CS Paper Radar

Infant Care Video Dataset for Classification of Interventions Using Transformers

Igor Bogdanov, James Green

cs.CV cs.AIcs.LG ·submitted 2026-08-24 21:25 UTC · v1
publisheddataset

Abstract

Healthcare documentation in the neonatal intensive care unit (NICU) presents significant challenges, with nurses spending approximately 25\% of their time on record-keeping, while up to 60\% of interventions remain undocumented. Motivated by the need to detect interventions from video automatically, we present the Infant Care Video Dataset (ICVD), a collection of 4,144 videos spanning 12 simulated intervention classes designed for developing automated documentation systems. Our manikin-based approach systematically varies conditions, such as camera angle and clinician skin tone, while ensuring privacy compliance. Using video transformer architectures (TimeSformer and MotionFormer), we establish strong baseline performance (93.97\% and 93.17\% top-1 accuracy) among the 12 infant care classes. Our ablation study comparing temporal models with a framewise approach (23.17\% accuracy) demonstrates a 70.80\% performance gap, validating the need for temporal modeling. The ICVD provides a foundation for developing automated documentation systems to reduce clinical burden in neonatal care environments and improve existing practices.

Comment
Published in the 11th IEEE International Workshop on Medical Computing (MediComp 2025), part of IEEE COMPSAC 2025. Dataset: https://www.infantcaredataset.org
Journal ref
2025 IEEE 49th Annual Computers, Software, and Applications Conference (COMPSAC), pp. 2130-2135, 2025
DOI
10.1109/COMPSAC65507.2025.00299

Closest papers

Nearest neighbours by meaning across the whole index.

TRACER: A Multimodal Harness for Patient Care in Hospitals

cs.CV cs.AI ·2026-10-15 ·Zane Durante, Paul Tang, Keshigeyan Chandrasegaran, Amit Kaushal, Shrinidhi Kowshika Lakshmikanth +9 more
code/data similarity 0.61
Abstract · 37 pages, 4 figures. Code: https://github.com/zanedurante/tracer-harness

Continuous video and clinical records provide complementary information for understanding how patient behavior evolves over a hospital stay. A central challenge is how to represent behavior across the entire stay while preserving access to fine-grained visual and clinical evidence. We introduce TRACER, a training-free multimodal harness that constructs minute-level action records from video and combines them with clinical records into hourly reports. The harness equips an LLM agent with tools to query this hierarchy, inspect relevant video, and retrieve clinical records. To evaluate TRACER, we construct two benchmarks. The first contains 397 annotated one-minute clips spanning 15 atomic actions; the second poses 144 clinician-informed multiple-choice questions, grounded in 264 hours of video and clinical records from two ICU patients. TRACER achieves up to 84.8% accuracy for action detection and 61.0% QA accuracy versus 49.3% for the strongest baseline using the same backbone. Across 280 patients spanning approximately 60,000 camera-hours, TRACER identifies significantly less purposeful activity in patients with a positive delirium assessment during their stay than in those without (p < 0.0001). Our results show that combining continuous video with clinical records can support understanding of patient behavior over time and across patient cohorts without training on protected health data.

0.43

SurgCBVR: A Multi-Domain Benchmark for Content-Based Surgical Video-to-Video Retrieval

eess.IV cs.AI ·2026-11-17 ·Mohammad Eslami, Mousa Moradi, Negin Ghamsarian, Nazlee Zebardast, Jennifer L Lindsey +4 more
benchmark similarity 0.58
Abstract

Hospitals record thousands of hours of surgical video annually, yet these archives remain difficult to search by content. Surgeons cannot readily retrieve similar operations, complications, or workflow events. Existing surgical computer vision primarily produces labels rather than retrieving relevant videos. We introduce SurgCBVR, the first benchmark for content-based video-to-video retrieval in surgery. It integrates eight public datasets across four domains-ophthalmic, laparoscopic, robotic-assisted, and colonoscopy-covering six procedure types, 679 cases, and 76,489 clips (106 hours). SurgCBVR comprises two tiers: Scene, retrieving the same operative state across cases and sites, and Workflow, retrieving and localizing phase transitions and deviations. Scene includes 74,765 clips spanning 40 classes, three temporal granularities, and three playback speeds; Workflow contains 1,724 transition clips. Fixed clip lengths and frame counts, together with phase-classifier oracle and duration-only baselines, help assess label and timing shortcuts. We evaluate six generic and surgical foundation models, two video retrieval methods, and contrastive heads trained on SurgCBVR, using within-dataset, cross-dataset, and pooled-gallery retrieval restricted to the same procedure type. Frozen representations barely outperform a timing-only baseline, transition retrieval approaches chance, and trained heads lose up to half their accuracy across datasets. These findings expose substantial limitations in current video representations and establish SurgCBVR as a benchmark for advancing surgery-aware retrieval.

