CS Paper Radar

FD-AA: A Lightweight Focal-Diffuse And Attenuation-Aware Head for Incidental Abdominal Abnormality Detection in Chest CT

Haoyan Ding, Kritika Iyer, Halid Yerebakan, Zhenyu Bu, Chushu Shen, Peiyu Duan, Xinyuan Zheng, Sepehr Farhand, Xueqi Guo, Chaowei Wu, Yoshihisa Shinagawa, Gerardo Hermosillo Valadez

cs.CV ·submitted 2026-09-28 19:54 UTC · v1

Abstract

Routine chest CT captures upper-abdominal structures that may contain clinically relevant incidental abnormalities. Detecting these findings requires feature extraction from organs with different spatial extents and attenuation patterns. We propose FD-AA, a lightweight organ-aware classification head adaptable for frozen 3-D CT encoders. Within each organ, an attenuation-aware module preserves sparse focal evidence, while masked generalized-mean pooling captures diffuse anomaly patterns. In seven abdominal organs, FD-AA with Pillar-0 achieved state-of-the-art (SOTA) performance in both the CT-RATE test set (AUC = 0.798) and the external RAD-ChestCT dataset (AUC = 0.713). More specifically, FD-AA improved macro AUC/AP from 0.763/0.346 to 0.798/0.405 over direct classification using frozen Pillar-0 only (p = 0.034/0.016). Such performance gain generalizes across multiple frozen encoders (AUC improvement on MedicalNet +9.8%, CT-CLIP +14.7%, ResNet +3.7%), demonstrating the effectiveness of FD-AA across different feature representations. These results support the effectiveness of integrating focal-diffuse aggregation with explicit HU evidence for incidental abdominal abnormality detection.

Comment
Submitted to a conference

Closest papers

Nearest neighbours by meaning across the whole index.

Beyond Accuracy: Quantifying Pulmonary Attribution in Anatomy-Guided Chest X-Ray Classification Under Domain Shift

cs.CV ·2026-08-31 ·Abdullah Al Mamun, Md. Nasif Osman Khansur, Md Ashraful Hossen Akash, Md. Kishor Morol, Tze Hui Liew
code/data similarity 0.65
Abstract · 34 pages, 8 figures, 7 tables. Code available at https://github.com/Abdullah-229/BeyondAccuracy

Deep-learning models can achieve strong chest X-ray (CXR) classification performance without establishing whether their predictions predominantly rely on pulmonary image content. This study evaluates pulmonary attribution containment as an anatomy-related reliability property distinct from diagnostic performance. We propose DBCA-SegNet-MGAP, a multi-task anatomy-guided CNN-Transformer framework that combines complementary feature representations through bidirectional cross-backbone attention, predicts a soft lung mask, and incorporates this anatomical prior directly into classification through Mask-Guided Adaptive Global Average Pooling (MGAP). Pulmonary attribution containment is quantified using the Anatomical Local Energy Ratio (ALR) and high-intensity cumulative ALR (cALR@0.9). Experiments were repeated across three training seeds using the COVID-19 Radiography Database for four-class internal testing and a locked Shenzhen-to-Montgomery protocol for zero-shot external tuberculosis testing. On COVID-19, the proposed model achieved a weighted F1 of $0.9615 \pm 0.0015$ and macro ROC-AUC of $0.9906 \pm 0.0007$. In an architecture-matched dual-bridge comparison, replacing conventional GAP with MGAP increased ALR from $0.3878 \pm 0.0098$ to $0.7086 \pm 0.0104$ and cALR@0.9 from $0.5265 \pm 0.0101$ to $0.9905 \pm 0.0018$, while weighted F1 remained essentially unchanged ($0.9618 \pm 0.0015$ vs. $0.9615 \pm 0.0015$). Under locked external transfer to Montgomery, ROC-AUC remained $0.9080 \pm 0.0043$ and pulmonary ALR remained $0.6466 \pm 0.0081$, whereas weighted F1 decreased to $0.7528 \pm 0.0080$ and ECE increased to $0.1683 \pm 0.0055$. These findings show that diagnostic discrimination, calibration, and pulmonary attribution containment are distinct model properties and support their joint evaluation under internal testing and external domain shift.

