CS Paper Radar

Scalable Voltage-Stability Dataset Generation Via Boundary-Proximity Indicators Clustering

Rock Agon, Robin Preece, Jovica V. Milanović

eess.SY ·submitted 2026-08-28 13:02 UTC · v1

Abstract

This paper proposes a scalable framework for voltage-stability dataset generation. Voltage-stability-constrained planning increasingly relies on machine-learning surrogates but training them requires large datasets labelled by continuation power flow (CPF) results, which is computationally costly. To address this, this paper proposes a framework that uses hierarchical clustering on boundary-proximity indicators to reduce the number of required CPF evaluations. The proposed approach combines (i) uniform sampling of feasible operating space using Hit-and-Run Markov Chain Monte Carlo, (ii) structured stress directions via maximin Latin hypercube sampling (LHS), (iii) sensitivity-guided perturbations to target weak buses, and (iv) clustering-based representative CPF labelling that reconstructs the voltage stability margins of unlabelled operating points from representative cluster medoids. Results on the IEEE 39-bus system show that the proposed framework significantly reduces CPF evaluations by 95.45% while preserving high accuracy and boundary fidelity for both regression and classification tasks. The reduced surrogates remain structurally consistent with their full-CPF dataset counterparts, demonstrating the suitability and scalability of the proposed approach for operation and planning optimization.

Comment
Submitted to MedPower Conference 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Hierarchical Agglomerative Clustering for Efficient Annual Voltage Security Assessment in Very-High RES Penetrated Power Systems

eess.SY ·2026-08-28 ·Rock Agon, Robin Preece, Jovica V. Milanovic
similarity 0.70
Abstract · In preparation for submission to IEEE

Voltage security assessment in power systems with high renewable energy source (RES) penetration requires analyzing many operating conditions to capture variability and uncertainty, but simulating a full year of operating points is computationally costly - motivating the selection of representative operating points (ROPs). Most existing methods cluster demand and generation profiles, but similarity in these profiles does not guarantee similarity in voltage behavior, since reactive power limits, voltage-control actions, and nonlinear network interactions shape voltage response in ways that cannot be inferred from power profile patterns. This paper proposes an unsupervised learning framework that selects ROPs based on the system's actual voltage response: each operating point is represented by system-wide voltage-risk indices from AC power-flow solutions, Principal Component Analysis reduces dimensionality, and Hierarchical Agglomerative Clustering with Ward linkage identifies representative voltage regimes. A comprehensive set of evaluation criteria then measures how well the selected ROPs reproduce the full year's voltage-security characteristics under normal and contingency conditions. On the IEEE Voltage Test System under very high RES penetration, the framework reduces the annual operating point set by 99.66 percent while reproducing full-year voltage behavior with 98.3 percent reconstruction accuracy in steady state and 93.4 percent in post-contingency response, outperforming existing injection-space clustering and heuristic sampling.

0.30

A Benchmark Graph Dataset for Transient Stability Assessment of the IEEE 9-Bus System: 20,000 Scenarios with Full Generator Trajectories

eess.SY ·2026-08-18 ·Hussein Suprême, Martin de Montigny, Arnaud Zinflou
publishedbenchmark similarity 0.60
Abstract · Descriptor Open dataset IEEE9

Transient stability assessment determines whether a power system retains synchronism after a large disturbance. Machine-learning surrogates can accelerate it, but progress is limited by the lack of open datasets that combine dynamic ground truth, network graph structure, and machine parameters. We release a benchmark of 20,000 three-phase-to-ground fault scenarios on the IEEE 9-bus system. Each scenario couples an AC power-flow operating point with a detailed electromagnetic-transient simulation of the post-fault response. Every record provides the network as an attributed graph (nine buses, eighteen directed branches, ten node and twelve edge features), the full rotor-angle and speed trajectories of the three generators, the static machine constants, the fault description, and a center-of-inertia binary stability label. Wide load and generation scalings across eighteen fault locations yield a near-balanced distribution (48.96\% stable, 51.04\% unstable). Generation is deterministic and fully reproducible through fixed seeds and public code. The dataset is distributed on IEEE DataPort under a persistent DOI and supports stability classification, trajectory prediction, margin and critical-clearing-time estimation, and the comparison of topology-aware, physics-based, and hybrid learning methods.

