CS Paper Radar

Denoise X: Self-Supervised U-Net for Quantum Mottle Suppression in Chest Radiography

Parth Giramkar, Aryan Patle, Vanita Kshirsagar

cs.CV ·submitted 2026-10-13 15:29 UTC · v1

Abstract

Deep learning for medical image restoration is often constrained by the need for paired training data. Acquiring perfectly registered clean-noisy radiographs in vivo is impractical due to patient motion and radiation-dose limits. To address this, we employ a self-supervised Noise2Noise paradigm that trains on independently corrupted observations without paired clean images. We propose Denoise X, a lightweight self-supervised U-Net model (7.79M parameters) for suppressing quantum mottle and electronic readout noise in low-dose chest radiographs. It is trained on the NIH ChestX-ray14 dataset (112,120 images) using a stochastic Poisson-Gaussian noise simulator. Zero-shot evaluation on the unseen Montgomery County dataset achieved a PSNR of 36.09 dB and SSIM of 0.8806, outperforming the Bilateral filter while preserving high-frequency anatomical details. Using patch-wise inference, Denoise X processes native-resolution chest radiographs in ~2.2 s per image on a Tesla P100 GPU. Cross-domain evaluation on the Shenzhen dataset achieved 36.44 dB PSNR and 0.9099 SSIM, showing strong generalization. For resource-constrained deployment, the model was converted into a 31.16 MB ONNX model for efficient CPU inference on non-DICOM images.

Closest papers

Nearest neighbours by meaning across the whole index.

Physics-Driven Independent Pair Generation for Iterative Self-Supervised Low-Dose CT Denoising

cs.CV ·2026-09-01 ·Xianlei Han, Shaoyu Wang, Jiancheng Fang, Weiwen Wu, Qiegen Liu
similarity 0.68
Abstract · 10 pages, 11 figures, 3 tables. Includes a 1-page appendix. Submitted to IEEE Transactions on Circuits and Systems for Video Technology

Low-dose computed tomography (LDCT) measurements contain mixed Poisson-Gaussian noise. However, most self-supervised methods rely on generic image statistics and do not explicitly model this noise, which may limit their ability to effectively suppress realistic LDCT noise. To address this issue, we propose a physics-driven framework with cross-domain iteration for self-supervised LDCT denoising. The proposed framework proceeds in three main steps. First, a learned sinogram prior and the LDCT noise model guide posterior inference of photon counts, enabling separation of the Poisson and Gaussian components. Second, the separated Poisson and Gaussian components are respectively processed by binomial thinning and Gaussian data thinning to construct two branches, and residual scaling matches each branch's noise level to that of the observation, yielding a training pair with approximately independent noise realizations from one low-dose measurement. Finally, the pair is used to train an image-domain network whose forward-projected outputs update the prior. Through cross-domain iteration, the prior and the training pair are progressively refined while maintaining consistency with CT acquisition physics. Experiments on simulated data from AAPM, LIDC-IDRI, and LoDoPaB-CT and on real LDCT data show consistent gains over the evaluated self-supervised baselines across dose levels, with performance comparable to the evaluated supervised baseline.

0.25

DuSS-PET: Self-Supervised Low-Dose PET Reconstruction Using Pseudo-Dual-Domain Consistency Without Paired Data

cs.CV ·2026-11-08 ·Shuijin Lin, Yuzhu He, Yongbo Wang, Jianhua Ma, Fan Wang
top venuecode/data similarity 0.66
Abstract · Author accepted manuscript. Published in IEEE Transactions on Radiation and Plasma Medical Sciences (Early Access, 2026)

Positron emission tomography (PET) is pivotal in medicine and healthcare, but requires high radiation doses for quality imaging. Although deep learning has shown promise for low-dose PET reconstruction/enhancement, existing methods primarily rely on fully supervised learning, which requires paired low- and full-dose scans that are clinically impractical to obtain. To overcome this fundamental limitation, we propose DuSS-PET, a novel self-supervised PET reconstruction framework that operates without any paired low- and full-dose data. Our method is built upon a computational Noisier2Noise (Nr2N) paradigm, featuring a Bernoulli corruption strategy that serves as an image-space approximation to emulate low-count noise patterns in image-derived pseudo-sinogram representations. The DuSS-PET framework integrates three core components: an adaptive Swin transformer for pseudo-sinogram restoration, a plug-and-play module for image enhancement, and a consistency-constrained SSL strategy that enforces agreement between the pseudo-sinogram and image representations. Extensive experiments on multi-center datasets demonstrate that DuSS-PET achieves superior reconstruction performance, outperforming state-of-the-art SSL methods and achieving comparable or even better results than fully supervised approaches across various dose levels. In particular, it exhibits exceptional generalization across different scanner vendors. This work is among the first self-supervised low-dose PET reconstruction framework that enforces consistency between reconstructed images and pseudo-sinograms, where the pseudo-sinogram generated in the image space serves as a solid computational consistency constraint for enhanced imaging without full-dose training scans. The source code will be publicly available at https://github.com/ladderlab-xjtu/DuSS-PET.

