CS Paper Radar

PiMiX 2.02: Toward AI-Driven Data Fusion in Radiographic Imaging and Tomography

Zhehui Wang, Shanny Lin, Nicholas Amano, Ramya Gurunathan, Katie Liu, Nathan E. Peterson, Michelle A. Espy, Adam Thompson, Amy J. Clarke, Ray T. Chen

eess.IV physics.data-an ·submitted 2026-09-11 15:55 UTC · v1

Abstract

PiMiX (Physics-informed Meta-instrument for eXperiments) was introduced for multi-instrument, multi-experiment, and simulation-experiment data fusion in radiographic imaging and tomography (RadIT). Here we present PiMiX 2.02 as an evolving AI-enhanced cyber-physical meta-instrument integrating imaging sensors, near-sensor computing, data fusion, physics-informed inference, and human-supervised AI workflows across X-ray, neutron, and other modalities. Demonstrated capabilities include multimodal CMOS radiation imaging, simulation-assisted sub-pixel neutron localization, and edge-deployed optical-neural-network (ONN) inference; GPU and ONN implementations achieved greater than 96% precision for neutron-event detection with sub-micron localization. A further advance is human-in-the-loop agentic-AI co-analysis of X-ray and neutron images from inertial-confinement-fusion experiments. Beyond conventional preprocessing, the workflow generates competing feature hypotheses, ranks contours using physics-informed evidence, estimates confidence, and presents alternatives for human review. The same architecture adapts to different physics: X-ray analysis emphasizes dark, nonuniform ring structures using deformable closed paths and multi-scale evidence, whereas neutron analysis targets bright emission envelopes using fractional-emission levels, intensity gradients, and cross-filter persistence. We also highlight automated comparison of an as-designed stereolithography model with an X-ray CT reconstruction of an additively manufactured metal lattice. Together, these examples show progression from AI assistance in specific processing tasks to multi-task, multi-domain scientific co-analysis. PiMiX 2.0 further provides a pathway toward PRISM, a RadIT scientific foundation model, and tighter integration of diagnostics, digital representations, inference, and experimental control.

Comment
12 pages, 5 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Compositional neural networks for multimodal X-ray and neutron scattering inversion

cs.LG cond-mat.mtrl-sciphysics.app-ph ·2026-10-21 ·Valentin Munteanu, Alexander Hinderhofer, Dmitry Lapkin, Vladimir Starostin, Frank Schreiber
similarity 0.62
Abstract

X-ray and neutron scattering are indispensable for structural characterization across condensed-matter physics and materials science. Yet, because scattering experiments generally record intensities without phase information, distinct structures can yield similar scattering patterns, rendering the corresponding inverse problems non-unique. This ambiguity can be reduced by combining complementary measurements, but their integration into machine-learning frameworks remains challenging. Here we introduce a modular framework for probabilistic multi-measurement analysis based on prior-amortized flow matching. Single-observation posterior estimators are trained separately for individual observation types or physical probes and combined only at inference time through a compositional sampler. This late fusion approach allows pretrained single-observation models to be reused without dedicated joint retraining. As a case in point, we consider reflectometry, which provides depth-resolved, nanometer-scale information about thin films and interfaces. Our single-observation demonstrations span X-ray, time-of-flight neutron and polarized neutron reflectometry. In separate co-refinement studies, task-matched estimators enable homogeneous composition across multiple neutron contrasts and heterogeneous multimodal composition of X-ray and neutron measurements. Together, these results establish compositional flow matching as a modular approach to uncertainty-aware inversion and co-refinement, with potential applicability to other scattering problems in which multiple observations constrain a common physical structure while retaining measurement-specific parameters.

0.27

BEACON: A Versatile Accelerator for Computational Pathology Applications

cs.AR ·2026-09-10 ·Sumanth Gudaparthi, Ananth Krishna Prasad, Lin Jia, Rajeev Balasubramonian, Srinivasan Parthasarathy
similarity 0.56
Abstract

While accelerators for AI have seen great commercial success, it is challenging to replicate that success for other specialized domains due to a number of factors. We make the case that barriers for new accelerators can be lowered by starting with a baseline AI accelerator, and adding minimal logic to support new operators demanded by new specialized domains. This leads to a versatile chip that can be manufactured at high volume and deployed for a range of popular applications. We refer to this as the AI+X approach. This paper explores its potential for the emerging domain of Computational Pathology, which involves analysis of large whole-slide tissue images with a multi-stage pipeline. The pipeline requires support for a number of different kernels and operators - early stages perform segmentation and feature extraction, followed by graph creation with k nearest neighbor (kNN) algorithms, and finally inference with an iterative graph convolutional network (GCN) that alternates between Aggregation and Combination. We show that these stages execute inefficiently on a range of baseline CPU, GPU, AI, and GCN accelerators. That inefficiency is addressed with a combination of software re-structuring and small modifications to a baseline systolic AI accelerator. Many of the above kernels can be mapped to a systolic accelerator by offering a flexible datapath between processing elements and register access mechanisms. We add support for feature aggregation, load balanced execution, Euclidean distance calculation, binning, and counter aggregation. This additional flexibility and logic grows the area of a baseline AI chiplet by 1.1x, but by avoiding the memory wall and offering high parallelism, the proposed accelerator BEACON yields over an order of magnitude higher throughput for Computational Pathology than baseline CPU and GPU platforms.

