CS Paper Radar

Hierarchical Agglomerative Clustering for Efficient Annual Voltage Security Assessment in Very-High RES Penetrated Power Systems

Rock Agon, Robin Preece, Jovica V. Milanovic

eess.SY ·submitted 2026-08-28 12:59 UTC · v1

Abstract

Voltage security assessment in power systems with high renewable energy source (RES) penetration requires analyzing many operating conditions to capture variability and uncertainty, but simulating a full year of operating points is computationally costly - motivating the selection of representative operating points (ROPs). Most existing methods cluster demand and generation profiles, but similarity in these profiles does not guarantee similarity in voltage behavior, since reactive power limits, voltage-control actions, and nonlinear network interactions shape voltage response in ways that cannot be inferred from power profile patterns. This paper proposes an unsupervised learning framework that selects ROPs based on the system's actual voltage response: each operating point is represented by system-wide voltage-risk indices from AC power-flow solutions, Principal Component Analysis reduces dimensionality, and Hierarchical Agglomerative Clustering with Ward linkage identifies representative voltage regimes. A comprehensive set of evaluation criteria then measures how well the selected ROPs reproduce the full year's voltage-security characteristics under normal and contingency conditions. On the IEEE Voltage Test System under very high RES penetration, the framework reduces the annual operating point set by 99.66 percent while reproducing full-year voltage behavior with 98.3 percent reconstruction accuracy in steady state and 93.4 percent in post-contingency response, outperforming existing injection-space clustering and heuristic sampling.

Comment
In preparation for submission to IEEE

Closest papers

Nearest neighbours by meaning across the whole index.

Scalable Voltage-Stability Dataset Generation Via Boundary-Proximity Indicators Clustering

eess.SY ·2026-08-28 ·Rock Agon, Robin Preece, Jovica V. Milanović
similarity 0.70
Abstract · Submitted to MedPower Conference 2026

This paper proposes a scalable framework for voltage-stability dataset generation. Voltage-stability-constrained planning increasingly relies on machine-learning surrogates but training them requires large datasets labelled by continuation power flow (CPF) results, which is computationally costly. To address this, this paper proposes a framework that uses hierarchical clustering on boundary-proximity indicators to reduce the number of required CPF evaluations. The proposed approach combines (i) uniform sampling of feasible operating space using Hit-and-Run Markov Chain Monte Carlo, (ii) structured stress directions via maximin Latin hypercube sampling (LHS), (iii) sensitivity-guided perturbations to target weak buses, and (iv) clustering-based representative CPF labelling that reconstructs the voltage stability margins of unlabelled operating points from representative cluster medoids. Results on the IEEE 39-bus system show that the proposed framework significantly reduces CPF evaluations by 95.45% while preserving high accuracy and boundary fidelity for both regression and classification tasks. The reduced surrogates remain structurally consistent with their full-CPF dataset counterparts, demonstrating the suitability and scalability of the proposed approach for operation and planning optimization.

0.25

AC-Aware Steady-State Security Region Characterization via Exclusion Refinement

eess.SY ·2026-10-12 ·Zhirou Wang, Zhengshuo Li, Shuo Yang
similarity 0.59
Abstract

As active power dispatch becomes increasingly coupled with reactive power support and voltage security in modern power systems, AC security regions (AC-SRs) under exact steady-state AC power flow (AC-PF) constraints provide valuable insights into admissible operating boundaries and security margins for security assessment. However, the nonconvexity of exact AC-PF constraints makes it difficult to achieve both accuracy and computational efficiency in AC-SR characterization. To this end, this paper proposes an AC-aware iterative exclusion refinement (AC-ITER) approach that refines a given convex-relaxed AC-SR toward the exact AC-SR by progressively constructing and removing convexlocal exclusion subregions around numerically identified insecure points. Boundary-point searches and dual-based local exclusion cuts provide a tractable approximation of relaxation-induced insecure portions. A statistical certification method based on uniform sampling is developed to support high-confidence assessment of residual-region security and guide termination, while an AC-PF security similarity-based acceleration (AC-SSA) approach is introduced to further accelerate the sampling-based search for insecure operating points. Numerical studies on academic test systems and real-world systems demonstrate the characterization accuracy of AC-ITER and the computational efficiency gained through AC-SSA.

