CS Paper Radar

SDoH-Aware Narrative Anchoring Bias in Medical LLMs for Trustworthy Clinical Decision Support

Ahnaf Atef Choudhury, Ramkrishna Saha

cs.CL cs.AI ·submitted 2026-08-24 04:58 UTC · v1
top venuecode/data

Abstract

Medical large language models are often judged by how many clinical questions they answer correctly. That view is useful, but it misses a practical risk. A model may know the right answer and still change its response when the same case is written in a different patient voice. This paper evaluates that risk as SDoH aware narrative anchoring bias. We use NarrativeShield SDoH MedQA, a counterfactual medical question answering dataset in which each case appears in persona based narratives while the answer key remains fixed. The dataset is reshaped from wide format into case grouped persona rows. We evaluate three open source instruction tuned LLMs from the Qwen2.5 family: 1.5B, 3B, and 7B. The final experiment uses 300 clinical cases and produces 8,100 model responses across three prompting conditions. We report persona level accuracy, counterfactual consistency, correct consistency, and narrative sensitivity error. Qwen2.5 7B achieves the best accuracy at 56.33 percent and the best correct consistency at 40.33 percent. Paired McNemar exact tests show significant accuracy gains for 7B over 3B in all prompt settings. Even so, narrative sensitivity remains, with the lowest error still at 31.67 percent. These results suggest that trustworthy clinical decision support should be evaluated by both average correctness and stability across medically equivalent patient narratives.

Comment
Accepted for publication at 10th International Artificial Intelligence and Data Processing Symposium (IDAP'26)

Closest papers

Nearest neighbours by meaning across the whole index.

MTDiag: A Multi-Turn Diagnostic Dataset Towards Clinically Meaningful LLM Evaluation

cs.CL ·2026-08-25 ·Pia Chouayfati, Alexander M. Fichtl, Miriam Anschütz, George Doumat, Georg Groh
published similarity 0.69
Abstract · 20 pages, published in the SIGDIAL 2026 conference proceedings, see https://aclanthology.org/2026.sigdial-1.58/

Clinical diagnosis is fundamentally interactive and incremental, yet the dominant paradigm for evaluating Large Language Models (LLMs) in medicine remains static QA benchmarks or template-based dialogues. These benchmarks say little about whether a model can serve as a diagnostic agent in a dynamic clinical encounter, with LLMs showing significant accuracy and reliability degradation in multi-turn settings. To address this issue, we present MTDiag, a large multi-turn diagnostic dialogue dataset constructed from three heterogeneous sources: DDXPlus, MIMIC-IV, and published case reports (AJCR), covering common ED presentations as well as long-tail rare and atypical conditions. All cases are normalized into a canonical schema anchored in the most comprehensive and widely-adopted medical knowledge bases (UMLS concept identifiers, with ICD-10 diagnosis codes). We release the schema, a UserLM-8B-based utterance-generation pipeline, and the physician-validated dataset that converts structured clinical evidence into natural-language utterances. Importantly, we introduce and motivate clinical knowledge-grounded metrics for evaluating LLMs as diagnostic agents, beyond diagnostic accuracy, for the task of multi-turn differential diagnosis.

0.63

Structured Clinical Memory as Context for Probabilistic Decision Models: A Synthetic Evaluation with Jev

cs.AI ·2026-11-03 ·Jash Sayani, Gaurang Karwande, Achinth Bharadwaj
theory similarity 0.67
Abstract · 4 pages, 1 figure, 8 tables

Longitudinal clinical context is often distributed across noisy, repetitive forms and narrative records. We study whether a compact structured memory can improve a probabilistic decision model's answers when the underlying patient vignette is already available. We created 30 fully synthetic cases spanning twelve clinical domains, paired each with synthetically generated structured memory, and evaluated 120 typed questions with Jev. The raw-vignette arm achieved 90.0% accuracy (95% normal-approximation confidence interval: 84.6%-95.4%); adding memory achieved 93.3% (88.9%-97.8%). Five questions changed from incorrect to correct and one changed in the opposite direction (exact McNemar $p=0.219$). Choice log loss decreased from 0.258 to 0.175 and binary Brier score from 0.054 to 0.022. Memory added 310 input tokens per call on average, while observed mean latency was unchanged at approximately 0.5 seconds. These results are directionally positive rather than clinically validating: the cases are synthetic, the labels are single-author judgments, and the memory is an oracle upper bound rather than extracted production output. The pilot supports evaluating structured clinical memory as a reusable state interface for decision models.

