CS Paper Radar

Automated Distinction of Intimal and Medial Intracranial Arterial Calcification from CT Head

Benjamin Jin, Maria del C. Valdés Hernández, Richard Bortsov, Joanna M. Wardlaw, Daniel Bos, Grant Mair

eess.IV cs.CV ·submitted 2026-09-11 10:19 UTC · v2
publishedcode/data

Abstract

Intracranial arterial calcifications (IACs) are a common finding on clinical non-contrast enhanced head CT scans and are associated with neurovascular disease. Calcifications can occur in the intimal or medial layer of the arterial wall, subtypes that differ in aetiology and may have distinct clinical relevance. These subtypes can be visually distinguished by radiologists based on the shape of the calcifications. We investigate three automated approaches for subtype classification of IAC from head CT-derived segmentation masks: (1) an automated adaptation of the established radiological visual score, (2) a sphericity-based method, and (3) a method based on shape embeddings extracted by a medical shape foundation model. All approaches use the same lightweight classification pipeline on top of the features they compute and are evaluated using 5-fold cross-validation. The three methods achieved comparable performance, with the embedding-based approach yielding the best overall results with a weighted F1 (mean $\pm$ SD) of up to 71.5 $\pm$ 3.7 for a single artery and 59.8 $\pm$ 1.7 for the joint artery classification. Performance was largely preserved when using automated instead of manual IAC segmentation masks, and we found the difference in weighted F1 not significant. Our results show that fully automated IAC subtype quantification from head CT is feasible and remains robust to the use of manual and automated IAC segmentation masks. Code at https://github.com/bjin96/iac-subtyping.

Comment
Accepted at the Stroke and neurovascular diseases Workshop on Imaging and Treatment CHallenges @ MICCAI 2026

Closest papers

Nearest neighbours by meaning across the whole index.

An Anatomy-Aware Staged Pipeline for Vessel-Specific Intracranial Aneurysm Segmentation in CT and MR Angiography

eess.IV cs.CV ·2026-10-15 ·Gniewosz Drwiega, Wojciech Szymanski, Marek Wodzinski
published similarity 0.64
Abstract · Submitted version (7 August 2026) of a paper accepted at SWITCH+ 2026, a MICCAI 2026 workshop (TopAneu 2026 challenge track). Table 1 entrie…

The TopAneu 2026 challenge requires intracranial aneurysms to be segmented at the voxel level and assigned to one of more than fifty vessel-specific classes, on CT and MR angiography alike. We address it with a six-stage anatomy-aware pipeline rather than a single segmentation network. A logistic-regression classifier routes each scan to a modality-specific branch; networks segment the vasculature, first as a binary mask and then over the full 36-class arterial taxonomy; a candidate localiser turns raw angiography and vessel priors into suspicious regions; a candidate-centred network segments the lesion in each crop; connected components become instances; and a per-instance classifier assigns each its anatomical location. Two principles organise the design. Whenever an upstream model output becomes a downstream training input it is generated out-of-fold, so no stage trains on unrealistically clean predictions of itself. And the anatomical decision is made once per lesion rather than once per voxel, which fits the data: of 406 connected aneurysm components in the full release, 405 carry exactly one location label. Task 1 is read off the Task 2 mask, making the two consistent by construction. We report stage-wise performance and a five-part ablation isolating what vessel priors and class-aware sampling contribute at each stage.

0.24

Synthetic training for long-tail haemorrhagic lesion segmentation in data-scarce settings

cs.CV ·2026-10-01 ·Yuan Cao, Sumeet Dash, Antonia Zachariadis, Stefanie Schreiber, Katja Neumann +1 more
published similarity 0.62
Abstract · Accepted: MICCAI 2026 SASHIMI workshop

Cerebral microbleeds (CMBs) and cortical superficial siderosis (cSS) are imaging markers of cerebral small vessel disease, but their automated segmentation is limited by the scarcity of positive cases and voxel-level annotations. We propose a synthetic training framework for long-tail haemorrhagic lesion segmentation that requires no real lesion annotations for training and leverages radiological description of the lesions. Starting from anatomical brain parcellations, the framework applies spatial augmentation and voxel resampling, procedurally inserts cSS and CMB labels using clinical priors on lesion location and morphology, and synthesises images through randomised intensity assignment, blurring, and Rician noise simulation. Models were trained on dynamically generated image-label pairs and evaluated against manual delineations in 10 cSS cases and 13 CMB cases. The proposed configurations outperformed classical filter baselines. For cSS, the hypointensity constrained model achieved higher AUPRC and AUROC than the Frangi filter (AUPRC: 0.284 vs 0.083; AUROC: 0.907 vs 0.731). For CMBs, explicit synthesis of blood vessels as lesion mimics improved performance over the classical baseline (AUPRC: 0.538 vs 0.004; AUROC: 0.999 vs 0.968). These results support our proposal as a feasible strategy for data-scarce haemorrhagic lesion segmentation.