0.27

Data-Optimized Contingency Screening: A Machine Learning Approach to Power System Security

cs.AI cs.LG ·2026-09-03 ·Joshua Salako, Folajimi Osikomaiya, Olakorede Olamiju
published similarity 0.58
Abstract · Accepted for presentation at the 3rd EIE International Conference on Computing, Networking, Robotics and Telecommunication (EIECon), 2025. T…

Ensuring the security of the power system is essential for stability and reliability, especially in the event of disruption. Effective classification of contingency in power systems enables proactive decision-making and mitigates large-scale breakdowns and failures. This study explores the use of machine learning algorithms to classify security levels of contingencies in power systems into safe, moderate or severe classes. For this approach, Newton-Raphson load flow method extracts system data from contingency scenarios, using Overall Performance Index (OPI) as safety measure. For data pre-processing, Synthetic Minority Over-Sampling Technique (SMOTE) and Principal Component Analysis (PCA) is used to address class imbalance and reduce dimensionality, respectively. K-Nearest Neighbours (KNN), Random Forest (RF) and Support Vector Machines (SVM) is trained and evaluated on datasets generated through N-k contingency scenarios for k equal 1, 2, and 3 on IEEE-14 and IEEE-30 bus systems using four hybrid pre-processing configurations: normalized, SMOTE-balanced, PCA-transformed, and a combined SMOTE PCA-transformed. Performance is assessed by precision, recall and F1 score, with priority given to the severe contingency classes. The RF achieved the highest F1 scores of 0.97 in IEEE-30 and 0.86 in IEEE-14, SVM benefits significantly from PCA and improves the accuracy of the classification, while KNN is best suited for SMOTE and PCA conversion. The findings show that PCA contributes more than SMOTE to the overall performance of the model. However, SMOTE improves recall but can introduce false positives and is therefore a compromise of accuracy. This study highlights machine learning as a scalable and powerful alternative to traditional contingency analysis, which improves the assessment of security in real time.

0.25

A simulation based dataset of faults and events for machine learning in power systems

eess.SY ·2026-08-20 ·Georg Kordowich, Jonathan Loebel, Julian Oelhaf, Andreas Maier, Siming Bayer +2 more
similarity 0.58
Abstract

The integration of inverter-based renewable energy sources into electric grids challenges conventional power system protection. Machine learning-based solutions can address these challenges by utilizing available data in modern smart grids. However, the lack of open datasets prevents reproducibility and fair comparisons between different approaches and their results, which hinders further progress. Therefore, this paper presents EvEMTBench, a synthetic dataset of faults and events generated using electromagnetic transient simulations. The physical plausibility of the power system simulation is ensured by validating the simulation parameters against established literature and providing comprehensive documentation of the simulation procedure. The dataset is designed for training, fine-tuning, and benchmarking machine learning models by providing synchronized point-on-wave voltage and current measurements at 9600 Hz across a diverse set of topologies and voltage levels. The inclusion of a wide range of fault and operating events allows the utilization of EvEMTBench for different tasks like incipient fault detection, fault localization, or event detection.

0.50

EvEMTBench: An Open Benchmark for Machine Learning in Power System Protection

eess.SY cs.LG ·2026-09-23 ·Julian Oelhaf, Georg Kordowich, Christian Bergler, Andreas Maier, Johann Jäger +1 more
benchmarkcode/data similarity 0.56
Abstract · 15 pages, 3 figures. Supplementary information included. Code: https://github.com/EvEMTBench/evemtbench-benchmark

Studies of machine-learning-based power system protection are difficult to compare because task definitions, measurement access, data partitions, metrics, and generalization conditions often differ. EvEMTBench addresses this gap with an open, executable, and versioned benchmark that fixes these evaluation choices while leaving model design open. Across four grids spanning 20-345 kV, it defines 12 protection and event-analysis functions instantiated as 24 scored tasks and supports structured evaluation across observability conditions, predefined distribution shifts, and zero-shot and fine-tuned cross-grid transfer. Committed partitions, leakage controls, and reproducible reporting provide a common basis for comparing future methods. A reference evaluation spanning trivial, conventional, feature-based, and deep-learning baselines shows that wider observability is not uniformly beneficial, shifted conditions can reveal failures not apparent in-distribution, and cross-grid transfer is substantially stronger for fault detection than for fault localization. Protection-relevant diagnostics identify failure modes not apparent from primary metrics alone. EvEMTBench therefore makes generalization in machine-learning-based protection an explicit and reproducible evaluation problem.