0.11

Agentic AI for operating scientific instruments for nanoscale characterization

cs.AI physics.ins-det ·2026-08-25 ·Zahra Ayar, Marcos Penedo, Mahdi Mehdikhani, Nahid Hosseini, Prabhu Prasad Swain +1 more
similarity 0.56
Abstract

Operating a scientific instrument such as an atomic force microscope (AFM) requires continuous expert decision-making. A trained user defines the experimental intent, translates it into instrument commands, assesses incoming data, adjusts imaging parameters, and post-processes the final image. Existing automation usually addresses only parts of this workflow through hard-coded routines, task-specific controllers, or trained machine-learning models. Here we present an agentic-AI framework that operates the executable part of the AFM workflow using a general-purpose, tool-augmented large language model connected to instrument functions through the Model Context Protocol (MCP). The framework consists of 3 MCP-based agents: AFM Messenger converts natural-language instructions into checked instrument commands; AFM Pilot assesses image quality through a large language model (LLM) and, if necessary, adapts imaging parameters; and AFM Doctor diagnoses image artifacts and applies transparent post-processing from a pre-approved tool set. Because the language model performs image assessment rather than a fixed scalar objective or external optimizer, the same strategy can be applied across sample types and imaging modes without specific retraining. Safe hardware operation is enforced through an ambiguity check layer before execution. Benchmarking against fine-tuned and off-the-shelf tool-using models shows that this guarded execution layer, rather than model capability alone, reduces wrong-command execution to zero. In live experiments on different samples, AFM Pilot matched expert operators in image quality, iteration count, and tuning time, with no significant difference. These results demonstrate a safe route to agentic operation of scientific instruments, where experimental intent remains human-defined while command execution, image-based tuning, and post-processing are delegated to AI agents.

0.34

Improved CNN-Transformer Network for Neutron Image Super-Resolution

cs.CV ·2026-11-12 ·Yuheng Chu, Hongli Li, Tian Zhang
unusual similarity 0.55
Abstract · 11 pages, 5 figures, 3 tables

The spatial resolution of neutron images is of great importance for material defect diagnosis, structural characterization, and nondestructive testing. However, owing to limitations in neutron beam quality, scintillator conversion efficiency and light scattering, detector pixel size, and noise levels, conventional neutron images often suffer from speckle noise, blurred edges, and missing details, making them inadequate for high-precision analysis. To address these issues, an improved super-resolution model combining convolutional neural networks (CNNs) and Transformers is proposed. First, to overcome the difficulty of obtaining high-quality and clear training images for neutron imaging, a pretrained image restoration model is fine-tuned using real neutron images and then employed to enhance existing neutron images, thereby providing high-quality reference images for subsequent super-resolution model training. Second, an improved CRAFT-based super-resolution network is developed by incorporating a hybrid prior-guided channel fusion module (HPCF), a mean-standard deviation dual-statistics squeeze-and-excitation block (MS-SEBlock), and a partial convolution feed-forward network (PCFN), with the aim of improving the reconstruction of important information, such as textures and fine details, in neutron images. Simulation results demonstrate that, compared with bicubic interpolation, SRCNN, SRGAN-VGG, and other methods, the proposed network achieves superior performance in both full-reference metrics, including PSNR and SSIM, and no-reference metrics, including AGM and SMD. The visual quality and structural fidelity of the reconstructed images are also significantly improved. This study provides a new approach to improving neutron image quality.

0.27

Pre-training, Reasoning, Benchmarking: X-ray Report Generation on CheXpert Plus Dataset

cs.CV cs.AI ·2026-09-23 ·Xiao Wang, Yuxiang Zhang, Dan Xu, Yuehang Li, Shiao Wang +4 more
benchmarkcode/data similarity 0.55
Abstract

X-ray image-based Radiology Report Generation (RRG) constitutes a critical research direction within medical artificial intelligence, with great potential to alleviate clinicians' diagnostic workload and shorten patient waiting periods. Despite substantial advances over recent years, the field faces evident bottlenecks stemming from insufficient standardized benchmarks and inadequate domain adaptation of generic large models. Notably, the newly released CheXpert Plus dataset is provided without accompanying baseline implementations and evaluation results, which impedes standardized training, quantitative evaluation and fair comparison among follow-up algorithms. To mitigate this limitation, we establish a comprehensive benchmark encompassing prevailing X-ray report generation models and Large Language Models on CheXpert Plus. This benchmark delivers a reliable comparative foundation for upcoming methods and enables researchers to rapidly identify state-of-the-art approaches within this domain. Beyond benchmark construction, we rethink X-ray RRG under the paradigm of large models and propose a novel framework termed MambaXray-PRB. Our framework improves report generation performance and enhances model interpretability via multi-stage large-model pre-training and multi-modal Chain-of-Thought reasoning. The pipeline consists of three successive phases: self-supervised auto-regressive modeling, X-ray-report contrastive learning, and post-training optimization for reasoning and report generation. Extensive experiments on IU X-ray, MIMIC-CXR, and CheXpert Plus datasets validate the effectiveness of MambaXray-PRB for radiology report generation. The source code of this paper is available on https://github.com/Event-AHU/Medical_Image_Analysis

