CS Paper Radar

OpenVeinNet: Robust Open-Set Finger Vein Verification with Dynamic Snake Convolution and Graph Learning

Sushrut Patwardhan, Raghavendra Ramachandra

cs.CV ·submitted 2026-08-26 08:25 UTC · v1
top venue

Abstract

Finger vein verification is a promising biometric modality for secure authentication because vascular patterns are internal, difficult to observe externally, and relatively resistant to presentation attacks. However, reliable verification remains challenging in open-set settings, where test identities are unseen during training and non-enrolled probes must be rejected at inference. This paper presents OpenVeinNet, a finger vein verification framework designed for cross-dataset and open-set evaluation. The proposed model combines Dynamic Snake Convolution with graph-based feature modelling. Dynamic Snake Convolution extracts local curvilinear and tubular vein structures using adaptive sampling, while the graph convolutional backbone models long-range topological relationships between vein regions. To improve the discriminative quality of the embedding space, we introduce a Centroid Angular Hybrid Loss, which jointly encourages intra-class compactness and inter-class angular separation for cosinesimilaritybased verification. Experiments are conducted on five public finger vein datasets: FV-300, MMCBNU, FV-USM, PolyU, and VERA. The method is evaluated using leaveonedatasetout training under both enrolmentbased unknownrejection and fullsubject verification protocols, and is compared with handcrafted and recent deep learning-based baselines. The results show that OpenVeinNet achieves strong cross-dataset generalisation, consistently low equal error rates, and competitive true accept rates at fixed false accept rate operating points. Ablation studies further confirm the individual and combined contributions of adaptive tubular feature extraction, graph-based relational modelling, and the proposed loss function. These findings indicate that explicitly modelling local vein geometry, global vascular relationships, and angularly compact embeddings is effective for openset finger vein verification.

Comment
preprint: Accepted for publication in IEEE Transactions on Biometrics, Behavior, and Identity Science (T-BIOM)
Journal ref
IEEE Transactions on Biometrics, Behavior, and Identity Science (Early Access), 2026
DOI
10.1109/TBIOM.2026.3728524

Closest papers

Nearest neighbours by meaning across the whole index.

FVeinSyn: Synthetic Finger Vein Image Generator

cs.CV cs.AI ·2026-08-27 ·Yifan Wang, Jie Gui, Adams Wai Kin Kong, Baosheng Yu, Changsheng Chen +4 more
top venuecode/data similarity 0.65
Abstract

A major challenge in finger vein recognition is the lack of large-scale public datasets. Existing datasets contain few identities and limited samples per finger, restricting the advancement of deep learning-based methods. To address this, we propose FVeinSyn, a large-scale controllable synthetic data generation framework for finger vein. It explicitly decouples synthesis of vascular topology and imaging appearance to mitigate the limitations caused by insufficient training samples, such as inadequate identity diversity and restricted realism. Specifically: first, a finger vein identity generator models vascular topology under physiological and geometric constraints using stochastic L-systems, producing anatomically valid and identity-distinctive vascular patterns. Then, a cascaded region-aware GAN renders the topological maps into realistic near-infrared images. Finally, an intra-class diversity generator introduces geometric and optical perturbations to simulate realistic intra-class variations. Using FVeinSyn, we generated 500,000 images (10,000 vein identities, 50 samples per identity) and conducted extensive evaluations. Results show that FVeinSyn holds significant advantages in realism, identity diversity, vascular pattern consistency, and intra-class diversity. Models trained with FVeinSyn outperform real-data-only baselines a cross eight public datasets, achieving an average accuracy improvement of 27.43\%. The code is available at: https://github.com/EvanWang98/Synthetic-Finger-Vein-Generator.

0.58

Video-Based Palm-Vein Authentication under Challenging Conditions

cs.CV ·2026-09-02 ·Xiaofeng Yan, Kechen Liu, Abhilash Venkatesh, Cathy Zhang, Xia Zhou +1 more
benchmarkdatasetcode/data similarity 0.57
Abstract

Palm-vein biometrics are increasingly used for secure, contactless authentication. Yet real-world deployment exposes them to surface noise (sweat, dirt), illumination and motion variation, and temperature-driven changes in vascular visibility, which remain underexplored for lack of data captured under such conditions. To study these effects, we introduce the Columbia University Palm-vein (CUP) dataset, to our knowledge the first public video-based palm-vein dataset. CUP records every palm under four surface conditions (a clean baseline, warm, wet, and dirty) and pairs each subject with physiological and demographic metadata. On it we benchmark twenty-one recognizers spanning static, video, and multi-frame aggregation architectures. Models that verify reliably on clean palms lose most of their accuracy on dirty ones, and the mean equal error rate (EER) roughly quadruples. We recover much of that robustness along both axes of the capture. Temporally, a consensus over the few frames the sensor already returns cancels transient corruption; spatially, a test-time matcher that adds no learned parameters fuses the global cosine with a saliency-steered region-level optimal transport that routes the comparison around corrupted regions. The full design leads on every surface of CUP in EER, TAR@FAR=0.01, and Rank-1, at 4.3M parameters and 3.1 GFLOPs, a fraction of the video models' cost. Attached to four frozen state-of-the-art backbones it cuts their mean EER by 29-37% without retraining, and on four public single-image datasets the regional matching alone still helps. A preliminary audit across ten demographic and physiological traits finds two warm-condition gaps, along body water and gender, that survive multiple-comparison correction. CUP will be released for non-commercial research use at https://github.com/MobileX-CU/CUP_v1 upon publication.