0.22

Severity-Aware Minimum Security Sets for Accelerated Preventive SCOPF Using Machine Learning

eess.SY ·2026-10-14 ·Mohammad Iman Alizadeh, Saeed Zeynali, Salah Ghamizi, Sylvain Kubler
similarity 0.56
Abstract

This paper proposes a severity-aware machine learning framework for reducing the computational burden of preventive AC security-constrained optimal power flow (PSCOPF). The central idea is to identify a compact minimum security set (MSS) containing only the non-dominated contingencies and associated post-contingency constraints that materially influence the preventive operating point while satisfying a prescribed severity tolerance. An offline procedure combines AC security assessment, severity-based ranking, non-dominated screening, and iterative reduced PSCOPF. After each reduced PSCOPF solution, exhaustive security assessment over all credible contingencies identifies additional contingency--constraint pairs whose residual severity exceeds the specified threshold. Severity is characterized using the normalized number, accumulated magnitude, maximum magnitude, and average magnitude of post-contingency violations. The resulting operating-point-dependent MSSs are used as labels for a supervised multi-label learning model that predicts the security elements required to construct the reduced PSCOPF directly from the pre-contingency state. The proposed framework therefore focuses the optimization on the contingencies and constraints that affect preventive control decisions, reducing problem size and computation time while explicitly controlling residual post-contingency severity. Results on the IEEE 60-bus and 118-bus systems, the latter having an approximately seven-times-larger PSCOPF formulation, demonstrate substantial computational reductions with limited impact on the preventive operating solution.

0.22

PhyPro-FM: A Physics and Prompt-Guided Graph Foundation Model for Contingency Analysis

eess.SY cs.AIcs.LG ·2026-10-19 ·Xu Yang, Zhanyuan Sheng, Chenhui Lin, Haotian Liu, Qi Wang +2 more
similarity 0.56
Abstract

The continuous evolution of next-generation power systems, characterized by the high penetration of renewable energy resources and dynamic topology variations, poses formidable challenges to traditional N-1/N-2 contingency analysis in terms of computational efficiency and scalability. While deep learning-based methods offer accelerated inference, existing studies predominantly treat contingency analysis as a pure regression problem, often overlooking the physical essence of grid operation and engineering requirements of real-world scenarios. To bridge this gap, this paper proposes a physics and prompt-guided graph foundation model (PhyPro-FM) for generalizable and engineering-viable contingency analysis. The proposed architecture integrates graph neural networks with a learnable global query mechanism and, notably, introduces a prompt-guided learning paradigm. By leveraging historical snapshots as few-shot prompts, the model dynamically captures correlations between target and historical operating conditions, significantly enhancing generalization capabilities under unseen topologies. Furthermore, we design a physics-informed training mechanism that prioritizes branch power flow errors over nodal voltage errors, aligning the optimization objective with critical grid security constraints. To ensure engineering applicability, a physics-informed inference mechanism is also developed, incorporating a residual-based correction module and a specialized post-processing strategy for singular branches to circumvent numerical instability. Comprehensive experiments demonstrate that PhyPro-FM outperforms state-of-the-art methods in accuracy and generalization, validating its superior physical consistency and robustness for practical engineering applications.

0.18

Scalable Self-Supervised Learning for Multiphase AC-OPF in Distribution Systems with Topology Reconfiguration

eess.SY cs.LGmath.OC ·2026-08-25 ·Hoang T. Nguyen, Shaohui Liu, Reetam Sen Biswas, Varsha Pendyala, Nurali Virani +2 more
similarity 0.56
Abstract · Source code will be published following the review process

The proliferation of distributed energy resources (DERs) in distribution grids enables the active coordination of these assets to reduce costs and enable cleaner operations. Realizing this potential requires solving multiphase AC optimal power flow (AC-OPF) quickly across varying loads, DER availabilities, and topology reconfigurations, at much greater speed and scale than conventional nonlinear solvers. Learning-based surrogates can offer millisecond inference, yet existing methods target largely balanced transmission systems and do not scale to the multiphase, unbalanced, and reconfigurable nature of distribution feeders at utility scale. We present the Penalty + Sequential Linearized Feasibility Seeking (SLFS) algorithm, a self-supervised learning framework for multiphase distribution AC-OPF under switch-induced topology changes. Penalty+SLFS requires no labeled optimal solutions and trains directly from the AC-OPF objective and constraints through a differentiable fixed-point power flow solver, avoiding expensive label generation and admitting robust training procedures. Topology changes are handled efficiently using Sherman-Morrison-Woodbury updates of the admittance-matrix inverse, while an M-step Jacobian approximation accelerates differentiation through the power flow solver. At inference, SLFS repairs any infeasible predictions, providing feasibility guarantees with low computational overhead. On IEEE feeders ranging from 13 to 8,500 nodes, Penalty+SLFS achieves negligible optimality gaps and near-zero constraint violations, delivers up to three orders of magnitude speedups over IPOPT, and remains robust under large distributional shifts, demonstrating a viable path toward real-time, topology-aware AC-OPF for large-scale distribution grids.

0.23