A Benchmark Graph Dataset for Transient Stability Assessment of the IEEE 9-Bus System: 20,000 Scenarios with Full Generator Trajectories

Hussein Suprême, Martin de Montigny, Arnaud Zinflou

eess.SY ·submitted 2026-08-18 21:06 UTC · v1
publishedbenchmark

Abstract

Transient stability assessment determines whether a power system retains synchronism after a large disturbance. Machine-learning surrogates can accelerate it, but progress is limited by the lack of open datasets that combine dynamic ground truth, network graph structure, and machine parameters. We release a benchmark of 20,000 three-phase-to-ground fault scenarios on the IEEE 9-bus system. Each scenario couples an AC power-flow operating point with a detailed electromagnetic-transient simulation of the post-fault response. Every record provides the network as an attributed graph (nine buses, eighteen directed branches, ten node and twelve edge features), the full rotor-angle and speed trajectories of the three generators, the static machine constants, the fault description, and a center-of-inertia binary stability label. Wide load and generation scalings across eighteen fault locations yield a near-balanced distribution (48.96\% stable, 51.04\% unstable). Generation is deterministic and fully reproducible through fixed seeds and public code. The dataset is distributed on IEEE DataPort under a persistent DOI and supports stability classification, trajectory prediction, margin and critical-clearing-time estimation, and the comparison of topology-aware, physics-based, and hybrid learning methods.

Comment
Descriptor Open dataset IEEE9
DOI
10.21227/d10j-5b27

Closest papers

Nearest neighbours by meaning across the whole index.

A simulation based dataset of faults and events for machine learning in power systems

eess.SY ·2026-08-20 ·Georg Kordowich, Jonathan Loebel, Julian Oelhaf, Andreas Maier, Siming Bayer +2 more
similarity 0.65
Abstract

The integration of inverter-based renewable energy sources into electric grids challenges conventional power system protection. Machine learning-based solutions can address these challenges by utilizing available data in modern smart grids. However, the lack of open datasets prevents reproducibility and fair comparisons between different approaches and their results, which hinders further progress. Therefore, this paper presents EvEMTBench, a synthetic dataset of faults and events generated using electromagnetic transient simulations. The physical plausibility of the power system simulation is ensured by validating the simulation parameters against established literature and providing comprehensive documentation of the simulation procedure. The dataset is designed for training, fine-tuning, and benchmarking machine learning models by providing synchronized point-on-wave voltage and current measurements at 9600 Hz across a diverse set of topologies and voltage levels. The inclusion of a wide range of fault and operating events allows the utilization of EvEMTBench for different tasks like incipient fault detection, fault localization, or event detection.

0.50

GCN-Based Model for Fault Classification in Distribution Networks under Harmonic Distortion

eess.SP ·2026-09-23 ·Fathima Razeeya Mohamed Razick, Syed Muhammad Ahsan, Petr Musilek
published similarity 0.63
Abstract · Accepted and presented at the IEEE Power and Energy Society General Meeting 2026, Montreal, Canada, July 19-23, 2026

The increasing integration of distributed energy resources introduces new challenges for accurate fault detection and classification in distribution networks. This paper presents a topology-aware graph convolutional network-based model for fault classification under inverter-induced harmonic distortion. The model uses pre-fault and post-fault voltage and current phasors, including harmonic components, mapped to the IEEE 34-bus system topology. The simulation data generated in OpenDSS encompass varying levels of penetration of solar photovoltaics (30%, 50%, 70%) and current total harmonic distortion (0%, 1%, 3%, 5%) across multiple fault types: single line-to-ground, line-to-line, double line-to-ground, and three-phase-to-ground. A differential evolution algorithm is employed to optimize the hyperparameters of the network, resulting in a three-layer model that achieves an F1-score of 0.98. Stress testing across scenarios confirms high robustness and minimal class confusion. The results demonstrate that a graph convolutional network-based model can effectively classify distribution faults under varying photovoltaic penetration levels and harmonically distorted conditions. Comparative analyses with convolutional neural network, long short-term memory, and multi-layer perceptron architectures demonstrate that the proposed model delivers superior classification performance, particularly under the most stressed condition with 70% photovoltaic penetration and 5% harmonic distortion.

