 people on Norfolk Island in the Pacific, 318 of which are descendants of the original Mutineers of the Bounty, is analyzed phenotypically using shape from stereo retinal fundus photographs. Three-dimensional optic nerve head (ONH) shape is reconstructed from stereo pairs by a multi-scale stereo matching algorithm. Using deep neural network, the shape of ONH, which is under genetic control, is decomposed into a set of hierarchical features through self-taught learning. Features captured at different levels are selected according to their discriminant power in identifying the two populations. The prediction accuracy is evaluated with stratified cross validation. Given the selected feature set, individuals are grouped into k hierarchical clusters and cluster membership fractions are determined for k=2,3,4,5,6,7. Population structure analysis on the basis of phenotypes through image analysis allows heritability and linkage analysis, including founder effects from English and Polynesian ancestors, potentially leading to new genetic risk factors for glaucoma and other ONH-related eye diseases.

Closest papers

Nearest neighbours by meaning across the whole index.

Detecting Glaucoma Across Multi-ethnic Myopic and Non-Myopic Populations Using an Uncertainty-Aware Vision Transformer: A Multicentre Model Development and Validation Study

cs.CV cs.AI ·2026-09-24 ·Raghavan Lavanya, Yangqin Feng, Ten Cheer Quek, Quan V. Hoang, Linda Yi-Chieh Poon +34 more
similarity 0.60
Abstract

Background: Artificial intelligence (AI)-based glaucoma detection from colour fundus photographs (CFP) offers scalable screening, but performance may decline on external datasets because of differences in ground-truth definitions, populations, and coexisting conditions such as high myopia (HM). We developed and validated a Vision Transformer-based deep learning (DL) model for glaucoma detection across multi-ethnic cohorts with and without HM. Methods: A ViT-B/16 model with predictive uncertainty estimation was developed using 56,483 CFPs (57.1% with myopia; 14.4% with HM). Glaucoma labels were standardised using clinical, imaging, and perimetry data. The model was validated on 16 independent datasets across three continents, including four datasets with explicit HM labels. Findings: Internal AUROC was 98.7% (95% CI 98.2-99.1%), with sensitivity 94.5% and specificity 97.3%. Across 16 external datasets from eight countries, AUROCs ranged from 86.4% to 99.6%. In HM eyes, internal AUROC was 97.8% (95% CI 96.1-99.2%), with sensitivity 94.8% and specificity 93.7%. External HM AUROCs were 86.5% in the Beijing Eye Study and 93.3%, 91.8%, and 85.5% in hospital-based datasets from Taiwan, Thailand, and South Korea. In an exploratory HM clinical evaluation, the model had higher CFP-only diagnostic accuracy than ophthalmologists and trained graders (92.0% vs 70.0%; p=0.008) and performed comparably to glaucoma specialists using full clinical information. Interpretation: The model showed robust glaucoma detection across myopic and non-myopic multi-ethnic populations and may support AI-assisted screening in settings with high HM prevalence.

0.28

Robust retinal biometrics for patient identity verification and retrieval across age and imaging devices

cs.CV ·2026-08-31 ·Jose D. Vargas-Quiros, Dennis Bontempi, Jeroen Vermeulen, Bart Liefers, Sven Bergmann +1 more
similarity 0.59
Abstract

Patient identity errors can compromise longitudinal medical records, research databases, and downstream clinical decisions. We present a retinal biometric system for verifying claimed identities and retrieving the correct identity from color fundus images. We trained a 512-dimensional metric-learning encoder combining a ConvNeXtV2 backbone with ArcFace and triplet losses on 227,004 images from 21,851 patient-eye identities in the Rotterdam Study, spanning multiple imaging devices and up to 32.6 years of follow-up. The system was evaluated on held-out Rotterdam Study data and externally on the UK Biobank and Age-Related Eye Disease Study (AREDS). Before evaluation, we used the model to screen for identity inconsistencies and manually adjudicated flagged images, identifying incorrect assignments in 0.588% of Rotterdam Study images, 0.259% of UK Biobank images, and 0.164% of AREDS images. In retrospective-only verification after removing near-duplicate images, the system achieved AUROCs of 0.9998, 0.9997, and 0.9998 in the Rotterdam Study, UK Biobank, and AREDS, respectively. For identity retrieval using only previously acquired images, Recall@1 was 99.7%, 97.2%, and 97.6%, respectively, from galleries averaging 4436-8510 identities; the correct identity appeared among the top five results in at least 98.6% of cases. Performance remained robust across imaging devices and long follow-up intervals, while lower image quality and inconsistent retinal fields accounted for most failures. These findings establish retinal anatomy as a durable biometric signal, useful for safeguarding the integrity of longitudinal imaging records.

