CS Paper Radar

HerHealthEval: Evaluating Multilingual and Register-Sensitive Understanding of Women's Health Communication

Hassan Saeed Hassan Albattra, Mazen Mohammed Bahgat, Rahatara Ferdousi, Hana Essam Sayed Ahmed Amrya, Mariam Mousa

cs.CL ·submitted 2026-09-17 16:53 UTC · v1

Abstract

Large language models are increasingly used in healthcare communication, yet most evaluations emphasize response quality while assuming that the user's concern has been interpreted correctly. We introduce HerHealthEval, a controlled evaluation framework for multilingual understanding of women's-health communication. For each clinical case, HerHealthEval provides matched versions in English, French, and Modern Standard Arabic using six communicative forms: canonical, clinical, layperson, indirect or hedged, emotionally concerned, and deliberately under-specified. The first five express the same underlying concern and retain the same clinical information, whereas the under-specified form intentionally omits relevant details to test whether the model recognizes that clarification is needed. We evaluate a multilingual instruction model and QLoRA-adapted variants on concern classification, risk calibration, clarification behavior, parse compliance, and cross-form consistency. Results reveal that aggregate accuracy and consistency can conceal safety-relevant failures. A multilingual adaptation model reaches 0.994 under-triage in French and Arabic under language-asymmetric risk supervision. A controlled re-adaptation using source-derived, language-invariant risk labels reduces under-triage to 0.572 and 0.558, respectively. These findings show that robust multilingual healthcare evaluation requires explicit testing of register variation, uncertainty handling, and the provenance and invariance of adaptation labels.

Comment
8 pages, 2 figures, 3 tables. Submitted to the 2026 International Conference on Large Language Models (LLM 2026)

Closest papers

Nearest neighbours by meaning across the whole index.

"I just assumed that it would translate": examining MT risk awareness among healthcare staff with abbreviations as a use case

cs.AI ·2026-10-01 ·Eleanor Taylor-Stilgoe, Félix do Carmo, Constantin Orăsan
published similarity 0.66
Abstract · To appear in the proceedings of Convergence 2026 conference

In the UK, public healthcare staff report turning to machine translation (MT) - predominantly Google Translate (GT) - to communicate with patients across language barriers. Though intended to support their duty of care, potentially uninformed reliance on MT in such contexts could have serious consequences for patient safety. Research nonetheless remains limited on staff awareness of the possible risks posed by higher-stakes MT use in general and with patient medical records in particular, most existing literature instead examining its use in interpersonal situations or with patient-oriented documentation. Moreover, medical abbreviations are well-documented as increasing patient risk even monolingually, with outcomes from their misuse and/or misinterpretation ranging from temporary harm to the death of the patient. Abbreviations were therefore selected as a use case for identifying the potential risks posed by their translation with MT. Contextualised French and Spanish data examples drawn from authoritative clinical corpora and translated via GT were presented during semi-structured interviews to 21 healthcare staff participants in diverse roles and specialties. The results were then subject to qualitative analysis and cross-analysis.

0.27

HealMed: Multilingual Evaluation of Large Language Models in Medicine

cs.CL ·2026-08-20 ·Yingjian Chen, Fan Gao, Sherry T. Tong, Haoyu Zhang, Aosong Feng +40 more
benchmarkcode/data similarity 0.64
Abstract

We present HealMed, an expert-reviewed benchmark for multilingual evaluation of large language models in medicine. HealMed contains 1,000 examples in each of nine languages, drawn from nine datasets and covering three task formats: MCQA, NLI and open-ended QA. The benchmark was developed over two years by 23 physicians and medical experts based across nine countries and regions. Each translation was evaluated and revised by two experts fluent in English and the corresponding target language. On HealMed, performance declined most in low-resource languages, although the size of the gap varied markedly across languages and models. The strongest proprietary models were the most stable across languages, whereas many open-source and medically specialized models showed larger and less consistent gaps. Medical specialization alone did not ensure multilingual robustness. Furthermore, expert revision could either raise or lower measured performance, indicating that translation quality materially affects cross-language evaluation results.

0.28

Medical Fine-Tuning Reshapes, Not Reduces, Patient-Facing AI Risk: A Rubric-Based, LLM-Judge Evaluation Framework

