CS Paper Radar

Effects of Quantum Noise and Source Blurring on Dark-Field Signal Retrieval in X-ray Speckle-Based Imaging

Hunwoo Lee, Jingcheng Yuan, Mini Das

eess.IV physics.opticseess.SPphysics.ins-detphysics.med-ph ·submitted 2026-08-25 16:49 UTC · v1
unusual

Abstract

X-ray speckle-based dark-field imaging offers high sensitivity to sub-pixel structural features, yet its quantitative reliability in clinical and preclinical settings remains constrained by low photon flux and finite focal spot sizes. However, how hardware-induced noise and source blurring propagate through retrieval algorithms to degrade signal integrity is not fully understood. Here, we systematically evaluate algorithm robustness quantified by signal linearity, sensitivity, and bias under photon starvation and source blurring across two mathematically distinct frameworks: differential-based intrinsic tracking (Low-Coherence System, LCS) and patch-wise explicit tracking (X-ray Speckle-Tracking Speckle-Vector-Tracking, XST-XSVT). Our experimental results demonstrate that input speckle pattern distortions propagate through retrieval algorithms in fundamentally different ways depending on algorithm architecture. As an example, using our setup, under severe photon starvation, derivative noise amplification in LCS causes its dark-field signal linearity and sensitivity to drop precipitously, while sharply elevating baseline bias. In contrast, XST-XSVT restricts these losses for sensitivity while maintaining a stable baseline, as its patch-wise variance calculation inherently suppresses stochastic noise. Similarly, under blur-limited conditions , source blurring washes out the speckle pattern, directly reducing dark-field sensitivity for both LCS and XST-XSVT. This characterization establishes operational boundaries for low-power and low-coherence X-ray systems, guiding algorithm selection and framework optimization to realize quantitative dark-field imaging in preclinical and clinical applications.

Comment
18 pages 9 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Denoise X: Self-Supervised U-Net for Quantum Mottle Suppression in Chest Radiography

cs.CV ·2026-10-13 ·Parth Giramkar, Aryan Patle, Vanita Kshirsagar
similarity 0.54
Abstract

Deep learning for medical image restoration is often constrained by the need for paired training data. Acquiring perfectly registered clean-noisy radiographs in vivo is impractical due to patient motion and radiation-dose limits. To address this, we employ a self-supervised Noise2Noise paradigm that trains on independently corrupted observations without paired clean images. We propose Denoise X, a lightweight self-supervised U-Net model (7.79M parameters) for suppressing quantum mottle and electronic readout noise in low-dose chest radiographs. It is trained on the NIH ChestX-ray14 dataset (112,120 images) using a stochastic Poisson-Gaussian noise simulator. Zero-shot evaluation on the unseen Montgomery County dataset achieved a PSNR of 36.09 dB and SSIM of 0.8806, outperforming the Bilateral filter while preserving high-frequency anatomical details. Using patch-wise inference, Denoise X processes native-resolution chest radiographs in ~2.2 s per image on a Tesla P100 GPU. Cross-domain evaluation on the Shenzhen dataset achieved 36.44 dB PSNR and 0.9099 SSIM, showing strong generalization. For resource-constrained deployment, the model was converted into a 31.16 MB ONNX model for efficient CPU inference on non-DICOM images.

0.26

Mask2Restore: Self-Supervised Ultrasound Despeckling via Inpainting

eess.IV cs.CV ·2026-09-26 ·Xuesong Li, Yingtai Xu, Zhongliang Jiang, Nassir Navab, Yuan Bi
similarity 0.54
Abstract

Medical ultrasound (US) is inherently degraded by speckle, a granular interference pattern that is often treated as a complex form of noise in image restoration. However, unlike random noise, US speckle originates from coherent scattering within tissue and is therefore highly spatially dependent and deterministic under fixed acquisition conditions, making US speckle suppression fundamentally different from natural image denoising. Because speckle-free US targets are unavailable in practice, self-supervised denoising is necessary. Blind-spot networks (BSN) are the dominant self-supervised paradigm for natural images, but their pixel-wise masking strategy assumes spatially independent noise, an assumption poorly matched to US speckle, which is spatially correlated over multiple pixels rather than pixel-wise independent. To address this mismatch, we propose Mask2Restore, a self-supervised US despeckling framework that reformulates despeckling as contextual inpainting with block-wise masking on single noisy images. Unlike pixel-wise BSN masking, block-wise masking addresses this multi-pixel speckle correlation by removing locally correlated speckle neighborhoods and shifting the reconstruction cues used by the network from adjacent speckle correlations to broader anatomical context. We further introduce cross-resolution context regularization (CRCR), which suppresses residual speckle bias by enforcing consistency across multi-resolution predictions. Experiments on simulated and in vivo carotid US, unseen fine-structure cases, and downstream cardiac segmentation demonstrate improved speckle-detail trade-offs, better preservation of fine anatomical structures, and practical value for subsequent image analysis.