0.21

The Collection of a Real-World, Large-Scale Dataset for Automated Skill Evaluation in Central Line Dressing Change

cs.CV ·2026-10-16 ·Ummey Tanin, Shannan K. Hamlin, Hsin-Mei Chen, Peizhu, Qian
benchmark similarity 0.56
Abstract · 9 pages

Central line-associated bloodstream infections (CLABSIs) remain a major source of preventable morbidity and mortality in healthcare settings. Proper execution of the central line dressing change (CLDC) procedure is essential for infection prevention, yet current approaches to competency assessment rely primarily on manual ob- servation by clinical educators, making evaluation time-intensive, difficult to scale, and limited in consistency and granularity. These challenges highlight the need for AI-assisted skill evaluation methods that can support more objective, reproducible, and scalable assessment of clinical performance. However, progress in this area has been constrained by the lack of broad-scale, clinically grounded datasets for developing and evaluating such methods. In this work, we present the collection process of a large-scale video dataset for CLDC skill evaluation, comprising 365 recordings of registered nurses collected during the 2026 annual competency exam at Houston Methodist Hospital. Each video is paired with subtask-level temporal annotations and clinical performance assessments spanning 17 subtasks of the procedure. We describe the data collection and curation pipeline, including pilot testing of record- ing configurations, annotation protocol design, and post-collection processing. We further establish the feasibility of video-based skill assessment through benchmark experiments with spatiotemporal deep learning models. This dataset provides a foundation for future research on automated clinical skill assessment, feedback generation, and AI-assisted training in nursing education.

0.37

Operation-aware Multimodal Clinical Decision Support System for ICU Discharge Risk Assessment

cs.LG ·2026-11-09 ·Guoqing Zhang, Rafik Hadfi, Takayuki Ito
benchmarkcode/data similarity 0.56
Abstract · 14 pages, 2 figures. Code available at https://github.com/KuoChing-cmd/ClinicalNoteAgent/

Unplanned 30-day intensive care unit (ICU) readmission is a critical benchmark for evaluating healthcare quality. Most predictive models assume readmission risk depends solely on a patient's individual pathophysiological state, ignoring hospital operational context and resource capacity. In practice, discharge decisions are dynamic trade-offs between patient stability and bed turnover pressures. To address this gap, we develop an Operation-aware Multimodal Clinical Decision Support System (CDSS) for ICU discharge risk assessment. The system combines multi-agent collaborative extraction with self-evolving retrieval-augmented generation (RAG) to eliminate template noise from progress notes, while constructing departmental workload indicators alongside admission flow features, continuous vital signs, and sparse medical codes (ICD/DRG). Addressing severe class imbalance (about 10.5% readmissions) and alarm fatigue, we implement data normalization, class reweighting, and decision-threshold calibration. In 20 independent runs across 20,000 ICU stays from MIMIC-III, empirical findings demonstrate that: vital signs alone have limited predictive capacity under real-world class imbalance (PR-AUC of 0.1387 +/- 0.0086); directly concatenating raw text embeddings degrades decision tree performance (XGBoost and LightGBM PR-AUC drop to 0.3893 and 0.4030); whereas an end-to-end multimodal fine-tuning architecture (Transformer E2E FineTune) utilizing layer-wise parameter freezing and differential learning rates reverses text negative transfer, achieving the highest AUROC of 0.8288 +/- 0.0110, PR-AUC of 0.4373 +/- 0.0310, and F1-Score of 0.4757 +/- 0.0196. Operational indicators supply independent risk signals, laying an engineering foundation for high-utility clinical decision support tools.

0.37

Video-Based Sexual Harassment Detection Using Fine-Tuned Video Transformers

cs.CV ·2026-10-11 ·Jubayer- Al- Mahmud, Md Shamimul Islam, Md Nur Hossain
similarity 0.55
Abstract

Sexual harassment represents a pervasive societal challenge, with a substantial proportion of incidents remaining unreported due to insufficient evidence and delayed intervention mechanisms. Smart surveillance systems capable of detecting such incidents in real-time could assist law enforcement and serve as a deterrent. However, video-based harassment detection poses significant challenges, including variations in clothing, illumina- tion, partial occlusions, low resolution, and diverse camera view- points. Despite its social importance, this problem has received limited research attention, primarily due to the scarcity of large- scale annotated video datasets. To address this gap, we extend the Sexual Harassment Video (SHV) dataset to 600 short video clips sourced from YouTube and annotated into harassment and non-harassment categories using consistent labeling guidelines. We fine-tune three state-of-the-art video transformer models, VideoMAE, ViViT, and TimeSformer, pretrained on Kinetics- 400, for binary harassment classification. Experimental results show that all three models achieve competitive classification performance, with TimeSformer attaining the highest test accu- racy of 92.27%, outperforming VideoMAE 91.71% and ViViT 91.16% on the extended SHV test set. Our analysis reveals that performance is notably influenced by dataset size, video quality, frame sampling strategy, and model architecture. This work presents a comprehensive evaluation of modern video transformers for this sensitive real-world task.

