CS Paper Radar

UnCapsTSR: An Unsupervised Transformer-based Image Super-Resolution Approach for Capsule Endoscopy Images

Anjali Sarvaiya, Shubh Kawa, Lalit Agrawal, Jagrit Joshi, Kishor Upla, Kiran Raja

cs.CV ·submitted 2026-09-02 11:48 UTC · v1
publishedhighly cited

Abstract

Wireless Capsule Endoscopy (WCE) captures and streams video while passing through a patient's Gastrointestinal (GI) tract and is used to examine its irregularities. Although advantageous over conventional endoscopy, WCE suffers from limitations related to capsule size and wireless transmission, resulting in images with coarser resolution. This work presents UnCapsTSR, an unsupervised transformer-based Generative Adversarial Network (GAN) framework for improving the spatial resolution of Low-Resolution (LR) WCE images. The proposed method accomplishes SR without explicit degradation estimation of real-world LR data and eliminates the need for true LR-HR pairs. UnCapsTSR employs a Bilateral Total Variation (BTV) loss to ensure spatial continuity in SR images. A newly curated dataset from the Kvasir Capsule dataset is also presented for training WCE SR models. Generalizability is validated on KID and GIANA datasets that are not used during training. A new non-reference metric, Endoscopy Quality Metric (EndoQM), is introduced for quantitative evaluation of domain-specific WCE data. Experiments demonstrate consistent improvement over state-of-the-art unsupervised SR approaches using NIQE, BRISQUE, PIQE, and EndoQM. Statistical evaluation shows 40 to 80 percent improvement in EndoQM from LR to SR across the evaluated datasets.

Comment
Accepted manuscript of the article published in Neurocomputing, Volume 665, Article 132161, 2026
Journal ref
Neurocomputing, Volume 665, Article 132161, 2026
DOI
10.1016/j.neucom.2025.132161

Closest papers

Nearest neighbours by meaning across the whole index.

CEM-TUDASR: Computationally efficient multi-modality transformer based unsupervised domain adaptive super-resolution approach

cs.CV ·2026-09-10 ·Anjali Sarvaiya, Jay Kadel, Kishor Upla, Kiran Raja
published similarity 0.79
Abstract · Published in Biomedical Signal Processing and Control, Volume 129, 2027, Article 111315

Wireless Capsule Endoscopy (WCE) enables non-invasive visualization of the gastrointestinal tract, but its miniaturized optics, sensor limitations, and wireless transmission constraints result in low-resolution images with reduced visibility of diagnostically important structures. This paper proposes CEM-TUDASR, a computationally efficient unsupervised Transformer-based super-resolution framework for WCE image enhancement without paired low-resolution (LR) and high-resolution (HR) training data. A domain-adaptive degradation network synthesizes realistic WCE-like LR images from HR conventional endoscopy images, reducing the domain gap and enabling effective unpaired learning. The SR generator integrates Deep Attention Blocks (DABs) and a Fusion Attention Block (FAB) to capture long-range contextual dependencies and fine local structures while preserving perceptual and structural fidelity. The model is trained on a curated dataset derived from Kvasir Capsule and evaluated on KID and GIANA for cross-dataset generalization. No-reference quality metrics, including BRISQUE, PIQE, NIQE, and the domain-specific EndoQM, show that CEM-TUDASR consistently outperforms existing unsupervised SR methods. Qualitative results further demonstrate improved restoration of mucosal textures, vascular patterns, and clinically relevant anatomical details. Cross-domain experiments on retinal images additionally demonstrate the adaptability of the framework. With only 2.67 million parameters and 169.94 GFLOPs, CEM-TUDASR achieves high-quality reconstruction while maintaining computational efficiency, making it suitable for resource-constrained clinical and embedded endoscopic applications.

0.18

EndoFSA: Endoscopic Few-Shot Image Generation via Rank-Constrained Parameter Adaptation

cs.CV ·2026-09-24 ·Panagiota Gatoula, Grigoris Karypidis, Dimitris K. Iakovidis
publishedbenchmark similarity 0.72
Abstract · Presented at the 39th IEEE International Symposium on Computer-Based Medical Systems (CBMS 2026), June 2026

WCE produces large-scale gastrointestinal image data yet pathological findings remain significantly underrepresented limiting the generalization performance of deep-learning based abnormality detection systems. SDG methods offer a practical solution to mitigate this imbalance. However their training directly on scarce abnormal samples often results in instability overfitting and structural distortions. Addressing these challenges requires controlled adaptation mechanisms that preserve anatomical priors while enabling realistic pathological variation. This paper presents EndoFSA a GAN-based model for Endoscopic Few-Shot image generation by Adaptation in WCE imaging. EndoFSA leverages a generator pretrained on abundant normal data and adapts it to abnormal domains using limited number of training samples through a rank-constrained parameter adaptation where only a small number of modulation parameters is updated while the pretrained weights remain frozen. By restricting parameter updates to a low dimensional subspace and incorporating perceptual boundary regularization and cluster-wise diversity control EndoFSA enables efficient model adaptation under limited data conditions and mitigates mode collapse while preserving the anatomical priors learned from normal data. Importantly EndoFSA operates without requiring pixel-level annotations, masks or bounding box supervision. Evaluation on publicly available WCE benchmark datasets spanning various abnormal categories demonstrates that EndoFSA generates abnormal images reproducing real lesions morphology. Moreover in a downstream classification task training an image classifier solely on synthetic abnormal images generated by EndoFSA yields performance comparable to that obtained with real images.

