CS Paper Radar

Subtraction-Based Tumor Segmentation and Lesion-Centered pCR Prediction for the MAMA-MIA Challenge

Kai Geissler, Raphael Schäfer

cs.CV cs.AIcs.LG ·submitted 2026-08-29 09:23 UTC · v1
code/data

Abstract

We describe the submission of team FME to the MAMA-MIA Challenge, which evaluated primary tumor segmentation and prediction of pathological complete response (pCR) from pretreatment dynamic contrast-enhanced breast MRI on an external multi-country cohort. For segmentation, we trained a five-fold residual-encoder nnU-Net ensemble using only the first post-contrast minus pre-contrast image, combined with mirroring test-time augmentation and largest-connected-component filtering. For pCR prediction, we ensembled 25 pretrained 3D video classifiers trained on lesion-centred crops from the pre-contrast and first two post-contrast volumes. FME ranked second in both tasks. The segmentation method achieved a combined performance-fairness score of 0.882, with Dice 0.713 and normalized Hausdorff distance 0.099. The pCR method achieved a combined score of 0.664, balanced accuracy of 0.541, and equalized-odds disparity of 0.212. The results indicate that subtraction-based input and ensembling support robust tumor segmentation under cross-site domain shift, whereas pCR prediction from baseline DCE-MRI alone remains limited. For the submission repository, see https://github.com/FraunhoferMEVIS/MAMA-MIA-Challenge-FME

Closest papers

Nearest neighbours by meaning across the whole index.

VGG16-MCA UNet: Whole-Tumor Segmentation in 2D FLAIR MRI with Decoder-Side Channel Attention

eess.IV cs.CV ·2026-09-20 ·Shubham Gajjar, Deep Joshi, Avi Poptani, Vishal Barot
benchmarktheorycode/data similarity 0.72
Abstract · 22 pages, 7 figures, 4 tables. Code and data splits: https://github.com/ShubhamGajjar/vgg16-mca-unet

Automated brain tumor segmentation supports diagnosis, treatment planning, and monitoring of disease progression, but building models that generalize across heterogeneous tumors and limited annotated data remains difficult. We present VGG16-MCA UNet, a hybrid architecture pairing an ImageNet-pretrained VGG16 encoder with a decoder in which a Multi-Channel Attention (MCA) module recalibrates features after each skip-connection fusion, trained with the Focal Tversky loss to counter severe foreground-background imbalance. We evaluate the model as a 2D, FLAIR-only, whole-tumor segmenter on tumor-positive slices from two public datasets: the BraTS 2020 benchmark and the LGG MRI Segmentation dataset. Using 5-fold cross-validation and a single network formed by averaging the weights of the five fold models, the method attains an aggregate pixel-level Dice (F1) of 95.10% on our held-out BraTS 2020 split and 88.32% on LGG. These scores are computed over all test pixels pooled into a single confusion matrix rather than averaged per case, and are therefore not directly comparable to the per-case mean Dice used in the BraTS challenge protocol. All partitions were drawn over individual slices rather than over patients, so every patient contributes slices to both training and test; the figures above therefore measure interpolation within known patients and should be read as an upper bound rather than as generalization to new ones. The model segments a 256x256 slice in 66.32 ms on a single 6 GB NVIDIA RTX 2060, approximately 8 ms more than an equivalent VGG16-UNet without MCA. We release the split records and report the protocol in full, with the aim of providing a precisely specified and reproducible 2D FLAIR baseline.

0.23

MAMA-FLUX.2: Image-to-Image Synthesis of Post-Contrast Breast DCE-MRI for the MAMA-SYNTH Challenge

cs.CV ·2026-08-26 ·Kamil Kwarciak, Marek Wodzinski
similarity 0.68
Abstract · 9 pages, 3 figures, 1 table

Dynamic contrast-enhanced breast MRI is central to cancer diagnosis and monitoring, but requires gadolinium-based contrast agents. In this work, we address pre-to-post contrast breast MRI synthesis for the MAMA-SYNTH challenge. We propose MAMA-FLUX.2, a conditional latent flow-matching approach based on FLUX.2-Klein-4B. The pre-contrast image is encoded as spatial conditioning, while the model predicts the flow field associated with the post-contrast target latent. To adapt the pretrained model efficiently, we use LoRA fine-tuning and introduce a regional training objective combining global flow matching, tumor-region supervision, and stable foreground regularization. We further investigate LoRA rank, intensity windowing, and regional loss weights on axial slices, prioritizing clinically relevant tumor-focused metrics. Our ablation study shows that moderate tumor and stable-foreground weighting improves the trade-off between image fidelity and tumor-region accuracy. The final model achieves the best overall balance with LoRA rank/$α=64/64$, $\mathrm{MHA}_{\max}=25$, $λ_{\mathrm{tumor}}=0.25$, and $λ_{\mathrm{stable}}=0.1$. These results demonstrate that compact pretrained rectified-flow transformers can be adapted for contrast-enhanced MRI synthesis using parameter-efficient fine-tuning and task-aware regional losses.

