Abstract

Background: Patient details and acquisition metadata are important for clinical decisions, image quality control, and automated research pipelines, but may be missing or unreliable in imaging archives. Purpose: To develop and evaluate a fast open-source model that predicts patient and acquisition characteristics directly from CT and MR images. Materials and Methods: Separate 3D ResNet-10 ensembles for CT and MR were trained on 57,291 and 43,200 clinical examinations acquired from 2011 to 2025. Both predicted weight, height, age, sex, contrast presence, vertebral coverage, and image noise. The CT model additionally predicted scanner manufacturer, tube voltage, tube current, convolution kernel, and post-injection time; the MR model predicted sequence class. Performance was evaluated on internal CT (n=501) and MR (n=636) test sets and an external CT dataset (n=54). Results: Internal CT MAEs were 3.90 kg, 3.68 cm, and 4.42 years for weight, height, and age, with sex F1=0.990; corresponding MR results were 4.34 kg, 4.62 cm, 7.13 years, and F1=0.970. The CNN outperformed a segmentation-derived XGBoost baseline for all four core targets in both modalities (adjusted P<=.042). F1 scores were 0.963 for CT contrast, 0.953 for MR sequence, and 0.823 for MR contrast. External CT MAEs were 4.45 kg, 4.05 cm, and 5.17 years, with sex F1=0.971. CPU inference required 20 seconds for CT and 12 seconds for MR. Conclusion: One 3D multitask model per modality can rapidly recover patient and acquisition characteristics from heterogeneous CT and MR examinations. Models are available in TotalSegmentator: https://github.com/wasserth/TotalSegmentator

Closest papers

Nearest neighbours by meaning across the whole index.

TotalSynth: Robust Whole-Body Synthetic CT from MRI and CBCT

cs.CV ·2026-09-12 ·Valentin Boussot, Cedric Hemon, Anais Barateau, Caroline Lafond, Jean-Claude Nunes +1 more
similarity 0.64
Abstract · 10 pages, 3 figures

Purpose: To develop and evaluate TotalSynth, a reusable pretrained framework for whole-body synthetic CT (sCT) generation from MRI and cone-beam CT (CBCT) images. Materials and Methods: In this retrospective technical study, the dataset was assembled between 2020 and 2026 from SynthRAD challenge data, four prostate cohorts, and BIC-MAC. After registration quality control, 1450 of 1800 public challenge pairs were retained; 350 were excluded for insufficient registration quality or major source/CT mismatch. The corpus also included 84 additional prostate MRI/CT and 60 external BIC-MAC MRI/CT cases. Three 5-fold model families were evaluated with image-domain, anatomy-aware, registration-based, and uncertainty metrics. Age and sex were not consistently available across public datasets. Results: The released MRI-to-CT model achieved an overall MAE of 67.49 HU, SSIM of 0.920, and PSNR of 29.28 dB. The CBCT-to-CT model achieved an overall MAE of 53.55 HU, SSIM of 0.939, and PSNR of 32.09 dB. The unified model maintained similar performance on MRI inputs (MAE, 67.68 HU) and CBCT inputs (MAE, 54.22 HU). On external BIC-MAC data, MRI-to-CT MAE was 100.91 HU without fine-tuning and 62.21 HU after fine-tuning. Conclusion: TotalSynth provides reusable MRI- and CBCT-based CT synthesis models with broad anatomical coverage, while external evaluation highlights the need for local validation and optional fine-tuning under domain shift.