0.10

Medical Fine-Tuning Reshapes, Not Reduces, Patient-Facing AI Risk: A Rubric-Based, LLM-Judge Evaluation Framework

cs.AI cs.CL ·2026-10-17 ·Savan Doshi
benchmark similarity 0.67
Abstract

Patient-facing medical question answering with large language models (LLMs) is moving from research demonstrations to production deployments, yet evaluation remains anchored on factual correctness. Factuality is necessary but not sufficient: a response can be factually grounded and still issue a directive that, if acted on, would harm the patient. We introduce a risk-sensitive evaluation framework that scores responses by the presence and severity of six categories of risk-bearing language (treatment directives, contraindications, dosage expressions, urgency-triage cues, high-alert medication mentions, and overconfident assertions), anchored on published clinical harm taxonomies. Severity is classified by a three-judge LLM ensemble. We apply this framework to six 7-9B instruction-tuned models, three general (Mistral-7B, Phi-3.5-mini, Llama-3.1-8B) and three medically adapted (BioMistral-7B, OpenBioLLM-Llama3-8B, Med42-Llama3-8B), on 200 real patient questions from the K-QA benchmark. Two findings emerge. First, ensemble risk-bearing language is statistically independent of factual hallucination rate (pooled Spearman $ρ= -0.065$, $n = 300$, 95% CI $[-0.18, +0.05]$; distance correlation $= 0.10$, independence test $p = 0.24$). Second, medical fine-tuning does not reduce aggregate risk but reshapes it: continued-pretraining adaptations (BioMistral, OpenBioLLM) consistently suppress high-alert medication mentions while amplifying overconfident assertions, whereas clinical instruction-tuning (Med42) suppresses dosing only, without amplifying overconfidence. Per-category Krippendorff $α$ is fair to good for the four linguistically anchored categories (0.53-0.71) and low for the two clinical-judgment-dependent categories (0.19, 0.31), indicating where automatic safety evaluation is and is not yet reliable. We release the rubric, judge prompts, and evaluation code.

0.16

Hindsight Bias in Clinical Temporal Reasoning: How Future Data Exposure Affects Large Language Model Judgment

cs.CL cs.AI ·2026-09-11 ·Misaki Matsuura, Sayantan Kumar, Ojas Kadam, Jeremy C. Weiss
benchmarkhighly cited similarity 0.66
Abstract · Machine Learning for Health Symposium (ML4H 2026)

Clinical decisions are prospective, but clinical language models are often evaluated on retrospective records that reveal the final diagnosis, treatment response, and outcome. Such evaluations may reward the use of future information rather than reasoning under the uncertainty present at the decision point. We introduce a paired benchmark for measuring outcome-conditioned shifts consistent with hindsight bias in clinical temporal reasoning. It contains 171 case reports from the PubMed Central Open Access Subset---40 sepsis and 131 GLP-1/diabetes cases---represented as both textual narratives and human-annotated and LLM-generated textual time series (TTS). For each case, questions are tied to a clinically meaningful cutoff and paired with a prospective reference answer and an outcome-consistent \emph{hindsight trap}. Models answer each question using either a TTS truncated at the cutoff or the complete timeline; additional conditions vary the narrative source (original or synthetic) and TTS annotation source (human or LLM). We evaluate accuracy (Acc), hindsight trap rate (HTR), answer instability rate (AIR), and hindsight bias rate (HBR), each of which captures different signals of hindsight bias. Across GPT 5.6 Sol, Gemma 4, GLM 5.2, and Opus 5, full timeline exposure produces consistent hindsight-sensitive shifts, while temporal masking reduces bias without lowering accuracy.

0.46

When Confidence Fails: Overconfidence in LLMs under Uncertainty and Missing Clinical Information

cs.CL cs.AIcs.HCcs.LG ·2026-08-10 ·Maryam Tahermazandarani, Adnan Mahmood, Fahmida Islam, Quan Z. Sheng
published similarity 0.65
Abstract

Large Language Models (LLMs) have achieved strong performance in medical question answering and clinical reasoning tasks. However, their reliability under uncertainty remains poorly understood which raises critical concerns for deployment in high-stakes clinical settings. In such environments, incorrect predictions are inherently risky, but confident incorrect predictions can be particularly harmful as they may mislead clinical decision-making. In this paper, we conduct a systematic behavioral analysis of LLMs under clinical information uncertainty. We propose an evaluation framework based on the MedMCQA dataset consisting of two complementary uncertainty settings. First, we introduce linguistic uncertainty cues through prompt modifications to simulate ambiguous clinical contexts. Second, we construct an answer removal setting, wherein the correct option is deliberately excluded mandating the model to recognize insufficient information and abstain. We analyze both model accuracy and confidence behavior using multiple calibration metrics including calibration gap, Expected Calibration Error (ECE), and Unsafe Confident Error Rate (UCER) across 500 medical questions. Our results reveal a consistent failure mode, i.e., although accuracy degrades under increasing uncertainty, model confidence remains misaligned with accuracy. This leads to a substantial increase in unsafe confident errors, indicating that model confidence remains largely insensitive to clinically meaningful information loss. Furthermore, we observe significant variation across models in their ability to abstain when the correct answer is unavailable, with some models persistently producing high confidence hallucinated answers. These findings expose critical limitations in the epistemic reliability of current LLMs and highlight the need for uncertainty aware evaluation methods prior to their deployment in clinical workflows.