0.29

Leveraging Segmentation Representations for Efficient Classification: A Self-Configuring Framework Based on nnU-Net

cs.CV cs.AI ·2026-11-17 ·Renjun Cai, Antonio Javier Gallego, Félix Fuentes-Hurtado
benchmark similarity 0.67
Abstract

We propose a self-configuring framework that extends the nnU-Net workflow to both segmentation and classification in 3D medical imaging. Building on nnU-Net's self-configuring method, the framework reuses representations learned by a segmentation model for image-level classification. Its encoder features and predicted segmentation probabilities are used by a lightweight classifier. Two information-sharing strategies are investigated. In the frozen-backbone branch, features are augmented with region-of-interest information, predicted foreground volume, and segmentation confidence. In the adaptation branch, the final encoder stage is partially fine-tuned for classification, with an auxiliary segmentation loss to preserve segmentation-related information. Additional five-fold experiments showed that more complex configurations did not consistently improve classification performance. On the public validation leaderboard, our selected framework achieved an Overall score of 0.8056. In the official FLARE 2026 Task 2 final evaluation, our framework ranked first overall, achieving the highest DSC, NSD, and AUROC across all four testing tasks, including two hidden testing tasks. Local inference measurements also remained below the challenge limits of $60 \mathrm{s}$ per case and $4 \mathrm{GB}$ GPU memory. These results demonstrate the practical value of reusing segmentation representations for classification while maintaining a simple and efficient framework.

0.16

BRACHIO: Broad Representations Across Centres for Head-and-neck Imaging Oncology (HECKTOR 2026)

cs.CV ·2026-10-29 ·Roxanne De Maeyer, Ine Dirks, Yannick Brackenier, Simon DeKeyser, Jef Vandemeulebroucke +1 more
published similarity 0.67
Abstract · HECKTOR Challenge 2026, MICCAI, head and neck cancer, PET imaging

The HECKTOR 2026 challenge benchmarks machine learning for head and neck cancer, where teams delineate primary and nodal tumour volumes, perform TN staging, and predict recurrence-free survival (RFS). This report describes the submissions for the HECKTOR challenge of team nucli. As the three tasks span both dense and global information from multicentric PET/CT scans, we utilise self-supervised pre-trained encoders, training a 2D DINOv2 encoder (PET-DINOv2-MIPs) on HECKTOR 2026's PET scans. Our final test submission ensembles a DynUNet trained from scratch with a SwinUNETR whose Swin trunk was initialised from a SimMIM-pre-trained checkpoint for segmentation, reaching a mean Dice of 0.5409. For TN staging, GTVp/GTVn geometric features from the segmentation masks are fit to stage probabilities by logistic regression (LR) and fused with PET-DINOv2-MIPs deep features (PCA + LR) via a second-level LR, reaching balanced accuracies of 0.3962 (T-stage) and 0.6432 (N-stage). For the RFS prognosis task, we fine-tune the last two blocks of the PET-DINOv2-MIPs ViT-S encoder jointly with an MLP head under a CoxPH loss, concatenating clinical covariates with the imaging features, reaching a test Harrell's C-index of 0.6577 and a weighted challenge score of 0.5802. The prognosis result is comparable to the best entry of the previous edition and consistent with our internal cross-validation, while our segmentation result is well below it and limits the staging results that depend on it.

0.32

Feature Space Guidance for Breast Cancer Classification in DCE-MRI

cs.CV cs.AI ·2026-09-26 ·Benjamin Hamm, Yannick Kirchhoff, Maximilian Rokuss, Moritz Langenberg, Constantin Ulrich +4 more
top venuecode/data similarity 0.67
Abstract · 11 pages, 2 figures, 2 tables. Code: https://github.com/MIC-DKFZ/CURIAtor

Dynamic contrast enhanced breast MRI (DCE-MRI) is a powerful clinical tool for breast cancer detection, providing high resolution anatomical detail together with rich temporal contrast information. However, high dimensional 4D inputs, small lesions, and heterogeneous acquisition protocols across clinical sites hinder robust automated classification of healthy, benign, and malignant cases. To address these challenges, we propose a framework that dynamically analyzes latent representations to adapt to protocol-specific characteristics. Spatial variability is mitigated by reducing confounding background uptake and compensating for misalignment caused by deformable soft tissue. Additionally, relationships in the latent space across phases are leveraged to select the most informative temporal features, improving robustness to protocol-specific temporal variability. Finally, task specific discriminative features are promoted through large scale supervised lesion segmentation pretraining, which substantially enhances downstream finetuning. Evaluated under leave-one-center-out validation on the ODELIA dataset and the held-out AMBL cohort, the proposed framework substantially outperforms finetuned radiology foundation models and prior methods, improving mean AUROC by nearly 8 points and balanced accuracy by 4 points over the strongest baseline. Additionally, our method achieved first place in the MICCAI ODELIA Breast MRI Challenge 2025, further demonstrating its effectiveness for robust breast cancer classification. We publicly release our codebase under https://github.com/MIC-DKFZ/CURIAtor.

