CURRENT: A Recurrent Neural Network for Concurrent Spatial and Temporal Super-Resolution of 4D Flow MRI

Luuk Jacobs, Pietro Dirix, Sebastian Kozerke

cs.CV physics.med-ph ·submitted 2026-11-10 13:25 UTC · v1

Abstract

Objective: To improve the spatial and temporal resolution of aortic 4D flow MRI through a unified deep learning framework for post-acquisition super-resolution (SR) of reconstructed velocity vector fields. Methods: We propose CURRENT, a recurrent neural network that performs spatial and temporal SR with a single network architecture. Supervised training was conducted using paired low- and high-resolution datasets generated by embedding computational fluid dynamics simulations of aortic flow into in vivo thoracic MRI backgrounds, followed by controlled spatial and temporal downsampling. CURRENT was evaluated for two-fold spatial and temporal SR against 4DFlowNet and for two-fold spatiotemporal SR against sequential spatial and temporal SR pipelines based on 4DFlowNet. Image-based and k-space-based quantitative metrics were considered and conventional interpolation were used as baselines. In addition, the impact of CURRENT's spatiotemporal SR on physics-informed relative pressure estimation was assessed. Finally, the ability of CURRENT to generalize from synthetic training data to in vivo acquisitions was investigated. Results: CURRENT achieved superior spatial SR performance and comparable temporal SR performance to dedicated 4DFlowNet models while providing a unified solution for both tasks. Simultaneous spatiotemporal SR using CURRENT yielded more accurate relative pressure estimates than either spatial or temporal SR alone and outperformed sequential 4DFlowNet-based spatial and temporal SR approaches. Furthermore, the proposed model demonstrated promising generalization to in vivo 4D flow MRI data despite being trained exclusively on synthetic datasets. Conclusion: CURRENT provides a unified framework for spatial and temporal SR of 4D flow MRI. The proposed approach has the potential to enhance physics-based analysis and broaden the applicability of accelerated 4D flow MRI.

Comment
Under review

Closest papers

Nearest neighbours by meaning across the whole index.

Spatial and Temporal Super-Resolution and Denoising of Intracardiac 4D Flow MRI

cs.CV ·2026-11-02 ·Yusuf A. Ozturk, Jie Zheng, Fanwei Kong
similarity 0.81
Abstract

Intracardiac flow is driven by complex, and time-varying cardiac motion and interaction with the heart valves, producing complex flow features that may provide valuable information for disease diagnosis and treatment planning. 4D Flow MRI enables non-invasive, time-resolved measurement of three-dimensional cardiovascular velocity fields. However, substantial noise and limited spatial and temporal resolution limit its ability to accurately resolve flow features. We propose 4D-MRAR (4D Magnetic Resonance Augmented Reconstruction), a deep learning (DL) method to super-resolve and denoise 4D Flow MRI data. Unlike prior DL methods that train and infer on static vascular regions, our method predicts intracardiac flow within hearts undergoing large deformation. Moreover, it uniquely allows for simultaneous super-resolution in 3D space and time. The method combines a residual convolutional neural network, a recurrent neural network, and an implicit neural field to predict high-resolution velocity and pressure fields while efficiently enforcing the governing equations of fluid flow during training. Trained on a synthetic dataset obtained from computational fluid dynamics (CFD) simulations of left ventricle (LV) flow, our method generalizes to synthetic whole-heart 4D flow MRI data, and demonstrated promising performance on real 4D Flow MRI. The produced super-resolved flow fields exhibit significantly improved accuracy and greater consistency with the governing equations of blood flow compared with prior methods.

0.04

Attention-guided super-resolution of 4D flow MRI in carotid arteries

cs.AI physics.med-phphysics.flu-dyn ·2026-09-04 ·Ali Mokhtari, Dominik Obrist
similarity 0.75
Abstract

Four-dimensional (4D) flow magnetic resonance imaging (MRI) is a powerful non-invasive technique for visualizing and quantifying complex blood flow patterns in vivo. Despite its clinical promise, broader adoption is limited by low spatial resolution and sensitivity to noise, which restrict accurate assessment of critical hemodynamic biomarkers such as wall shear stress, pressure gradients, and turbulent kinetic energy. To overcome these challenges, we propose a deep learning-based super-resolution framework that integrates multi-scale feature extraction and attention mechanisms to enhance the quality of 4D flow MRI data. The model was trained on a dataset of 120 patients with 240 stenosed carotid arteries. High-resolution ground truth data were generated using patient-specific computational fluid dynamics (CFD) simulations based on segmented vascular geometries and physiologically realistic boundary conditions, and the resulting velocity fields served as targets for supervised learning. The proposed architecture uses convolutional block attention modules (CBAM) to guide the network toward clinically relevant spatial features and to suppress noise in low-resolution inputs. Quantitative results show that the attention-guided model substantially reduces the root mean square error (RMSE) compared with a baseline model without attention, and qualitative velocity contour analysis confirms improved reconstruction of intricate flow patterns. These findings highlight the capacity of the model to restore high-fidelity flow fields under noisy conditions and support the use of deep learning to extend the clinical utility of 4D flow MRI for non-invasive hemodynamic assessment.