0.48

Noise2Match: Self-Supervised Low-Dose CT Denoising via Adaptive Inter-Slice Matching

cs.CV ·2026-10-13 ·Langrui Zhou, Guang Li, Xinyu Huang, Ziteng Zhou, Zuyang Huang +3 more
top venue similarity 0.64
Abstract

With the rapid development of deep learning, supervised convolutional neural network methods have greatly improved the performance of low-dose computed tomography (CT) denoising. However, they require paired noisy-clean training data, which is difficult to obtain in practice. Some classic self-supervised denoising methods rely on the assumption of pixel-wise independent noise, making them ineffective for correlated noise in low-dose CT (LDCT) images. Considering the high similarity and weaker noise correlation between adjacent CT slices, several recently proposed self-supervised methods use adjacent LDCT slices for training. Nevertheless, these approaches fail to effectively account for the non-rigid misalignment between slices caused by anatomical variation, hindering them from satisfying the equal-mean condition required by the classic Noise2Noise framework. In this paper, we propose Noise2Match, a self-supervised LDCT denoising method based on adaptive inter-slice matching. Noise2Match introduces an inter-slice matching network to model the label transition process between adjacent slices, and then applies correction to the denoiser's outputs to better satisfy the equal-mean condition. We theoretically prove that, under idealized conditions, training Noise2Match using adjacent LDCT slices is equivalent to supervised training with paired noisy-clean images. We further find that Noise2Match can also effectively perform low-dose conebeam CT (CBCT) denoising, which could be attributed to its correction operation that reduces inter-slice noise correlation. To the best of our knowledge, Noise2Match is the first effective image-domain self-supervised method for low-dose CBCT. Extensive experiments demonstrate that Noise2Match outperforms existing image-domain selfsupervised methods, offering broader applicability and higher practical value.

0.33

One Step Is Optimal: Unconditional Rectified Flows as Noise2Noise Denoisers for Low-Dose CT

cs.CV ·2026-09-15 ·Timothy Sereda, Debesh Jha
benchmark similarity 0.63
Abstract · 15 pages, 3 figures

We study rectified flows for denoising without clean training targets. For an unconditional rectified flow trained on Noise2Noise pairs, the optimal velocity field yields the minimum mean squared error (MMSE) denoiser in one step. In a jointly Gaussian model, we show that integrating the flow before applying its denoising readout increases error with integration time. The flow transports between noisy distributions, so its endpoint is not a clean-image estimate. Experiments on low-dose CT and Gaussian-corrupted natural images follow this pattern: one-step flow performs similarly to direct regression on the same pairs, whereas additional Euler steps reduce PSNR. A direct regressor using spatially separated, similar patches gives our best label-free CT result, a $1.99$\,dB gain over the noisy input. We report these results in CTDenoiser, a benchmark covering five architectures, supervised and self-supervised training, and two per-image methods. Supervised CNNs gain about $4$\,dB, while label-free performance depends strongly on how training pairs account for correlated CT noise. A channelized Hotelling observer also shows that fidelity gains need not improve lesion detectability: detectability falls at $160$\,HU despite higher PSNR and SSIM, while changes at $40$--$80$\,HU are small. Code, model definitions, and data-loading utilities will be released publicly; the repository link is withheld for anonymous review.

0.31

Anatomy-Decomposed Chest Computed Tomography (CT) Projections as Scalable Supervision for Bone Suppression in Chest Radiographs

cs.CV ·2026-09-21 ·Mrunmay Angaitkar, Piyush Kumar, Aarjav Satia, Pranav Rao, Ashish Mittal +2 more
code/data similarity 0.63
Abstract