0.29

The Predictability Bias of Joint-Embedding Predictive Learning in Medical Imaging

eess.IV cs.CVcs.LG ·2026-10-09 ·Fabian Drexel, Bernhard Kainz, Jakob N. Kather, Daniel Rueckert, Lisa C. Adams +2 more
similarity 0.63
Abstract · 45 pages, 6 figures

Joint-embedding predictive architectures (JEPAs) learn by predicting teacher representations of masked regions from visible context. Point prediction summarizes the conditional target distribution and cannot reproduce variation that the context does not resolve. We call this constraint predictability bias. In computed tomography (CT), recurrent anatomy is predictable from context, whereas the sporadic, localized pathology that determines clinical interpretation often is not. We introduce TAP-JEPA, a ViT-B/3D trained on 113,611 CT volumes that is competitive with state-of-the-art encoders (COLIPRI, Merlin, VoxelFM) in scan-level classification. We then audit the learned predictive pathway by replaying the exact masking, teacher, and predictor computations used during training. Prediction lowers the mean Skill (prevalence-normalized average precision) from 0.388 to 0.271 for pathology, but only from 0.921 to 0.873 for anatomy. Along the teacher direction, separating pathology from matched control regions in the same organ, prediction moves pathology 34.7% toward the controls and controls 13.6% toward pathology, with larger shifts farther from visible context. Replacing visible matched-control representations increases surrounding-target prediction loss more than fully replacing pathology representations across four pathology categories. Downstream, removing all final-layer pathology tokens reduces the decision margin by at most 0.45% in four of seven scan-level probes. Together, these results show that contextual predictability is not a sufficient proxy for clinical relevance in medical representation learning. Training objectives should therefore retain diagnostic features regardless of their predictability from surrounding anatomy.

0.19

Grounding Radiology Reports in 3D Chest CT: Results of the ReXGrounding Challenge

cs.CV cs.AI ·2026-11-18 ·Mohammed Baharoon, Mahmoud Hussain Alabbad, Sung Eun Kim, Xiaoman Zhang, Lucas Bijnens +57 more
benchmark similarity 0.62
Abstract · 25 pages, 13 figures, 4 tables

Segmenting each reported finding in a radiology scan would allow findings to be measured and tracked over time and let AI systems generate reports that are verifiable, but so far AI models have performed poorly at this task. To advance this task, we organized the ReXGrounding Challenge at MICCAI 2026, the first challenge dedicated to it. Given a non-contrast chest CT scan and the set of findings from its report, participants trained models to produce the corresponding set of 3D segmentations. The challenge used 2,992 training and 200 validation scans from the ReXGroundingCT dataset, and evaluated methods on a held-out test set of 300 scans with 582 findings, exhaustively annotated by board-certified radiologists. In total, 48 teams from 15 countries made 760 submissions, and the best method reached a Dice of 0.375 and a hit rate of 0.77, matching agreement between two independent radiologist groups (Dice 0.32, hit rate 0.76, on a 50-scan subset). On the 100 scans of the pre-challenge benchmark, the winner reached a Dice of 0.390, against 0.285 for VoxTell, the best model before the challenge, which five of the six best teams fine-tuned. Non-focal findings remained far harder to segment than focal ones, instance F1 stayed below inter-reader agreement (0.34 vs. 0.47), and models sometimes segmented the right abnormality in the wrong location. Top methods thus match radiologist agreement in Dice, but non-focal findings, findings with multiple instances, and adherence to the anatomical location described in the text remain open problems.

0.32

Impact of Pretraining Length, Model Size, and Annotation Budget on Downstream Clinical Tasks of Foundation Models in Radiotherapy

cs.CV ·2026-11-17 ·Alejandro Cortina Uribe, Sidsel Højklint Poulsen, Ivan Richter Vogelius, Jens Petersen
code/data similarity 0.62
Abstract · 9 pages, 5 figures, 2 tables. Supplementary Material included