0.48

Droop-Aware Foundation Model Power Flow

cs.ET ·2026-09-20 ·Khezr Sanjani, Peng Zhang
similarity 0.62
Abstract

This paper develops a droop-aware extension of the GridFM power systems foundation model, embedding droop gains and frequency/voltage deadband parameters as per-bus node features to enable control-aware AC power-flow analysis. Existing power-flow datasets encode only static electrical features, conflating operating points from qualitatively different control regimes; this work resolves that gap by exposing droop and deadband parameters as structured node features, with deadband discontinuities handled through a smooth tanh approximation that preserves solver differentiability. A transformer-based graph neural network is pre-trained on masked reconstruction and fine-tuned on the resulting control-aware datasets. The framework is validated against PSCAD electromagnetic-transient simulations on a two-bus system (0.11% maximum steady-state error) and cross-validated against an independent PyPower droop solver on the IEEE 24-bus RTS. On the 24-bus system the surrogate attains R2 = 0.9996 for active generation and 0.0015 p.u. voltage-magnitude RMSE; scalability is confirmed on the IEEE 300-bus system (0.0036 p.u. RMSE, R2 = 0.9841 for voltage magnitude across 299,700 predictions). A three-mode control study further shows that the deadband widens the control-error distribution while leaving total droop compensation unchanged, establishing deadband width as an actionable node-level design feature.

0.29

Detecting False Data Injection and Unstable Operation in Smart Grid via System-Aware Graph Boundary Learning

cs.CR ·2026-09-28 ·Emad Efatinasab, Denis Donadel, Mirco Rampazzo, Chuadhry Mujeeb Ahmed
similarity 0.62
Abstract

Cyber-physical power systems increasingly rely on data-driven tools to detect instability and support reliable grid operation. However, reliable stability prediction is difficult when unstable operating configurations are rare, sensitive, or unavailable during model development, since collecting such data safely and at scale is often impractical. At the same time, False Data Injection (FDI) attacks can manipulate reported system parameters to trigger false instability alarms or conceal unsafe operation, and such threats in Decentral Smart Grid Control (DSGC) systems remain largely unexplored. These challenges are rarely addressed jointly, leaving a gap between stability prediction and attack detection that this work aims to close. In this paper, we introduce StarGNN, a graph learning framework that learns the stable operating region exclusively from clean stable configurations and uses a single abnormality score to flag reported configurations that should not be trusted as evidence of safe operation, covering both genuine instability and unseen FDI manipulations. Each configuration is represented as a producer-consumer star graph and processed by a role aware graph neural network, with physics constrained pseudo-negatives generated by perturbing reaction time and price response parameters standing in for the unavailable unstable and attack data. A single threshold, calibrated only on held-out stable data, is used without task or attack specific adjustment. Evaluated on nine unseen FDI scenarios, StarGNN detects between 0.780 and 0.973 of attacks on stable configurations and retains a post attack instability recall between 0.972 and 0.999 on unstable ones, with 0.899 recall against a stronger adaptive attacker, showing that stable-only boundary learning can support both stability prediction and attack detection without access to genuine unstable labels or attack samples during training.

0.13

Mycelium: A Generalizable Cross-Grid Multi-Task Model for Electrical Distribution Systems

cs.LG ·2026-09-27 ·Zhengyang Wei, Shourya Bose, Helgi Hilmarsson, Elena Carnio, Dhruv Suri
benchmark similarity 0.61
Abstract

Electrical distribution grid operations require inference across heterogeneous networks from sparse, noisy, and incomplete time series measurements. In this work, we identify challenges and explore solutions towards a unified model that can perform diverse tasks grounded in the physics of the electric grid and generalize to unseen distribution networks. We define a unified grid ontology that represents variable sized distribution networks as heterogeneous graphs while preserving native topology, asset types, and electrical relationships across networks. We develop a physics based data simulation pipeline that combines reference and procedurally generated distribution networks with network reconfigurations, fault scenarios, and configurable sensing conditions. We present Mycelium, a heterogeneous graph transformer with structure aware communication edges and electrical reference features that encode network position and nominal phase orientation, together with task specific temporal readouts which generate per task outputs. We train Mycelium on reference as well as synthetic grids, and study its generalization on benchmark networks completely excluded from training and validation. Mycelium is observed to outperform task specific neural baselines on most reported benchmark metrics. Architectural ablations and the aforementioned studies reveal Mycelium's capability to learn representations of the underlying physics which serves to enhance cross-task performance, thereby addressing a significant challenge in unified grid models.

