CS Paper Radar

Attention-guided super-resolution of 4D flow MRI in carotid arteries

Ali Mokhtari, Dominik Obrist

cs.AI physics.med-phphysics.flu-dyn ·submitted 2026-09-04 08:48 UTC · v1

Abstract

Four-dimensional (4D) flow magnetic resonance imaging (MRI) is a powerful non-invasive technique for visualizing and quantifying complex blood flow patterns in vivo. Despite its clinical promise, broader adoption is limited by low spatial resolution and sensitivity to noise, which restrict accurate assessment of critical hemodynamic biomarkers such as wall shear stress, pressure gradients, and turbulent kinetic energy. To overcome these challenges, we propose a deep learning-based super-resolution framework that integrates multi-scale feature extraction and attention mechanisms to enhance the quality of 4D flow MRI data. The model was trained on a dataset of 120 patients with 240 stenosed carotid arteries. High-resolution ground truth data were generated using patient-specific computational fluid dynamics (CFD) simulations based on segmented vascular geometries and physiologically realistic boundary conditions, and the resulting velocity fields served as targets for supervised learning. The proposed architecture uses convolutional block attention modules (CBAM) to guide the network toward clinically relevant spatial features and to suppress noise in low-resolution inputs. Quantitative results show that the attention-guided model substantially reduces the root mean square error (RMSE) compared with a baseline model without attention, and qualitative velocity contour analysis confirms improved reconstruction of intricate flow patterns. These findings highlight the capacity of the model to restore high-fidelity flow fields under noisy conditions and support the use of deep learning to extend the clinical utility of 4D flow MRI for non-invasive hemodynamic assessment.

Closest papers

Nearest neighbours by meaning across the whole index.

Spatial and Temporal Super-Resolution and Denoising of Intracardiac 4D Flow MRI

cs.CV ·2026-11-02 ·Yusuf A. Ozturk, Jie Zheng, Fanwei Kong
similarity 0.79
Abstract

Intracardiac flow is driven by complex, and time-varying cardiac motion and interaction with the heart valves, producing complex flow features that may provide valuable information for disease diagnosis and treatment planning. 4D Flow MRI enables non-invasive, time-resolved measurement of three-dimensional cardiovascular velocity fields. However, substantial noise and limited spatial and temporal resolution limit its ability to accurately resolve flow features. We propose 4D-MRAR (4D Magnetic Resonance Augmented Reconstruction), a deep learning (DL) method to super-resolve and denoise 4D Flow MRI data. Unlike prior DL methods that train and infer on static vascular regions, our method predicts intracardiac flow within hearts undergoing large deformation. Moreover, it uniquely allows for simultaneous super-resolution in 3D space and time. The method combines a residual convolutional neural network, a recurrent neural network, and an implicit neural field to predict high-resolution velocity and pressure fields while efficiently enforcing the governing equations of fluid flow during training. Trained on a synthetic dataset obtained from computational fluid dynamics (CFD) simulations of left ventricle (LV) flow, our method generalizes to synthetic whole-heart 4D flow MRI data, and demonstrated promising performance on real 4D Flow MRI. The produced super-resolved flow fields exhibit significantly improved accuracy and greater consistency with the governing equations of blood flow compared with prior methods.

0.04

Spectrally optimized implicit neural representations mitigate acquisition-related image quality trade-offs in intracranial 4D Flow MRI

eess.IV cs.CV ·2026-10-23 ·Oliver Welin Odeback, Nerea González-Aranceta, Sebastián Jofre, Javier Bisbal, Edward Ferdian +10 more
similarity 0.77
Abstract · 36 pages, 7 main figures, 2 supplementary figures. Under review at Medical Image Analysis

4D Flow MRI promises opportunities for non-invasive mapping of neurovascular hemodynamics, but its clinical utility faces trade-offs between resolution, acquisition time, and noise. Deep learning-based super-resolution offers a post-scan solution, but supervised approaches require paired or domain-specific data, while patient-specific physics-informed models can be computationally demanding. This creates a need for unsupervised reconstruction models that can adapt to individual acquisitions without paired high-resolution training data, while remaining robust across anatomy, disease severity, and acquisition quality. To address this, we introduce a spectrally tuned implicit neural representation (INR) framework for intracranial 4D Flow MRI, representing the velocity field as a continuous coordinate-based neural field using WIRE activation functions with tunable spectral bias. Data-driven and physics-informed variants were evaluated in nine cerebrovascular cases spanning healthy controls and moderate-to-severe intracranial atherosclerotic disease, using CFD-derived high-resolution reference fields, MR-realistic synthetic low-resolution inputs, and direct fitting to acquired in-vivo data. Cohort-optimal spectral-bias settings generalized across subjects with only small increases in relative error compared with subject-specific optima, reducing the need for case-specific hyperparameter tuning. Physics-informed regularization provided modest additional accuracy but required substantially longer optimization, whereas the data-driven INR achieved near-comparable reconstruction performance within minutes. The framework also remained robust to acquisition-realistic noise and moderate VENC-dependent aliasing. These findings establish spectrally optimized INRs as a flexible unsupervised approach for mitigating acquisition-related trade-offs in intracranial 4D Flow MRI.

