CS Paper Radar

A Controlled Audit of Architectural Complexity in Uncertainty-Aware Multi-Organ Ultrasound Classification

Yang Song, Pengbo Sun, Shichang Feng, Ye Zhu, Xin Xu, Ziran Wang

cs.CV ·submitted 2026-08-28 08:30 UTC · v1

Abstract

Multi-organ ultrasound classifiers increasingly combine attention, mixture-of-experts routing, uncertainty gating, and evidential deep learning (EDL) objectives to address heterogeneous anatomy and acquisition. Yet a plausible design rationale does not by itself establish that an added component improves the trained system. We contribute a controlled complexity-audit framework, applied to the deployment decision between the maximal evidential candidate Full-EDL and simpler alternatives. Six candidates were evaluated on the primary dataset and three in an internal replication, using ten matched seeds, frozen image-level partitions, capacity- and optimisation-aware comparisons, symmetric temperature scaling, paired decision rules, and a separate out-of-distribution (OOD) veto. Retaining Full-EDL did not establish a reliable macro-F1 gain on either dataset, while the simplified alternatives remained inconclusive under the non-inferiority margin. Simple cross-entropy with temperature scaling (Simple-CE+TS) met the calibrated negative log-likelihood criterion on both datasets and showed favourable selective-risk ordering. The raw calibration advantage of evidential training disappeared after temperature scaling and did not recur on the second dataset. The gate had negligible observable influence at the audited checkpoints, and deleting the Full-only chain revealed no stable task or calibrated-loss benefit. Simple-CE nevertheless triggered the OOD veto against the fetal probe but not the lung probe, precluding an unconditional OOD-safety claim. We therefore selected Simple-CE+TS for the evaluated in-distribution objective while retaining Full-EDL as the maximal reference. Components should earn retention through functional and retraining-based evidence, and calibration and distribution-shift reliability should be evaluated separately.

Comment
Supplementary material is available as an ancillary file on this arXiv page

Closest papers

Nearest neighbours by meaning across the whole index.

Generative Active Learning for Label-Efficient Pan-Organ Ultrasound Diagnosis

cs.AI cs.HC ·2026-11-06 ·Yaofei Duan, Yuhao Huang, Yuan Gao, Ruixiang Qi, Tianyu Zhang +7 more
similarity 0.65
Abstract

Medical ultrasound (US) enables real-time, non-invasive diagnosis, yet building US-based AI systems is limited by data scarcity, costly expert annotation, and limited cross-center generalizability. Privacy constraints and instance-level reporting hinder the collection of diverse abnormal cases and frame-level labels, while repeated retraining for new centers increases computational cost. We introduce EvoDiff, a generative active learning framework that integrates diffusion modelling with information-theoretic objectives, evolutionary search, and curriculum-based sampling to select informative samples across heterogeneous US datasets. EvoDiff formulates sample selection as a generate-to-retrieve process, in which diffusion-based optimization in feature space guided by information gain produces synthetic probes, and only the real unlabeled samples retrieved by these probes are annotated and used for downstream training. Across six benchmarks covering fifteen datasets and 16,696 images, we evaluate EvoDiff on convolutional network and transformer-based foundation model. EvoDiff approaches fully supervised performance with substantially fewer labels, outperforms active learning baselines, and improves foundation model generalization under cross-domain external validation on unseen cohorts. A reader study with six radiologists indicates the potential to support clinical annotation workflows, with a model-based estimated 24% to 84% reduction in annotation workload at matched downstream performance.

0.24

Can Multimodal Decision Models Classify Breast Ultrasound Images? Benchmarking CLEF and CLEF-Flash Across Prompts and Datasets

eess.IV cs.CV ·2026-10-09 ·Tran Cao Minh, Hai Tran, Ha Minh Tan
similarity 0.64
Abstract