0.25

FlowMoDL: Model-Based Deep Learning with Conjugate-Gradient Data Consistency for Highly Accelerated 4D Flow MRI Reconstruction

cs.CV cs.LG ·2026-08-26 ·Tristan Gottwald, Michelle Bruch, Mubashir-Ul Hassan, Fatma Alickovic, Milan Kloiber +4 more
similarity 0.72
Abstract

We present FlowMoDL, an unrolled neural network for highly accelerated 4D flow MRI reconstruction that directly optimizes for both anatomical magnitude and phase-derived velocity accuracy. Building on the MoDL framework, FlowMoDL alternates a learned (3+1)D spatiotemporal denoiser with conjugate-gradient data-consistency updates based on the SENSE forward model. A novel dual-pathway conditioning scheme adapts the denoiser features and data-consistency weighting, enabling a single model to handle varying acceleration factors ($10\times$ to $50\times$). To ensure physiological accuracy, the network is trained using a deep-supervision composite loss that explicitly penalizes velocity magnitude and angular errors, stabilized by a curriculum schedule. We evaluate FlowMoDL on the multi-center CMRx4DFlow dataset against classical and deep-learning baselines (CG-SENSE, MoDL, FlowVN, and FlowMRI-Net). A key advantage of FlowMoDL is its superior gradient step efficiency. When evaluated under an equivalent, limited budget of gradient steps, competing flow-specific networks degrade significantly. In contrast, FlowMoDL robustly converges and strictly outperforms all competitors across all acceleration factors in magnitude SSIM, nRMSE, relative velocity error, and angular error, successfully recovering sharp structural details and temporally coherent velocity fields.

0.09

Spectrally optimized implicit neural representations mitigate acquisition-related image quality trade-offs in intracranial 4D Flow MRI

eess.IV cs.CV ·2026-10-23 ·Oliver Welin Odeback, Nerea González-Aranceta, Sebastián Jofre, Javier Bisbal, Edward Ferdian +10 more
similarity 0.71
Abstract · 36 pages, 7 main figures, 2 supplementary figures. Under review at Medical Image Analysis

4D Flow MRI promises opportunities for non-invasive mapping of neurovascular hemodynamics, but its clinical utility faces trade-offs between resolution, acquisition time, and noise. Deep learning-based super-resolution offers a post-scan solution, but supervised approaches require paired or domain-specific data, while patient-specific physics-informed models can be computationally demanding. This creates a need for unsupervised reconstruction models that can adapt to individual acquisitions without paired high-resolution training data, while remaining robust across anatomy, disease severity, and acquisition quality. To address this, we introduce a spectrally tuned implicit neural representation (INR) framework for intracranial 4D Flow MRI, representing the velocity field as a continuous coordinate-based neural field using WIRE activation functions with tunable spectral bias. Data-driven and physics-informed variants were evaluated in nine cerebrovascular cases spanning healthy controls and moderate-to-severe intracranial atherosclerotic disease, using CFD-derived high-resolution reference fields, MR-realistic synthetic low-resolution inputs, and direct fitting to acquired in-vivo data. Cohort-optimal spectral-bias settings generalized across subjects with only small increases in relative error compared with subject-specific optima, reducing the need for case-specific hyperparameter tuning. Physics-informed regularization provided modest additional accuracy but required substantially longer optimization, whereas the data-driven INR achieved near-comparable reconstruction performance within minutes. The framework also remained robust to acquisition-realistic noise and moderate VENC-dependent aliasing. These findings establish spectrally optimized INRs as a flexible unsupervised approach for mitigating acquisition-related trade-offs in intracranial 4D Flow MRI.

0.21

Segmentation of the aorta in 4D flow MRI using 4D convolutional kernels and learning from sparse annotations

cs.CV ·2026-09-03 ·Hinrich Rahlfs, Julio Garcia, Chiara Manini, Markus Hüllebrand, Sebastian Schmitter +11 more
code/data similarity 0.71
Abstract · Submitted to Journal of Cardiovascular Magnetic Resonance

Automated aortic segmentation in 4D flow MRI is essential for reproducible hemodynamic assessment but is limited by scarce dense annotations and high computational demands. We developed a fully automated 4D (3D+time) U-Net for segmenting the ascending aorta, arch, and proximal descending aorta, using a parameter-efficient hybrid 4D kernel to capture temporal context and sparse 4D labels derived from existing 2D expert contours and centerlines, thereby avoiding the need for dense 4D annotations. Training comprised 268 scans from 8 centers and 2 vendors, with evaluation on an internal test set (32 scans) and an external post-contrast set (30 scans; different site, protocol, and annotator), compared against frame-wise 3D networks and two semi-automatic references. Against time-resolved annotations, the 4D U-Net achieved Dice scores of 0.927 (internal) and 0.911 (external), versus 0.919/0.847 for the 3D U-Net, 0.893 for static PC-MRA, and 0.808 for registration-based propagation; differences were small in systole but pronounced in diastole. Agreement with expert contours for peak velocity, net flow, axial and circumferential wall shear stress, and diameters was excellent (ICC >=0.954 internal, >=0.980 external), while semi-automatic references performed worse. The method thus provides reproducible, time-resolved aortic segmentation for automated hemodynamic analysis and generalizes across multicenter, multivendor, and independent post-contrast data. The model is publicly available.

