CS Paper Radar

Toward Clinical Translation of Deep Learning-Based Intracranial Super-Resolution 4D Flow MRI Using Multi-Cohort Transfer Learning

Oliver Welin Odeback, Susanne Schnell, Patrick Winter, Johan Lundberg, Fredrik Piehl, Tobias Granberg, Alexander Fyrdahl, David Marlevi

cs.CV ·submitted 2026-10-26 13:11 UTC · v1
hot direction

Abstract

We evaluated synthetic pretraining and multi-cohort transfer learning for deep learning-based super-resolution of intracranial 4D Flow MRI across heterogeneous neurologic cohorts. This mixed prospective-retrospective study analyzed 18 participants (12 healthy participants, 3 with moyamoya disease, and 3 with multiple sclerosis) with paired 1.2-mm and 0.6-mm 4D Flow MRI scans. A convolutional neural network pretrained on synthetic cerebrovascular data was fine-tuned using cohort-specific or pooled multi-cohort in vivo data. High-resolution-derived inputs enabled voxel-wise evaluation; native standard-resolution scans were used for angiographic and hemodynamic analyses. Synthetic pretraining reduced mean artery-wise velocity-normalized root mean square error (vNRMSE) versus interpolation (0.147 vs 0.166). Pooled transfer learning yielded the lowest mean vNRMSE (0.119 vs 0.127 for cohort-specific models and 0.147 for synthetic pretraining), with narrower 95% limits-of-agreement widths than synthetic pretraining across all test cases (0.109-0.222 vs 0.154-0.278 m/s). Super-resolved phase-contrast angiography achieved higher precision-recall area under the curve than native standard-resolution imaging in all cohorts (0.848-0.896 vs 0.486-0.805). These results indicate that pooled transfer learning improves cross-cohort reconstruction agreement and that super-resolution can improve vessel depiction, supporting further multi-center validation for cerebrovascular imaging.

Comment
28 pages, 6 main figures, 4 main tables; supplementary material includes 6 sections, 2 figures, and 1 table

Closest papers

Nearest neighbours by meaning across the whole index.

Spectrally optimized implicit neural representations mitigate acquisition-related image quality trade-offs in intracranial 4D Flow MRI

eess.IV cs.CV ·2026-10-23 ·Oliver Welin Odeback, Nerea González-Aranceta, Sebastián Jofre, Javier Bisbal, Edward Ferdian +10 more
similarity 0.75
Abstract · 36 pages, 7 main figures, 2 supplementary figures. Under review at Medical Image Analysis

4D Flow MRI promises opportunities for non-invasive mapping of neurovascular hemodynamics, but its clinical utility faces trade-offs between resolution, acquisition time, and noise. Deep learning-based super-resolution offers a post-scan solution, but supervised approaches require paired or domain-specific data, while patient-specific physics-informed models can be computationally demanding. This creates a need for unsupervised reconstruction models that can adapt to individual acquisitions without paired high-resolution training data, while remaining robust across anatomy, disease severity, and acquisition quality. To address this, we introduce a spectrally tuned implicit neural representation (INR) framework for intracranial 4D Flow MRI, representing the velocity field as a continuous coordinate-based neural field using WIRE activation functions with tunable spectral bias. Data-driven and physics-informed variants were evaluated in nine cerebrovascular cases spanning healthy controls and moderate-to-severe intracranial atherosclerotic disease, using CFD-derived high-resolution reference fields, MR-realistic synthetic low-resolution inputs, and direct fitting to acquired in-vivo data. Cohort-optimal spectral-bias settings generalized across subjects with only small increases in relative error compared with subject-specific optima, reducing the need for case-specific hyperparameter tuning. Physics-informed regularization provided modest additional accuracy but required substantially longer optimization, whereas the data-driven INR achieved near-comparable reconstruction performance within minutes. The framework also remained robust to acquisition-realistic noise and moderate VENC-dependent aliasing. These findings establish spectrally optimized INRs as a flexible unsupervised approach for mitigating acquisition-related trade-offs in intracranial 4D Flow MRI.

