A simulation based dataset of faults and events for machine learning in power systems

Georg Kordowich, Jonathan Loebel, Julian Oelhaf, Andreas Maier, Siming Bayer, Christian Bergler, Johann Jaeger

eess.SY ·submitted 2026-08-20 08:19 UTC · v1

Abstract

The integration of inverter-based renewable energy sources into electric grids challenges conventional power system protection. Machine learning-based solutions can address these challenges by utilizing available data in modern smart grids. However, the lack of open datasets prevents reproducibility and fair comparisons between different approaches and their results, which hinders further progress. Therefore, this paper presents EvEMTBench, a synthetic dataset of faults and events generated using electromagnetic transient simulations. The physical plausibility of the power system simulation is ensured by validating the simulation parameters against established literature and providing comprehensive documentation of the simulation procedure. The dataset is designed for training, fine-tuning, and benchmarking machine learning models by providing synchronized point-on-wave voltage and current measurements at 9600 Hz across a diverse set of topologies and voltage levels. The inclusion of a wide range of fault and operating events allows the utilization of EvEMTBench for different tasks like incipient fault detection, fault localization, or event detection.

Closest papers

Nearest neighbours by meaning across the whole index.

A Systematic Evaluation of Machine Learning Methods for Fault Detection and Line Identification in Electrical Power Grids

cs.LG eess.SP ·2026-09-15 ·Julian Oelhaf, Georg Kordowich, Paula Andrea Pérez-Toro, Tomás Arias-Vergara, Andreas Maier +2 more
publishedhighly cited similarity 0.75
Abstract · Accepted at ICASSP 2025. 5 pages, 4 figures. Published version: DOI 10.1109/ICASSP49660.2025.10890544

The integration of renewable energy sources into the electrical grid introduces complex challenges in fault detection and coordination of grid recovery mechanisms. Traditional relay protection systems, which operate based on static rules and predefined thresholds, are inadequate for addressing these challenges, particularly in detecting and isolating faults such as short circuits. Consequently, the conventional methodologies applied to electrical network protection frequently fail to achieve optimal performance in fault detection, especially in terms of adherence to safety standards and the selective limitation of damage. Recent research indicates that machine learning (ML)-based approaches can effectively tackle these issues; however, variations in grid configurations and analysis windows have impeded consistent comparative assessments. In this study, we assess the efficacy of various ML models in detecting electrical faults and pinpointing defective transmission lines within a 10 ms measurement interval - a critical time-frame for real-time operational viability, for the first time. The most effective model attained an F1 score of 0.991 +/- 0.018 and demonstrated a processing time of 0.342ms +/- 0.509ms.

0.52

EvEMTBench: An Open Benchmark for Machine Learning in Power System Protection

eess.SY cs.LG ·2026-09-23 ·Julian Oelhaf, Georg Kordowich, Christian Bergler, Andreas Maier, Johann Jäger +1 more
benchmarkcode/data similarity 0.74
Abstract · 15 pages, 3 figures. Supplementary information included. Code: https://github.com/EvEMTBench/evemtbench-benchmark

Studies of machine-learning-based power system protection are difficult to compare because task definitions, measurement access, data partitions, metrics, and generalization conditions often differ. EvEMTBench addresses this gap with an open, executable, and versioned benchmark that fixes these evaluation choices while leaving model design open. Across four grids spanning 20-345 kV, it defines 12 protection and event-analysis functions instantiated as 24 scored tasks and supports structured evaluation across observability conditions, predefined distribution shifts, and zero-shot and fine-tuned cross-grid transfer. Committed partitions, leakage controls, and reproducible reporting provide a common basis for comparing future methods. A reference evaluation spanning trivial, conventional, feature-based, and deep-learning baselines shows that wider observability is not uniformly beneficial, shifted conditions can reveal failures not apparent in-distribution, and cross-grid transfer is substantially stronger for fault detection than for fault localization. Protection-relevant diagnostics identify failure modes not apparent from primary metrics alone. EvEMTBench therefore makes generalization in machine-learning-based protection an explicit and reproducible evaluation problem.

