CS Paper Radar

Review on State-of-the-art Energy Systems in the Arctic

Bilal Babar, Sabrina Sartori

eess.SY ·submitted 2026-09-09 10:17 UTC · v3

Abstract

The Arctic regions remain heavily dependent on fossil fuels for energy generation. At the same time, the Arctic is warming at a rate considerably faster than the global average, increasing the need for low-carbon and climate-resilient energy systems. This review documents the current energy systems and assesses state-of-the-art energy solutions applicable to Arctic and cold-climate regions, as well as the future direction of these emerging energy systems, and analyses the role of energy storage, heating requirements, and advanced energy solutions. A total of 88 research articles were systematically reviewed. The reviewed studies indicate the potential for wind and solar to reduce dependence on fossil-fuel based energy generation. For energy storage, the reviewed solutions include hydrogen for long-term storage, battery-based system for short-term storage and regulation, and thermal storage using boreholes to meet heating demand. Where a fully renewable system cannot provide the required reliability, diesel can serve as back up generation. Some barriers to widespread adoption are technological, such as the need for specialized planning tools and equipment resilient to harsh weather, and social and institutional, such as the need for governmental support, subsidies, and appropriate legal frameworks.

Comment
35 pages, 6 figures and 6 tables, preprint, title updated

Closest papers

Nearest neighbours by meaning across the whole index.

Modelling the Nordic power system expansion with PyPSA-Eur: a comparison with the Nordic Grid Development Perspective 2025

eess.SY ·2026-10-09 ·Leonardo Rydin Gorjão, Heidi S. Nygård
published similarity 0.57
Abstract · Conference proceedings, 4 figures, 6 pages

We compare the Nordic Grid Development Perspective 2025 (NGDP) with a least-cost transition pathway for the Nordic power system obtained with PyPSA-Eur for the period 2025-2050 under a net-zero CO$_2$ constraint. The model co-optimises generation, storage, and transmission expansion with hourly system operation while constraining the Nordic generation mix to remain consistent with NGDP milestone ranges. Overall, the optimised capacity pathways reproduce the broad NGDP expansion of wind and solar power, with Denmark emerging as the main locus of offshore wind and solar deployment, Finland as a major site for onshore wind expansion, and Norway and Sweden relying more strongly on existing hydropower and nuclear capacity. The main discrepancy between the two pathways does not lie in the broad build-out of variable renewables, but in the timing and role of hydrogen. Whereas the NGDP treats hydrogen as an early and steadily increasing component of industrial demand and system development already from 2030, PyPSA-Eur delays substantial hydrogen deployment until 2045-2050, when it becomes cost-effective primarily as a flexibility and seasonal storage option in a strongly variable-renewable-energy-dominated system. This contrast suggests that early hydrogen build-out in the Nordics is not a robust outcome of cost optimisation alone, but depends strongly on assumptions regarding industrial demand growth, sector coupling, and anticipatory infrastructure planning. We therefore argue that hydrogen remains the principal strategic uncertainty in the Nordic transition, with the NGDP representing a more anticipatory planning perspective and PyPSA-Eur a more conservative least-cost timing of deployment.

0.37

Co-Optimized Generation, Transmission, and Storage Expansion: System Value and Optimal Duration of Pumped-Storage Hydropower

eess.SY math.OC ·2026-08-27 ·Rafael Benchimol Klausner, Rafael Kelman
similarity 0.54
Abstract

Expansion planning models usually fix storage duration before optimization, setting how much storage power to build but not for how long it can discharge. We present a generation-transmission-storage expansion framework in which candidates of many durations compete on annualized cost, making the duration mix an optimization outcome. It is a rolling-horizon, two-stage stochastic linear program, each five-year stage is a full year at hourly resolution under ten coherent inflow, wind, and solar scenarios. We apply it to the Brazilian Interconnected System over 2030-2050, where demand roughly doubles to 1,716 TWh/year and variable renewable energy (VRE) supplies most new capacity. Two cases are compared: 36 pumped-storage hydropower (PSH) candidates over four subsystems and nine durations (4-144 h) alongside 4-h battery energy storage systems (BESS), and BESS alone. With PSH available, the model builds 31.2 GW / 755 GWh of PSH and no BESS, dominated by 12-h capacity with 4.9 GW of 72-h units. Without PSH it builds 38 GW / 152 GWh of BESS and 7.8 GW more gas-fired capacity, mostly open-cycle peakers. PSH lowers 2050 annualized system cost by US$ 5.0 billion/year (6.8%), operating cost by 23.5%, thermal generation by 34 TWh/year, and long-run marginal cost by 20%; 2035 VRE curtailment falls from 8.4% to 3.2%. The magnitudes are specific to Brazil, but the underlying mechanism is general: limiting storage candidates to a single duration understates the system's optimal energy-storage requirement and overstates its residual need for thermal capacity.