0.21

Rethinking Evaluation for Video Capsule Endoscopy: Validation Protocol, Source-Video Diversity, and Cross-Dataset Shift

cs.CV ·2026-11-09 ·Smriti Regmi, Debesh Jha
benchmark similarity 0.65
Abstract · 4 figures and 9 tables

Automated video capsule endoscopy (VCE) classification remains challenging due to severe class imbalance, limited source-video diversity, and variations in image appearance across datasets. Although deep learning models have demonstrated promising performance on established benchmarks, their reliability under different validation protocols and external dataset shift remains insufficiently understood. In this work, we introduce DMSNet, a deformable adaptive multi-scale edge-guided attention network integrating adaptive multi-scale feature fusion, deformable lesion refinement, edge-guided attention, and sparse feature selection. We benchmark DMSNet against 18 representative convolutional, transformer-based, and pretrained vision architectures on Kvasir-Capsule under random frame-level and source-video-disjoint validation protocols. We further identify source-video overlap between the original training and test splits and evaluate model performance on both the complete test set and a source-video-disjoint subset. Under random frame-level validation, DMSNet achieves an MCC of 0.442 $\pm$ 0.020 on complete test set and 0.456 $\pm$ 0.037 on the source-video-disjoint subset. On the external CV2024 dataset, ConvNeXt-Tiny achieves the highest MCC of 0.207, while performance degrades substantially across architectures relative to in-domain evaluation. We further investigate source-video diversity using a per-class cap of 200 training frames. With the total training-set size held fixed, increasing the maximum source-video coverage from four to eight improves MCC for 17 of 19 evaluated architectures. Overall, these findings demonstrate that model rankings and classification performance depend substantially on evaluation protocol, training-source diversity, and cross-dataset shift, emphasizing the need for source-aware validation and rigorous external evaluation of VCE classification systems.

0.21

Multitask Conditional Generative Adversarial Network Enables Automatic Whole Knee Cartilage and Menisci Segmentation and Reliable $T_{1ρ}$ and $T_2$ Quantification Without High-Resolution Morphological Images

cs.CV eess.IV ·2026-10-05 ·Ahmed Tahseen Minhaz, Richard Lartey, Zhiyuan Zhang, Jeehun Kim, Kunio Nakamura +6 more
similarity 0.65
Abstract

Early osteoarthritis detection through quantitative MRI (qMRI) requires accurate cartilage and meniscus segmentation, traditionally necessitating time-consuming, costly 3D high-resolution Double Echo Steady-State (DESS) MRI scans. This study developed a multi-task conditional generative adversarial network (MT-cGAN) to simultaneously synthesize DESS-like images and segment tissues directly from qMRI echo images. This retrospective study evaluated 508 knee MRI volumes from 361 subjects (mean age: $40.4 \pm 12.2$ years; 179 female) across three cohorts. Ground truth segmentation masks were generated from DESS images using a pretrained model with manual correction, and $T_{1ρ}$ and $T_2$ maps were computed from magnetization-prepared angle-modulated partitioned $k$-space spoiled gradient echo snapshots (MAPSS) echo images. MT-cGAN was trained to jointly synthesize DESS-like images and segment cartilage and meniscus directly from echo images. Model performance was evaluated using Dice score for segmentation accuracy and coefficient of variation (CV) for $T_{1ρ}$ and $T_2$ quantification. MT-cGAN achieved the highest segmentation performance, mean Dice score 0.84 (range: 0.80--0.86) across all cartilage and meniscus compartments and significantly outperformed the state-of-the-art conditional GAN model with transfer learning (mean Dice, 0.82; $p < 0.001$, Wilcoxon signed-rank test). For relaxometry quantification, MT-cGAN demonstrated the highest consistency with the reference DESS protocol, yielding the lowest CV ($T_{1ρ}$: 1.84%, $T_2$: 1.81%). The proposed MT-cGAN accurately segmented cartilage and menisci while providing reliable $T_{1ρ}$ and $T_2$ quantification directly from echo images. By eliminating the need for separate morphological DESS scans, this workflow reduces required scan times to facilitate the clinical translation of qMRI.