Multimodal decision models return probabilities over predefined alternatives, offering a structured interface for image classification. This study benchmarks inference with CLEF and CLEF-Flash on 2818 breast ultrasound images from Dataset B, BUSI, and BUS-BRA. Dataset B and BUS-BRA use binary benign-malignant classification, whereas BUSI includes normal, benign, and malignant categories. Model parameters remain unchanged, and original images are submitted without user-defined preprocessing. Three prompts provide minimal labels, an explicit classification task, or sonographic criteria. We report accuracy, macro F1, balanced accuracy, macro precision, throughput, and latency. CLEF-Flash with the clinical prompt achieves the highest accuracy on all three datasets: 74.85% on Dataset B, 66.28% on BUSI, and 51.63% on BUS-BRA. On BUSI, however, CLEF with the task-guided prompt achieves the highest macro F1 (64.51%) and balanced accuracy (68.72%). CLEF-Flash has lower latency in every matched comparison. Clinical instructions improve CLEF-Flash accuracy relative to the minimal prompt but reduce CLEF accuracy on all datasets. Confusion matrices reveal frequent benign-to-malignant errors, particularly on BUS-BRA, where all configurations fall below the 67.63% accuracy of a majority-class predictor. These findings demonstrate dataset-and prompt-dependent performance and motivate class-specific evaluation before applying multimodal decision models to breast ultrasound analysis.

0.52

Architecture-aware Robustness Evaluation of Explainable Deep Learning for Breast Cancer Diagnosis

cs.CV ·2026-09-18 ·Balenthira Thanusanth, Selvarajah Thuseethan, Roshan G. Ragel, Bimali S. Weerakoon, Ayesh Jayasinghe +1 more
code/data similarity 0.63
Abstract · 12 pages, 7 figures

Explainable Artificial Intelligence (XAI) has become essential in medical image analysis to ensure transparency of deep learning (DL)-based diagnostic systems. However, selecting appropriate XAI techniques for breast cancer recognition remains largely ad hoc, with limited systematic evaluation across different DL architectures. This study presents a systematic architecture-aware evaluation protocol to assess the effectiveness of nine widely used XAI techniques across four categories of DL models: very deep, lightweight, transformer-based and hybrid neural networks. The evaluation is conducted on a breast ultrasound dataset comprising 780 images using clinically aligned spatial metrics, including Pointing Game, Intersection over Union and Mean Coverage, to quantify agreement between generated explanations and expert-annotated lesion regions. Results indicate that explanation quality is primarily influenced by the interaction between model architecture and XAI method, rather than any single technique consistently outperforming others. Hybrid architectures produce more spatially coherent explanations, while lightweight and transformer-based models exhibit greater variability across methods. The findings show that no single technique generalises across architectures and evaluation criteria, emphasising the need for joint selection of DL models and XAI techniques. Explainability depends on both model design and explanation strategy and should not be considered independently. This work provides a structured evaluation protocol and practical guidance for selecting XAI techniques in breast cancer diagnosis, supporting more transparent clinical decision-support systems. \textcolor{blue}{Code is publicly available at https://github.com/Nishan-Charlie/Explainable-AI}

0.29

Development and Evaluation of Ultrasound Image Learning Pipelines for MASLD Risk Stratification

eess.IV cs.CV ·2026-09-03 ·Guangyi Zhang, Xiaohong Wang, Eugene Cheah, Peng Guo, Brian A. Telfer +2 more
published similarity 0.62
Abstract · 7 pages, 4 figures. Accepted and presented at IEEE EMBC 2026

Metabolic dysfunction-associated steatotic liver disease (MASLD) affects approximately 30% of the general population. Ultrasound-based imaging, including B-mode imaging and shear wave elastography (SWE), is widely used for noninvasive fibrosis assessment; however, the role of deep learning-based ultrasound image learning for MASLD risk stratification remains insufficiently characterized. In this study, we developed and evaluated ultrasound image learning pipelines using B-mode and SWE images for fibrosis staging and identification of patients with at-risk metabolic dysfunction-associated steatohepatitis (MASH). A total of 250 ultrasound examinations, one exam per subject, were included. Model performance was evaluated using 3-fold cross-validation with area under the receiver operating characteristic curve (AUROC). End-to-end SWE image learning achieved performance comparable to operator-guided SWE across fibrosis stages. Overall, SWE-based learning consistently outperformed B-mode image learning in fibrosis staging, with AUROC improvements from 0.64 (95%CI: [0.56, 0.72]) to 0.72 (95% CI: [0.65, 0.79]) for F>=2 (significant fibrosis, p=0.11), from 0.67 (95%CI: [0.58, 0.75]) to 0.78 (95% CI:[0.72, 0.85]) for F>=3 (advanced fibrosis, p=0.02), and from 0.69 (95%CI: [0.56, 0.82]) to 0.80 (95%CI: [0.72, 0.89]) for F4 (cirrhosis, p=0.10). These findings highlight the potential of SWE image learning for MASLD risk stratification.