0.21

CURRENT: A Recurrent Neural Network for Concurrent Spatial and Temporal Super-Resolution of 4D Flow MRI

cs.CV physics.med-ph ·2026-11-10 ·Luuk Jacobs, Pietro Dirix, Sebastian Kozerke
similarity 0.70
Abstract · Under review

Objective: To improve the spatial and temporal resolution of aortic 4D flow MRI through a unified deep learning framework for post-acquisition super-resolution (SR) of reconstructed velocity vector fields. Methods: We propose CURRENT, a recurrent neural network that performs spatial and temporal SR with a single network architecture. Supervised training was conducted using paired low- and high-resolution datasets generated by embedding computational fluid dynamics simulations of aortic flow into in vivo thoracic MRI backgrounds, followed by controlled spatial and temporal downsampling. CURRENT was evaluated for two-fold spatial and temporal SR against 4DFlowNet and for two-fold spatiotemporal SR against sequential spatial and temporal SR pipelines based on 4DFlowNet. Image-based and k-space-based quantitative metrics were considered and conventional interpolation were used as baselines. In addition, the impact of CURRENT's spatiotemporal SR on physics-informed relative pressure estimation was assessed. Finally, the ability of CURRENT to generalize from synthetic training data to in vivo acquisitions was investigated. Results: CURRENT achieved superior spatial SR performance and comparable temporal SR performance to dedicated 4DFlowNet models while providing a unified solution for both tasks. Simultaneous spatiotemporal SR using CURRENT yielded more accurate relative pressure estimates than either spatial or temporal SR alone and outperformed sequential 4DFlowNet-based spatial and temporal SR approaches. Furthermore, the proposed model demonstrated promising generalization to in vivo 4D flow MRI data despite being trained exclusively on synthetic datasets. Conclusion: CURRENT provides a unified framework for spatial and temporal SR of 4D flow MRI. The proposed approach has the potential to enhance physics-based analysis and broaden the applicability of accelerated 4D flow MRI.

0.17

Attention-guided super-resolution of 4D flow MRI in carotid arteries

cs.AI physics.med-phphysics.flu-dyn ·2026-09-04 ·Ali Mokhtari, Dominik Obrist
similarity 0.68
Abstract

Four-dimensional (4D) flow magnetic resonance imaging (MRI) is a powerful non-invasive technique for visualizing and quantifying complex blood flow patterns in vivo. Despite its clinical promise, broader adoption is limited by low spatial resolution and sensitivity to noise, which restrict accurate assessment of critical hemodynamic biomarkers such as wall shear stress, pressure gradients, and turbulent kinetic energy. To overcome these challenges, we propose a deep learning-based super-resolution framework that integrates multi-scale feature extraction and attention mechanisms to enhance the quality of 4D flow MRI data. The model was trained on a dataset of 120 patients with 240 stenosed carotid arteries. High-resolution ground truth data were generated using patient-specific computational fluid dynamics (CFD) simulations based on segmented vascular geometries and physiologically realistic boundary conditions, and the resulting velocity fields served as targets for supervised learning. The proposed architecture uses convolutional block attention modules (CBAM) to guide the network toward clinically relevant spatial features and to suppress noise in low-resolution inputs. Quantitative results show that the attention-guided model substantially reduces the root mean square error (RMSE) compared with a baseline model without attention, and qualitative velocity contour analysis confirms improved reconstruction of intricate flow patterns. These findings highlight the capacity of the model to restore high-fidelity flow fields under noisy conditions and support the use of deep learning to extend the clinical utility of 4D flow MRI for non-invasive hemodynamic assessment.

