CS Paper Radar

Reassessing Clean Power 2030 Pathway Using Real Time Records

Anthony D Stephens, David R Walwyn

eess.SY ·submitted 2026-10-19 12:57 UTC · v1

Abstract

The National Energy System Operator (NESO) Clean Power 2030 advice to the government, accepted as United Kingdom (UK) government policy in December 2024, outlines a rapid increase in wind and solar generation capacities with the associated infrastructure by 2030, with the objective of reducing carbon dioxide emissions from the UK electricity system to 5.2 million tons per annum. Our previous paper used real-time records from 2017 to analyze Clean Power 2030 proposal. This paper extends the previous assessment, using real time records of 2017, 2018 and 2019 to test the resilience of the UK energy system under more diverse weather patterns. Two different modelling methods predict that the 2030 carbon dioxide emissions will be five times greater than Clean Power 2030 prediction. Furthermore, the projections show that, due to increased curtailment, only about half of NESO proposed increases in wind and solar capacities will be economically justified. NESO also advised the government that 35GW of unabated gas-fired generation would maintain security of supply, whereas our models suggest that at least 42 GW will be required during winter wind lulls. Recent events, such as grid stability problems in 2026, also discussed in the paper, validate our estimated and suggest the risk of blackouts in the UK is increasing.

Comment
18 pages, 8 tables, 5 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Which wind and solar modelling choices matter? Effects on capacity factors, energy droughts and European power system configuration

eess.SY ·2026-10-29 ·L. Karkossa, A. Grochowicz, M. J. Koivisto, A. Hahmann, M. VIctoria
similarity 0.66
Abstract

Europe's future power system will rely heavily on wind and solar power and must remain resilient during prolonged periods of low wind and solar generation, known as variable renewable energy (VRE) droughts. To capture such rare events, adequacy assessments increasingly draw on decades of weather data, but the conversion of weather into power is largely treated as fixed. It remains unclear which modelling choices in this conversion matter for representing these droughts, and whether they matter as much as the weather itself. Here we systematically compare these choices side by side (bias correction, wind speed extrapolation, capacity layouts, turbine and photovoltaic configurations, and wake losses) and trace their effects through VRE droughts to the design of a net-zero European power system, using 85 years of reanalysis data. We find that modelling choices barely change how often VRE droughts occur or when the system is stressed. They do, however, determine how much capacity is needed to withstand that stress. By altering the electricity delivered during droughts, they shift required capacity by up to 480 GW, which is comparable to the spread across the most critical weather years. Modelling exercises should therefore use multiple weather years; bias-correct and regionally validate weather inputs; explicitly represent resource heterogeneity, forward-looking technologies, and wake losses; and judge these choices by their effect on the low-generation tail, not only on the mean.

0.24

Massachusetts' 2026 Clean Peak Standard Recalibration: Adaptation and Storage Tradeoffs

eess.SY ·2026-09-29 ·Yuhan Dai, Boyu Yao
published similarity 0.56
Abstract · Accepted for IEEE GESS 2026

Massachusetts recalibrated its Clean Peak Standard (CPS) in 2026 by lowering the minimum standards and expanding the Near-Term Resource Multiplier for qualifying storage. This paper evaluates the change using a three-zone, hourly capacity expansion model for 2026--2030. Both scenarios achieve full CPS compliance, but the post-May scenario reduces new battery additions by 53.1% and modeled system cost by 3.7%. CPS-eligible discharge declines by 30.4%, while Clean Peak Energy Certificate production declines by only 9.5%. Fossil generation during CPS hours increases by 11.7%, whereas modeled emissions remain nearly unchanged because the Regional Greenhouse Gas Initiative cap binds. The recalibration therefore lowers the modeled storage capacity requirement while weakening physical clean-peak performance.

0.36

Modelling the Nordic power system expansion with PyPSA-Eur: a comparison with the Nordic Grid Development Perspective 2025

eess.SY ·2026-10-09 ·Leonardo Rydin Gorjão, Heidi S. Nygård
published similarity 0.56
Abstract · Conference proceedings, 4 figures, 6 pages