0.22

Protection-Oriented Assessment of Machine Learning-Based Fault Detection in Power Systems

cs.LG eess.SP ·2026-11-13 ·Julian Oelhaf, Georg Kordowich, Changhun Kim, Christian Bergler, Andreas Maier +2 more
publishedhot direction similarity 0.66
Abstract · 9 pages, 3 figures, 5 tables. Accepted for oral presentation at the 21st International Conference on Developments in Power System Protection…

Machine learning (ML)-based fault detectors are increasingly proposed for power system protection, yet aggregate metrics can obscure the consequences of false and missed trips. We present a protection-oriented assessment of three ML detectors and a sequence-current reference on PROTECT-90, comprising 9,022 simulated fault episodes on a 90 kV double-circuit line. The assessment combines five window conditions, causal window-end labelling, episode-grouped cross-validation, and operating-point selection under a fixed security budget. It reports security, dependability, detection timing, decision margins, and episode-level nuisance assertions. Gradient-boosted trees, a convolutional neural network, and logistic regression achieve AUC-ROC values above 0.999, yet at a security budget of $10^{-3}$ their developed-fault missed-trip rates range from 0.007% to 1.99%. Post-clearing false-trip rates of approximately 0.12-0.16% per window coexist with nuisance assertions in 11.3-19.1% of episodes. Among the analysed physical descriptors, missed trips are most consistently associated with higher fault resistance within the sampled range. An analytical current proxy suggests a fault-current gradient only partly reproduced by waveform-derived current (rank correlation 0.62). No single topology state or faulted phase consistently dominates within the sampled domain. Because PROTECT-90 contains fault episodes only, security is assessed on pre-fault and post-clearing windows rather than independent non-fault disturbances.

0.27

A Standardized Framework for Machine Learning in Power System Protection

cs.LG cs.AIeess.SP ·2026-08-20 ·Julian Oelhaf, Georg Kordowich, Paula Andrea Pérez-Toro, Christian Bergler, Johann Jäger +2 more
publishedbenchmarkcode/data similarity 0.66
Abstract · 32 pages, 4 figures, 26 tables. Code: https://github.com/julianoelhaf/protection-eval-framework. Dataset: PROTECT-90, doi:10.5281/zenodo.211…

Studies of machine-learning-based power-system protection increasingly report near-perfect scores, yet the meaning of those scores depends strongly on the evaluation setting. Protection task, physical scope, measurements, timing, targets, preprocessing, and validation often vary jointly and remain incompletely specified. This paper proposes a standardization-oriented framework that treats evaluation design as part of the scientific contribution. It defines seven required study dimensions: protection objective, physical scope, observability, timing and decision windows, targets and sample validity, validation protocol, and evaluation outputs. The framework is instantiated in a bounded case study on the public PROTECT-90 electromagnetic-transient benchmark, comprising 9022 simulated episodes from a 90 kV double-line topology, for onset-conditioned fault classification and localization. Under centralized sensing, simulation-metadata-aligned 20 ms windows, and episode-grouped validation, a multi-layer perceptron (MLP) achieved a five-fold mean macro-averaged F1 score of 0.991 +/- 0.001 for classification and a localization mean absolute error of 10.20 +/- 0.25% of line length (mean +/- std across episode-grouped folds). Extending the decision horizon to 50 ms preserved this task-dependent performance asymmetry, while reduced observability approximately doubled the MLP localization error but had little effect on classification. A synchronized two-ended conventional locator outperformed the learning locators under its richer clean information set, and measurement degradation showed that clean predictive performance did not determine robustness. The framework turns evaluation assumptions into explicit, reproducible evidence and provides a basis for more comparable, auditable evaluation and future certification-oriented assessment of machine-learning protection functions.

0.81

A Benchmark Graph Dataset for Transient Stability Assessment of the IEEE 9-Bus System: 20,000 Scenarios with Full Generator Trajectories

eess.SY ·2026-08-18 ·Hussein Suprême, Martin de Montigny, Arnaud Zinflou
publishedbenchmark similarity 0.65
Abstract · Descriptor Open dataset IEEE9

Transient stability assessment determines whether a power system retains synchronism after a large disturbance. Machine-learning surrogates can accelerate it, but progress is limited by the lack of open datasets that combine dynamic ground truth, network graph structure, and machine parameters. We release a benchmark of 20,000 three-phase-to-ground fault scenarios on the IEEE 9-bus system. Each scenario couples an AC power-flow operating point with a detailed electromagnetic-transient simulation of the post-fault response. Every record provides the network as an attributed graph (nine buses, eighteen directed branches, ten node and twelve edge features), the full rotor-angle and speed trajectories of the three generators, the static machine constants, the fault description, and a center-of-inertia binary stability label. Wide load and generation scalings across eighteen fault locations yield a near-balanced distribution (48.96\% stable, 51.04\% unstable). Generation is deterministic and fully reproducible through fixed seeds and public code. The dataset is distributed on IEEE DataPort under a persistent DOI and supports stability classification, trajectory prediction, margin and critical-clearing-time estimation, and the comparison of topology-aware, physics-based, and hybrid learning methods.