0.52

Example-based Robust Abnormality Detection with Minimal Annotations using Exemplar Med-DETR

cs.CV ·2026-08-25 ·Sheethal Bhat, Bogdan Georgescu, Awais Mansoor, Mathias Zinnen, Pranjal Sahu +3 more
similarity 0.61
Abstract

Reducing annotation requirements remains a key challenge in developing robust medical object detectors. To address this, Vision-Language (VL) object detection methods leverage grounding text information to enable powerful zero-shot and few-shot object detectors in the natural image domain [1, 2, 3, 4]. However, transferring these methods to the medical domain is challenging due to the absence of comparable quality and quantity of the grounding data. Regardless, significant contextual and non-imaging information exists in medical images that remains underutilized. Few-shot learning (FSL) techniques partially address this limitation but struggle to general ize to unseen medical findings and require extensive retraining when new findings are introduced [5, 6]. To overcome these challenges, we extend our prior EM-DETR framework [7] and introduce a scalable FS detection approach designed for efficient abnormality detection in Chest X-Ray (CXR) images under minimal supervision. The proposed architecture incorporates exemplar-based feature generation and domain-aware contrastive optimization, enabling effective adaptation to novel disease findings without exhaustive retraining. Our method achieves near state-of-the-art (SOTA) detection performance using less than 10% of the annotated data, demonstrating its potential for practical, annotation-efficient clinical deployment across both proprietary and public CXR datasets.

0.19

LiFUSE: Frequency-Spatial Unified Self-Supervised Pretraining for Liver Disease Analysis on Non-contrast CT

cs.CV cs.AIcs.LG ·2026-10-13 ·Hao Zhang, Yi Huang, Wei Liu, Yuan Gao, Zeju Li +4 more
published similarity 0.61
Abstract · Accepted at the 2026 IEEE International Conference on Bioinformatics and Biomedicine (BIBM 2026)

Given the growing global burden of liver tumors and diffuse liver diseases, non-contrast computed tomography (NCCT) is increasingly used for opportunistic screening because of its low cost and favorable safety profile. However, downstream tasks such as tumor detection and fine-grained disease diagnosis remain challenging due to NCCT's inherently low tissue contrast, lack of hemodynamic enhancement, and complex anatomical background. These limitations make subtle, heterogeneous, and multifocal hepatic lesions difficult to identify. Although large-scale self-supervised pretraining can learn robust representations from unlabeled NCCT scans, conventional voxel-wise reconstruction does not fully exploit the complementary information available in NCCT. Under weak NCCT contrast, low-level intensity patterns become less informative for pathology recognition, limiting the capture of lesion-specific discriminative features. In this paper, we propose the Liver Frequency-Spatial Unified Self-Supervised Pretraining (LiFUSE). The frequency branch applies random band-stop masking and spectrum reconstruction to encourage the model to capture subtle differences between lesions and surrounding tissues, while the spatial branch performs hybrid-granularity masked volumetric reconstruction to accommodate lesions of diverse sizes and morphologies. Finally, a cross-domain consistency scheme couples the spatial and frequency branches, yielding more discriminative representations for hepatic structures and lesions. Extensive experiments on three clinically relevant tasks across internal cohorts and a public target-domain transfer setting show that LiFUSE consistently outperforms strong baselines. These results suggest that unified frequency-spatial learning can improve liver disease analysis on NCCT, highlighting its potential for large-scale screening.

0.16

B-MIM: Biased Masked Image Modeling for Generalizable Segmentation of Fine-Grained Anatomical Structures

cs.CV ·2026-08-25 ·Sebastián González, Karen Sanchez, José M. Saavedra, Marcelo Pizarro, Bernard Ghanem
published similarity 0.59
Abstract · Published at MedAGI in MICCAI 2026

Self-supervised pretraining enables transferable representations for medical imaging, yet most CT encoders remain biased toward coarse semantic understanding, limiting their sensitivity to fine-grained anatomical structures such as vessels or small tumors. In this paper, we introduce Biased Masked Image Modeling (B-MIM), a modification of the iBOT objective that stochastically reduces global semantic alignment to prioritize local patch reconstruction. This bias encourages the encoder to capture high-frequency morphological details and structural continuity. We curate a multi-institutional CT abdominal dataset of 9,955 filtered studies from 17 public sources and pretrain a 3D Swin Transformer backbone using B-MIM. Across inter-dataset experiments on liver vessel segmentation, the proposed encoder improves topological fidelity (clDice) and achieves competitive Dice scores in tumor segmentation, compared to fully fine-tuned baselines, despite updating only a fraction of the parameters. Our results suggest that reducing global semantic pressure during pretraining enhances generalization to intricate anatomical structures.