We compare the Nordic Grid Development Perspective 2025 (NGDP) with a least-cost transition pathway for the Nordic power system obtained with PyPSA-Eur for the period 2025-2050 under a net-zero CO$_2$ constraint. The model co-optimises generation, storage, and transmission expansion with hourly system operation while constraining the Nordic generation mix to remain consistent with NGDP milestone ranges. Overall, the optimised capacity pathways reproduce the broad NGDP expansion of wind and solar power, with Denmark emerging as the main locus of offshore wind and solar deployment, Finland as a major site for onshore wind expansion, and Norway and Sweden relying more strongly on existing hydropower and nuclear capacity. The main discrepancy between the two pathways does not lie in the broad build-out of variable renewables, but in the timing and role of hydrogen. Whereas the NGDP treats hydrogen as an early and steadily increasing component of industrial demand and system development already from 2030, PyPSA-Eur delays substantial hydrogen deployment until 2045-2050, when it becomes cost-effective primarily as a flexibility and seasonal storage option in a strongly variable-renewable-energy-dominated system. This contrast suggests that early hydrogen build-out in the Nordics is not a robust outcome of cost optimisation alone, but depends strongly on assumptions regarding industrial demand growth, sector coupling, and anticipatory infrastructure planning. We therefore argue that hydrogen remains the principal strategic uncertainty in the Nordic transition, with the NGDP representing a more anticipatory planning perspective and PyPSA-Eur a more conservative least-cost timing of deployment.

0.37

A Checklist to assess the energy and carbon impacts of ML/AI applications in Earth System Modeling

cs.AI physics.ao-phcs.LG ·2026-09-01 ·Filippo Dainelli, Amirpasha Mozaffari, Marina Castaño, Aina Gaya i Àvila, Lluís Palma Garcia +3 more
similarity 0.55
Abstract · 12 pages, 1 figure, 2 tables; Submitted and presented at the GREEN-AI workshop of the ECML PKDD 2026 conference in Naples

As machine learning and artificial intelligence find their way into nearly every aspect of climate, weather, and Earth system modeling, it is worth pausing to consider what our design decisions imply for the science and for the computational resources we consume. A growing body of literature addresses the ethical and sustainable development of ML/AI, yet translating these principles into day-to-day research practice remains a challenge as most of best practices are dispersed across multiple studies and commentaries. Here, we distill these discussions into a practical checklist that ML/AI and Earth system science practitioners can use to assess and reduce the environmental footprint of their own applications, organised around the successive stages of the model development pipeline. We complement the checklist with a selection of metrics drawn from the literature for estimating the energy consumption and carbon footprint of a project. For each question, we point to concrete examples and actionable suggestions from recent literature, aiming to bridge the gap between aspirational principles and the decisions researchers face at every stage of the development cycle.

0.37

Energy and CO2 Footprint of Climate Model Intercomparison Projects

cs.CY ·2026-08-24 ·Sergi Palomas, Pablo Aparici, Gladys Utrera, Mario Acosta
similarity 0.54
Abstract · 5 pages, 2 figures. Accepted at the 2nd International Workshop on Low Carbon Computing (LOCO 2026), Lancaster University, United Kingdom, 10…

Earth System Models (ESMs) rely heavily on High-Performance Computing (HPC) resources to simulate global climate. As these models evolve, their computational demands continue to grow, driven by three factors: (1) finer spatial grid resolutions, (2) the integration of complex biogeochemical processes (e.g., atmospheric chemistry, interactive vegetation, land use, and ice sheets), and (3) larger climate ensembles to manage uncertainty. Historically, growth in peak computing performance (FLOP/s) has outpaced improvements in energy efficiency (FLOP/Watt), increasing total HPC power consumption. Despite the central role of Model Intercomparison Projects (MIPs) in climate research, quantifying their computational and environmental costs has received limited systematic attention. This paper examines the evolution of climate model carbon accounting from voluntary post-hoc estimation in the Coupled Model Intercomparison Project phase 6 (CMIP6) to standardized accounting under the newly established CMIP7 Task Team on Energy Consumption. Using high-resolution Destination Earth simulations on MareNostrum 5, we empirically evaluate how different accounting boundaries (operational, active-only, and embodied carbon) impact reported energy, carbon emissions, and financial costs. Finally, we outline key methodological considerations for standardizing energy and carbon accounting for Model Intercomparison Projects (MIPs).

0.55

A High-Resolution Synthetic EV Charging Dataset for Cold-Climate Distribution Grid Impact Analysis: Trondheim, Norway (2020-2030)

eess.SY ·2026-08-31 ·Hanieh Taraghi Nazloo, Petr Musilek
benchmark similarity 0.54
Abstract · 10 pages, 4 figures, 2 tables. Dataset available on Zenodo: DOI 10.5281/zenodo.22132618