0.20

QCxSimulation: Scatter-Aware X-Ray Projection Radiography via Discrete-Time Quantum Walks

cs.ET quant-ph ·2026-09-07 ·Anja Heim, Theobald Fuchs, Thomas Lang, Dimitri Prjamkov, Kilian Dremel +2 more
similarity 0.53
Abstract · 17 pages, 8 figures, 1 table

X-ray projection radiography is a non-invasive imaging technique used in medical diagnostics and industrial inspection. The simulation of X-ray projections is commonly used to optimise acquisition protocols and improve image quality before performing costly scans. Classical photon transport simulations that include realistic X-ray scattering physics are computationally expensive because they require the sampling of a large number of distinct scattering paths. This limits the practical exploration of parameter spaces such as beam energy. Quantum computing offers the potential to solve high-dimensional problems faster by making use of quantum properties such as superposition. This work introduces a discrete-time quantum walk algorithm that simulates the transport of X-ray photons through heterogeneous volumes. It approximates the physics of X-ray projection radiography, including processes such as photoelectric absorption and higher-order scattering, including Compton and Rayleigh scattering. The quantum walk encodes all admissible photon paths into a single quantum state, enabling all scattering histories to be propagated simultaneously via the superposition principle. This quantum state representation enables flexible readout of various imaging modalities, including the primary, i.e., unscattered, image, or images exclusively containing Rayleigh and Compton scattering of specified orders. A quantitative comparison with classically computed reference simulations shows that the proposed quantum walk accurately reproduces radiographic projections, given the limitations of the underlying physical model. These results indicate that quantum circuits for X-ray transport can produce accurate radiographic images and imply that, as quantum hardware scales up, these algorithms could outperform classical Monte Carlo-based approaches in large-scale, scatter-aware virtual imaging studies.

0.31

Spatiotemporal Flux Probing for Single-Photon Videography

cs.CV ·2026-09-18 ·Jerry Yan, Matteo Forlivesi, Bowen Tan, Andrew Xie, Siddharth Somasundaram +1 more
top venuecode/datahot direction similarity 0.52
Abstract · ECCV 2026, Project page: https://jerukan.github.io/spt-flux-probing

We address the problem of recovering high-speed videos from dynamic scenes under extreme photon sparsity. Existing methods rely on aggregating photon detections in local spatiotemporal windows to improve signal-to-noise ratio; however, this local grouping discards global structure and fails in low-light regimes where photon detections are sparse in space and time. In this work, we show that the information needed to recover both motion and illumination is encoded in correlations over the full space-time pattern of photon arrivals. Building on this insight, we develop a spatiotemporal flux probing theory and an algorithm that estimates the Fourier coefficients of the underlying intensity directly from the photon stream. We demonstrate that our approach (1) recovers fast motion and temporal illumination dynamics with substantially fewer photons than prior methods, (2) enables velocity-selective videography that automatically refocuses video onto specific detected motions, and (3) generalizes across sensing modalities including single-photon, event, and spike cameras.

0.62

Differentiable Inverse Rendering Recovers Intrinsic Properties from Intravascular Optical Coherence Tomography

cs.CV eess.IVphysics.med-phphysics.optics ·2026-11-09 ·Ajay Manicka, Karim Kadry, Sebastian Ruiz-Lopera, Maryam Alsharqi, Sanjana Arji +5 more
similarity 0.52
Abstract · 27 Pages, 6 Figures, Under Review

Medical images encode intrinsic tissue properties that indicate disease progression, yet these properties remain entangled with the system-dependent physics of image formation. Differentiable inverse rendering asks whether they are recoverable by inverting the imaging system's forward physics rather than through post-hoc correction. We address this in optical coherence tomography (OCT), focusing on the optical attenuation coefficient, a per-pixel marker of pathology and cellular composition. Conventional recovery relies on closed-form inversions limited to simplified light-tissue models, or learned methods coupled to specific imaging configurations. We instead recover per-pixel attenuation from a single OCT image by gradient descent through a differentiable physics-based forward model. We verified the method against analytical solutions, validated it on five in vitro phantoms, and applied it without modification to 29{,}269 clinical intravascular OCT images from 128 patients. The inversion needs no training data or segmentations and is portable across platforms and retrospective archives. Replacing the forward model or recovering another optical parameter leaves the optimization procedure unchanged. We demonstrate per-pixel recovery is tractable because gradient information scales to this high-dimensional problem, where gradient-free methods become intractable. Our work supports quantitative tissue characterization from OCT images and provides a framework for extension across imaging modalities and organ systems.