0.32

AI-Enhanced Radiation Classification in ROS

cs.RO ·2026-10-18 ·Youngseo Lee, Cesar Alan Contreras, Tianshu Ruan, Manolis Chiou, Rustam Stolkin
similarity 0.53
Abstract · 7 pages, 4 figures, 3 tables

This study presents the development of two Robot Operating System (ROS) nodes with a primary focus on differentiating seven radioactive isotopes. The first node, referred to as the model training node, uses a Gradient Boosting classifier to identify and classify these isotopes. The classifier achieved a reported overall accuracy of 95\% on the held-out test dataset. The second node, known as the prediction node, provides classification results when users input data in CSV format. For the practical demonstration, the C12137 radiation detector module was mounted on the Jackal UGV, and an operator approached different radiation sources to collect data. To support future dataset expansion, we also developed a method for converting gamma-spectrum graph images into CSV files. In a separate robotic evaluation across three source locations, 30 of 42 trials were correctly classified (71.43\%). Am-241, Co-60, Cs-137, Na-22, and Ti-44 were correctly classified in all six trials each, whereas Ba-133 and Eu-152 were incorrectly classified in all six trials each. These results show lower accuracy in robotic trials than in the held-out test set.

0.25

FleXray: Universal Clinical X-ray Segmentation

cs.CV cs.AI ·2026-09-22 ·Victor Ion Butoi, Vivek Gopalakrishnan, John V. Guttag, Adrian V. Dalca, Neel Dey
similarity 0.52
Abstract · 35 pages, 12 figures, 10 tables. Code, models, data, and a browser-based demo at https://flexray.csail.mit.edu

X-ray is medicine's most widely used imaging modality, yet remains among its least quantitative. Unlike volumetric modalities like CT or MRI, X-ray collapses 3D anatomy into a 2D projection, causing structures to overlap and anatomical boundaries to be ambiguous, even to experts. As a result, labeling X-ray databases for training general-purpose segmentation systems is impractical, leaving morphometric and functional X-ray analysis confined to narrow anatomical regions and applications. To this end, we present FleXray, a generalist model for anatomical segmentation across the entire body in clinical X-rays. Instead of curating large, manually annotated X-ray datasets, we build a scalable, physics-based generative X-ray data engine. Using existing 3D whole-body CT segmentation datasets and generative image-editing models, we simulate fully-annotated 2D X-rays with diverse appearances, physiological properties, and imaging geometries. Trained on these simulations, FleXray accurately segments 60 anatomical structures across unseen research datasets and in-the-wild X-rays. We further show that FleXray makes X-rays directly amenable to quantitative analysis, enabling automated measurements for disease grading, robust navigation during X-ray-guided interventions, and data-efficient learning of pathological targets. We release the model, code, a full-body X-ray segmentation dataset, and a local, easy-to-use browser-based tool at https://flexray.csail.mit.edu .

0.27

nnFoundation: 3D Foundation Models for Radiology

cs.CV eess.IV ·2026-09-22 ·Constantin Ulrich Harsy, Tassilo Wald, Karol Gotkowski, Yannick Kirchhoff, Marcel Knopp +78 more
similarity 0.52
Abstract

Radiological artificial intelligence has advanced rapidly, yet most systems remain narrowly task-specific, data-intensive, and fragile under domain shift. Foundation models promise more transferable and data-efficient solutions, but existing approaches are limited in scale, evaluated narrowly, and often assume that a single pretrained model can support diverse downstream tasks. Here we present nnFoundation, complementary convolutional and transformer-based 3D radiological foundation models. Developed within the Human Radiome Project (THRP), nnFoundation is trained on 2.1 million CT, MRI, and PET image volumes from 125 institutional and public datasets. We evaluate them across 108 tasks spanning segmentation, detection, classification, report generation, and image retrieval, including evaluations under domain shift, by external partners and in low-data and low-compute regimes. Across all task types, our convolution- and transformer-based nnFoundation models consistently outperform both prior 3D foundation models and training from scratch, establishing state-of-the-art performance for radiological imaging. However, performance follows a consistent task-dependent structure: the convolutional nnFoundation model dominates spatially localized tasks, whereas the transformer-based nnFoundation model excels in tasks requiring global semantic reasoning and in frozen-feature settings. Dynamically aligning the foundation model topology with the dataset characteristics post-hoc further improves transfer across heterogeneous 3D settings. These results show that transferable 3D radiological performance is governed not by a single universal model, but by the interplay of scalable pretraining, complementary architectures, and dataset-aware adaptation. We release nnFoundation models integrated into nnU-Net and nnDetection, enabling immediate application across established radiology workflows.

0.40