0.22

KlinikeBench: Evaluating Language Models Beyond Diagnostic Accuracy

cs.CL cs.AI ·2026-09-29 ·Xueting Fang, Zehui Li, Yang Yang, Camilla Giovino, Shubh K. Patel +3 more
benchmarkcode/data similarity 0.65
Abstract

Most clinical benchmarks evaluate language models (LMs) on diagnosis using complete case descriptions. In clinical practice, however, patients present information in different ways, and clinicians must obtain relevant history and determine which examinations are needed before reaching a diagnosis. Diagnostic accuracy alone therefore cannot establish whether an agent gathered essential information or conducted an appropriate clinical assessment. Furthermore, existing benchmarks lack professional clinicians' verification. To address this gap, we introduce KlinikeBench, a benchmark of 333 clinician-authored tasks, each providing an isolated sandbox environment with a virtual patient, clinical tools, and task-specific success criteria. More than 35 clinicians contributed to case authoring and benchmark evaluation. In an empirical study, clinicians gave simulated dialogues higher mean quality ratings than reference conversations, which is adapted from real conversation. In each task, an LM has a fixed budget of turns to communicate with the patient, ask about relevant history, request examinations, follow action constraints, and record a final diagnosis. We score these steps separately as well as together. Across 31 models and seven model families, the best-performing models (e.g., GPT-6-astra and Claude Opus 5) succeed on less than 30% of tasks, even though their diagnosis accuracy reaches 90.7%. Some models benefit from talking with the patient; others diagnose well from a complete chart but perform much worse in conversation. Overall, KlinikeBench provides a testbed for evaluating the full clinical encounter and reveals a substantial gap between diagnostic accuracy and performance in interactive clinical assessment. All the code and data is available on https://zehui127.github.io/klinikebench/

0.23

Route, Don't Fix: Regime-Dependent Decoding Correction and a Trajectory-Gated Router for Reliable Clinical LLM Answer Selection

cs.CL cs.AIcs.LG ·2026-09-13 ·Zeyu Dong, Benjamin Wang, Joyee W. Jin
similarity 0.65
Abstract

Large language models (LLMs) are often deemed unsafe for clinical question answering because of their tendency to hallucinate. Retrieval augmentation, fine-tuning, and external verifiers require new infrastructure that clinical governance must approve and may add latency or extra model calls. Inference-time correction uses the model's internal logit signals, but a fixed transformation need not suit every question. A corrector that improves accuracy by about ten percentage points on a truthfulness stress test yields negligible gains on clinical multiple-choice benchmarks, where instruction tuning concentrates output probability on one answer and leaves low terminal entropy. We introduce ALTAS, which reads terminal entropy and late-layer linearity ($R^2$) from one forward pass to choose per question between greedy decoding and late-layer trajectory correction. No classifier, probe, or head is trained; the router operates on candidate-answer logits and adds 6.5% latency overhead. Applied to every question, the correction improves TruthfulQA over greedy at 3B and 8B by 11.4 and 10.0 percentage points, respectively ($p<10^{-10}$). Gated per question, ALTAS retains gains of 8.3 to 9.5 percentage points while keeping MedQA, PubMedQA, and MedHallu within a one-percentage-point do-no-harm band, with no statistically significant differences from greedy. The method passes verification sweeps over frozen thresholds, the scoring rule, and the domain label.

0.21

DocTalk: Enhancing Medical Knowledge Retrieval via Fine-tuned Large Language Models with Chain-of-Thought Reasoning for Robust Clinical Decision Support

cs.AI cs.CLcs.CV ·2026-10-26 ·Asad Gohar, Md Ariful Islam Mozumder, Moon-Il Joo, Hee-Cheol Kim
code/data similarity 0.65
Abstract

Objective: The rapid advancement of large language models (LLMs) in healthcare has opened new possibilities for AI-assisted clinical decision-making; however, safe and effective deployment remains challenging because of hallucination and domain misalignment. This study introduces DocTalk, a doctor-assistive question-answering (QA) system designed to generate concise, chart-grounded responses from de-identified discharge summaries. Methods: We developed a high-fidelity data generation pipeline that produces 500 clinically relevant QA pairs through sentence-level decomposition, chain-of-thought-guided question formulation, and expert review. Six open-source LLMs, including three general-purpose and three biomedical models, were evaluated before and after parameter-efficient instruction tuning using Low-Rank Adaptation (LoRA). The framework integrates prompt engineering, in-context learning, and medically aligned evaluation to support factual and interpretable responses. Results: On DocTalk-QA, instruction tuning produced consistent improvements across lexical, semantic, and clinical fidelity metrics. The best-performing tuned model, Llama-3-Med42-8B, achieved ROUGE-L = 0.40, BERTScore-F1 = 0.76, and UMLS-F1 = 0.49. To examine external generalization beyond the DocTalk-QA dataset, the two best-performing models, Llama-3.1-8B-Instruct and Llama-3-Med42-8B, were evaluated on PubMedQA before and after instruction tuning. Accuracy improved from 0.931 to 0.977 for Llama-3.1-8B-Instruct and from 0.935 to 0.943 for Llama-3-Med42-8B. Conclusion: DocTalk was deployed as a secure web-based platform for interactive EHR querying. These findings suggest that clinically grounded instruction tuning can improve medical QA performance and support practical clinical decision support.

0.26