Bone overlap can obscure abnormalities in chest radiographs, while scarce paired training data limit supervised bone suppression. We address this challenge with a digitally reconstructed radiograph (DRR) framework that converts chest computed tomography (CT) into paired supervision for component suppression. A novel bone segmentation algorithm enables CT decomposition into bone, non-lung soft-tissue, and lung components, which are projected separately. Their weighted combination yields synthetic radiographs with pixel-registered component images that sum exactly to the full DRR. Models trained on these data suppress bone or lung components by predicting the target component and recovering the remainder by subtraction, transferring to real radiographs without real paired training data. As an extension, their outputs on real radiographs provide target domains for unpaired, component-wise DRR translation, reducing the appearance gap while retaining anatomical details. Across multiple public datasets, downstream detection experiments demonstrate the utility of bone suppression, with gains concentrated on abnormalities with substantial bone overlap. Compared with open-source DRR engines applied to the same CTs, our unmodified DRRs achieve comparable realism and preservation of label-relevant anatomy, while translated DRRs achieve the best Fréchet inception distance (FID), lung-field sharpness, and agreement with source-CT anatomy among the evaluated methods. Models and inference code: https://huggingface.co/qureaiorg/bone-suppression ; Translated projections: https://huggingface.co/datasets/qureaiorg/ct2xr-projections.

0.35

Matching Particle-Arrival Rates for Low-Count Image Denoising

eess.IV cs.CV ·2026-10-23 ·Huazhen Liu, Zipei Yan, Jizhou Li
similarity 0.62
Abstract

Low-count imaging arises when limited illumination or dose yields only a few detected particles in microscopy, such as photons or electrons, causing measurements to be dominated by signal-dependent Poisson shot noise. Supervised denoisers typically require paired clean and noisy observations, whereas many self-supervised approaches exploit spatial or temporal redundancy without directly estimating the underlying particle-arrival process. We introduce PARM, a self-supervised denoising framework based on particle-arrival-rate matching. By modeling particle accumulation over exposure as a Poisson counting process, PARM identifies the conditional particle-arrival-rate field with the posterior mean of the latent clean rate. Poisson thinning then splits each observation into complementary lower-exposure views that provide self-supervised rate targets for one another. In implementation, the network estimates the normalized spatial allocation of the conditional rate, while the observed total count determines its global particle mass. Experiments on synthetic data, natural-video sequences corrupted with Poisson noise, and real low-dose electron microscopy demonstrate leading or competitive performance while effectively preserving fine structures. PARM therefore provides a statistically grounded approach to low-count image denoising when clean references are unavailable.

0.19

Coarse-to-Fine Diffusion with Residual Prior for Low-Dose CT Denoising

eess.IV ·2026-09-30 ·Ping Wu, Pengcheng Zheng, Jiahao Zhang, Bohao Chen, Yazhou Ren +1 more
similarity 0.61
Abstract · 10 pages

Low-dose CT (LDCT) reduces radiation exposure but often introduces severe noise and streak artifacts that obscure subtle anatomical structures. Existing diffusion-based denoising methods commonly rely on implicit assumptions about the noise distribution, which may not hold in practical LDCT scenarios and can degrade denoising performance. To address this limitation, we propose a Residual-Guided Diffusion framework that effectively incorporates an explicit difference prior to inform the diffusion process of noise distribution. The difference prior is computed as the residual between the LDCT image and a coarse clean estimate, constraining diffusion sampling to a plausible residual space. We further adopt a coarse-to-fine strategy in which a pre-trained RED-CNN provides the coarse estimate to anchor global anatomy, and the diffusion model refines the remaining details under the prior guidance. For efficiency, we employ accelerated sampling with 20 steps at inference. Experiments on three representative datasets demonstrate that our approach outperforms existing methods in both quantitative and qualitative performance measures.

0.14

Beyond MSE: Rician Likelihood Denoising for Self-Supervised Cardiac $T2$ and $T1ρ$ MRI

eess.IV cs.CV ·2026-09-24 ·Nicholas A. Jacobs, Jason Mendes, Ravi Ranjan, Edward DiBella, Shireen Elhabian
similarity 0.61
Abstract · Made minor spelling and punctuation corrections

Magnetic resonance imaging involves an inherent trade-off among spatial resolution, acquisition time, and noise. This trade-off contributes to long scan times and high cost. Deep learning has improved image denoising, but cardiac MRI remains difficult because high-resolution, rapid acquisitions generally lack corresponding low-noise ground truth. Self-supervised denoising offers a potential solution by learning from noisy image pairs or even single noisy acquisitions. However, we show that Noise2Void-style blind-spot denoising, which uses a mean squared error (MSE) loss and assumes zero-mean, independent and identically distributed (i.i.d.) noise, is poorly suited to MR magnitude images. When applied to short-axis $T2$-weighted and $T1ρ$-weighted cardiac MRI with synthetic Rician noise, it produces biased denoised images and biased parametric maps of $T2$ and $T1ρ$. To address this limitation, we formulate self-supervised denoising as maximum likelihood estimation under a known Rician noise model. This yields unbiased denoisers that are competitive with supervised baselines.

0.22