CS Paper Radar

Deep Learning-Based Detection of Electrical Faults and Power Quality Disturbances in Aerospace Power Systems

Ian C. Guzmán, Radu Babiceanu, Berker Peköz

eess.SP cs.LGeess.SY ·submitted 2026-09-09 17:19 UTC · v1
top venuecode/data

Abstract

More Electric Aircraft require fast and reliable monitoring of high-frequency electrical networks, yet most power quality disturbance and fault diagnosis methods are developed for conventional 50 or 60 Hz grids. This work presents a hardware-aware deep learning framework for multiclass detection of electrical faults and power quality disturbances in a 400 Hz aerospace power system. A high-fidelity simulation model inspired by the Boeing 787 electrical architecture generates voltage and current waveforms for 21 normal, disturbance, switching, open-circuit, and short-circuit conditions. Two datasets, each containing 73,500 samples, are formed from one-dimensional time-series signals and short-time Fourier transform time-frequency representations. Signal-processing augmentation, domain randomization, and class-specific generative adversarial networks increase waveform diversity, and the time-series dataset is released through IEEE DataPort. We compare 1D and 2D convolutional neural networks, long short-term memory networks, CNN-LSTM hybrids, ResNet, MobileNet, and VGG models under common training conditions. A compact ResNet provides the best accuracy-complexity tradeoff, achieving 96.94 percent software test accuracy with 175,685 parameters. After 8-bit quantization and deployment on a Xilinx Zynq UltraScale Plus MPSoC ZCU102, the model achieves 95.87 percent accuracy and a measured mean neural-network accelerator latency of 6.90 ms per input record. The results establish simulation-based, accelerator-level feasibility for embedded edge AI in aircraft electrical health monitoring and motivate future end-to-end data acquisition and experimental validation.

Comment
Accepted for publication in IEEE Transactions on Aerospace and Electronic Systems. Pending journal reference/external DOI
DOI
10.1109/TAES.2026.3733949

Closest papers

Nearest neighbours by meaning across the whole index.

One-Cycle Fault Classification and Faulted-Line Identification on the PROTECT-90 Dataset: An Initial Application Benchmark

eess.SY cs.LG ·2026-10-02 ·Emad Abukhousa, Abdulaziz Qwbaiban, Saman Zonouz, A. P. Sakis Meliopoulos
benchmarkcode/data similarity 0.72
Abstract

Open electromagnetic-transient datasets are beginning to make reproducible learning-based protection studies possible, but the practical use of these datasets still requires application-level benchmarks that define timing, sensing, and validation assumptions. This paper presents an initial application benchmark on the recently released PROTECT-90 dataset for two protection-oriented tasks: fault-type classification and discrete faulted-line identification. A compact one-dimensional convolutional neural network (CNN) is evaluated using post-inception windows of 0.25, 0.5, 1, and 2 cycles under strict episode-wise splitting. A non-convolutional multilayer perceptron (MLP) is also trained as an architecture-control baseline. The results show that both tasks are nearly saturated under full observability, with one-cycle test accuracies of 99.84% for fault type and 100.00% for line identification. The main performance variation appears under reduced observability: current-only inputs preserve line identification accuracy at 100.00%, whereas voltage-only inputs reduce line identification accuracy to 53.09% with the CNN and 50.57% with the MLP. This indicates that the limiting factor is measurement information rather than neural architecture. Additional stratified checks show stable performance across topology states and fault-resistance bins, while CPU inference contributes only 0.528 ms to the one-cycle total decision time of 20.53 ms.

0.29

A Machine Learning Framework for Fault Detection, Isolation, and Severity Prediction of Autonomous VTOL Aircraft

cs.LG ·2026-09-12 ·Ripon C. Sarker, Pedram H. Dabaghian, Raman Goyal, Atanu Halder
published similarity 0.65
Abstract

Fault detection in autonomous VTOL aircraft is critical because even minor component degradations can rapidly destabilize multirotor vehicles operating in complex, safety-critical environments, motivating robust fault detection and estimation strategies capable of identifying early signs of rotor damage; however, real-flight fault detection remains challenging due to sensor noise, environmental disturbances, and the nonlinear aerodynamics of multirotor platforms. This study proposes a comprehensive machine-learning framework for rotor fault detection, isolation, and severity prediction using real flight data. A convolutional neural network (CNN) architecture is developed to learn spatio-temporal patterns from multivariate flight dynamics, enabling direct inference of both the faulted rotor and its damage level. The framework is first validated using simulated data generated by a data-generative model, and experimental validation is then performed on a hexacopter by introducing controlled blade-tip breakage. The trained model achieves rotor-wise fault classification accuracies above 99% and severity estimation accuracy of 96% within a 1% tolerance in experimental data, demonstrating strong generalization and supporting real-time health monitoring for autonomous VTOL systems.

