CS Paper Radar

FAN-LoRA: A Fourier-Adaptive Nonlinear Low-Rank Adaptor for Medical Foundation Model Domain Adaptation

Ziquan Liu, Zhewei Zhu, Xuyang Shi

cs.CV ·submitted 2026-08-27 02:08 UTC · v1

Abstract

The advent of vision foundation models, notably the Segment Anything Model (SAM), has catalyzed significant advancements in natural image segmentation. However, their direct transfer to medical imaging remains severely bottlenecked by profound domain gaps, such as cross-modality and cross-center shifts. Existing Parameter-Efficient Fine-Tuning (PEFT) methods facilitate the adaptation of SAM to medical domains; nevertheless, they frequently suffer from performance degradation under severe distribution shifts. This vulnerability primarily stems from the implicit entanglement of heterogeneous frequency components within a shared low-rank subspace, which directly exacerbates sub-optimal structural alignment and localized boundary blurring. To overcome this representational bottleneck, we propose the Fourier-Adaptive Nonlinear Low-Rank Adaptor (FAN-LoRA), a novel frequency-decoupled fine-tuning architecture. FAN-LoRA explicitly separates the optimization space by employing a B-spline-driven low-pass branch for global structural alignment, synergistically coupled with a discrete Fourier high-pass branch for local textural compensation. Extensive experiments across three challenging cross-modality and cross-center benchmarks demonstrate that FAN-LoRA consistently outperforms state-of-the-art PEFT baselines. Compared to the strongest competitors, our method achieves consistent improvements in average Dice scores and notable reductions in boundary errors, while maintaining a compact module size without compromising computational efficiency.

Comment
9 pages, 4 figures

Closest papers

Nearest neighbours by meaning across the whole index.

CVP-BAA: Efficiently Adapting Segment Anything Model for Medical Image Segmentation

eess.IV ·2026-10-22 ·Mei Wang, Minghui Li, Libin Lan
code/data similarity 0.65
Abstract · Submitted to CVIU, 35 pages, 8 tables, 8 figures. Our code is available at \href{https://github.com/WangMei-wm/CVP-BAA}{here}

Various task-specific medical segmentation models have demonstrated strong performance, their heavy reliance on extensive annotations and highly specialized architectures limits their versatility, scalability, and clinical applicability. Recently, adapting vision foundation models, particularly the segment anything model (SAM), has emerged as a promising alternative. However, prevalent parameter-efficient fine-tuning (PEFT) strategies, such as prompt tuning and adapter tuning, often lack an explicit mechanism to embed local structural priors into the long-range dependency modeling of vision transformers (ViT), rendering them insufficiently sensitive to fine-grained details. To address these limitations, we introduce CVP-BAA, a novel hybrid PEFT method that improves SAM's sensitivity to domain-specific textures and local details, leading to superior boundary delineation. The proposed CVP-BAA adopts two key ideas. First, it introduces a convolutional visual prompting (CVP) strategy that leverages convolutional features as structural priors, prepending them to the key and value projections within the multi-head self-attention layers of strategically selected ViT blocks. Through a dedicated prompt generation-and-injection module, this mechanism effectively bridges local spatial details with global context semantics. Second, a boundary-aware adapter (BAA) is designed as a parallel branch to the feed-forward network within the same selected blocks. By explicitly computing and amplifying high-frequency components, the BAA enhances feature representations along tissue boundaries and fine-grained lesion structures. Extensive experiments on five benchmarks across three imaging modalities demonstrate that CVP-BAA achieves superior segmentation performance, surpassing existing task-specific models and PEFT-based SAM adaptations in both quantitative metrics and qualitative results.

0.38

Multimodal Foundation Models Adaptation based on Domain-Aware Relaxed Orthogonal Subspace for Remote Sensing

cs.CV ·2026-09-12 ·Han Luo, Ruoyu Yang, Yinhe Liu, Yanfei Zhong
similarity 0.61
Abstract

Pretrained foundation models (FMs) have achieved remarkable success in computer vision, yet their high fine-tuning cost limits practical deployment. Parameter-efficient fine-tuning (PEFT) methods such as Low-Rank Adaptation (LoRA) improve efficiency by constraining updates to a predefined low-rank subspace. However, when applied to remote sensing tasks with substantial domain shifts, the fixed subspace is constructed without observing the downstream activation distribution and can therefore provide a poor coordinate system for adaptation, a phenomenon herein termed subspace mismatch. To address this issue, a unified framework is introduced, termed Domain-aware Relaxed Orthogonal Subspace adaptation (DROS), which reformulates low-rank adaptation as data-conditioned subspace learning and flexible subspace adaptation. Specifically, the weight decomposition is conditioned on second-order activation statistics estimated from the downstream training distribution, so that the initialization reflects the feature geometry actually induced by the remote-sensing data, followed by flexible geometric transformations enabled by a relaxed orthogonal parameterization. Furthermore, the framework is extended to multimodal settings (MM-DROS) by sharing transformation structures across modality-specific subspaces, facilitating efficient cross-modal interaction. Extensive experiments on multiple remote sensing benchmarks demonstrate that DROS achieves state-of-the-art performance, even surpassing full fine-tuning, without additional inference overhead.