This data article presents a high-resolution, long-term synthetic electric-vehicle (EV) charging dataset for Trondheim, Norway, spanning February 2020 to December 2030. Empirically grounded in 14 months of historical charging logs from December 2018 to January 2020, the dataset captures session-level behavioral patterns, including delivered energy, plug-in duration, connection schedules, user categorization (private vs. shared), seasonal variations, public-holiday effects, and daily ambient temperature dependencies. To model future electrification dynamics, the synthetic generation pipeline integrates historical session records, calendar and weather features from MET Norway, annual EV-adoption growth multipliers derived from Statistics Norway (SSB) registration trajectories, a daily session-count model, a Conditional Tabular Generative Adversarial Network (CTGAN), seasonal Kernel Density Estimation (KDE), and post-generation physical charger-power feasibility correction. Under a standardized 7.2 kW AC charging constraint, the resulting medium EV-adoption scenario dataset contains 76,993 hourly charging-activity records. The hourly profile is activity-based rather than a complete continuous hourly time series; hours with no allocated EV charging energy are not included. The records provide total hourly charging energy, equivalent average charging power, active session counts, private/shared user load breakdowns, ambient temperature features, and calendar indicators. The dataset provides a validated cold-climate benchmark for distribution-grid impact assessment, transformer-loading analysis, EV charging-demand forecasting, charger-capacity planning, energy-management optimization, and the development of data-driven smart-charging control strategies.

0.18

EnergyBench: a live, gate-aligned benchmark of day-ahead forecasts for European power markets

cs.LG eess.SY ·2026-11-05 ·Evgenii Genov, Ander Martinez Alonso, Christoph Bergmeir
benchmark similarity 0.54
Abstract · 21 pages, 10 figures, 7 tables. Live benchmark at https://energybench.foretec.co

Energy forecasting models are usually compared on backtests and fixed public datasets. Backtests can use data that did not yet exist when the forecast would have been made, and a fixed test set, reused across studies and possibly contained in the pretraining data of foundation models, invites overfitting to the benchmark. EnergyBench evaluates every entry live instead. Each day at 11:30 CET/CEST, thirty minutes before the day-ahead (SDAC) gate closes, every model forecasts the next day's price, wind and solar generation and load on the 15-minute grid for six bidding zones (BE, NL, FR, DE-LU, DK1, DK2). Unlike existing live benchmarks, EnergyBench runs the models itself, on one information set that it freezes at the cut-off and publishes, including three numerical weather prediction models, so that foundation models can be compared with and without the same weather covariates under the actual market deadline. Errors are pooled per series against a seasonal-naive baseline, and models are ranked by a Bradley-Terry rating on the Elo scale with a day-bootstrap interval. The field spans baselines, linear and gradient-boosted models on the frozen weather, eighteen time-series foundation models from eleven families, ensembles, and the grid operators' own forecasts. Over the first thirty-two live days, the covariates reduced the error of each of the ten foundation models run with and without them by 37-51% on matched races (64-73% on wind, 48-61% on solar). Used zero-shot, these models match or outperform a LightGBM model trained on the same covariates. Model size, from 3M to 331M parameters, has a much smaller effect, and median ensembles of the covariate models rank highest. The grid operators' pre-gate forecasts remain ahead on wind and solar, where the best single foundation models have 16-22% more error; on load the gap is 4-6%, within the intervals.

0.32

Carbon reductions through optimized solar heat gain glass properties considering future climate and grid emissions: case study of Chicago's residential buildings

cs.CE ·2026-08-14 ·Yiwei Lyu, Jialiang Xiang, Holly Samuelson
publishedhighly cited similarity 0.53
Abstract · 19 pages, 10 figures. Published in Energy and Buildings 327 (2025) 115080

Existing resources leave confusion over the benefits of high versus low Solar Heat Gain Coefficient (SHGC) windows for energy performance in residential buildings retrofits in cold climates. Additionally, few studies have considered the impact of expected future climate conditions and time-variable grid emission rates on energy-related metrics. Utilizing the ResStock, residential building stock models from the National Renewable Energy Laboratory (NREL), this study investigates retrofits increasing the SHGC of windows in Chicago, a cold US city. The results indicate that increasing window SHGC increases summer cooling needs; however, in most cases, this effect is more than offset by reduced winter heating needs. This balance is particularly beneficial considering the state's expected long-run marginal carbon emission rates. The study also examines the combined effects of high SHGC with improved window insulation values, demonstrating that such strategic window retrofits not only enhance overall building energy performance but also contribute to greater emission reductions. On average, the current Chicago residences (n = 4,826) save 4.6 % on heating and cooling carbon emissions by increasing the SHGC of the windows. If we assume that those homes are upgraded with heat pumps (electrification), a popular retrofit that reduces heating-related carbon emissions in particular, the increased window SHGC saves 2.5 % of long-run marginal carbon emissions. These results provide new insight into the carbon benefits of higher SHGC replacement windows in a cold climate. The benefits are significant, even considering future trends of a warming climate, higher demand grid emissions, and building electrification.

0.68