0.43

Expediting AC Contingency Analysis using a Basecase Machine Learning Model

eess.SY ·2026-09-29 ·Md Obaidur Rahman, Vassilis Kekatos
similarity 0.59
Abstract · 10 page, 7 figures

Grid planning and operation under increasingly variable operating conditions require fast and accurate AC power flow (AC-PF) contingency analysis for numerous line outages. While ML models can accelerate these computations, existing approaches often require either training separate models for different contingencies or a single model using data from multiple topologies. Both approaches incur substantial offline data generation and training costs. To address this gap, this work proposes a fixed-point framework that reuses a single ML model trained exclusively on basecase topology data to predict post-contingency AC-PF states under any non-critical single-line outage. We analyze the proposed method's convergence under the DC model approximation and derive its convergence rate in terms of network parameters. As a side result, we show that power transfer distribution factors (PTDFs) for non-critical lines have magnitudes less than one. We further characterize the ML training region to accommodate PF specifications encountered during fixed-point iterations and derive bounds on ML prediction errors for post-contingency state estimates. Numerical tests on a 6,717-bus synthetic Texas system demonstrate convergence across all non-critical single-line outages, with prediction errors remaining close to those of basecase. The proposed framework offers a favorable tradeoff between the speed of DC solvers and Newton-Raphson accuracy.

0.11

Learning by Examples: Power Grid Steady State Analysis with a Tabular Foundation Model

cs.LG ·2026-10-14 ·Olayiwola Arowolo, Oluwadara Adedeji, Peter Palensky, Jochen L. Cremer
similarity 0.58
Abstract · 12 pages, 8 figures, under review

Foundation models have shown strong generalization across scientific domains, but their use in power systems remains largely task-specific. We investigate whether a pretrained tabular foundation model (TFM), TabPFN, can serve as a general-purpose neural solver for power grid steady-state analysis. We evaluate the TFM on three tasks: power flow (PF) prediction, N-k contingency screening (NCS), and voltage stability margin (VSM) prediction. We performed experiments on 118- and 2000-bus systems, comparing the TFM against task-specific neural baselines. Without retraining or fine-tuning, the TFM matches or outperforms the best task-specific model in several settings across the three tasks. For 118-bus PF prediction, a variant of the TFM achieves errors of $1\times 10^{-3}$ pu for voltage magnitudes and $0.30^\circ$ for voltage angles, outperforming all baselines. On unseen N-1 contingency and close-to-infeasible PF cases, the TFM is competitive with the DCPF approximation. For millions of unseen N-2 contingencies, the TFM achieves AUCs of 0.92 and 0.95 for branch and voltage violation screening, respectively. The TFM also attains accurate VSM prediction performance for the 2000-bus system with limited labelled data. The TFM attains strong results across the tested tasks despite pretraining without any power-system-specific dataset and requiring no fine-tuning step. These results offer a glimpse into the potential of pretrained TFMs as a neural solver for a range of power grid analysis tasks.

0.15

PowerModels-ACOPF-AI: On-the-Fly Machine Learning Approach for Solving AC Optimal Power Flow Integrating Renewable Energy Sources

eess.SY ·2026-09-16 ·Bhuban Dhamala, Jose Tabarez, Anup Pandey
benchmark similarity 0.58
Abstract

The increasing complexity of modern power systems, driven by high renewable penetration, load variability, and operational uncertainty, demands fast and reliable solutions to the AC optimal power flow problem (AC-OPF). Traditional optimization methods, though accurate, often struggle with scalability and high computational burdens, making them impractical for real-time use in large networks. This paper introduces PowerModels-ACOPF-AI, a two-stage Bayesian Neural Network (BNN) surrogate designed to predict generator set points, bus voltages, and phase angles with uncertainty. The framework integrates a performance-sensitive on-the-fly learning mechanism that identifies regions of degraded prediction accuracy and dynamically retrains with additional AC-OPF solutions generated by PowerModels.jl. This self-adaptive loop ensures robust performance, enabling the model to maintain accuracy under novel or highly variable operating conditions. Validation on benchmark test systems of different sizes, namely the 30-bus, 200-bus, and 500-bus networks, demonstrates strong generalization capability, efficient handling of stochastic renewable injections, and the ability to provide rapid, uncertainty-aware predictions. Beyond predictive accuracy, the proposed approach offers practical value as both a real-time advisory tool for system operators and a fast initializer for conventional solvers, thus supporting resilient and efficient grid operation in future power systems.