0.26

High-Flux Count-Free Single-Photon 3D Cameras

cs.CV ·2026-08-18 ·Kaustubh Sadekar, Vivek K Goyal, David Maier, Atul Ingle
published similarity 0.52
Abstract · Presented at IEEE ICCP 2026 (Best Paper Award Winner). To appear in IEEE Transactions on Pattern Analysis and Machine Intelligence (TPAMI)

Single-photon cameras based on single-photon avalanche diode (SPAD) technology are gaining popularity for 3D sensing, thanks to their extreme sensitivity and time resolution. There are two key challenges with single-photon cameras that limit their widespread use: (i) they suffer from non-linear distortions called ''pile-up'' when operated in high-photon-flux conditions, and (ii) they generate a large volume of raw photon data, creating a severe data bottleneck at each sensor pixel. In this work, we show that while compressive capture techniques successfully mitigate data transfer challenges, they exacerbate the effects of dead-time distortion because they fail to retain sufficient information about the photon detection history to allow post-processing pile-up correction via existing methods. We propose a new computational-imaging method that combines free-running capture with an analysis-by-synthesis software pipeline to mitigate pile-up distortions. Our results with hardware emulations and full-scene and single-pixel simulations show that our method can reliably capture scene distance and reflectance over a wide range of illumination conditions. Our work will enable high-resolution SPAD cameras that are severely bandwidth-constrained to operate in real-world high-flux scenarios.

0.41

Severity-Channel Conditioning: An Injection-Level Study for Consumer-Device Deblurring

eess.IV cs.AIcs.CVcs.LG+1 ·2026-10-17 ·Abdullah Al Shafi, Kazi Saeed Alam, Sumaiya Rahim Suma, Sk. Imran Hossain
benchmarkcode/data similarity 0.51
Abstract · 17 pages (12 main + 5 supplementary), 7 figures, 14 tables. Code: https://github.com/C-loud-Nine/Severity-Channel-Conditioning

Motion-deblurring models lose substantial accuracy when transferred from professional cameras to smartphone-derived imagery. This paper studies whether a severity descriptor, partly derived from the paired sharp target, helps adaptation on the iPhoneBlur consumer-device benchmark. Under a shared update budget, input concatenation of a severity map is compared with global feature modulation by capture metadata, spatial feature modulation by the severity map, and a tier-contrastive output objective, together with an unconditioned spectral-loss control, all fine-tuned from the same domain-adapted latent-diffusion baseline. The primary experiment is an oracle diagnostic: target-derived information is supplied at inference. For the evaluated model pair, input concatenation improves overall peak signal-to-noise ratio from 31.23 to 31.30 dB, whereas feature modulation, the contrastive objective, and the spectral-loss control do not exceed the baseline. The gain is positive on 87.2% of test images and on 14 of 15 held-out source videos; this video-level analysis describes the evaluated checkpoint pair and does not establish robustness to retraining, and three training seeds are reported separately. The input-level gain recurs on a transformer backbone. In one exploratory run, zeroing the channel at inference retains most of the gain in peak signal-to-noise ratio but lowers structural similarity below the baseline. A normalized-step diagnostic does not support the expected larger-gradient explanation. The results characterize the evaluated configurations and do not establish injection location as the sole cause, a spatial-locality mechanism, or a reliable deployment advantage.

0.36

Differentiable Jitter Correction using Deep Learning-based Image Quality Metric for Phase-Contrast Micro-CT

cs.CV ·2026-08-27 ·Junan Chen, Yiting Jia, Joscha Maier, Dominik John, Sami Wirtensohn +4 more
similarity 0.51
Abstract

This paper proposes a fully differentiable jitter correction method for X-ray phase-contrast micro computed tomography using a deep learning-based image quality metric that estimates and compensates per-projection rigid jitter directly from the acquired projection data, without a pre-scan motion-free reference. The approach builds on a gradient-based auto-focus strategy adapted to parallel-beam geometry. A set of candidate objective functions is benchmarked in a controlled study, and the sensitivity of the visual information fidelity (VIF) metric to the jitter artifact is verified with the target phase-contrast data. To operate without a clean reference, a compact 3D convolutional neural network is trained to predict the VIF score from a single corrupted volume. A spatially selective total variation penalty applied exclusively to the image background is introduced to penalize spurious high-frequency structures that otherwise emerge during optimization. Experiments on biological specimens acquired at different synchrotron beamlines are conducted. Evaluation uses jitter motion applied to simulated and experimentally acquired projection data. The result confirms that the integrated pipeline reliably recovers fine structural detail lost due to jitter, with generalization demonstrated across morphologically distinct samples.

0.21