Cone-beam CT (CBCT) scans acquired during radiotherapy capture changes such as tumor shrinkage and radiation-induced tissue changes, offering great potential for foundation models that help monitor individual treatment responses. However, to our knowledge, no large-scale pretrained models for radiotherapy CBCT exist, and evaluating modeling choices is difficult since downstream tasks are not known in advance. We examine how pretraining length, model size, and finetuning strategy relate to downstream clinical performance, and how metrics tracked during pretraining correlate with it. We pretrain vision transformer encoders with masked image modeling on about 150,000 raw 3D radiotherapy CBCT scans, tracking representation quality via validation loss, effective rank, and linear probing. Downstream tasks are classification of feeding tube presence ($n=51,135$ CBCTs, $1,562$ patients) and clinical characteristics (T-, N-stage, sex, age, tumor site; $n=1,278$ patients) in head and neck cancer. We compare low-rank adaptation (LoRA) and full finetuning against no pretraining, varying annotated dataset size. Pretext validation loss was the most consistent predictor of downstream performance; effective rank and linear probing were also associated, but not consistently across model sizes and finetuning methods. LoRA performed comparably to full finetuning while training only 0.5-2.5% of the parameters. Fully finetuned models consistently outperformed models without pretraining across all sizes, with AUROC 0.91-0.97 vs. 0.58-0.85 for feeding tube classification and 0.99-1.00 vs. 0.71-0.97 for sex classification. Model size had only a small, inconsistent effect, suggesting smaller models suffice at lower computational cost. Code and pretrained models (non-commercial license): https://github.com/alexCortinaU/RT-CBCT_SSL

0.45

How Well Do Generalist CT Foundation Models Differentiate Liver Tumors?

cs.CV cs.AI ·2026-11-18 ·Yosuke Yamagishi, Tomohiro Kikuchi, Shouhei Hanaoka, Takeharu Yoshikawa, Osamu Abe
code/data similarity 0.61
Abstract · 12 pages, 3 figures. Code: https://github.com/yamagishi0824/liver-tumor-ddx-ct-fm

Generalist CT foundation models detect many findings with high performance, but their ability to differentiate detected lesions remains largely unevaluated. This retrospective study evaluated two generalist models, RADAR and Merlin, for differentiating liver tumors using a public single-institution multiphase CT dataset (517 cases: hepatocellular carcinoma, intrahepatic cholangiocarcinoma, breast and colorectal cancer liver metastases, and hemangioma). The models were evaluated in a zero-shot setting using their existing outputs and with linear probing, in which only a linear classifier was trained on frozen image features (stratified fivefold cross-validation repeated five times). In the zero-shot setting, RADAR achieved an accuracy of 54.4% (95% CI: 49.9, 58.8) and a $κ$ of 0.37 for four-class differentiation at the portal venous phase and predicted 31% (129 of 421) of malignant tumors as hemangioma. With linear probing of four-phase features, its accuracy improved to 79.9% (95% CI: 76.6, 83.4) with a $κ$ of 0.72, and 1% (five of 421) of malignant tumors were predicted as hemangioma; Merlin achieved an accuracy of 60.9% (95% CI: 56.9, 65.0). Generalist CT foundation models showed limited zero-shot ability to differentiate liver tumors, which improved substantially with linear probing alone.

0.51

Improving Calibration of Black-Box Radiology AI Using Test-Time Augmentation

cs.LG cs.HC ·2026-09-24 ·Nathan Le, Magdalini Paschali, Arogya Koirala, Andrew Johnston, Zhongnan Fang +3 more
publishedcode/data similarity 0.61
Abstract · 11 pages, 3 figures, 1 table. Accepted at the MICCAI 2026 Workshop on Uncertainty for Safe Utilization of Machine Learning in Medical Imagin…

Radiology AI systems increasingly inform clinical decisions such as triage, follow-up imaging, and treatment planning. For these decisions to be made safely, model outputs must be well calibrated, meaning predicted probabilities accurately reflect true risk. Many standard techniques for improving calibration, such as MC Dropout and Deep Ensembles, require access to model parameters or retraining. However, proprietary clinical AI systems operate as black boxes, preventing access to the model's internals. To that end, we propose a model-agnostic framework for improving calibration of black-box models using clinically grounded test-time augmentation (TTA). Our framework applies geometric and physics-inspired 3D CT perturbations and learns probability-level aggregation strategies without access to model internals or the original training data. Across pulmonary embolism and intracranial hemorrhage detection tasks, DualTTA achieved the strongest overall calibration among TTA methods, reducing the Expected Calibration Error by 54% (0.239 -> 0.109) and 43% (0.051 -> 0.029), respectively, while requiring only input-output access. Additionally, DualTTA outperformed uncertainty estimation techniques that require access to model internals, such as Temperature Scaling, MC Dropout, and Deep Ensembles, in most calibration metrics. These results demonstrate that learned TTA aggregation can improve the calibration of clinical AI systems, providing a practical approach for improving the reliability of black-box medical AI.