0.21

CURRENT: A Recurrent Neural Network for Concurrent Spatial and Temporal Super-Resolution of 4D Flow MRI

cs.CV physics.med-ph ·2026-11-10 ·Luuk Jacobs, Pietro Dirix, Sebastian Kozerke
similarity 0.75
Abstract · Under review

Objective: To improve the spatial and temporal resolution of aortic 4D flow MRI through a unified deep learning framework for post-acquisition super-resolution (SR) of reconstructed velocity vector fields. Methods: We propose CURRENT, a recurrent neural network that performs spatial and temporal SR with a single network architecture. Supervised training was conducted using paired low- and high-resolution datasets generated by embedding computational fluid dynamics simulations of aortic flow into in vivo thoracic MRI backgrounds, followed by controlled spatial and temporal downsampling. CURRENT was evaluated for two-fold spatial and temporal SR against 4DFlowNet and for two-fold spatiotemporal SR against sequential spatial and temporal SR pipelines based on 4DFlowNet. Image-based and k-space-based quantitative metrics were considered and conventional interpolation were used as baselines. In addition, the impact of CURRENT's spatiotemporal SR on physics-informed relative pressure estimation was assessed. Finally, the ability of CURRENT to generalize from synthetic training data to in vivo acquisitions was investigated. Results: CURRENT achieved superior spatial SR performance and comparable temporal SR performance to dedicated 4DFlowNet models while providing a unified solution for both tasks. Simultaneous spatiotemporal SR using CURRENT yielded more accurate relative pressure estimates than either spatial or temporal SR alone and outperformed sequential 4DFlowNet-based spatial and temporal SR approaches. Furthermore, the proposed model demonstrated promising generalization to in vivo 4D flow MRI data despite being trained exclusively on synthetic datasets. Conclusion: CURRENT provides a unified framework for spatial and temporal SR of 4D flow MRI. The proposed approach has the potential to enhance physics-based analysis and broaden the applicability of accelerated 4D flow MRI.

0.17

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

eess.IV cs.AI ·2026-09-16 ·Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye +3 more
similarity 0.72
Abstract

Clinical decision-making for coronary intervention relies mainly on angiography and fractional flow reserve (FFR). However, angiography is two-dimensional and lacks depth information for 3D lesion characterization, while FFR provides only a single functional index, offering limited hemodynamic insight. Among existing methods, numerical analysis is computationally expensive, whereas learning-based approaches require extensive supervision and often lack physical consistency. To address these limitations, we propose physics-informed hemodynamic modeling, an integrated deep learning framework for 3D coronary blood flow analysis from dual-view angiography. First, an attention-enhanced CNN reconstructs coronary geometry from angiography. The resulting point clouds are then mapped to a reference domain and Fourier-encoded for joint representation. A decoupled network separately predicts velocity and pressure fields, with embedded physical priors enabling efficient transfer across physiological conditions. Across 32 clinical patients evaluated under four flow conditions, the trans-stenotic pressure-drop mean absolute percentage error was 2.02%, while the velocity and pressure relative-L2 errors were 0.054 and 0.023, respectively. Validation against hospital-measured FFR further achieved 93.8% diagnostic accuracy (30/32; exact 95% CI, 79.2%-99.2%). The framework also supports illustrative revascularization comparisons and sparse-data assimilation, with the full angiography-to-hemodynamics pipeline completed within 20 minutes per patient.

0.11

Toward Clinical Translation of Deep Learning-Based Intracranial Super-Resolution 4D Flow MRI Using Multi-Cohort Transfer Learning

cs.CV ·2026-10-26 ·Oliver Welin Odeback, Susanne Schnell, Patrick Winter, Johan Lundberg, Fredrik Piehl +3 more
hot direction similarity 0.68
Abstract · 28 pages, 6 main figures, 4 main tables; supplementary material includes 6 sections, 2 figures, and 1 table

We evaluated synthetic pretraining and multi-cohort transfer learning for deep learning-based super-resolution of intracranial 4D Flow MRI across heterogeneous neurologic cohorts. This mixed prospective-retrospective study analyzed 18 participants (12 healthy participants, 3 with moyamoya disease, and 3 with multiple sclerosis) with paired 1.2-mm and 0.6-mm 4D Flow MRI scans. A convolutional neural network pretrained on synthetic cerebrovascular data was fine-tuned using cohort-specific or pooled multi-cohort in vivo data. High-resolution-derived inputs enabled voxel-wise evaluation; native standard-resolution scans were used for angiographic and hemodynamic analyses. Synthetic pretraining reduced mean artery-wise velocity-normalized root mean square error (vNRMSE) versus interpolation (0.147 vs 0.166). Pooled transfer learning yielded the lowest mean vNRMSE (0.119 vs 0.127 for cohort-specific models and 0.147 for synthetic pretraining), with narrower 95% limits-of-agreement widths than synthetic pretraining across all test cases (0.109-0.222 vs 0.154-0.278 m/s). Super-resolved phase-contrast angiography achieved higher precision-recall area under the curve than native standard-resolution imaging in all cohorts (0.848-0.896 vs 0.486-0.805). These results indicate that pooled transfer learning improves cross-cohort reconstruction agreement and that super-resolution can improve vessel depiction, supporting further multi-center validation for cerebrovascular imaging.