0.25

Spatial and Temporal Super-Resolution and Denoising of Intracardiac 4D Flow MRI

cs.CV ·2026-11-02 ·Yusuf A. Ozturk, Jie Zheng, Fanwei Kong
similarity 0.64
Abstract

Intracardiac flow is driven by complex, and time-varying cardiac motion and interaction with the heart valves, producing complex flow features that may provide valuable information for disease diagnosis and treatment planning. 4D Flow MRI enables non-invasive, time-resolved measurement of three-dimensional cardiovascular velocity fields. However, substantial noise and limited spatial and temporal resolution limit its ability to accurately resolve flow features. We propose 4D-MRAR (4D Magnetic Resonance Augmented Reconstruction), a deep learning (DL) method to super-resolve and denoise 4D Flow MRI data. Unlike prior DL methods that train and infer on static vascular regions, our method predicts intracardiac flow within hearts undergoing large deformation. Moreover, it uniquely allows for simultaneous super-resolution in 3D space and time. The method combines a residual convolutional neural network, a recurrent neural network, and an implicit neural field to predict high-resolution velocity and pressure fields while efficiently enforcing the governing equations of fluid flow during training. Trained on a synthetic dataset obtained from computational fluid dynamics (CFD) simulations of left ventricle (LV) flow, our method generalizes to synthetic whole-heart 4D flow MRI data, and demonstrated promising performance on real 4D Flow MRI. The produced super-resolved flow fields exhibit significantly improved accuracy and greater consistency with the governing equations of blood flow compared with prior methods.

0.04

Combining General and Domain-Specific Pretext Tasks for Brain MR Image Segmentation

cs.CV cs.AI ·2026-09-25 ·Tasneem Nasser, Susanne Schmid, Roberto Souza, Naser El-Sheimy
code/data similarity 0.63
Abstract · 7 figures, 5 tables

A key challenge in medical image analysis is the scarcity of large annotated datasets for specific populations and diseases. As deep learning models rely heavily on labeled data, effective transfer learning strategies are needed to reduce the dependence on manual annotations. Self-supervised learning has emerged as a promising approach for developing foundation models by enabling the learning of transferable feature representations from large-scale unlabeled medical imaging datasets. In this study, we investigate voxel-level brain age prediction as a domain-specific self-supervised pretext task and compare it with image inpainting, a widely used non-domain-specific alternative. We further propose a multitask self-supervised pretraining framework that jointly optimizes both objectives to learn complementary neuroimaging representations. The pretrained models are evaluated on three downstream magnetic resonance image segmentation tasks: multiple sclerosis lesion segmentation, ischemic stroke lesion segmentation, and cortical brain structure segmentation. Overall, the proposed multitask pretraining framework consistently outperformed the single-task pretrained models and training from scratch across most experimental settings, demonstrating the benefit of combining domain-specific and general self-supervised learning pretext tasks for the development of generalizable neuroimaging foundation models.\ Code Availability: The source code used in this study is publicly available at https://github.com/TasneemN/Combining-General-and-Domain-Specific-Pretext-Tasks-for-Brain-MR-Image-Segmentation/

0.30

Ischemic Stroke Segmentation and Net Water Uptake Quantification on Multicenter Non-Contrast CT Using Supervised Target-Domain Adaptation

cs.CV ·2026-09-17 ·Linus Britt, Maximilian Nielsen, Susan Klapproth, Andre Kemmling, Michael H. Lev +3 more
similarity 0.62
Abstract