0.22

TransNSNet: A Transformer-Enhanced Multi-Scale Adversarial Framework for CT-to-PET Image Synthesis

eess.IV cs.CV ·2026-10-16 ·Shaojun Li, Xiaoyu Deng, Ikuo Keshi
similarity 0.64
Abstract · 21 pages, 7 figures. Supplementary material included. Under review at Biomedical Signal Processing and Control

This study investigates CT-to-PET image synthesis using TransNSNet, a Transformer-enhanced multi-scale adversarial framework. A paired CT-PET dataset was curated from the public non-small cell lung cancer (NSCLC) Radiogenomics collection through patient screening, slice-level matching, preprocessing, and patient-level train-test separation. The proposed framework generates PET-like predictions at multiple spatial scales and applies coarse-to-fine reconstruction supervision, while TransPatchGAN introduces contextual feature interaction into adversarial evaluation. A progressive ablation study compares Pix2Pix, NSNet-Base, NSNet-D, and TransNSNet. Image-level performance was summarized over a fixed convergence window (epochs 80-101) from one training run per model. TransNSNet achieved the best mean value in nine of ten metrics, whereas NSNet-Base achieved the highest visual saliency-induced index. For fixed-fraction high-intensity regions, NSNet-D was marginally higher in slice-level recall and balanced accuracy, but the equal-weight patient-level values were nearly identical and the highest Dice values shifted to TransNSNet. These differences were small relative to between-patient variability. In the separate adaptive patient-level analysis (n=10), no pairwise model difference remained statistically significant after Holm correction. TransNSNet also had a substantially smaller parameter footprint than the original next-scale models. These findings indicate promising image-quality trends, but they do not establish statistical superiority or clinical validity; synthesized PET-like images should not be interpreted as substitutes for clinically acquired PET.

0.17

A Comparative Study of GAN-Based Deep Learning Models for Pneumonia Detection in Chest X-Rays

cs.CV ·2026-09-05 ·Roshan Paudel, Aashish Ghimire, Pramod Acharya
similarity 0.64
Abstract

This study evaluates pneumonia classification in chest X-rays using VGG19, MobileNetV2, ResNet50, and a custom CNN, and explores Generative Adversarial Network (GAN)-based synthetic data augmentation. MobileNetV2 achieved the highest reported accuracy of 88% with balanced class-wise performance. The custom CNN achieved pneumonia recall of 92.67% and precision of 79.43%, highlighting a precision-recall trade-off. Accuracy, F1-score, precision, recall, confusion matrices, and training curves were used to assess performance. Synthetic pneumonia images were combined with real images to investigate whether augmentation could improve classification performance. In the reported VGG19 comparison, augmented-data training accuracy reached approximately 100%, while validation accuracy remained near 50%, below the real-data validation accuracy. This experiment therefore did not demonstrate a validation-performance benefit from GAN augmentation. The classifier comparison highlights differences in accuracy and pneumonia recall, while the augmentation experiment indicates the need for further evaluation of synthetic-image quality and training settings.

0.26

GAN-Diff : Coupling Pretrained WGAN-GP Features with Conditional Diffusion U-Nets

cs.CV cs.AIcs.LG ·2026-08-23 ·Saif Ahmed, Asadullah Hil Galib, S. M. Riaz Rahman Antu, Ahmed Faizul Haque Dhrubo, Souvik Pramanik +3 more
similarity 0.64
Abstract · 7 pages, 10 figures, 4 tables

Generative adversarial networks (GANs) can provide efficient image generation, while diffusion models offer high-quality image restoration but require iterative sampling. This paper presents a hybrid GAN-guided diffusion framework that uses a pretrained Wasserstein GAN with gradient penalty (WGAN-GP) as a feature prior for conditional diffusion-based image restoration. Intermediate features from the frozen WGAN-GP generator are incorporated into a diffusion U-Net through cross-attention and remain fixed during the DDIM sampling process. The framework is evaluated on two restoration tasks, Gaussian denoising and 2Xsuper-resolution, using CelebA face images. During development, several sources of instability were identified and addressed, including adversarial learning-rate imbalance, inappropriate diffusion initialization, excessive corruption, and insufficient parameter averaging. The resulting framework consistently improves the quality of both degraded and low-resolution images. In particular, it improves denoising performance by 4.40 dB in PSNR and super-resolution performance by 3.70 dB over their respective input baselines. These results demonstrate the potential of a frozen GAN feature prior to guide diffusion models toward stable and effective image restoration.

0.16

3D Diffusion Models for Medical Imaging

cs.CV ·2026-10-19 ·Frank-Peter Schilling, Daniel Barco, Philipp Denzel, Marc Stadelmann
publishedsurvey similarity 0.62
Abstract · 27 pages, accepted for publication in Informatics in Medicine Unlocked

Generative deep learning methods such as Variational Autoencoders, Generative Adversarial Networks or Diffusion Models have achieved remarkable results in image synthesis. In particular, Diffusion Models have demonstrated superior image fidelity and sample diversity compared to other approaches on standard benchmarks, while also offering more flexible training dynamics as evidenced both in natural image domains and in medical applications. In medical imaging including Computed Tomography, Magnetic Resonance Imaging or Positron Emission Tomography, such models have various important use-cases including data augmentation, domain transfer, image reconstruction, inpainting, image augmentation and artifact correction. Further, generated images can be conditioned on patient characteristics, medical reports, segmentation masks or other images. Specific challenges arise due to the 3D volumetric nature of medical images, which translate to substantial demands in terms of memory, compute, and training data. This article provides a comparative overview of 3D Diffusion Models which have been developed for medical images, with a focus on current performance, limitations, and an outlook for future work.

0.23