0.30

An Integrated Video-AI Platform for Action-Level Microanastomosis Training and Performance Feedback

cs.CV ·2026-09-06 ·Yan Meng, Daniel A. Donoho
similarity 0.55
Abstract

Developing microanastomosis skill requires repeated practice with timely, action-specific feedback, yet expert review of lengthy microscope videos does not scale to frequent or distributed training. We present an integrated video-AI platform that turns a complete simulated procedure into inspectable, interactive feedback through three connected modules. First, a proposed transformer segments the video into six surgical actions. Second, object detection and tracking localize instrument tips within each action; the resulting kinematic features and action statistics drive supervised classification of five NOMAT-aligned performance dimensions. Third, a grounded large language model (LLM) uses these structured outputs to answer user questions about the current scene, actions, motion, and predicted performance through a unified interface. In a two-site study, 17 participants completed 72 procedures comprising 576 suture placements. The action-segmentation module achieved 87.66\% accuracy and 82.86\% F1, increasing to 93.62\% and 88.32\% after workflow-aware refinement. The five performance classifiers achieved 76.0\% mean accuracy, with Cohen's $κ$ from 0.63 to 0.93. Although the language interface and educational benefit require prospective evaluation, these results establish the technical basis for an expert-supervised platform that can shorten review, expose the evidence behind performance estimates, and support scalable formative microsurgical training.

0.15

From Triage to Discharge: A Survey of NLP Tasks, Methods, and Open Challenges in the Emergency Department

cs.CL ·2026-08-23 ·Dipankar Srirag, Aditya Joshi, Salil Kanhere, Padmanesan Narasimhan
top venuesurvey similarity 0.55
Abstract · Accepted to the EMNLP 2026 Main Conference; camera-ready version

Emergency departments (EDs) operate under time pressure, generating multimodal data such as clinical conversations, triage notes, and discharge documents. Recent advances in natural language processing (NLP), particularly pretrained transformers and large language models, have created new opportunities to support language and time-intensive stages of emergency care. Yet existing surveys map clinical NLP across the broader hospital workflow or focus on specific tasks. This survey analyses 46 papers spanning the three phases of ED: triage, diagnosis, and disposition, covering tasks such as triage classification, clinical summarisation, automatic diagnosis, report generation, and discharge documentation. We examine modelling paradigms, evaluation practices, and emerging benchmarks and shared tasks. Across tasks, we identify common trends, including a shift from task-specific neural architectures to pretrained language models, growing interest in interactive clinical systems, and increasing attention to clinically grounded evaluation. Finally, we detail open challenges such as limited generalisability, noisy clinical inputs, and workflow constraints that inform future ED-NLP research.

0.60

Video Based Assessment of Surgical Skills Using Frozen Pretrained Video Foundation Models

eess.IV ·2026-09-17 ·Sangrock Lee, FNU Rahul, Suvranu De
publishedbenchmark similarity 0.55
Abstract · Accepted for publication in npj Digital Medicine

Automated video-based surgical skill assessment has advanced rapidly, yet rigorous evaluation of continuous standardized score prediction under participant-level generalization to unseen trainees remains limited. We introduce VBA-Net+, a video-only framework for Fundamentals of Laparoscopic Surgery (FLS) score regression and pass-fail classification using pretrained video foundation models as frozen feature extractors. We evaluate two FLS datasets, suturing and pattern cutting, using VideoPrism, V-JEPA2, and VideoMAE v2, with a frame-level SimCLR baseline. A lightweight fully convolutional head is trained on embeddings offline and evaluated using participant-level leave-one-user-out (LOUO) cross-validation within the standardized assessment protocol. For continuous score prediction, the best representation achieves $R^2$=0.6367 for suturing and 0.9261 for pattern cutting. For pass-fail classification at official FLS thresholds, area under the receiver operating characteristic curve (AUC) reaches 0.9073 and 0.9906, respectively. Frozen video-encoder pipelines generally outperformed the frame-level SimCLR pipeline, particularly for suturing, providing a benchmark for video-only FLS assessment.