Carbon reductions through optimized solar heat gain glass properties considering future climate and grid emissions: case study of Chicago's residential buildings

Yiwei Lyu, Jialiang Xiang, Holly Samuelson

cs.CE ·submitted 2026-08-14 19:08 UTC · v1
publishedhighly cited

Abstract

Existing resources leave confusion over the benefits of high versus low Solar Heat Gain Coefficient (SHGC) windows for energy performance in residential buildings retrofits in cold climates. Additionally, few studies have considered the impact of expected future climate conditions and time-variable grid emission rates on energy-related metrics. Utilizing the ResStock, residential building stock models from the National Renewable Energy Laboratory (NREL), this study investigates retrofits increasing the SHGC of windows in Chicago, a cold US city. The results indicate that increasing window SHGC increases summer cooling needs; however, in most cases, this effect is more than offset by reduced winter heating needs. This balance is particularly beneficial considering the state's expected long-run marginal carbon emission rates. The study also examines the combined effects of high SHGC with improved window insulation values, demonstrating that such strategic window retrofits not only enhance overall building energy performance but also contribute to greater emission reductions. On average, the current Chicago residences (n = 4,826) save 4.6 % on heating and cooling carbon emissions by increasing the SHGC of the windows. If we assume that those homes are upgraded with heat pumps (electrification), a popular retrofit that reduces heating-related carbon emissions in particular, the increased window SHGC saves 2.5 % of long-run marginal carbon emissions. These results provide new insight into the carbon benefits of higher SHGC replacement windows in a cold climate. The benefits are significant, even considering future trends of a warming climate, higher demand grid emissions, and building electrification.

Comment
19 pages, 10 figures. Published in Energy and Buildings 327 (2025) 115080
Journal ref
Energy and Buildings 327 (2025) 115080
DOI
10.1016/j.enbuild.2024.115080

Closest papers

Nearest neighbours by meaning across the whole index.

Adjacent Heat Transfer Effects Can Bias Savings Estimates When Controlling Only Part of a Multi-Zone Building

eess.SY ·2026-11-12 ·Arash J. Khabbazi, Kevin J. Kircher
publishedtheory similarity 0.60
Abstract · 10 pages. Accepted at the 2027 ASHRAE Winter Conference

Field demonstrations of advanced heating, ventilation, and air-conditioning control often operate a few thermal zones within a larger building and report savings for those zones alone. A recent theorem showed that this practice overestimates whole-building savings, because heat drawn from the neighboring zones is paid for by their equipment and is not counted. The error grows with the thermal conductance between the controlled and uncontrolled zones, with how much colder the controlled zones run over the test, and with the price of the heat their neighbors supply. For one controlled zone with one neighbor, a single thermal price, and slowly changing prices, the relative error reduces to the ratio of two conductances, a screening number that can be evaluated from the two conductances before a demonstration begins. This paper tests how far that reduction can be taken. A two-story house with one thermal zone per floor is simulated over a 90-day heating season in West Lafayette, Indiana, with receding-horizon model predictive control on the first floor and setpoint control on the second, under four combinations of electricity tariff (time-of-use or flat) and heating plant (heat pump or electric resistance). The exact correction from the theorem recovers the true savings in every case, and the full theorem, evaluated from the controlled zone's temperatures, the prices, and the building parameters, reproduces the measured relative error in every case. The conductance ratio bounds that error from above in all four cases, tightly under a flat tariff, within 3%, and loosely under a time-of-use tariff, where most of the controller's savings come from shifting load through the thermal mass rather than from lowering the temperature.

0.30

Shading-Aware Rooftop PV Placement

cs.CE ·2026-09-19 ·Tobias von Arx, Srinivasan Keshav
code/data similarity 0.58
Abstract

Rooftop photovoltaic (PV) design requires careful panel placement to make effective use of potentially limited roof space and available sunlight. Existing simplified roof models can miss objects and superstructures that shade panels. We simulate rooftop irradiance using hourly weather and a terrain horizon, computing shadows from nearby buildings, trees, and roof superstructures rendered from the Sun's viewpoint. Our method (i) infers existing panel layouts from imagery and estimates their yield, (ii) relocates these panels to improve the yield, and (iii) generates shading-aware layouts for new installations. We compare modeled yield with production records from 11 Swiss installations and evaluate new layouts in simulation on 19 additional rural roofs. Without knowledge of any electrical or system specifications, we obtain a median daily correlation with measured production of 0.982. Absolute energy estimates remain sensitive to system specifications. Comparing new layouts with equal panel counts, accounting for neighborhood and roof-detail shading changes the position or orientation of an average of 38.9\% of panels per roof. These layouts increase modeled annual yield by up to 7.91\% compared with layouts designed without accounting for neighborhood and roof-detail shadows. We publicly release our tool for modeling and designing rooftop PV installations with terrain, neighborhood, and roof-detail shading at https://github.com/tobiasvonarx/shading-aware-pv.