0.36

An Empirical Benchmark of Deep Time-Series Models for Smart Meter Energy Forecasting

cs.LG ·2026-08-19 ·Behnaz Kavoosighafi, Maria Eidenskog, Wiktoria Glad, Katerina Vrotsou
publishedbenchmarkcode/data similarity 0.64
Abstract

Accurate forecasting of energy consumption is important for the efficient operation of power systems, with direct implications for operational costs, energy management, and system maintenance. Due to the availability of extensive high-resolution consumption data from smart meters, data-driven methods have been used for short-term and long-term forecasting. However, their comparative performance on real-world smart meter data is still not well studied. In this paper, we present an empirical benchmark of nine modern deep learning models for time-series forecasting, including linear, MLP-based, convolutional, and Transformer architectures. We evaluate these models on two publicly available smart meter datasets. Our analysis focuses on three factors that strongly affect forecasting performance: the length of historical input, the prediction horizon, and the choice of model architecture. We show that extending the historical context improves accuracy, but only up to a saturation point, after which additional input provides limited benefit. In contrast, accuracy decreases as the prediction horizon increases. We also investigate the trade-off between prediction accuracy and computational complexity, and assess the statistical significance and practical magnitude of performance differences across models. Our results show that deep learning models consistently outperform classical baselines, while lightweight architectures achieve relatively similar performance at significantly lower computational cost. Additionally, architectural differences only become meaningful at longer forecasting horizons and on more heterogeneous datasets. Finally, a subgroup analysis across geodemographic and household categories shows that model choice has limited impact for most population segments.

0.58

A simulation based dataset of faults and events for machine learning in power systems

eess.SY ·2026-08-20 ·Georg Kordowich, Jonathan Loebel, Julian Oelhaf, Andreas Maier, Siming Bayer +2 more
similarity 0.64
Abstract

The integration of inverter-based renewable energy sources into electric grids challenges conventional power system protection. Machine learning-based solutions can address these challenges by utilizing available data in modern smart grids. However, the lack of open datasets prevents reproducibility and fair comparisons between different approaches and their results, which hinders further progress. Therefore, this paper presents EvEMTBench, a synthetic dataset of faults and events generated using electromagnetic transient simulations. The physical plausibility of the power system simulation is ensured by validating the simulation parameters against established literature and providing comprehensive documentation of the simulation procedure. The dataset is designed for training, fine-tuning, and benchmarking machine learning models by providing synchronized point-on-wave voltage and current measurements at 9600 Hz across a diverse set of topologies and voltage levels. The inclusion of a wide range of fault and operating events allows the utilization of EvEMTBench for different tasks like incipient fault detection, fault localization, or event detection.

0.50

A Systematic Evaluation of Machine Learning Methods for Fault Detection and Line Identification in Electrical Power Grids

cs.LG eess.SP ·2026-09-15 ·Julian Oelhaf, Georg Kordowich, Paula Andrea Pérez-Toro, Tomás Arias-Vergara, Andreas Maier +2 more
publishedhighly cited similarity 0.64
Abstract · Accepted at ICASSP 2025. 5 pages, 4 figures. Published version: DOI 10.1109/ICASSP49660.2025.10890544

The integration of renewable energy sources into the electrical grid introduces complex challenges in fault detection and coordination of grid recovery mechanisms. Traditional relay protection systems, which operate based on static rules and predefined thresholds, are inadequate for addressing these challenges, particularly in detecting and isolating faults such as short circuits. Consequently, the conventional methodologies applied to electrical network protection frequently fail to achieve optimal performance in fault detection, especially in terms of adherence to safety standards and the selective limitation of damage. Recent research indicates that machine learning (ML)-based approaches can effectively tackle these issues; however, variations in grid configurations and analysis windows have impeded consistent comparative assessments. In this study, we assess the efficacy of various ML models in detecting electrical faults and pinpointing defective transmission lines within a 10 ms measurement interval - a critical time-frame for real-time operational viability, for the first time. The most effective model attained an F1 score of 0.991 +/- 0.018 and demonstrated a processing time of 0.342ms +/- 0.509ms.