0.39

ImageCAS-X: a dataset and benchmark for coronary artery segmentation and centerline extraction in coronary CT angiography

cs.CV cs.AI ·2026-08-31 ·Kit M. Bransby, Esther Øksnebjerg, Kristoffer Kjær, Jacob Kirkeby, Yasmin El Youssef +5 more
benchmarkdataset similarity 0.58
Abstract · Pre-print (under review)

Accurate segmentation of the coronary vessel lumen is a prerequisite for quantitative assessment of atherosclerotic plaque and perivascular adipose tissue in coronary computed tomography angiography (CCTA). Cardiologists rely on semi-automated methods for this task because manual vessel tracing and segmentation are labour-intensive. Although many automated methods have been proposed, their validation remains limited by the lack of large, high-quality publicly available datasets. We provide a new dataset of voxel-wise annotations of the vessel lumen and coronary segments, alongside centerlines, and mesh surfaces for 800 scans from the publicly available ImageCAS dataset. Using this dataset, we benchmark established lumen segmentation methods against inter-observer variability, stratifying performance by disease, image quality, coronary dominance, coronary segment, vessel diameter, and lumen attenuation. These labels allow segmentation accuracy to be described in anatomical and clinical context rather than reported as a single aggregate score. The dataset supports the development and validation of methods for lumen segmentation, plaque and perivascular quantification, and haemodynamic modelling.

0.40

FD-AA: A Lightweight Focal-Diffuse And Attenuation-Aware Head for Incidental Abdominal Abnormality Detection in Chest CT

cs.CV ·2026-09-28 ·Haoyan Ding, Kritika Iyer, Halid Yerebakan, Zhenyu Bu, Chushu Shen +7 more
similarity 0.58
Abstract · Submitted to a conference

Routine chest CT captures upper-abdominal structures that may contain clinically relevant incidental abnormalities. Detecting these findings requires feature extraction from organs with different spatial extents and attenuation patterns. We propose FD-AA, a lightweight organ-aware classification head adaptable for frozen 3-D CT encoders. Within each organ, an attenuation-aware module preserves sparse focal evidence, while masked generalized-mean pooling captures diffuse anomaly patterns. In seven abdominal organs, FD-AA with Pillar-0 achieved state-of-the-art (SOTA) performance in both the CT-RATE test set (AUC = 0.798) and the external RAD-ChestCT dataset (AUC = 0.713). More specifically, FD-AA improved macro AUC/AP from 0.763/0.346 to 0.798/0.405 over direct classification using frozen Pillar-0 only (p = 0.034/0.016). Such performance gain generalizes across multiple frozen encoders (AUC improvement on MedicalNet +9.8%, CT-CLIP +14.7%, ResNet +3.7%), demonstrating the effectiveness of FD-AA across different feature representations. These results support the effectiveness of integrating focal-diffuse aggregation with explicit HU evidence for incidental abdominal abnormality detection.

0.20

MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation

cs.CV cs.AI ·2026-10-02 ·Jiaying Li, Paolo Remagnino
top venue similarity 0.58
Abstract

Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

0.32

A Neighborhood Attention Transformer Network for Enhanced 3D Segmentation of the Left Anterior Descending Artery

cs.CV cs.AI ·2026-08-12 ·Rafi Ibn Sultan, Chengyin Li, Yiannos Demetriou, Ahmed I. Ghanem, Joshua P. Kim +4 more
published similarity 0.57
Abstract · Acceteed by Medical Physics 2026