0.25

DINO-Med: A Unified Patch-Based Adaptation Framework for Multi-Modal Medical Image Analysis Applied to Liver Fibrosis Staging

cs.CV ·2026-09-10 ·Boya Wang, Ruizhe Li, Chao Chen, Xin Chen
published similarity 0.59
Abstract · 12 pages, 2 figures. Accepted by AIiH

Adapting natural-image foundation models like DINOv3 to multi-modal medical imaging is challenging due to the significant domain gap between natural color images and multi-channel medical scans. We present a unified, patch-based framework that processes raw multimodal imaging through training-free registration, automated localization, and mask-filtered patch extraction. This architecture culminates in a hierarchical strategy that aggregates patch-level insights into subject-level diagnostics. Using liver fibrosis staging as a case study, we evaluate four patch-level feature representations: handcrafted Radiomics features, learned ResNet features, pre-trained foundation model SAM-Med2D features, and frozen DINOv3 features. To ensure a controlled comparison, all models utilize the same lightweight MLP head and are evaluated across both rigid and deformable registration settings. Our training protocol focuses on mild fibrosis (S1) and cirrhosis (S4) classes only, enabling a single classifier to address both substantial fibrosis detection and cirrhosis staging. Evaluated via 10 random train (90%)/ test (10%) splits on 360 subjects from the CARE 2025 Liver Track 4 cohort, our DINOv3-based framework significantly outperforms all baselines, achieving the best classification accuracy of 78.4% for S1 and 75.8% for S4.

0.43

NV-Generate-Body: 3D Latent Diffusion Model forControllable Anatomy, Tumor, and Demographic Body Mask Synthesis

cs.CV ·2026-10-16 ·Can Zhao, Pengfei Guo, Dong Yang, Yufan He, Yucheng Tang +6 more
code/data similarity 0.59
Abstract · Code and model weights open-sourced

Curating large labeled CT datasets is expensive and constrained by patient privacy. We present NV-Generate-BodyMask, a 3D latent diffusion model that synthesizes whole-body CT segmentation masks with precise, joint control over organ anatomy, tumor burden, and patient demographics. The model operates in the compressed latent space of a frozen mask autoencoder, generating $256^3$ volumetric label maps conditioned on a 19-dimensional vector via Adaptive Group Normalization and cross-attention. A size-adaptive ROI loss with spatial halo weighting and a paired tumor injection pipeline enable accurate tumor size conditioning despite the scarcity of annotated tumor cases. Trained on 8,571 masks across 26 cohorts spanning 132 labels, the model achieves Spearman $ρ= 0.70$--$0.92$ for organ size, 85--100\% tumor recall for lung, pancreatic, colon, and bone lesions, and strong demographic alignment (BMI $ρ= 0.78$, sex-conditioned perfect prostate control).

0.34

MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation

cs.CV cs.AI ·2026-10-02 ·Jiaying Li, Paolo Remagnino
top venue similarity 0.59
Abstract

Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

0.32

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

cs.CV cs.AI ·2026-09-24 ·Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli +1 more
similarity 0.59
Abstract · 80 pages including supplementary material, 28 figures, and 22 tables. Supplementary material is included

Long-tailed chest X-ray classification requires visual representations that capture both common abnormalities and subtle, infrequent findings. We propose Med-AR-8B and Med-AR-2B, two radiology-native autoregressive vision-language models pretrained with structured reports, abnormality-focused text, and region annotations. We evaluate the transfer of their visual encoders to multi-label classification against contrastive, self-supervised, and supervised pretrained encoders, including Med-CLIP, CheXFound, EVA-Base, ARK, and BioViL-T, using a common ML-Decoder classification head. To assess fine-grained recognition, we also construct LLM-expanded, report-derived label sets for MIMIC-CXR and CheXpert. Across PadChest, MIMIC-CXR, and CheXpert, Med-AR-8B outperforms Med-CLIP in mean AUROC and AUPRC for head, medium, and tail findings. On MIMIC-CXR, it increases tail-label mean AUPRC from 0.1033 to 0.1441. Med-AR-2B achieves the strongest discrimination results on PadChest. Across the broader encoder comparison, a Med-AR variant achieves the highest mean AUROC and AUPRC in every reported prevalence group on each public dataset. Both Med-AR variants also achieve lower excess area under the risk-coverage curve than Med-CLIP on all three public datasets, indicating improved selective-prediction performance under the evaluated protocol. Internal results are metric-dependent, with Med-CLIP retaining advantages in overall and tail AUPRC and in selective prediction. These findings establish Med-AR as a strong pretraining recipe for long-tailed chest X-ray classification on the evaluated public benchmarks and demonstrate the value of assessing discrimination and selective prediction together.

0.28