0.40

ReG-SAM: Reference Graph-Driven SAM for 2D Foundational Vessel Segmentation

cs.CV cs.AI ·2026-09-25 ·Donghang Lyu, Zichen Zhang, Oleh Dzyubachyk, Marius Staring
similarity 0.55
Abstract

Vessel segmentation in medical images is essential for many clinical tasks, ranging from diagnosis to treatment planning. However, it remains challenging due to complex vascular morphology and diverse imaging conditions. Existing deep learning methods rarely aim at building a generalizable vessel segmentor across anatomies and modalities. While the Seg- ment Anything Model (SAM) has shown promise for med- ical image segmentation, its original design does not fully exploit vascular morphology and struggles with fine-grained vascular structures, leading to suboptimal performance. In this paper, we propose ReG-SAM, a SAM-based framework tailored to 2D vessel segmentation that leverages reference graph set for enhancing vascular representations. Specifically, we introduce two modality-aware representations derived from the reference masks: graph prompt embeddings (GPEs) that encode global spatial features from graphs, and vascu- lar prototype embeddings (VPEs) that capture fine-grained modality-specific vessel characteristics from multi-scale fea- ture maps and vascular masks. Since both require vascular masks that are unavailable during inference and require robust modality-aware vascular feature representations, we construct a modality-wise vascular database and develop two reference graph-guided representation learning schemes for estimating GPEs and VPEs using samples from the database rather than ground-truth masks. Extensive experiments across 19 datasets demonstrate that ReG-SAM consistently outperforms existing baselines, even those using manual prompts, particularly on challenging thin vessels.

0.09

Personalized and Explainable Blood Pressure Estimation from PPG via Hybrid CNN--Morphological Features

cs.CV ·2026-08-11 ·Myung-Kyu Yi, Jongshill Lee, Jeyeon Lee, In Young Kim
published similarity 0.54
Abstract

Continuous cuffless blood pressure (BP) monitoring using photoplethysmography (PPG) offers a promising solution for personalized healthcare. However, existing methods have two major limitations. Handcrafted feature-based approaches rely on precise fiducial point detection and are limited to short-term analysis, while deep learning models, despite their accuracy, often operate as black boxes with limited physiological interpretability. To address these challenges, we propose a physiology-guided hybrid framework for personalized BP estimation that couples a convolutional neural network (CNN) branch capturing global and local waveform dynamics with a morphology-prior branch that explicitly encodes person-specific vascular characteristics. By embedding a morphology-based feature set that explicitly encodes individual vascular characteristics, the proposed framework enhances personalization and reduces dependence on large-scale training datasets. Evaluated on a subset of the MIMIC-III database under a subject-specific (personalized) testing protocol, the proposed personalized physiology-guided hybrid approach achieved mean absolute errors (MAEs) of 3.77 mmHg for systolic BP and 2.36 mmHg for diastolic BP, corresponding to relative improvements of 43.7% and 32.4% over a subject-specific (personalized) CNN-only baseline. SHAP-based analysis confirmed that the introduced morphology-prior features align with individual vascular characteristics, reinforcing per-subject interpretability. These findings highlight the potential of personalized, physiology-guided hybrid learning with novel morphological descriptors for accurate and explainable BP monitoring in real-world settings.

0.57

UI-VISA: U-Net Initialized Vascular Image Segmentation Architecture

cs.CV ·2026-09-01 ·Asees Kaur, Suzanne S. Sindi, Erica M. Rutter
similarity 0.53
Abstract · 9 pages, 6 figures

Accurate segmentation of vascular structures in digital subtraction angiography (DSA) images remains challenging due to the thin, elongated, and branching nature of blood vessels. Pixel-wise deep learning approaches such as U-Net achieve strong general-purpose segmentation performance but often produce fragmented or discontinuous predictions in fine vascular regions, since they do not explicitly enforce structural connectivity. Region growing algorithms preserve spatial context and topological continuity, but are highly sensitive to seed point initialization and can be computationally expensive. We propose UI-VISA (U-Net Initialized Vascular Image Segmentation Architecture), a hybrid pipeline that combines the complementary strengths of both approaches. UI-VISA uses U-Net's foreground predictions as informed seed points for a CNN-guided region growing algorithm, which then iteratively refines the segmentation by enforcing local connectivity and recovering fine vessel details that U-Net alone tends to miss or over-predict. We evaluate UI-VISA against standalone U-Net and a prior region-growing-based method (VISA) using 5-fold cross-validation on 26 DSA images. UI-VISA achieves the highest mean Dice and clDice scores across folds, and a paired Wilcoxon signed-rank test shows the improvement in clDice is statistically significant ($p=0.023$), consistent with the method's design goal of preserving vascular connectivity, while the improvement in Dice does not reach significance ($p=0.104$).