0.14

International Multi-Centre Validation of Unsupervised Domain Adaptation for Precise Discrimination between Normal and Abnormal Retinal Development

cs.CV cs.LG ·2026-10-15 ·Zhanhan Tu, Nikhil Reddy, Helen J. Kuht, Ha-Jun Yoon, Gail D. E. Maconachie +25 more
similarity 0.55
Abstract · Submitted to Nature Medicine. 38 pages, 6 figures, 2 tables. Supplementary material includes 3 figures and 3 tables

Arrested retinal development can cause childhood visual impairment, but grading optical coherence tomography scans is difficult to standardise across devices and centres. We developed and evaluated an unsupervised domain adaptation model to classify normal and abnormal retinal development across different OCT systems. This retrospective multicentre study used OCT scans from five centres in four countries and the UK Biobank. Data covered four OCT devices, including table mounted and handheld systems. A ResNet50 based Domain Adversarial Neural Network was trained using labelled images from a source device and unlabelled images from a target device. We evaluated six source to target pairings and compared model performance with seven clinician graders. A separate Heidelberg Spectralis dataset was reserved for external evaluation. Across validation sets, accuracy ranged from 87.75% to 96.06%, sensitivity from 88.68% to 98.38%, and specificity from 78.00% to 98.02%. The best performing model, adapted from TM OCT1 to HH OCT1, achieved 96.06% accuracy and an area under the receiver operating characteristic curve of 0.994, with a 95% confidence interval from 0.981 to 0.999. Several models also maintained discrimination on the unseen Heidelberg device. Unsupervised domain adaptation enabled OCT classification across devices without labelled target device data. The approach may support more consistent assessment of retinal development and large scale analysis of existing imaging datasets.

0.34

Learning Pathology-Sensitive Representations for Unsupervised Retinal OCT Anomaly Detection

cs.CV cs.LG ·2026-10-23 ·Tania Haghighi, Sina Gholami, Behafarin Emam, Jennifer I Lim, Theodore Leng +3 more
similarity 0.52
Abstract

Deep learning approaches for retinal optical coherence tomography (OCT) predominantly rely on predefined disease categories, limiting their ability to detect rare or previously unseen abnormalities. While visual foundation models provide transferable representations, their effectiveness in identifying pathological deviations from normal retinal anatomy remains insufficiently understood. In this work, we introduce an unsupervised framework for retinal OCT anomaly detection and localization that adapts pretrained visual representations to normal retinal anatomy through anatomy-aware reconstruction and contrastive triplet learning guided by synthetic structural perturbations, without requiring disease-specific annotations. We systematically investigate the influence of pretraining strategies, anatomy-aware representation adaptation, and anomaly scoring mechanisms on the detection and localization of unseen retinal abnormalities. Our findings demonstrate that adapting pretrained representations to normal retinal structure improves anomaly sensitivity, while pixel-space reconstruction errors and feature-space deviations provide complementary signals for identifying pathological changes. These findings underscore the importance of anatomy-aware representation learning and offer insights into developing generalizable retinal anomaly detection frameworks beyond predefined disease categories.

0.30

Interpretable AI plus Handheld, Portable Retinal Photographs: A Low-Cost Glaucoma Screening Solution for West Africa

cs.CV cs.AI ·2026-09-22 ·Charis Y. N. Chiang, Tarela Sarimiye, Adeyinka Ashaye, Martin Buist, Michael A. Hauser +2 more
similarity 0.52
Abstract · 31 pages, 2 Tables, 5 Figures, 1 Supplementary Material

Purpose: To develop and evaluate an interpretable artificial intelligence (AI) framework for glaucoma screening from low-cost portable, handheld retinal fundus photographs in a West African population and to compare its performance with clinical tabletop fundus imaging. Methods: We used data from a community-based study of 681 participants (1,362 eyes) in Nigeria, comprising 414 glaucoma, 478 glaucoma suspect, and 470 non-glaucoma eyes. Fundus photographs were acquired using the low-cost handheld, portable Volk Viva retinal camera and the Canon CR-2-AF tabletop camera. We fine-tuned component models separately to each device to perform vessel segmentation, cup and disc boundary segmentation, and feature extraction to detect optic nerve head features. A final classification model combined these components to classify scans as glaucoma, glaucoma suspect or non-glaucoma. Feature-weight analysis and Gradient-weighted Class Activation Mapping were used for interpretation. Results: The models performed well on both Volk Viva and Canon CR-2-AF images: Vessel segmentation: 0.98 Dice Coefficient (DC) (Volk) and 0.94 DC (Canon); Cup and disc segmentation: 0.95 DC (Volk) and 0.96 DC (Canon); Optic nerve head feature detection: area under the receiver operating characteristic curve (AUCs) of 0.83$\pm$0.03 (Volk) and 0.87$\pm$0.04 (Canon); Classification model: AUCs of 0.85$\pm$0.01 (Volk) and 0.93$\pm$0.01 (Canon). Reports for each image, present model decision confidence scores and decision-rationale visualizations to support clinical interpretation. Conclusions: Volk Viva results were reasonably comparable to Canon CR-2-AF in the component models and not far behind in classification. This shows that interpretable AI combined with low-cost, portable imaging may enhance community-level glaucoma screening, especially in settings with limited specialist access and resources.