0.70

Colorectal Cancer Segmentation with Adaptive Augmentation and Multi-Resolution Ensemble Models

eess.IV cs.AIcs.CV ·2026-09-29 ·Ümit Mert Çağlar, Alptekin Temizel
publishedcode/data similarity 0.66
Abstract · SPIE Eighteenth International Conference on Machine Vision (ICMV 2025), Paris, France

Colorectal cancer (CRC) is the second most deadly and third most common cancer, and the leading cause of death among gastrointestinal cancers. Early diagnosis is crucial for the treatment of this cancer and increasing the survival rates. Although CRC is more common in developed regions, its occurrence is also increasing in developing regions as well. CRC diagnosis relies on histopathology assessment post-biopsy. Automated deep learning algorithms can significantly reduce diagnosis time, enhancing efficiency and supporting timely clinical decisions. We present an automated segmentation pipeline for whole-slide histopathology images that labels tumor grades 1-3 and normal mucosa. It utilizes dense prediction transformers with various encoder backbones, overlapping patches, and test-time augmentation. An adaptive augmentation policy, guided by large language models, further improves training. Top models were ensembled via soft voting, and mask refining post-processing steps, Gaussian blurring, morphological closing, and connected components analysis. On a colorectal cancer grade dataset, our method improved the F1 score from 62.92 to 69.84. Code is available here: github.com/caglarmert/ICIP2025

0.34

Unified CT and MRI Pancreas Segmentation for Label-Efficient Cross-Modality Subregion Transfer

cs.CV cs.AI ·2026-09-11 ·Ziliang Hong, Hongyi Pan, Halil Ertugrul Aktas, Andrea Bejar, Elif Keles +5 more
similarity 0.65
Abstract

Robust medical image segmentation across imaging modalities is challenging because of large differences in appearance and intensity distributions. Models trained on a single modality often show substantial performance drops when applied to unseen domains. In this work, we develop a unified 3D pancreas segmentation framework that applies domain-adversarial learning to 4,604 heterogeneous CT and MRI scans to learn anatomical representations. A shared nnU-Net encoder-decoder is trained for whole-pancreas segmentation, with a latent domain discriminator encouraging CT-MRI feature alignment. The learned encoder is subsequently transferred to pancreatic head-body-tail segmentation using limited MRI-only subregion annotations. An average Dice score of 87.31% on the in-distribution test set and Dice scores ranging from 84.20% to 88.09% across external OOD datasets were achieved in whole pancreas segmentation. Dice scores of 80.53% on MRI and 83.05% on CT were achieved for downstream subregion segmentation, without using CT subregion annotations. These results demonstrate that a unified anatomical representation can support both cross-modality pancreas segmentation and label-efficient downstream transfer.

0.42

Parameter-Efficient pretrained-CT-to-MRI Transfer for Rectal Cancer Segmentation: Performance-Calibration Trade-offs

cs.CV ·2026-08-27 ·Aneesh Rangnekar, Jorge Tapias Gomez, Joseph O Deasy, Harini Veeraraghavan
published similarity 0.65
Abstract · Accepted to the Medical Image AI in Radiation Therapy (MIART) Workshop at MICCAI 2026

Accurate rectal cancer segmentation from magnetic resonance imaging (MRI) is essential for adaptive radiotherapy and tumor response assessment, but deployment also requires computational efficiency and informative, calibrated uncertainty estimates. We therefore introduce SWIFT, a SWin pretrained model wIth parameter-eFficient and Tumor-aware fine-tuning for rectal cancer segmentation. A Swin V2 encoder pretrained on 10,444 public 3D CT volumes using a DINOv2-style objective was adapted to T2-weighted MRI through four cumulative configurations: full fine-tuning (SWIFT), decoder compression (SWIFTe), low-rank adaptation (SWIFTe-LoRA), and a four-member LoRA-decoder ensemble (SWIFTe-LDE4). Geometric accuracy, tumor detection, radiomic agreement, and probability calibration were evaluated on a held-out 247-case test set from a single-institution cohort acquired using 1.5 or 3 Tesla GE scanners. Compared with SWIFT, SWIFTe reduced total parameters by 70.1% (from 72.8M to 21.8M) and increased tumor detection rate from 89.9% to 93.9%, while achieving a slightly lower median surface DSC (0.61 versus 0.62) and improved radiomic agreement. In a separate SWIFTe ablation, removing tumor-aware augmentation reduced detection from 93.9% to 89.9% but increased surface DSC from 0.61 to 0.64, demonstrating a detection-boundary-agreement trade-off. SWIFTe-LoRA used 14.6% of SWIFTe's trainable parameters while retaining similar segmentation performance. SWIFTe-LDE4 achieved the lowest calibration errors among the four configurations after temperature scaling (expected calibration error, 0.217; Brier score, 0.222), although the absolute expected calibration error indicates residual miscalibration. Similar efficiency-calibration patterns were observed using the public VoCo checkpoint, supporting robustness across pretrained initializations rather than external clinical generalizability.

0.41