0.16

EvEMTBench: An Open Benchmark for Machine Learning in Power System Protection

eess.SY cs.LG ·2026-09-23 ·Julian Oelhaf, Georg Kordowich, Christian Bergler, Andreas Maier, Johann Jäger +1 more
benchmarkcode/data similarity 0.57
Abstract · 15 pages, 3 figures. Supplementary information included. Code: https://github.com/EvEMTBench/evemtbench-benchmark

Studies of machine-learning-based power system protection are difficult to compare because task definitions, measurement access, data partitions, metrics, and generalization conditions often differ. EvEMTBench addresses this gap with an open, executable, and versioned benchmark that fixes these evaluation choices while leaving model design open. Across four grids spanning 20-345 kV, it defines 12 protection and event-analysis functions instantiated as 24 scored tasks and supports structured evaluation across observability conditions, predefined distribution shifts, and zero-shot and fine-tuned cross-grid transfer. Committed partitions, leakage controls, and reproducible reporting provide a common basis for comparing future methods. A reference evaluation spanning trivial, conventional, feature-based, and deep-learning baselines shows that wider observability is not uniformly beneficial, shifted conditions can reveal failures not apparent in-distribution, and cross-grid transfer is substantially stronger for fault detection than for fault localization. Protection-relevant diagnostics identify failure modes not apparent from primary metrics alone. EvEMTBench therefore makes generalization in machine-learning-based protection an explicit and reproducible evaluation problem.

0.22

AC-Aware Steady-State Security Region Characterization via Exclusion Refinement

eess.SY ·2026-10-12 ·Zhirou Wang, Zhengshuo Li, Shuo Yang
similarity 0.57
Abstract

As active power dispatch becomes increasingly coupled with reactive power support and voltage security in modern power systems, AC security regions (AC-SRs) under exact steady-state AC power flow (AC-PF) constraints provide valuable insights into admissible operating boundaries and security margins for security assessment. However, the nonconvexity of exact AC-PF constraints makes it difficult to achieve both accuracy and computational efficiency in AC-SR characterization. To this end, this paper proposes an AC-aware iterative exclusion refinement (AC-ITER) approach that refines a given convex-relaxed AC-SR toward the exact AC-SR by progressively constructing and removing convexlocal exclusion subregions around numerically identified insecure points. Boundary-point searches and dual-based local exclusion cuts provide a tractable approximation of relaxation-induced insecure portions. A statistical certification method based on uniform sampling is developed to support high-confidence assessment of residual-region security and guide termination, while an AC-PF security similarity-based acceleration (AC-SSA) approach is introduced to further accelerate the sampling-based search for insecure operating points. Numerical studies on academic test systems and real-world systems demonstrate the characterization accuracy of AC-ITER and the computational efficiency gained through AC-SSA.

0.27

Physics-Informed but Not Physics-Consistent: Error Geometry and Subspace Projection for Neural AC Power Flow

cs.LG cs.AI ·2026-10-05 ·Changhun Kim, Timon Conrad, Redwanul Karim, Karan Pahlajani, Julian Oelhaf +5 more
code/data similarity 0.57
Abstract · ICASSP 2027 submitted; 3 figures, 3 tables. Code: https://github.com/Kimchangheon/neural-acpf-error-geometry

Recent neural power-flow solvers, including emerging foundation models, achieve accurate voltage predictions, yet such accuracy does not necessarily imply physically consistent solutions. Even small complex voltage errors can yield large AC power-balance residuals. We study this accuracy-consistency gap across PIGNN-GC, GridSFM, gridfm-graphkit, and LUMINA on realistic 2224-bus Great Britain network (GBnetwork) scenarios, with cross-grid evaluation of GridSFM over 31 systems. Using a singular value decomposition (SVD) basis fitted to training AC power-flow solutions, we find that neural prediction errors contain substantial components outside the dominant solution subspace. To address this mismatch, calibrated solution-subspace projection (CSP) suppresses off-subspace prediction components after train-only bias calibration, reducing Mean PB by 67.0%, 37.8%, 40.5%, and 68.9% for PIGNN-GC, GridSFM, gridfm-graphkit, and LUMINA, respectively, relative to calibrated predictions, while improving voltage-magnitude accuracy in all four models. These results identify output-error geometry as an important factor in physics-consistent neural AC power flow. Code: https://github.com/Kimchangheon/neural-acpf-error-geometry

0.34