0.35

Open ultrasound foundation model for robust segmentation and clinical measurement across heterogeneous settings

cs.CV ·2026-09-16 ·Chao Qin, Fahad Shahbaz Khan, Salman Khan, Sarim Ather, Siddiq Anwar +2 more
code/data similarity 0.62
Abstract · The PDF includes the Supplementary Information. Code is available at https://github.com/AlfredQin/sonobase

Ultrasound is the most widely deployed imaging modality worldwide, yet clinical AI remains fragmented into narrow single-task models that fail when device, operator, or anatomy changes. Here we present SonoCorpus, an open resource unifying 456,963 images and 1,626,085 expert masks from 53 public datasets spanning 24 clinical applications and 17 countries, and SonoBase, an interactive segmentation foundation model pretrained on it. Across fifteen evaluation datasets introducing new organs, devices, operators, and geographies, SonoBase outperforms SAM2, MedSAM2, and the concept-promptable MedSAM3 on every dataset and matches per-dataset specialist models trained on the same data; on fully external data it exceeds the accuracy these baselines achieve on their own in-distribution benchmarks. Ejection fraction derived from its segmentations falls within inter-observer variability (6.63\% error), with fewer misclassifications at the defibrillator-candidacy threshold than either promptable baseline (13\% versus 18--42\%); fetal head-circumference (1.81~mm) and gestational-age (1.2 days) errors fall below inter-observer variability. Where a baseline fails outright, one in four test cases, SonoBase recovers a usable segmentation in 81\% of them, including on handheld probes operated by minimally trained users in two low- and middle-income countries (Sierra Leone and Tanzania). Five labeled examples can help the model adapt to a new setting, and the identical training protocol transfers well to newer models such as SAM3, locating the advantage in ultrasound-specific pretraining rather than any single architecture. To ensure reproducibility and enable the community to build on SonoBase as a platform, we release all checkpoints, optimizer states, data-split indices, deduplication hashes, and starter code at https://github.com/AlfredQin/sonobase.

0.36

C$^2$LUE: Clinically Aligned Patient-Level Ultrasound Diagnosis via Evidence-Aware Multi-Instance Learning

eess.IV cs.CV ·2026-10-09 ·Qin-Yi Zhang, Linying Cao, De-Xing Huang, Haichuan Lin, Yi Yang +5 more
similarity 0.62
Abstract

Patient-level ultrasound diagnosis demands not only high predictive accuracy but also clinically aligned mitigation of asymmetric diagnostic risks. While Multi-Instance Learning (MIL) effectively models routine multi-view exams, standard aggregators often dilute heterogeneous diagnostic cues and optimize solely for global accuracy. This frequently yields undesirable sensitivity-specificity trade-offs. To bridge this gap, we propose C$^2$LUE, a novel MIL framework coupling evidence aware aggregation with risk-aligned regularization. To preserve evidence heterogeneity and prevent unimodal attention collapse, C$^2$LUE employs a multi-query cross-attention mechanism built upon a LoRA-adapted DINOv3 backbone. Multiple latent queries explicitly extract and disentangle diverse morphological patterns from the ultrasound sequence. Furthermore, to improve clinical risk alignment, we introduce a dynamic trade-off regularization objective that penalizes sensitivity-specificity imbalance during training. Rather than leaving the clinical trade-off entirely to post-hoc threshold adjustment, this objective encourages the learned score distribution toward a more balanced operating region. Extensive evaluations on patient-level, biopsy-proven thyroid and breast ultrasound datasets demonstrate that C$^2$LUE consistently outperforms prior alternatives. By uniting strong discrimination with a balanced error profile, C$^2$LUE provides a promising solution for real-world ultrasound screening and diagnosis.