0.45

Prior-Guided Physics-Informed Deep Learning for Fast 4D MRI Reconstruction

cs.CV physics.med-ph ·2026-11-01 ·Mojtaba Safari, Parag J. Parikh, Shansong Wang, Mingzhe Hu, Philip Connell +4 more
similarity 0.60
Abstract

Background and purpose: We propose PGPI4MR (prior-guided, physics-informed 4D MRI reconstruction), a deep learning method that leverages information from other respiratory phases or a setup scan, the first 30 s of the same scan, to improve 4D MRI reconstruction without extra scan time. Materials and methods: PGPI4MR is an unrolled network that reconstructs 16 respiratory phases from 60, 30, or 15 s of data, and single 3D volumes, each from 0.29-0.49 s of data, using a setup-scan image. The networks were trained once, on other volunteers, and were not retrained for new volunteers. We evaluated PGPI4MR on measured k-space from three datasets: free-breathing MR-linac (1.5T) and abdominal (3T) scans, and thigh scans with cuff compression (1.5T). All methods, including comparative models, received identical samples and were scored similarly. Results: In vivo, PGPI4MR had the lowest held-out error for 4D MRI at every scan time, and its 16 phases were ready a median of 7.5-13 s after the scan on the 2 GPUs tested. Coupling the 16 respiratory phases reduced the error at 60 s by 9.1% compared with reconstructing each phase alone. For sub-second MRI, the error at 0.49 s was 15.5% lower than that of the best comparison method, classical reconstruction toward the same prior, and on the faster GPU, every 0.29 s window was acquired and reconstructed within 0.5 s. Without retraining, PGPI4MR matched the best methods on the 3T abdominal scans but not on the thigh scans; after retraining on thigh data, it reduced the held-out error by 6.6% relative to the best comparison method. Conclusion: Prior information allowed PGPI4MR to reconstruct 4D and sub-second MRI more accurately than compressed sensing and a published 4D network, within seconds and without extra scan time. This could support 4D MRI for treatment planning and 3D motion monitoring during MR-guided radiotherapy.

0.21

RIQE: a NIQE-style reference model for Computed Tomography

eess.IV cs.CV ·2026-09-30 ·Fabio Mattiussi
code/data similarity 0.59
Abstract · 17 pages, 6 figures, 6 tables. Code and model: https://github.com/Metallogik/RIQE, archived at doi:10.5281/zenodo.23055559

The Natural Image Quality Evaluator (NIQE) scores an image by its statistical distance from a model fitted on pristine images, and its distributed model is fitted on photographs. We release the Radiology Image Quality Evaluator (RIQE), a NIQE-style model fitted on 3,792 full-dose slices from 158 patients of the public LDCT-and-Projection-data collection, with a declared intensity mapping, a manifest of every slice and a script that reproduces the fit. On 40 held-out patients, RIQE ranks reduced-dose reconstructions, simulated by projection-domain noise insertion, worse than the full-dose reconstruction of the same slice in 240 of 240 chest and 230 of 240 abdominal pairs, and ranks images with 20% more noise worse than their source in 97.5-100% of cases. Its preferences among filtered images, however, do not follow lesion signal. With a 4 mm, +10 HU lesion inserted in noisy abdominal slices, RIQE prefers bilateral filtering to the unfiltered image in every image up to a 32 HU residual, at which 29% of the lesion's matched-filter signal remains and its detectability index falls from 0.51 to 0.33; it never prefers Gaussian smoothing, which at the same 32 HU residual leaves 70% of the signal and a detectability index of 0.48. Fitted on photographs with the parameters published for NIQE, the same code ranks every simulated reduced-dose abdominal image better than its full-dose counterpart. RIQE is suited to ranking a degraded image against its source; under the conditions tested it should not be the sole criterion for selecting, comparing or tuning denoisers.

0.58