Background: Accurate segmentation of the Left Anterior Descending (LAD) artery in 3D free-breathing, non-contrast CT is critical for cardiac dose sparing in thoracic radiotherapy. The LAD is extremely small, has poor soft-tissue contrast, and varies substantially across patients; even manual contours show limited inter-observer agreement, underscoring the ambiguity of the vessel boundaries. Purpose: To develop a transformer-based framework that improves LAD delineation in low-contrast, imbalanced CT through local-global context modeling and uncertainty-guided optimization. Methods: We propose NA-UNETR, a 3D transformer-based segmentation model whose Neighborhood Attention (NA) and Dilated NA (DiNA) blocks jointly capture fine structural detail and long-range context. Given the scarcity of annotated LAD data, the model is pretrained on 1,000 CTA volumes of general coronary anatomy and fine-tuned with LoRA-based parameter-efficient adaptation on 20 free-breathing institutional CT scans. A composite Dice-Focal and Hausdorff loss, dynamically balanced via homoscedastic uncertainty, improves overlap and boundary accuracy. Results: NA-UNETR reached 45.64% Dice, 38.16 mm HD95, and 10.01 mm ASD, improving Dice by 3.10 percentage points over nnU-Net and reducing HD95 by 2.96 mm relative to Swin UNETR, with the strongest boundary accuracy among all models and improved centerline stability. On ImageCAS it achieved 79.49% Dice, 8.89 mm HD95, and 1.02 mm ASD. Ablations confirmed that residual blocks, variable kernels, and uncertainty-weighted loss each contributed. Conclusions: NA-UNETR balances local precision and global context for thin, low-contrast LAD structures, offering a computationally efficient framework for substructure-level cardiac segmentation in radiotherapy planning.

0.52

AsymFeX: A Symmetry-Driven Framework for Ischemic Stroke Segmentation Across Imaging Modalities and Stroke Stages

eess.IV cs.CV ·2026-08-20 ·Maunil Shah, Vaanathi Sundaresan
code/data similarity 0.57
Abstract

Fast and accurate segmentation of Acute Ischemic Stroke (AIS) lesions is essential for stroke prognosis and treatment planning. Non-contrast CT (NCCT), the first-line imaging modality for diagnosing ischemic infarcts, exhibits subtle infarct contrast, making manual delineation slow and labor-intensive. Motivated by this, and by the clinical practice of comparing brain hemispheres to localize infarcts, we propose a two-stage, nnU-Net-compatible 3D segmentation method. The first stage corrects head tilt to align each scan to its true anatomical mid-sagittal plane; the second applies a novel Asymmetric Feature Extraction (AsymFeX) module, comparing each voxel to its true contralateral counterpart within a local 3 x 3 x 3 neighborhood via cross-hemispheric attention, feature disparity estimation, and dual-scale gating to capture both large and small infarcts. On AISD, our method achieves 0.6796 Dice, 23.53 mm HD95, and 7.69 mL AVD, significantly outperforming existing state-of-the-art methods, with clinically relevant volumetric analysis at the 70 mL thrombolysis-eligibility threshold. Proof-of-concept evaluation on ATLAS v2.1 and ISLES'24 demonstrates that the same symmetry-driven design generalizes across imaging modalities and stroke time points without architectural changes, further supported by an uncertainty analysis assessing reliability under clinical deployment. Code is publicly available at https://github.com/biomedia-lab/AIS-detection.

0.23

Improving Cross-Site Whole-Heart Segmentation

eess.IV cs.CV ·2026-08-25 ·Tanish Mudaliar, Justin Li, Daniel Lin, Julianna Vo, Kaitao Liao +2 more
publishedcode/data similarity 0.57
Abstract · 12 pages, 2 figures. Accepted to the MICCAI 2026 for the CARE Whole Heart Segmentation Challenge proceedings

Whole-heart segmentation from CT and MRI is essential for quantitative cardiac image analysis, but remains challenging under multi-center and multi-modality distribution shift. In the CARE whole-heart segmentation task, models must generalize from limited labeled sites to unseen acquisition distributions, where variation in spacing, intensity, reconstruction texture, and anatomy can degrade out-of-distribution performance. We propose a modality-routed 3D cardiac segmentation pipeline that combines TotalSegmentator-initialized nnU-Netv2 models with site-characterized, label-preserving appearance augmentation. We first characterize the available sites using measurable image properties and use this analysis to motivate candidate data-space generalization routes. The final retained recipe applies Bias Field + Bezier appearance augmentation, combining smooth spatial intensity perturbation with nonlinear intensity remapping, followed by lightweight class-wise largest-connected-component cleanup. On the primary held-out-site validation splits, the final configuration improves CT mean Dice from 0.8350 to 0.9135 and MRI mean Dice from 0.7695 to 0.7830, while also reducing HD95. These results suggest that site-motivated appearance augmentation is a practical strategy for improving cross-site robustness in limited-data whole-heart segmentation. Our code can be found in https://github.com/Purdue-M2/Improving-Cross-Site-Whole-Heart-Segmentation

0.51