0.27

Parameter-Efficient Fine-Tuning of Foundation Models for Liver Tumor Segmentation in CT

cs.CV ·2026-09-12 ·Ramtin Mojtahedi, Mohammad Hamghalam, Jacob J. Peoples, Richard K. G. Do, Amber L. Simpson
publishedcode/data similarity 0.59
Abstract · 9 pages, 2 figures, 1 table. Author manuscript of the published SPIE 2026 proceedings paper; LaTeX reconstructed from the author PDF

We evaluated parameter-efficient fine-tuning (PEFT) of the Segment Anything Model (SAM) for liver tumor segmentation in abdominal CT of colorectal liver metastases. We compared Low-Rank Adaptation (LoRA), 4-bit Quantized LoRA (QLoRA), a convolutional adapter (Conv-Adapter), and our Directional Spectral Top-K adapter (DiSCo), training only adapters while freezing the SAM backbone. DiSCo derives spectral bases from singular value decomposition of row-normalized weights and learns rank-gated spectral coefficients, per-output magnitude offsets, and a spectral gain, with optional Top-K rank selection at inference and 0.14 M trainable parameters. We benchmarked five prompting regimes: no prompt, single-point, multi-point, and bounding boxes at intersection over union 0.50 and 0.75. Conv-Adapter and LoRA achieved the highest accuracy (overall Dice 0.793 and 0.792; single-point Dice 0.795 and 0.792; 95th-percentile Hausdorff distance (HD95) 32 mm). QLoRA was close (overall Dice 0.766; single-point Dice 0.768; HD95 36.41 mm), with 0.91 M trainable parameters, 120 ms latency, and 4.9 GB peak memory. DiSCo achieved the highest Dice per million trainable parameters (4.66), with overall Dice 0.653, single-point Dice 0.698, and HD95 49.53 mm. These results show an accuracy-efficiency trade-off and support PEFT for liver tumor segmentation with reduced adaptation costs when compute and labeled data are limited. Code: https://github.com/Ramtin-Mojtahedi/PEFT-SAM-Liver-CT

0.66

DGCM-SSFA: Dual-Granularity Cross-Modulation and Sparse Strip Frequency Attention for Efficient 3T-to-7T MRI Synthesis

cs.CV ·2026-10-21 ·Zhichun Fan, Zhiqiang Chen, Lanling Liu, Lingjun Liu, Zhonghua Xie
publishedbenchmarkhot direction similarity 0.58
Abstract · Accepted by BIBM 2026

Synthesizing high-fidelity 7T MRI from routinely acquired 3T scans offers a practical pathway to enhanced neuroimaging without the prohibitive cost of ultra-high-field scanners. While existing deep learning approaches have achieved promising results, state-of-the-art methods typically rely on either large-scale architectures exceeding 45 million parameters or computationally intensive ensemble strategies, limiting their practicality in resource-constrained clinical environments. In this work, we propose a compact multi-domain attention framework, termed DGCM-SSFA, that achieves competitive synthesis quality with only 11M parameters. The proposed architecture integrates two complementary modules into a U-Net Transformer backbone. First, a Dual-Granularity Cross-Modulated Feature Modulator (DGCM) is embedded at multiple hierarchical levels to enhance local edge and texture details through Sobel-guided spatial attention and depthwise frequency-aware channel attention with cross-branch gating. Second, a Sparse Strip Frequency Attention (SSFA) module at the bottleneck captures global spatial context via strip-pooled attention with near-linear complexity, while simultaneously performing FFT-based spectral modulation in the frequency domain. These two modules operate synergistically with the backbone's native channel attention, forming a triple-granularity feature refinement pipeline. Extensive experiments on the UNC and BNU 3T-to-7T MRI datasets across T1w and T2w modalities demonstrate that DGCM-SSFA achieves strong structural fidelity, attaining an SSIM of 0.8431 on BNU T2w---approaching the best benchmark value of 0.8624---and 0.8100 on BNU T1w, while using substantially fewer parameters than Transformer-based alternatives such as ResViT (123.4M) and FS-RWKV (45.4M).

0.38

MaLViL: Multi-axis Low-rank Vision-LSTM for Medical Image Segmentation

cs.CV ·2026-08-18 ·Afshin Bozorgpour, Sina Ghorbani Kolahi, Moein Heidari, Ilker Hacihaliloglu, Dorit Merhof
publishedcode/data similarity 0.57
Abstract · Accepted at the MICCAI Workshop on Machine Learning in Medical Imaging (MLMI), 2026

Vision-LSTM (ViL) enables efficient global modeling, but its cost still scales with the number of spatial tokens, so existing segmenters confine ViL to a coarse bottleneck and lose fine anatomical detail. Rasterizing 2D features into a 1D sequence further breaks adjacency across the orthogonal scan axis. We propose MaLViL, a Multi-axis Low-rank Vision-LSTM network that extends ViL across decoder resolutions. Bidirectional low-rank ViL (Bi-LRViL) reasons on a compact orthonormal subspace and preserves detail through an orthogonal residual; scale-aware SaLViL restores cross-axis neighbors before serialization; and a Cross-Directional Mixer (CDM) fuses orthogonal horizontal and vertical traversal paths. Statistics-Guided Skip Modulation (SGSM) further retains boundary cues in encoder skips. On skin-lesion, ultrasound, and multi-organ CT benchmarks, MaLViL achieves competitive or state-of-the-art segmentation accuracy, while reducing ViL operator memory by up to $83\times$ at fine decoder resolutions. Code is available at: https://github.com/xmindflow/malvil.