Objectives: Quantitative assessment of infarct hypodensity on non-contrast computed tomography (NCCT), including net water uptake (NWU), requires manual or semi-manual lesion delineation, often guided by CT perfusion or diffusion-weighted MRI, limiting clinical applicability. Automated segmentation on NCCT could enable efficient biomarker extraction such as NWU but remains challenging across heterogeneous multicenter data. This study aimed to develop and externally test a domain-aware deep learning framework for ischemic stroke segmentation on NCCT and assess its suitability for NWU quantification. Materials & Methods: In this retrospective multicenter study of 801 patients from four datasets, an nnU-Net-based model was trained on NCCT scans from the University Medical Center Hamburg-Eppendorf and the Acute Ischemic Stroke Dataset. To adapt to new domains, the model was fine-tuned on target-domain subsets from Boston (n=11) and ISLES (n=75), with evaluation on held-out cases not used for fine-tuning. Automated segmentations and NWU values were compared with expert references. Results: For lesions $\geq$ 30 mL, median Dice was 0.68 (Boston) and 0.56 (ISLES). Including smaller lesions, which predominated in ISLES, median Dice was 0.54 (interquartile range [IQR] 0.30-0.70) for acute lesion segmentation (Boston dataset) and 0.20 (IQR 0.03-0.41) for NCCT lesion segmentations when compared to post-treatment infarct (primary target of the ISLES challenge). Automated NWU mean absolute error was 1.37 percentage points (SD 1.61, Boston). Conclusion: Target-domain adaptation supported NCCT-only infarct segmentation across heterogeneous external cohorts, although performance varied across domains. The approach enabled low-error NWU quantification from baseline NCCT without advanced imaging, supporting further prospective clinical evaluation.

0.04

FlowMoDL: Model-Based Deep Learning with Conjugate-Gradient Data Consistency for Highly Accelerated 4D Flow MRI Reconstruction

cs.CV cs.LG ·2026-08-26 ·Tristan Gottwald, Michelle Bruch, Mubashir-Ul Hassan, Fatma Alickovic, Milan Kloiber +4 more
similarity 0.62
Abstract

We present FlowMoDL, an unrolled neural network for highly accelerated 4D flow MRI reconstruction that directly optimizes for both anatomical magnitude and phase-derived velocity accuracy. Building on the MoDL framework, FlowMoDL alternates a learned (3+1)D spatiotemporal denoiser with conjugate-gradient data-consistency updates based on the SENSE forward model. A novel dual-pathway conditioning scheme adapts the denoiser features and data-consistency weighting, enabling a single model to handle varying acceleration factors ($10\times$ to $50\times$). To ensure physiological accuracy, the network is trained using a deep-supervision composite loss that explicitly penalizes velocity magnitude and angular errors, stabilized by a curriculum schedule. We evaluate FlowMoDL on the multi-center CMRx4DFlow dataset against classical and deep-learning baselines (CG-SENSE, MoDL, FlowVN, and FlowMRI-Net). A key advantage of FlowMoDL is its superior gradient step efficiency. When evaluated under an equivalent, limited budget of gradient steps, competing flow-specific networks degrade significantly. In contrast, FlowMoDL robustly converges and strictly outperforms all competitors across all acceleration factors in magnitude SSIM, nRMSE, relative velocity error, and angular error, successfully recovering sharp structural details and temporally coherent velocity fields.

0.09

GenFAR: A generalized representation of brain structure, derived from 49,246 multi-cohort MRIs via deep learning

cs.CV ·2026-08-12 ·Vishnu M. Bashyam, Guray Erus, Junhao Wen, Pratik Chaudhari, Randa Melhem +27 more
similarity 0.62
Abstract

Deep learning models for neuroimaging have largely been developed for individual tasks, limiting knowledge transfer across applications. Here we introduce GenFAR, a modular deep learning framework that learns general, clinically informed features from brain MRIs. We trained this modular architecture on 49,246 individuals across 11 cohorts, using 17 diverse classification and regression tasks spanning cognition, clinical, diagnosis, demographics, and biomarkers. This yields aggregated, focused feature sets that capture rich, clinically- and biologically-relevant brain representations. We developed a sequential learning approach where tasks progressively build on previously learned representations. Through an analysis of 5,000 task sequences, we identified an optimal sequence length of six tasks and introduced a Donor Score metric to quantify each task's contribution to downstream performance. This analysis revealed five consistently strong donor tasks (Age, AD/MCI, MMSE, Hypertension, Hyperlipidemia) that formed the base of our sequential model. We demonstrated the utility of our learned representation, in various tasks beyond those included in the training set, to serve as the foundation for specialized secondary predictors. We further showed that using the learned feature representation can substantially increase the sample efficiency of secondary deep learning training tasks and models, as well as improve their accuracy.

0.04