0.40

Data-driven estimation of design heating loads for HVAC equipment sizing

eess.SY ·2026-09-07 ·Alex H. Lee, Elias N. Pergantis, Kevin J. Kircher
similarity 0.55
Abstract

Oversized heating and cooling equipment can unnecessarily increase up-front costs, energy costs, pollutant emissions, and strain on electrical infrastructure. This paper develops two data-driven methods for estimating heating loads at design conditions to improve equipment sizing. One method uses smart thermostat data; the other uses utility bills. We test the methods on a dataset that we gathered from 74 detached single-family houses in five United States climate zones. The dataset includes smart thermostat time-series data, monthly utility bills, weather data, existing equipment specifications, and Manual J design load calculations (the United States industry standard) purchased from practitioners. The two methods have strong goodness-of-fit statistics individually and show fair agreement with each other. On average over the 74 houses, existing heating equipment is 2.75 (2.5th to 97.5th empirical percentile: 1.34-6.52) times larger than the thermostat-method estimate and 2.96 (1.36-7.76 times larger than the bill-method estimate. As implemented by practitioners, the Manual J estimate is 2.26 (0.87-5.21) times larger on average than the thermostat-method estimate and 2.35 (1.02-5.28) times larger than the bill-method estimate. We discuss prospects for implementing the data-driven methods at scale and for incorporating data-driven sizing into industry standards.

0.26

Exploiting the Benefits of V2B Application on Peak Shaving of Data Center Loads

eess.SY ·2026-08-31 ·Arya Joshi, Hamed Haggi, Chinmay Morankar
similarity 0.54
Abstract · Digest submission version for IEEE IAS Annual Meeting 2026

The accelerated growth in data center projects has introduced a demand-driven bottleneck throughout power grids and contributed to a substantial increase in carbon emissions. These concerns are fueling discussions on methods to use existing energy assets to drive operational efficiency. To this end, this paper explores the benefits of Vehicle-to-Building (V2B) applications to support peak shaving of data center cooling loads. Initially, a literature review was conducted considering V2B constraints and optimization methods including SoC limitations, EV participation, tariffs, and building loads. This analysis was then used to develop a conceptual case study of a 10 MW data center in Loudoun County, VA by simulating a temperature-dependent load profile and adjusting the V2B participation of 40 commercial and passenger EVs. Simulation results indicate that, depending on seasonal variations in cooling load demands, strategic deployment of V2B assets between 12-5pm can offset gross cooling loads by 13-36%.

0.17

Reassessing Clean Power 2030 Pathway Using Real Time Records

eess.SY ·2026-10-19 ·Anthony D Stephens, David R Walwyn
similarity 0.53
Abstract · 18 pages, 8 tables, 5 figures

The National Energy System Operator (NESO) Clean Power 2030 advice to the government, accepted as United Kingdom (UK) government policy in December 2024, outlines a rapid increase in wind and solar generation capacities with the associated infrastructure by 2030, with the objective of reducing carbon dioxide emissions from the UK electricity system to 5.2 million tons per annum. Our previous paper used real-time records from 2017 to analyze Clean Power 2030 proposal. This paper extends the previous assessment, using real time records of 2017, 2018 and 2019 to test the resilience of the UK energy system under more diverse weather patterns. Two different modelling methods predict that the 2030 carbon dioxide emissions will be five times greater than Clean Power 2030 prediction. Furthermore, the projections show that, due to increased curtailment, only about half of NESO proposed increases in wind and solar capacities will be economically justified. NESO also advised the government that 35GW of unabated gas-fired generation would maintain security of supply, whereas our models suggest that at least 42 GW will be required during winter wind lulls. Recent events, such as grid stability problems in 2026, also discussed in the paper, validate our estimated and suggest the risk of blackouts in the UK is increasing.