0.32

Where to Predict in Retinal OCT? Anatomy-Guided Target Selection for I-JEPA

cs.CV ·2026-11-12 ·Yunchu Feng, Wai Tak Lau, Kaveri A. Thakoor
published similarity 0.52
Abstract · 18 pages. Accepted as a poster at the GenAI for Health Workshop at NeurIPS 2026 (non-archival)

Self-supervised learning aims to learn meaningful representations from unlabeled data, potentially allowing models to capture subtle anatomical variations across patients and reduce the amount of labeled data needed. Image-based Joint-Embedding Predictive Architecture (I-JEPA) learns by predicting target-region representations from visible context rather than reconstructing pixels. However, its uniform target placement does not account for the anatomical structure of retinal OCT, where retinal tissue occupies only part of each B-scan. We investigate anatomy-guided target selection using image intensity and predicted retinal segmentation while retaining the I-JEPA architecture and latent prediction objective. We compare anatomy-guided rectangular targets, anatomy-shaped targets and coverage-constrained placement with uniform masking, and evaluate the learned representations using linear probing for glaucoma classification on FairVision. We found that rectangular targets guided by image intensity achieved the highest linear-probe AUC in our comparisons. We show that anatomically meaningful target selection is promising for retinal OCT representation learning, while greater anatomical specificity did not consistently improve performance.

0.35

Optic Disc Segmentation in Fundus Images: From Classical Image Processing and Deformable Models to Modern AI

eess.IV cs.CV ·2026-08-18 ·Buket D. Barkana
similarity 0.51
Abstract

Accurate localization and segmentation of the optic disc (OD) are important for retinal image analysis and glaucoma assessment, yet remain challenging due to variations in illumination, pathology, vascular interference, and poorly defined boundaries. This structured methodological review examines the evolution of OD segmentation from classical image-processing and deformable models to contemporary artificial intelligence (AI)-based approaches. A structured literature search and study-selection process was used to identify representative studies spanning major methodological developments. The review first summarizes commonly used fundus-image datasets, then organizes classical methods by principal mechanisms, including intensity and thresholding, histogram and entropy analysis, morphology, geometric and Hough-transform methods, filtering and feature operators, texture- and region-based approaches, and active-contour and level-set models. This paper pays particular attention to the assumptions, strengths, limitations, and complementary roles of these methods in OD localization and boundary delineation. Representative AI approaches are subsequently examined to illustrate the transition from handcrafted features and explicitly defined priors to learned representations, Transformer-based segmentation, boundary- and shape-aware learning, promptable segmentation, and retinal foundation models. Across these methodological generations, several core segmentation principles persist, including region-of-interest localization, multiscale representation, geometric and anatomical constraints, and boundary regularization, although their implementation has shifted from predefined operators to learned modules, losses, prompts, and pretrained representations. The review further identifies boundary ambiguity, anatomical variability, domain shift, and cross-dataset generalization as continuing challenges.

0.27

Evaluation of Clinically Steerable Retinal Image Generation from Foundation Model Latent Spaces

cs.CV ·2026-08-13 ·Zuzanna A. Wakefield-Skórniewska, Bartłomiej W. Papież
published similarity 0.51
Abstract · MICCAI 2026 Workshop SASHIMI Submission

Medical foundation models learn latent representations of clinically meaningful phenotypes, yet their ability to support controllable image generation remains largely unexplored. We evaluate four retinal foundation models within the representation tokenizer framework and examine whether demographic and clinical information encoded in latent representations from foundation models is preserved during synthetic image generation. We show that generated representations and images faithfully inherit phenotype information when evaluated within their originating foundation models, consistently outperforming conventional latent diffusion on multiple downstream prediction tasks. However, these gains largely disappear when evaluated using classifiers trained on real images, revealing a previously uncharacterised synthetic-to-real representation gap. These findings demonstrate that foundation-model latent spaces provide a powerful substrate for controllable retinal synthesis while highlighting the need to better align synthetic representations with real-image distributions.

0.17