0.22

Flow Matching Meets 3D Curvilinear Structure Segmentation in Medical Imaging

cs.CV cs.LGq-bio.QM ·2026-08-20 ·Sidi Mohamed Sid'El Moctar, Nicolas Vitry, Hélène Bouvrais
published similarity 0.53
Abstract · International Workshop on Machine Learning in Medical Imaging (MLMI 2026) @ MICCAI

Segmentation of curvilinear anatomical structures in 3D medical images remains challenging due to complex topology, severe class imbalance, weak contrast, and large variations in structure morphology. While deep learning approaches for 3D curvilinear segmentation have been proposed, they are often tailored to specific anatomies or modalities, limiting generalization across clinical settings and leaving room for improvement. Recent generative models have shown the benefits of iterative prediction for structured segmentation tasks, yet diffusion-based methods suffer from computationally expensive sampling, hindering their use on high-resolution 3D volumes. We present 3D-CurvSegFlow, a flow matching-based model for 3D curvilinear structure segmentation. The model learns a continuous transformation from a simple source distribution to the target vascular representation, enabling progressive refinement of complex curvilinear geometries with efficient inference. We evaluate our method on Three public challenging datasets covering distinct anatomies and modalities: portal vein, cerebral vessel, and coronary arteries. Using a common architecture and training strategy across all tasks, our method outperforms general-purpose and vessel-specific approaches, with strong preservation of thin branches and vascular continuity. This work not only advances the state-of-the-art in 3D curvilinear segmentation but also opens new avenues for efficient, generalizable, and clinically applicable methods in medical image analysis.

0.23

Open-Set Cattle Muzzle Identification: A Leakage-Controlled Benchmark and Evaluation Protocol

cs.CV ·2026-08-22 ·Lalit BC, Dharmendra Singh Chaudhary, Shovit Nepal
benchmark similarity 0.53
Abstract

Reliable individual cattle identification supports disease surveillance, vaccination records, breeding management, and livestock insurance. Although the bovine muzzle provides a stable, non-contact biometric, existing muzzle-recognition systems largely assume a closed set of enrolled animals, limiting their practical deployment. We reformulate cattle muzzle biometrics as an open-set, gallery-based identification problem that can reject previously unseen animals and support incremental enrollment without model retraining. We introduce a leakage-controlled evaluation protocol based on identity-disjoint splits, per-fold retraining, held-out threshold calibration, verified duplicate removal, and bootstrap confidence intervals. We evaluate the framework using two contrasting embedding configurations: a hybrid CNN-ViT metric-learning model and the MegaDescriptor-L foundation model. Under oracle threshold selection, the hybrid model achieves detection-and-identification rates of 98.3%, 96.4%, and 93.6% at target false-acceptance rates of 10^(-1), 10^(-2), and 10^(-3), respectively, while MegaDescriptor-L achieves 99.3%, 98.1%, and 96.1%. However, deployable threshold calibration reveals a substantial difference between oracle and calibrated performance: the hybrid model achieves a false-acceptance rate of 1.03% at a 1% target, whereas MegaDescriptor-L reaches 2.44%. Incremental enrollment further achieves Rank-1 accuracy above 91% with a single reference image and up to 97.3% with eight reference images, without retraining the model or degrading the existing gallery. These results demonstrate that threshold calibration, leakage control, and embedding quality are critical for reliable open-set cattle identification and provide a practical evaluation framework for deployment-oriented animal biometric systems.

0.35

Revisiting Handcrafted Minutiae Detection: A Simple and Effective Open Source Baseline for Modern Fingerprint Workflows

cs.CV ·2026-10-08 ·Raffaele Cappelli
code/data similarity 0.52
Abstract

Handcrafted minutiae detection algorithms remain fundamental to biometric science and forensic practice due to their full auditability, adherence to international standards, and operational independence from training datasets or GPU hardware. However, current open-source traditional baselines are severely outdated, relying almost exclusively on legacy C/C++ codebases that lack seamless integration with modern scientific software ecosystems. To bridge this gap, the present work introduces SBMEX (Skeleton-Based Minutiae EXtraction), a fast and deterministic minutiae detection method integrated into the open source \texttt{pyfing} package. SBMEX achieves high computational throughput by employing a dual Look-Up Table architecture that replaces runtime neighborhood scanning during Crossing Number computation and skeleton tracking. Additionally, it incorporates a continuous quality scoring framework driven by tracking path length, dual ridge-valley skeleton fusion, and spatial density decay. Rigorous evaluation on NIST SD302 datasets demonstrates that SBMEX delivers feature extraction accuracy comparable to or outperforming traditional open-source baselines without fine-tuning, while achieving a drastic reduction in minutiae detection latency relative to classical Crossing Number Python implementations.

0.28