0.40

PACE-MoE: Adaptive Domain Sampling and Domain-Specific LoRA for Medical Visual Grounding

cs.CV ·2026-10-20 ·Zhenxuan Wang, Jisheng Dang, Ronghao Lin, Bimei Wang, Jingwen Zhao +4 more
similarity 0.57
Abstract · 11 pages,3 figures,8 tables

Medical visual grounding requires models to align clinical descriptions with spatial evidence across heterogeneous imaging domains. However, existing multi-domain post-training strategies typically rely on fixed domain sampling and shared parameter updates, overlooking the need to adapt both which domains receive training and where their updates are applied. To address this issue, we propose PACE-MoE, a policy-guided framework that jointly performs adaptive domain sampling and domain-specific adaptation for medical visual grounding. PACE dynamically assesses the training value of each imaging domain from current-policy feedback and progressively adjusts domain coverage through domain admission, replay, and final all-domain balancing. Meanwhile, domain-specific LoRA adapters route updates to the corresponding imaging domains while preserving the pretrained backbone and visual encoder. This coordinated design aligns training-data allocation with parameter adaptation without modifying the original reward formulation or Group Relative Policy Optimization (GRPO) objective. Experiments across seven medical imaging domains show that PACE-MoE consistently improves grounding performance over fixed-domain training, achieving a 3.64% relative improvement in mean box IoU over the Vanilla baseline. Under matched domain-specific adapter architectures, adaptive sampling alone further improves mean box IoU by 2.07%, demonstrating the benefit of policy-guided domain allocation. These results establish coordinated data-parameter routing as an effective strategy for multi-domain medical visual grounding.

0.44

Segment Anything Model Based Context Guided Mamba Unet for Medical Image Segmentation

cs.CV ·2026-10-29 ·Chenchen Wang
similarity 0.56
Abstract

Medical image segmentation is crucial for clinical diagnosis and treatment planning, requiring both global contextual understanding and fine-grained structural precision. While the Segment Anything Model (SAM) demonstrates strong generalization capabilities, its direct application to medical images often lacks domain-specific adaptability. Meanwhile, State Space Models (SSMs)-based methods, such as Mamba, efficiently capture long-range dependencies but may struggle with preserving fine anatomical details. To address these challenges, we propose a segment anything model based context guided mamba unet, SAMBA-UNet, a novel framework that integrates SAM's context knowledge with Mamba's hierarchical feature learning to enhance both global representation and local detail refinement. Specifically, we introduce the Hierarchical Context Enhancement Module (HCEM), an attention-based fusion module that deeply incorporates the multi-level features of SAM and Mamba to improve detail perception and segmentation precision. Additionally, we employ LoRA and Adapter-based fine-tuning to adapt SAM to medical imaging tasks, further enhancing its domain-specific segmentation capability and robustness. We conducted a comprehensive study on several medical segmentation datasets, including Synapse, ISIC17, and ISIC18, evaluating our method across multiple metrics. Experimental results demonstrate that SAMBA-UNet achieves state-of-the-art performance, effectively balancing generalization, segmentation accuracy, and computational efficiency. Our code will be released upon acceptance.

0.20

Topology-Aware Parameter-Efficient Adaptation for Cross-Dataset Retinal Vessel Segmentation

cs.CV ·2026-08-10 ·Yongsong Huang, Tomo Miyazaki, Kai Xu, Xiaofeng Liu, Yaohou Fan +1 more
similarity 0.56
Abstract · This manuscript is currently under peer review. Copyright may subsequently be transferred to the publisher, after which the availability of …

Retinal vessel segmentation in multi-domain deployment requires a source model to adapt to domains that differ in imaging conditions and annotation conventions. Conventional parameter-efficient fine-tuning reduces target-specific storage, but its highly restricted adaptation subspace can be insufficient for reconstructing thin, connected vascular structures. We therefore ask how target-specific capacity should be allocated so that topology-aware supervision remains effective under a strict per-domain parameter budget. Based on this principle, we propose TAPDecoderFT, a topology-responsive, role-structured adaptation framework. Specifically, TAPDecoderFT shares a fixed source parameter state across deployment domains, uses low-rank residuals for target-specific private/fusion feature mixing, and retains a trainable dense-reconstruction path comprising the decoder, output head, and refinement module. To promote structurally faithful predictions, the compact target state is jointly optimized with a region-overlap and topology-aware objective that encourages centerline continuity and thin-branch recovery. It improves both DSC and clDice over GenericLoRA-r4 and narrow TAP-r4 in all six directions and is comparable to full fine-tuning.

0.04