0.26

When Gigawatts of Computational Load Disappear: Cycle-Space Certificates for Grid Synchronization and Transient Stability

eess.SY math.DSphysics.soc-ph ·2026-09-23 ·Michael Chertkov
similarity 0.61
Abstract · 13 pages, 2 figures

Rapid growth of data centers and artificial-intelligence services is producing computational loads at scales once associated mainly with largest power plants. Recent grid events show that a routine transmission disturbance can cause several gigawatts of data-center demand to disconnect or transfer to backup nearly at once. This article revisits the classical synchronization and transient-stability theory needed to reason about such events. We organize four lines of work---graph-based synchronization conditions, winding-number descriptions of nonlinear power flow, separable convex network optimization, and direct energy methods---into a single cycle-space certificate framework for the lossless fixed-voltage model. The static layer gives an exact strict-cohesion test within a prescribed winding cell and reveals the widely used Dörfler--Chertkov--Bullo test as a quadratic surrogate of the same convex problem. The dynamic layer converts the critical-energy calculation into a finite family of convex boundary problems. Standard MATPOWER benchmarks illustrate both what the stronger static test gains and where it gains nothing: the 118-bus case admits $16.2\%$ more loading than the sufficient screen, while the 39-bus case is bridge-limited and the thresholds coincide. A stylized $2.7$-GW 39-bus event further shows that transient margin can change by about a factor of two depending on where balancing power is supplied, even when every final balanced operating point remains statically feasible. The result is a tutorial synthesis and an extensible deterministic certificate for emerging gigawatt-scale computational-load contingencies.

0.53

Flexible Training Workloads in Large-Scale AI Data Centers for Transient-Stability Support in Transmission-Constrained Power Systems

eess.SY ·2026-08-31 ·Jae-Kyeong Kim
similarity 0.60
Abstract · 11 pages, 7 figures, 1 table

The rapid expansion of large-scale artificial intelligence (AI) data centers is adding substantial, concentrated, and rapidly varying loads to transmission-constrained power systems. Although such load variations are generally regarded as operational challenges, this paper presents an alternative perspective in which the upward load flexibility of AI data centers could be coordinated for transient-stability support. To this end, this paper proposes training-induced load surge (TILS), a fast demand-side strategy that initiates or resumes flexible AI training workloads after fault clearing to increase active-power demand at electrically effective locations. The resulting load increase allows accelerating generators to supply additional electrical power, thereby reducing the accelerating-power imbalance and limiting the first-swing rotor-angle excursion. The underlying mechanism is first clarified in a single-machine infinite-bus (SMIB) system and then evaluated in the IEEE 39-bus system and a large-scale Korean power system. Results across all three systems demonstrate that TILS can increase the transient-stability-constrained generation limit. Larger responses, earlier activation, and siting at buses with a stronger electrical influence on the critical generators provide greater generation-limit increases. These results suggest that the upward load-response capability of AI data centers can provide complementary transient-stability support when sufficient electrical headroom, flexible workloads, and reliable grid-triggered activation are available.

0.29

Scalable Voltage-Stability Dataset Generation Via Boundary-Proximity Indicators Clustering

eess.SY ·2026-08-28 ·Rock Agon, Robin Preece, Jovica V. Milanović
similarity 0.60
Abstract · Submitted to MedPower Conference 2026

This paper proposes a scalable framework for voltage-stability dataset generation. Voltage-stability-constrained planning increasingly relies on machine-learning surrogates but training them requires large datasets labelled by continuation power flow (CPF) results, which is computationally costly. To address this, this paper proposes a framework that uses hierarchical clustering on boundary-proximity indicators to reduce the number of required CPF evaluations. The proposed approach combines (i) uniform sampling of feasible operating space using Hit-and-Run Markov Chain Monte Carlo, (ii) structured stress directions via maximin Latin hypercube sampling (LHS), (iii) sensitivity-guided perturbations to target weak buses, and (iv) clustering-based representative CPF labelling that reconstructs the voltage stability margins of unlabelled operating points from representative cluster medoids. Results on the IEEE 39-bus system show that the proposed framework significantly reduces CPF evaluations by 95.45% while preserving high accuracy and boundary fidelity for both regression and classification tasks. The reduced surrogates remain structurally consistent with their full-CPF dataset counterparts, demonstrating the suitability and scalability of the proposed approach for operation and planning optimization.

0.25