CS Paper Radar

Matching Particle-Arrival Rates for Low-Count Image Denoising

Huazhen Liu, Zipei Yan, Jizhou Li

eess.IV cs.CV ·submitted 2026-10-23 15:12 UTC · v1

Abstract

Low-count imaging arises when limited illumination or dose yields only a few detected particles in microscopy, such as photons or electrons, causing measurements to be dominated by signal-dependent Poisson shot noise. Supervised denoisers typically require paired clean and noisy observations, whereas many self-supervised approaches exploit spatial or temporal redundancy without directly estimating the underlying particle-arrival process. We introduce PARM, a self-supervised denoising framework based on particle-arrival-rate matching. By modeling particle accumulation over exposure as a Poisson counting process, PARM identifies the conditional particle-arrival-rate field with the posterior mean of the latent clean rate. Poisson thinning then splits each observation into complementary lower-exposure views that provide self-supervised rate targets for one another. In implementation, the network estimates the normalized spatial allocation of the conditional rate, while the observed total count determines its global particle mass. Experiments on synthetic data, natural-video sequences corrupted with Poisson noise, and real low-dose electron microscopy demonstrate leading or competitive performance while effectively preserving fine structures. PARM therefore provides a statistically grounded approach to low-count image denoising when clean references are unavailable.

Closest papers

Nearest neighbours by meaning across the whole index.

Physics-Driven Independent Pair Generation for Iterative Self-Supervised Low-Dose CT Denoising

cs.CV ·2026-09-01 ·Xianlei Han, Shaoyu Wang, Jiancheng Fang, Weiwen Wu, Qiegen Liu
similarity 0.68
Abstract · 10 pages, 11 figures, 3 tables. Includes a 1-page appendix. Submitted to IEEE Transactions on Circuits and Systems for Video Technology

Low-dose computed tomography (LDCT) measurements contain mixed Poisson-Gaussian noise. However, most self-supervised methods rely on generic image statistics and do not explicitly model this noise, which may limit their ability to effectively suppress realistic LDCT noise. To address this issue, we propose a physics-driven framework with cross-domain iteration for self-supervised LDCT denoising. The proposed framework proceeds in three main steps. First, a learned sinogram prior and the LDCT noise model guide posterior inference of photon counts, enabling separation of the Poisson and Gaussian components. Second, the separated Poisson and Gaussian components are respectively processed by binomial thinning and Gaussian data thinning to construct two branches, and residual scaling matches each branch's noise level to that of the observation, yielding a training pair with approximately independent noise realizations from one low-dose measurement. Finally, the pair is used to train an image-domain network whose forward-projected outputs update the prior. Through cross-domain iteration, the prior and the training pair are progressively refined while maintaining consistency with CT acquisition physics. Experiments on simulated data from AAPM, LIDC-IDRI, and LoDoPaB-CT and on real LDCT data show consistent gains over the evaluated self-supervised baselines across dose levels, with performance comparable to the evaluated supervised baseline.

0.25

Denoise X: Self-Supervised U-Net for Quantum Mottle Suppression in Chest Radiography

cs.CV ·2026-10-13 ·Parth Giramkar, Aryan Patle, Vanita Kshirsagar
similarity 0.62
Abstract

Deep learning for medical image restoration is often constrained by the need for paired training data. Acquiring perfectly registered clean-noisy radiographs in vivo is impractical due to patient motion and radiation-dose limits. To address this, we employ a self-supervised Noise2Noise paradigm that trains on independently corrupted observations without paired clean images. We propose Denoise X, a lightweight self-supervised U-Net model (7.79M parameters) for suppressing quantum mottle and electronic readout noise in low-dose chest radiographs. It is trained on the NIH ChestX-ray14 dataset (112,120 images) using a stochastic Poisson-Gaussian noise simulator. Zero-shot evaluation on the unseen Montgomery County dataset achieved a PSNR of 36.09 dB and SSIM of 0.8806, outperforming the Bilateral filter while preserving high-frequency anatomical details. Using patch-wise inference, Denoise X processes native-resolution chest radiographs in ~2.2 s per image on a Tesla P100 GPU. Cross-domain evaluation on the Shenzhen dataset achieved 36.44 dB PSNR and 0.9099 SSIM, showing strong generalization. For resource-constrained deployment, the model was converted into a 31.16 MB ONNX model for efficient CPU inference on non-DICOM images.