0.52

Beyond Accuracy: Physics-Informed Evaluation of ANN-based Power Flow Solvers under System Shift

eess.SY ·2026-11-10 ·Dong Liu, Jochen Stiasny, Jochen Cremer, Pedro P. Vergara
similarity 0.63
Abstract

Recent advances in artificial deep learning-based power flow (PF) solvers have primarily focused on improving estimation accuracy, while their physical feasibility and operational reliability under realistic system variations remain insufficiently evaluated. This paper proposes a physics-informed evaluation framework for deep learning-based PF solvers under topology and load distribution shifts. Beyond conventional voltage-domain errors, the framework incorporates KCL gaps, branch-flow gaps, KVL residuals, continuous feasibility scores, and strict, practical, and relaxed PF feasibility rates. Four case studies are designed to investigate topology shifts, mixed topology training, load distribution shifts, and combined topology distribution shifts. Eight ANN architectures, including graph input models, load-only baselines, and physics-informed neural networks, are evaluated under consistent settings. The results demonstrate that low estimation errors do not necessarily correspond to physically feasible or operationally reliable PF solutions, particularly under combined system shifts. The proposed framework establishes an initial foundation and analysis for the development and verification of trustworthy deep learning-based PF solvers, providing support for their reliable deployment in future AI-enabled power system analysis.

0.09

Lightweight Time-Frequency Vibration Sensing for Consumer Device Condition Monitoring

eess.SP cs.LG ·2026-10-09 ·Po-Heng Chou, Jen-Yu Chiu, Chun-Yu Yeh, Wei-Lung Mao, Walid Saad
benchmark similarity 0.62
Abstract · 6 pages, 3 figures, and 4 tables. Submitted to the 2027 IEEE International Conference on Consumer Electronics (ICCE 2027)

Consumer rotating devices, including washing machines, air conditioners, electric fans, robotic vacuum cleaners, and home fitness equipment, increasingly rely on vibration sensing for intelligent condition monitoring and predictive maintenance. Ensuring reliable operation in these resource-constrained appliances requires efficient, lightweight artificial intelligence (AI) solutions capable of processing non-stationary signals under real-world operational interference. This paper proposes a lightweight AI-assisted vibration sensing framework that employs continuous wavelet transform (CWT) and Hilbert-Huang transform (HHT) to convert one-dimensional (1-D) vibration time-series signals into two-dimensional (2-D) time-frequency representations. These representations are subsequently analyzed using lightweight deep learning architectures, specifically MobileNetV3-Small, ConvNeXt-Tiny, and the You Only Look Once version 11 classification model (YOLOv11-cls). Public bearing benchmark datasets, including Case Western Reserve University (CWRU), Paderborn University (PU), and Intelligent Maintenance Systems (IMS), are utilized as representative rotating components to investigate model generalization. The proposed framework is designed with eventual embedded deployment in consumer electronics in mind. Experimental results demonstrate that CWT combined with YOLOv11-cls achieves high diagnostic accuracy, while MobileNetV3-Small provides an attractive low-latency alternative for computationally constrained edge platforms. Conventional random splitting is also compared with dataset-specific structured isolation. The results highlight the importance of avoiding data leakage and quantify tradeoffs in classification accuracy, parameter count, floating-point operations (FLOPs), model footprint, preprocessing cost, and central processing unit (CPU) inference latency.

0.23

A Time-Frequency Dual-Domain Multi-Scale Convolutional Neural Network for Bearing Fault Diagnosis under Strong Noise

cs.LG ·2026-08-10 ·Yanxi Ding, Tingyue Jia
similarity 0.62
Abstract

To address the degradation of bearing fault diagnosis accuracy under strong noise, this paper proposes a time-frequency dual-domain multi-scale convolutional neural network. The time-domain branch employs three parallel convolutional kernels to capture multi-scale impulse features, while the frequency-domain branch applies the Fast Fourier Transform to extract noise-robust spectral structure information. Features from both branches are fused for fault classification, yielding a compact model of 110,122 parameters. Experiments on the CWRU bearing dataset across seven signal-to-noise ratio levels demonstrate that the proposed method achieves 99.75% accuracy under clean conditions and maintains 92.50% at -4 dB SNR, representing a 7.25 percentage-point improvement over the single-domain baseline with monotonically increasing gains under stronger noise. Ablation experiments validate the independent performance contributions of the time-domain multi-scale branch and the frequency-domain branch. Comparative experiments against WDCNN, DRSN-CW, MCNN, and 1D-LeNet confirm the superiority of the proposed method under strong noise conditions.

0.04