0.30

Reassessing Clean Power 2030 Pathway Using Real Time Records

eess.SY ·2026-10-19 ·Anthony D Stephens, David R Walwyn
similarity 0.53
Abstract · 18 pages, 8 tables, 5 figures

The National Energy System Operator (NESO) Clean Power 2030 advice to the government, accepted as United Kingdom (UK) government policy in December 2024, outlines a rapid increase in wind and solar generation capacities with the associated infrastructure by 2030, with the objective of reducing carbon dioxide emissions from the UK electricity system to 5.2 million tons per annum. Our previous paper used real-time records from 2017 to analyze Clean Power 2030 proposal. This paper extends the previous assessment, using real time records of 2017, 2018 and 2019 to test the resilience of the UK energy system under more diverse weather patterns. Two different modelling methods predict that the 2030 carbon dioxide emissions will be five times greater than Clean Power 2030 prediction. Furthermore, the projections show that, due to increased curtailment, only about half of NESO proposed increases in wind and solar capacities will be economically justified. NESO also advised the government that 35GW of unabated gas-fired generation would maintain security of supply, whereas our models suggest that at least 42 GW will be required during winter wind lulls. Recent events, such as grid stability problems in 2026, also discussed in the paper, validate our estimated and suggest the risk of blackouts in the UK is increasing.

0.27

Plant-Wide Hierarchical Electricity-Heat Coordination for Large-Scale Cold-Region ReP2H Plants via Bidirectional Thermal Coupling

eess.SY math.OC ·2026-08-10 ·Yiwei Qiu, Baiping Zhu, Tao Wu, Shi Chen, Buxiang Zhou +1 more
similarity 0.51
Abstract

Large-scale renewable power-to-hydrogen (ReP2H) plants in cold regions suffer from prolonged startup and repeated thermal stress during frequent startup-shutdown operation. The situation becomes worse due to the lack of coordinated heat management among the alkaline electrolysis stacks, balance of plant (BoP), plant thermal utility system (PTUS), and plant building. This paper presents a plant-wide thermal topology and a hierarchical electricity-heat management framework to address the issues. Bidirectional thermal coupling between the stack cluster and PTUS enables preheating, thermal standby, and waste heat recovery, while minute-scale production scheduling is coordinated with second-scale thermal regulation. Case studies based on an 80 MW plant in Northern China show that the proposed framework eliminates cold startups in year round, increases hydrogen yield by 1.50, improves energy and exergy efficiencies by 0.99 and 4.33 percentage points, respectively, and reduces the levelized cost of hydrogen by 3.22%. It also reduces thermal fatigue damage and startup-shutdown-induced voltage degradation.

0.04

Building Seasonal Highways for Residential Energy Hubs: Sizing, planning and operating thermal energy storage

eess.SY math.OC ·2026-10-01 ·Dario Slaifstein, Mohammad Khosravi, Gautham Ram Chandra Mouli, Laura Ramirez-Elizondo, Pavol Bauer
similarity 0.50
Abstract

The operation of residential energy hubs with multiple energy carriers (electricity, heat, mobility) poses a significant challenge due to the energy storage differences in time-constants, round-trip efficiencies and self-discharge rates. Usually, thermal storage exhibits flexibility in yearly planning optimizations or long-term scenarios. However, as optimization horizons shrink (1-48hs) so does their supplied value due to the lower round-trip efficiencies. To avoid this early depletion during operation this paper proposes a data-driven highway to steer the short-term daily control towards long-term optimality. The proposed methodology also presents how to optimally size the thermal storage and avoid yearly simulations and how all of this is related to nonlinearities in the daily operation. The presented framework links seasonal and daily optimizations through dynamic terminal sets and value functions. The seasonally-aware nonlinear economic model predictive controller achieves the most balanced performance, with the second best mean grid cost of all MPCs at -\texteuro 209. It also achieves better battery degradation control than its linear counterparts (between 26-34%) and the best thermal comfort of the nonlinear benchmarks. Nevertheless, the data-driven seasonal highway restrains the ability to control battery degradation and slightly increases computational time.