0.26

BMND: Direct Poisson Denoising by N-Dimensional Block Matching and Collaborative Filtering

cs.CV ·2026-09-28 ·Christof Duhme, Lars Schiefelbein, Florian Büther, Xiaoyi Jiang
code/dataunusual similarity 0.61
Abstract

Poisson denoising of scientific data requires methods that account for signal-dependent noise while accommodating different data dimensionalities and preserving quantitative intensity information. We present BMND, a dimension-independent extension of block matching and collaborative filtering for Gaussian and Poisson observations. Building on the two-stage structure of BM3D and BM4D, BMND processes Poisson data directly, without a variance-stabilizing transform, by combining noise-aware patch matching with propagation of signal-dependent noise variances through collaborative filtering and aggregation. A dimension-independent reference-patch traversal scheme supports arrays with an arbitrary number of axes. An optional aggregation-aware mass conservation preserves the observed total intensity after weighted overlap-add. We evaluate the framework on one-dimensional physiological signals, two-dimensional images, and three-dimensional volumes, using controlled noise experiments and measured fluorescence microscopy acquisitions. The experiments demonstrate improved reconstruction quality from noise-aware matching and Wiener filtering, while low-count phantom experiments show reduced denoising-induced intensity loss through mass conservation. The framework provides a unified, non-learning-based approach to denoising across arbitrary data dimensions and is released as an open-source library.

0.35

Learning Clean Generative Processes from Noisy Measurements

cs.CV cs.AIcs.LG ·2026-10-30 ·Fabian Kruse, Lorenzo Baldassari, Ivan Dokmanić
similarity 0.60
Abstract

We study how to learn a generative model of clean images using only noisy observations. Diffusion processes and their generalizations to non-Gaussian noise require posterior predictions at every noise level. We first show that it is possible to learn these predictions from independent noisy views using Noise2Noise regression, but only at or above the noise level of the training data. To learn the predictions below that level, needed to generate clean images, we impose consistency: a prediction should equal its expectation after continuing the sampling process. We derive conditions under which consistency uniquely determines the continuation to the clean image distribution and verify them for Poisson, binomial, Gamma, and negative-binomial measurements. Experiments on CIFAR-10, photon-counting microscopy, and synthetic aperture radar show that the required posterior predictions can be learned from noisy views alone and that the consistency relation repairs the continuation beyond the noise level of the data, which severely deteriorates without consistency.

0.20

Coarse-to-Fine Diffusion with Residual Prior for Low-Dose CT Denoising

eess.IV ·2026-09-30 ·Ping Wu, Pengcheng Zheng, Jiahao Zhang, Bohao Chen, Yazhou Ren +1 more
similarity 0.59
Abstract · 10 pages

Low-dose CT (LDCT) reduces radiation exposure but often introduces severe noise and streak artifacts that obscure subtle anatomical structures. Existing diffusion-based denoising methods commonly rely on implicit assumptions about the noise distribution, which may not hold in practical LDCT scenarios and can degrade denoising performance. To address this limitation, we propose a Residual-Guided Diffusion framework that effectively incorporates an explicit difference prior to inform the diffusion process of noise distribution. The difference prior is computed as the residual between the LDCT image and a coarse clean estimate, constraining diffusion sampling to a plausible residual space. We further adopt a coarse-to-fine strategy in which a pre-trained RED-CNN provides the coarse estimate to anchor global anatomy, and the diffusion model refines the remaining details under the prior guidance. For efficiency, we employ accelerated sampling with 20 steps at inference. Experiments on three representative datasets demonstrate that our approach outperforms existing methods in both quantitative and qualitative performance measures.