0.45

Toward Clinical Translation of Deep Learning-Based Intracranial Super-Resolution 4D Flow MRI Using Multi-Cohort Transfer Learning

cs.CV ·2026-10-26 ·Oliver Welin Odeback, Susanne Schnell, Patrick Winter, Johan Lundberg, Fredrik Piehl +3 more
hot direction similarity 0.70
Abstract · 28 pages, 6 main figures, 4 main tables; supplementary material includes 6 sections, 2 figures, and 1 table

We evaluated synthetic pretraining and multi-cohort transfer learning for deep learning-based super-resolution of intracranial 4D Flow MRI across heterogeneous neurologic cohorts. This mixed prospective-retrospective study analyzed 18 participants (12 healthy participants, 3 with moyamoya disease, and 3 with multiple sclerosis) with paired 1.2-mm and 0.6-mm 4D Flow MRI scans. A convolutional neural network pretrained on synthetic cerebrovascular data was fine-tuned using cohort-specific or pooled multi-cohort in vivo data. High-resolution-derived inputs enabled voxel-wise evaluation; native standard-resolution scans were used for angiographic and hemodynamic analyses. Synthetic pretraining reduced mean artery-wise velocity-normalized root mean square error (vNRMSE) versus interpolation (0.147 vs 0.166). Pooled transfer learning yielded the lowest mean vNRMSE (0.119 vs 0.127 for cohort-specific models and 0.147 for synthetic pretraining), with narrower 95% limits-of-agreement widths than synthetic pretraining across all test cases (0.109-0.222 vs 0.154-0.278 m/s). Super-resolved phase-contrast angiography achieved higher precision-recall area under the curve than native standard-resolution imaging in all cohorts (0.848-0.896 vs 0.486-0.805). These results indicate that pooled transfer learning improves cross-cohort reconstruction agreement and that super-resolution can improve vessel depiction, supporting further multi-center validation for cerebrovascular imaging.

0.25

Joint Supervised and Self-Supervised Training with Acquisition-Robust Techniques for Accelerated 4D Flow MRI Reconstruction

eess.IV cs.CV ·2026-09-29 ·Mengyuan Xue, Bochun Mei
similarity 0.68
Abstract

4D flow MRI measures time-resolved, three-directional blood velocity but requires long acquisition times, and its diagnostic signal is carried by the phase difference \emph{between} velocity encodings, not by image magnitude. Recent work has developed a per-encoding variational network to address image reconstruction in this field. In this work, we incorporate a joint supervised and self-supervised training regime and utilize both magnitude and velocity data during supervision. At the same time, we add multiple acquisition-robust and conditioning strategies based on the acceleration factors. On the CMRx4DFlow~2026 aortic dataset (1.5 and 3T), our model lowers RelErr by $38$--$50\%$ and AngErr by $7.0$--$8.7^\circ$ against a training-matched baseline across $R{=}10$--$50$, improving on every held-out subject at every acceleration. Our model also shows strong generalization ability to transfer on out-of-distribution data by employing the joint training scheme, with an increase of $7.2\%$ in SSIM and decrease of $38\%$ and $31\%$ in AngErr and RelErr respectively.

0.12

Reconstruction of 4D Mitral Regurgitation Hemodynamics from Sparse Planar Data using Deep Operator Networks with Test-Time Adaptation

cs.LG physics.med-phphysics.flu-dyn ·2026-08-31 ·Jakob Marcel Hoffmann, Yosuke Hasegawa, Alexander Stroh
similarity 0.68
Abstract

Quantifying mitral regurgitation severity remains limited by the assumptions of clinical flow convergence methods, while high-fidelity simulation and volumetric velocimetry are too slow for routine use. We investigate whether a learned solution operator can reconstruct transient three-dimensional transvalvular hemodynamics from the sparse observation an in-vitro experiment actually provides: a single planar velocity slice and two boundary pressure traces. A Deep Operator Network is pretrained on an experimentally benchmarked URANS database spanning eleven mitral regurgitation orifice phantoms, learning a mapping from a masked two-component planar velocity snapshot to the surrounding volumetric field, and is subsequently adapted to unseen target cases by fine-tuning on their sparse measurements. Adaptation reliably corrects the flow topology within the supervised plane, reorienting a strongly eccentric jet that the pretrained operator predicts as straight, and yields full-field predictions in minutes rather than the days required by the underlying simulations. Its influence decays sharply with distance from that plane, however: measured against phase-resolved particle image velocimetry, the reconstruction error rises from 24.6% at 2mm to 52.6% at 6mm, and the resulting mismatch between corrected and uncorrected layers degrades physical consistency. Single-plane supervision thus constrains the observed plane far more effectively than the surrounding volume, which we identify as the principal obstacle to coherent 4D reconstruction from sparse planar data.

0.18