0.43

Deep Learning-Based Detection of Electrical Faults and Power Quality Disturbances in Aerospace Power Systems

eess.SP cs.LGeess.SY ·2026-09-09 ·Ian C. Guzmán, Radu Babiceanu, Berker Peköz
top venuecode/data similarity 0.64
Abstract · Accepted for publication in IEEE Transactions on Aerospace and Electronic Systems. Pending journal reference/external DOI

More Electric Aircraft require fast and reliable monitoring of high-frequency electrical networks, yet most power quality disturbance and fault diagnosis methods are developed for conventional 50 or 60 Hz grids. This work presents a hardware-aware deep learning framework for multiclass detection of electrical faults and power quality disturbances in a 400 Hz aerospace power system. A high-fidelity simulation model inspired by the Boeing 787 electrical architecture generates voltage and current waveforms for 21 normal, disturbance, switching, open-circuit, and short-circuit conditions. Two datasets, each containing 73,500 samples, are formed from one-dimensional time-series signals and short-time Fourier transform time-frequency representations. Signal-processing augmentation, domain randomization, and class-specific generative adversarial networks increase waveform diversity, and the time-series dataset is released through IEEE DataPort. We compare 1D and 2D convolutional neural networks, long short-term memory networks, CNN-LSTM hybrids, ResNet, MobileNet, and VGG models under common training conditions. A compact ResNet provides the best accuracy-complexity tradeoff, achieving 96.94 percent software test accuracy with 175,685 parameters. After 8-bit quantization and deployment on a Xilinx Zynq UltraScale Plus MPSoC ZCU102, the model achieves 95.87 percent accuracy and a measured mean neural-network accelerator latency of 6.90 ms per input record. The results establish simulation-based, accelerator-level feasibility for embedded edge AI in aircraft electrical health monitoring and motivate future end-to-end data acquisition and experimental validation.

0.52

Lyapunov Exponents in Power Systems: A Survey of Theory and Applications in Stability, Control, Forecasting, and Protection

eess.SY ·2026-10-16 ·Mohammad Almomani, Venkataramana Ajjarapu
survey similarity 0.63
Abstract

Lyapunov exponents (LEs) are fundamental metrics from nonlinear dynamical systems theory that quantify the average exponential rate of divergence or convergence of nearby trajectories in phase space. Over the past three decades, LEs have emerged as powerful tools across a wide range of power system problems, including transient and voltage stability assessment, chaos detection and mitigation, short-term load and renewable energy forecasting, and fault diagnosis. This paper presents a comprehensive review of these applications, covering more than 165 publications spanning from the early demonstrations of chaos in simplified machine models (1990s) to the most recent data-driven and machine-learning-augmented approaches applied to inverter-based resource (IBR)-dominated grids (2024--2026). The review is organized into four principal application domains: (i) stability analysis and real-time monitoring, (ii) chaos characterization and control, (iii) forecasting and predictability analysis, and (iv) protection, fault diagnosis, and condition monitoring. For each domain, we trace the evolution of methods, compare model-based and data-driven LE estimation strategies, identify key benchmarks and validation gaps, and outline the most pressing open research problems.

0.25

PowerModels-ACOPF-AI: On-the-Fly Machine Learning Approach for Solving AC Optimal Power Flow Integrating Renewable Energy Sources

eess.SY ·2026-09-16 ·Bhuban Dhamala, Jose Tabarez, Anup Pandey
benchmark similarity 0.63
Abstract

The increasing complexity of modern power systems, driven by high renewable penetration, load variability, and operational uncertainty, demands fast and reliable solutions to the AC optimal power flow problem (AC-OPF). Traditional optimization methods, though accurate, often struggle with scalability and high computational burdens, making them impractical for real-time use in large networks. This paper introduces PowerModels-ACOPF-AI, a two-stage Bayesian Neural Network (BNN) surrogate designed to predict generator set points, bus voltages, and phase angles with uncertainty. The framework integrates a performance-sensitive on-the-fly learning mechanism that identifies regions of degraded prediction accuracy and dynamically retrains with additional AC-OPF solutions generated by PowerModels.jl. This self-adaptive loop ensures robust performance, enabling the model to maintain accuracy under novel or highly variable operating conditions. Validation on benchmark test systems of different sizes, namely the 30-bus, 200-bus, and 500-bus networks, demonstrates strong generalization capability, efficient handling of stochastic renewable injections, and the ability to provide rapid, uncertainty-aware predictions. Beyond predictive accuracy, the proposed approach offers practical value as both a real-time advisory tool for system operators and a fast initializer for conventional solvers, thus supporting resilient and efficient grid operation in future power systems.

0.16