0.14

One Step Is Optimal: Unconditional Rectified Flows as Noise2Noise Denoisers for Low-Dose CT

cs.CV ·2026-09-15 ·Timothy Sereda, Debesh Jha
benchmark similarity 0.58
Abstract · 15 pages, 3 figures

We study rectified flows for denoising without clean training targets. For an unconditional rectified flow trained on Noise2Noise pairs, the optimal velocity field yields the minimum mean squared error (MMSE) denoiser in one step. In a jointly Gaussian model, we show that integrating the flow before applying its denoising readout increases error with integration time. The flow transports between noisy distributions, so its endpoint is not a clean-image estimate. Experiments on low-dose CT and Gaussian-corrupted natural images follow this pattern: one-step flow performs similarly to direct regression on the same pairs, whereas additional Euler steps reduce PSNR. A direct regressor using spatially separated, similar patches gives our best label-free CT result, a $1.99$\,dB gain over the noisy input. We report these results in CTDenoiser, a benchmark covering five architectures, supervised and self-supervised training, and two per-image methods. Supervised CNNs gain about $4$\,dB, while label-free performance depends strongly on how training pairs account for correlated CT noise. A channelized Hotelling observer also shows that fidelity gains need not improve lesion detectability: detectability falls at $160$\,HU despite higher PSNR and SSIM, while changes at $40$--$80$\,HU are small. Code, model definitions, and data-loading utilities will be released publicly; the repository link is withheld for anonymous review.

0.31

Noise2Match: Self-Supervised Low-Dose CT Denoising via Adaptive Inter-Slice Matching

cs.CV ·2026-10-13 ·Langrui Zhou, Guang Li, Xinyu Huang, Ziteng Zhou, Zuyang Huang +3 more
top venue similarity 0.56
Abstract

With the rapid development of deep learning, supervised convolutional neural network methods have greatly improved the performance of low-dose computed tomography (CT) denoising. However, they require paired noisy-clean training data, which is difficult to obtain in practice. Some classic self-supervised denoising methods rely on the assumption of pixel-wise independent noise, making them ineffective for correlated noise in low-dose CT (LDCT) images. Considering the high similarity and weaker noise correlation between adjacent CT slices, several recently proposed self-supervised methods use adjacent LDCT slices for training. Nevertheless, these approaches fail to effectively account for the non-rigid misalignment between slices caused by anatomical variation, hindering them from satisfying the equal-mean condition required by the classic Noise2Noise framework. In this paper, we propose Noise2Match, a self-supervised LDCT denoising method based on adaptive inter-slice matching. Noise2Match introduces an inter-slice matching network to model the label transition process between adjacent slices, and then applies correction to the denoiser's outputs to better satisfy the equal-mean condition. We theoretically prove that, under idealized conditions, training Noise2Match using adjacent LDCT slices is equivalent to supervised training with paired noisy-clean images. We further find that Noise2Match can also effectively perform low-dose conebeam CT (CBCT) denoising, which could be attributed to its correction operation that reduces inter-slice noise correlation. To the best of our knowledge, Noise2Match is the first effective image-domain self-supervised method for low-dose CBCT. Extensive experiments demonstrate that Noise2Match outperforms existing image-domain selfsupervised methods, offering broader applicability and higher practical value.

0.33

One Photon, Many Worlds: Posteriors and Predictions with Single-Photon Cameras

eess.IV cs.CV ·2026-10-02 ·Haejoon Lee, Mohit Gupta, Vijayakumar Bhagavatula, Aswin C. Sankaranarayanan
similarity 0.56
Abstract · 18 pages, 18 figures

Single-photon avalanche diode (SPAD) cameras operate fundamentally differently from conventional cameras due to their photon-counting nature. Each frame produces a binary image: pixels report zero if no photons arrived during exposure, and one if one or more photons arrived. Reconstructing a scene or inferring its properties from a single binary frame is difficult because many different images could produce the same measurement; thus, the inverse problem is fundamentally one-to-many. As we gather more binary measurements, the inherent uncertainty associated with the inverse problem and any associated inference diminishes. With sufficient photon counts, photon noise becomes negligible relative to the signal mean, enabling near-deterministic scene recovery and inference. This work characterizes the transition from stochastic to near-deterministic scene understanding as photon budget increases, analyzing how the stochasticity in photon arrival affects downstream inference tasks. Technically, we develop a conditional generative framework based on a Hypergeometric frame-thinning process for accumulated binary SPAD measurements. Generative models capture the one-to-many nature of photon-starved inverse problems, enabling empirical characterization of how this ambiguity diminishes with increasing measurements and its impact on downstream tasks like character recognition, QR code decoding, and facial analysis.

0.20