0.27

Which wind and solar modelling choices matter? Effects on capacity factors, energy droughts and European power system configuration

eess.SY ·2026-10-29 ·L. Karkossa, A. Grochowicz, M. J. Koivisto, A. Hahmann, M. VIctoria
similarity 0.53
Abstract

Europe's future power system will rely heavily on wind and solar power and must remain resilient during prolonged periods of low wind and solar generation, known as variable renewable energy (VRE) droughts. To capture such rare events, adequacy assessments increasingly draw on decades of weather data, but the conversion of weather into power is largely treated as fixed. It remains unclear which modelling choices in this conversion matter for representing these droughts, and whether they matter as much as the weather itself. Here we systematically compare these choices side by side (bias correction, wind speed extrapolation, capacity layouts, turbine and photovoltaic configurations, and wake losses) and trace their effects through VRE droughts to the design of a net-zero European power system, using 85 years of reanalysis data. We find that modelling choices barely change how often VRE droughts occur or when the system is stressed. They do, however, determine how much capacity is needed to withstand that stress. By altering the electricity delivered during droughts, they shift required capacity by up to 480 GW, which is comparable to the spread across the most critical weather years. Modelling exercises should therefore use multiple weather years; bias-correct and regionally validate weather inputs; explicitly represent resource heterogeneity, forward-looking technologies, and wake losses; and judge these choices by their effect on the low-generation tail, not only on the mean.

0.24

AgentHomeID - Agent-based modelling of building stock transformation: A multi-scale framework for policy assessment and infrastructure planning

eess.SY ·2026-09-04 ·Helen Ganal, Sarah Becker, Sascha Holzhauer, Thilo Glißmann, Friedrich Krebs +2 more
similarity 0.53
Abstract · Submitted to Applied Energy

Decarbonising the building sector is central to meeting climate targets, yet existing models rarely capture the interaction between system-level transformation dynamics and heterogeneous individual investment decisions. This work presents AgentHomeID, an agent-based model of building stock evolution in which owner behaviour, techno-economic constraints, and regulatory frameworks are represented explicitly at the level of individual buildings and their owners. The model differentiates owner-occupiers, private landlords, and institutional owners, using willingness-to-pay (WTP) parameters estimated from empirical decision-maker studies, and operates on both representative building archetypes and real building data derived from geographic information systems (GIS). We demonstrate this versatility across three applications. At national scale, scenario analysis for Germany to 2045 shows that removing binding renewable heating requirements substantially raises final energy demand even where envelope refurbishment is unchanged, and that subsidy allocation and investment activity diverge sharply across owner types and income quartiles, with the lowest quartiles persistently underinvesting. At regional scale, bottom-up simulation for a German distribution grid planning region yields spatially concentrated heat pump uptake at NUTS-3 level that differs from aggregated top-down projections in both magnitude and spatial distribution. At urban block level, the same simulations resolve substation-level load heterogeneity and show that integrated system peaks driven by heat pumps, electric vehicles, and photovoltaics do not coincide with individual technology peaks. Across all three scales, owner heterogeneity and local structure materially shape transition pathways, indicating that they should be represented explicitly in models used for policy assessment and infrastructure planning.

0.26

Impact of Wind-Solar-Battery Growth on Electricity Prices: Reserve Scarcity and Transmission Congestion

eess.SY ·2026-11-14 ·Haoxiang Wan, Ivan Castillo, Xingpeng Li
similarity 0.51
Abstract · 7 pages, 3 figures, 2 tables. Submitted to IEEE GECA 2027

This paper asks whether sequential wind, solar, and battery storage additions that eliminate unserved energy also remove modeled reserve scarcity and transmission congestion. Thirty-one cumulative portfolio states are evaluated on a modified IEEE 24-bus system for a constructed stressed day using a 24-hour day-ahead unit commitment model with network constraints, co-optimized energy and upward reserve, chronological battery storage, and an approximation of the Electric Reliability Council of Texas operating reserve demand curve. The thermal baseline has 106 MWh of unserved energy, whereas 450 MW of wind is sufficient to serve all demand. However, with 1,500 MW of wind, the hourly modeled reserve scarcity price still reaches \$5,000/MWh because wind output declines after the system peak. Adding 1,800 MW of solar reduces the load weighted daily average modeled reserve scarcity price from \$1,136.2/MWh to \$101.2/MWh and confines modeled reserve scarcity to three evening hours. Adding 250 MW/1,000 MWh of battery storage further lowers the average to \$4.3/MWh and reduces wind curtailment from 631 MWh to 306 MWh. Transmission congestion nevertheless remains: all residual wind curtailment occurs at bus 21, wind capture prices at buses 21 and 23 differ by \$31.8/MWh, and identical battery storage plants yield normalized net energy market revenues of \$201/(MW$\cdot$day) and \$121/(MW$\cdot$day) at buses 19 and 21, respectively. These results show that unserved energy, modeled reserve scarcity, and locational congestion effects measure distinct operating conditions and should be evaluated separately but interpreted together.

0.27