0.14

Impact of Wind-Solar-Battery Growth on Electricity Prices: Reserve Scarcity and Transmission Congestion

eess.SY ·2026-11-14 ·Haoxiang Wan, Ivan Castillo, Xingpeng Li
similarity 0.50
Abstract · 7 pages, 3 figures, 2 tables. Submitted to IEEE GECA 2027

This paper asks whether sequential wind, solar, and battery storage additions that eliminate unserved energy also remove modeled reserve scarcity and transmission congestion. Thirty-one cumulative portfolio states are evaluated on a modified IEEE 24-bus system for a constructed stressed day using a 24-hour day-ahead unit commitment model with network constraints, co-optimized energy and upward reserve, chronological battery storage, and an approximation of the Electric Reliability Council of Texas operating reserve demand curve. The thermal baseline has 106 MWh of unserved energy, whereas 450 MW of wind is sufficient to serve all demand. However, with 1,500 MW of wind, the hourly modeled reserve scarcity price still reaches \$5,000/MWh because wind output declines after the system peak. Adding 1,800 MW of solar reduces the load weighted daily average modeled reserve scarcity price from \$1,136.2/MWh to \$101.2/MWh and confines modeled reserve scarcity to three evening hours. Adding 250 MW/1,000 MWh of battery storage further lowers the average to \$4.3/MWh and reduces wind curtailment from 631 MWh to 306 MWh. Transmission congestion nevertheless remains: all residual wind curtailment occurs at bus 21, wind capture prices at buses 21 and 23 differ by \$31.8/MWh, and identical battery storage plants yield normalized net energy market revenues of \$201/(MW$\cdot$day) and \$121/(MW$\cdot$day) at buses 19 and 21, respectively. These results show that unserved energy, modeled reserve scarcity, and locational congestion effects measure distinct operating conditions and should be evaluated separately but interpreted together.

0.27

Beyond Tomorrow -- Electrification of Hard-to-Abate Sectors

eess.SY ·2026-09-28 ·Jonas Huber, Johann W. Kolar
similarity 0.50
Abstract · Submitted to IEEE magazine

Reaching net-zero greenhouse-gas (GHG) emissions requires deep electrification beyond ground transportation, buildings, and conventional industry automation. This article discusses direct electrification pathways for hard-to-abate sectors, which today account for 30% of global GHG emissions and include steel, cement, chemicals, aviation, and shipping. Whereas indirect electrification via hydrogen and synthetic fuels will remain indispensable for some applications, direct use of electricity is generally preferable from an efficiency perspective. We review selected emerging opportunities for power electronics in industrial process electrification, including steelmaking through hydrogen plasma smelting reduction or molten-oxide electrolysis, electrified cement production, high-temperature process heat, plasma-assisted chemistry, and electrochemical synthesis. Across these examples, power converters must interface with highly application-specific loads, ranging from low-voltage high-current electrolysis cells to dynamic plasma reactors and megawatt-scale induction heating systems. In addition, high-power grid interfaces and in-plant energy management/buffering solutions must be clarified. Thus, future electrified industrial processes open new "beyond-tomorrow" research challenges for power electronics in close interdisciplinary collaboration with scientists from neighboring disciplines.

0.26

Massachusetts' 2026 Clean Peak Standard Recalibration: Adaptation and Storage Tradeoffs

eess.SY ·2026-09-29 ·Yuhan Dai, Boyu Yao
published similarity 0.49
Abstract · Accepted for IEEE GESS 2026

Massachusetts recalibrated its Clean Peak Standard (CPS) in 2026 by lowering the minimum standards and expanding the Near-Term Resource Multiplier for qualifying storage. This paper evaluates the change using a three-zone, hourly capacity expansion model for 2026--2030. Both scenarios achieve full CPS compliance, but the post-May scenario reduces new battery additions by 53.1% and modeled system cost by 3.7%. CPS-eligible discharge declines by 30.4%, while Clean Peak Energy Certificate production declines by only 9.5%. Fossil generation during CPS hours increases by 11.7%, whereas modeled emissions remain nearly unchanged because the Regional Greenhouse Gas Initiative cap binds. The recalibration therefore lowers the modeled storage capacity requirement while weakening physical clean-peak performance.

0.36