0.21

ProtoCouncil: Multi-Encoder Anatomical Prototypes for Prostate Cancer Detection in Micro-Ultrasound

cs.CV cs.AIcs.LG ·2026-11-06 ·Mohammad Mahdi Abootorabi, Nooshin Maghsoodi, Armin Saadat, Obed Dzikunu, Zhuoxin Guo +6 more
similarity 0.61
Abstract · 12 pages, 3 figures, Under Review

Purpose: Micro-ultrasound ($μ$US) is a promising modality for prostate cancer (PCa) detection, but identifying suspicious tissue depends heavily on clinical experience. Models trained on sparse, noisy core-level pathology offer little insight into their decisions and can fail under domain shift. Clinical use needs a traceable decision process and a flag for uncertain predictions. Methods: We introduce ProtoCouncil, in which three foundation encoders (MedSAM, DINOv3 and V-JEPA 2.1) learn case-based prototypes at three anatomical levels: whole gland, needle track and gland sectors. Prototypes are projected onto real training-core regions, and label-free fusion keeps every class logit as a bias plus an exact sum of prototype similarity contributions. Encoder disagreement triggers selective prediction. Results: In five-fold patient-level cross-validation (6,588 cores, 693 patients), ProtoCouncil reaches 82.9% AUROC for clinically significant PCa (csPCa, Grade Group $\geq$3), 4.3 points above the best previously published method. In zero-shot evaluation on two external cohorts, ProtoCouncil achieves higher all-cancer and csPCa AUROC than all previous methods. Nearest same-class exemplars match test-core tumor involvement better than random same-class cases. Externally, csPCa accuracy falls from 79% when encoders agree to 27% when two oppose the fused call. Abstaining on disagreement raises balanced accuracy by 7 and 15 points, while retaining 58% and 54% of the cores. Conclusion: ProtoCouncil grounds core-level predictions in exact similarity-based evidence from real, anatomically indexed training cases, which makes its reasoning interpretable. It achieves the highest csPCa AUROC across three cohorts and identifies unreliable predictions through encoder disagreement.

0.30

Less Contouring, More Accuracy: Lesion-Guided ROI Deep Learning for Ovarian Ultrasound Classification

cs.CV ·2026-08-26 ·Mehran Ahmad, Ali Abbasian Ardakani, Afshin Mohammadi, Alisa Mohebbi, Gernot Kronreif +1 more
similarity 0.61
Abstract · Submitted as a research article. The manuscript contains figures, tables, and supplementary material

Ovarian lesion classification using transvaginal ultrasound remains challenging due to overlapping imaging characteristics and the dependence on expert interpretation. This study investigates whether lesion-guided region-of-interest (ROI) deep learning can achieve competitive diagnostic performance while reducing the annotation burden associated with pixel-level lesion segmentation. Two publicly available ovarian ultrasound datasets were evaluated: the Multi-Modality Ovarian Tumor Ultrasound (MMOTU) dataset for eight-class classification and the Ovarian Ultrasound Dataset (OUD) for binary classification. Four strategies were compared under a unified framework: global image-based deep learning, lesion-guided ROI-based deep learning, lesion contour-based deep learning, and contour-based radiomics with machine learning classifiers. Four deep learning architectures, MaxViT-Tiny, Swin Transformer, EfficientNet-B7, and ResNet18, were evaluated. Radiomics models were developed using support vector machine, k-nearest neighbors, and artificial neural network classifiers, with ANOVA-based feature selection applied for the lower-sample OUD dataset. The lesion-guided ROI strategy achieved the strongest overall performance, with MaxViT-Tiny obtaining 93.10% accuracy and an AUC of 0.99 on MMOTU and 97.56% accuracy and an AUC of 0.99 on OUD. The contour-based approach achieved comparable accuracy but required substantially higher annotation effort. These findings demonstrate that lesion-guided ROI deep learning provides an effective balance between diagnostic performance and annotation efficiency, offering a practical approach for scalable AI-assisted ovarian ultrasound analysis

0.09