0.25

Vessel2Brain: Edge-Aware Multi-Scale Flow Matching for 3D Brain Image Generation from Vessel Masks

cs.CV ·2026-11-13 ·Zhi Chen, Tianyang Zhang, Theodoros N. Arvanitis, Le Zhang
similarity 0.68
Abstract

Generating realistic 3D brain MRI volumes from sparse anatomical priors is a highly ill-posed yet clinically valuable problem, with important applications in data augmentation, simulation, and downstream neuroimaging analysis. In this work, we investigate the challenging task of synthesising full 3D brain MRI volumes conditioned solely on vascular label maps. While vascular structures provide strong anatomical and topological cues, they occupy only a small fraction of the brain volume and offer no direct information about surrounding tissue appearance. To address this challenge, we propose Vessel2Brain, an edge-aware multi-scale conditional flow matching framework that explicitly incorporates vascular structure information into the generative process. Our approach formulates vessel-guided brain image synthesis as a conditional continuous flow, enabling stable training and flexible generation while preserving structural correspondence. A multi-scale flow matching strategy is introduced to jointly model global anatomical coherence and fine-grained local details, with auxiliary velocity predictions providing additional supervision across spatial resolutions. Furthermore, we design an edge-aware objective that emphasises vascular boundaries during training, encouraging anatomically faithful tissue synthesis around vessel structures. We evaluate Vessel2Brain on two public 3D brain MRI datasets with paired vascular annotations. Extensive quantitative and qualitative experiments demonstrate that our method consistently outperforms state-of-the-art generative models in terms of reconstruction accuracy, structural consistency, and distributional realism.

0.13

FlowMoDL: Model-Based Deep Learning with Conjugate-Gradient Data Consistency for Highly Accelerated 4D Flow MRI Reconstruction

cs.CV cs.LG ·2026-08-26 ·Tristan Gottwald, Michelle Bruch, Mubashir-Ul Hassan, Fatma Alickovic, Milan Kloiber +4 more
similarity 0.68
Abstract

We present FlowMoDL, an unrolled neural network for highly accelerated 4D flow MRI reconstruction that directly optimizes for both anatomical magnitude and phase-derived velocity accuracy. Building on the MoDL framework, FlowMoDL alternates a learned (3+1)D spatiotemporal denoiser with conjugate-gradient data-consistency updates based on the SENSE forward model. A novel dual-pathway conditioning scheme adapts the denoiser features and data-consistency weighting, enabling a single model to handle varying acceleration factors ($10\times$ to $50\times$). To ensure physiological accuracy, the network is trained using a deep-supervision composite loss that explicitly penalizes velocity magnitude and angular errors, stabilized by a curriculum schedule. We evaluate FlowMoDL on the multi-center CMRx4DFlow dataset against classical and deep-learning baselines (CG-SENSE, MoDL, FlowVN, and FlowMRI-Net). A key advantage of FlowMoDL is its superior gradient step efficiency. When evaluated under an equivalent, limited budget of gradient steps, competing flow-specific networks degrade significantly. In contrast, FlowMoDL robustly converges and strictly outperforms all competitors across all acceleration factors in magnitude SSIM, nRMSE, relative velocity error, and angular error, successfully recovering sharp structural details and temporally coherent velocity fields.

0.09

VascuSR: Iterative Anatomy-Aware Diffusion for CT Super-Resolution

cs.CV cs.AIcs.LG ·2026-10-14 ·Hairong Ni, Jiahe Huang, Minghao Guo, Wojciech Matusik, Rose Yu
similarity 0.67
Abstract

Generative super-resolution (SR) can recover sharp detail in computed tomography (CT) images from severely downsampled observations, but the missing high-frequency content is not uniquely determined by the low-resolution input. Consequently, visually plausible reconstructions may contain anatomically unsupported vascular detail, such as missing, spurious, or incorrectly connected vessels. To overcome this challenge, we introduce VascuSR, an iterative anatomy-aware diffusion framework that combines image reconstruction with explicit 3D vascular guidance. First, to provide richer anatomical guidance, we use an explicit 3D vascular representation that captures structural information beyond individual slices. This representation also simplifies vascular refinement by allowing a lightweight 3D generative refiner to focus on vascular structure rather than complex CT appearance. Second, to guide slice-wise SR, a lightweight anatomy controller injects the refined structure into the diffusion decoder, while iterative feedback updates this guidance from each new SR volume. On re-annotated MSD Task08 and HVM datasets, VascuSR outperforms interpolation and learning-based SR baselines in segmentation accuracy (Dice and clDice) and 3D vascular structure (connectivity and mean centerline distance), while maintaining image quality comparable to its SR backbone. Compared with learning-based baselines, VascuSR reduces class-averaged connected-component counts by over 20% on both datasets and mean centerline distance by over 10% on MSD.

0.23