cs.AI cs.CL ·2026-10-17 ·Savan Doshi
benchmark similarity 0.63
Abstract

Patient-facing medical question answering with large language models (LLMs) is moving from research demonstrations to production deployments, yet evaluation remains anchored on factual correctness. Factuality is necessary but not sufficient: a response can be factually grounded and still issue a directive that, if acted on, would harm the patient. We introduce a risk-sensitive evaluation framework that scores responses by the presence and severity of six categories of risk-bearing language (treatment directives, contraindications, dosage expressions, urgency-triage cues, high-alert medication mentions, and overconfident assertions), anchored on published clinical harm taxonomies. Severity is classified by a three-judge LLM ensemble. We apply this framework to six 7-9B instruction-tuned models, three general (Mistral-7B, Phi-3.5-mini, Llama-3.1-8B) and three medically adapted (BioMistral-7B, OpenBioLLM-Llama3-8B, Med42-Llama3-8B), on 200 real patient questions from the K-QA benchmark. Two findings emerge. First, ensemble risk-bearing language is statistically independent of factual hallucination rate (pooled Spearman $ρ= -0.065$, $n = 300$, 95% CI $[-0.18, +0.05]$; distance correlation $= 0.10$, independence test $p = 0.24$). Second, medical fine-tuning does not reduce aggregate risk but reshapes it: continued-pretraining adaptations (BioMistral, OpenBioLLM) consistently suppress high-alert medication mentions while amplifying overconfident assertions, whereas clinical instruction-tuning (Med42) suppresses dosing only, without amplifying overconfidence. Per-category Krippendorff $α$ is fair to good for the four linguistically anchored categories (0.53-0.71) and low for the two clinical-judgment-dependent categories (0.19, 0.31), indicating where automatic safety evaluation is and is not yet reliable. We release the rubric, judge prompts, and evaluation code.

0.16

Understanding Multilingual Medical ASR Adaptation Through Layer-Wise Analysis

cs.CL cs.AIcs.LGcs.SD ·2026-08-19 ·Souranil Kahali, Rituparna Bose, Abner Hernandez, Tomas Arias-Vergara, Andreas Maier +2 more
similarity 0.62
Abstract

Medical automatic speech recognition (MedASR) requires adaptation to specialised terminology, limited annotated clinical data, and multilingual use cases. Although large-scale pretrained ASR models such as Whisper achieve strong generalisation, their behaviour after medical and multilingual adaptation remains insufficiently understood beyond word error rate (WER). This paper investigates how multilingual medical adaptation reshapes the internal representations of Whisper models through layer-wise encoder analysis. We compare zero-shot decoding, English-only fine-tuning, German-only diagnostic fine-tuning, two-stage EN->EN+DE continuation, and direct EN+DE fine-tuning across Whisper model sizes. Fine-tuning substantially improves MedASR performance, but the best model depends on the adaptation setting: Whisper-Medium gives the lowest English WER (7.72%) and the lowest combined EN+DE WER under direct EN+DE training (26.30%); German-only Whisper-Large-v3 gives the lowest German WER (44.96%), but as a within-corpus diagnostic on 86 single-speaker training utterances rather than robust generalisation. Layer-wise analysis of the two-stage Whisper-Small trajectory shows that English medical fine-tuning produces the dominant encoder shift, whereas multilingual continuation largely preserves the adapted representation space. Domain and language information remain highly recoverable across layers, while linearly recoverable error-predictive cues weaken as WER improves.

0.10

CardioLM: A multilingual suite of small language models for the cardiology domain

cs.CL cs.AI ·2026-11-05 ·Manuela-Daniela Danu, Miguel Rodríguez-Ortega, Alberto Becerra-Tome, Pablo Arancibia, Fernando Gallego-Donoso +35 more
benchmark similarity 0.62
Abstract · 91 pages, 7 figures, 33 tables (9 in the main text, 23 in Appendix A, and 1 in Appendix B)

Background: Cardiovascular care generates large volumes of clinical free-text documentation in local languages. However, clinical natural language processing (NLP) resources remain concentrated in English, and no existing benchmark is cardiology-specific, multilingual, and broad in entity coverage. Methods: We present two contributions. The first is CardioCCC, a corpus of 508 cardiology case reports originally published in Spanish and extended to Czech, Dutch, English, Italian, Romanian, and Swedish through machine translation, annotation projection, and clinician review, with annotations covering diseases, symptoms, procedures, and medications. The second is CardioLM, comprising CardioBERTa, a set of language-specific encoders obtained by continued pretraining on cardiology and biomedical corpora, and CardioNER, a set of named entity recognition (NER) models fine-tuned on CardioCCC. Results: Cardiology-specific pretraining reduced pseudo-perplexity by up to a factor of eight, yet changed strict span-level F1 by at most 0.04, with benefits concentrated in languages whose backbones lacked biomedical coverage. The jointly trained multilingual XLM-RoBERTa-large models achieved the best strict F1 in nearly every language and entity type, exceeding the strongest monolingual system by up to 0.13 F1. A large share of residual errors concerned boundary detection: relaxed matching recovered 0.10-0.23 F1 for disease, procedure, and symptom, but only 0.01-0.07 for medication. Clinicians rated CardioNER well above a rule- and dictionary-based baseline, with the mean rating across entity types rising from 26% to 73%. Conclusions: Specialty-specific pretraining is not the decisive factor for downstream entity recognition, whereas multilingual joint training yields the strongest results in nearly all settings and a simpler deployment path for multi-country clinical information extraction.

0.24

How I Aligned Your Model: Scaling Up Multilingual Safety Training with Templates

cs.CL cs.AIcs.LG ·2026-10-29 ·Max Neuwinger, Hanna Yukhymenko, Imanol Schlag
similarity 0.62
Abstract

Safety alignment for Large Language Models is heavily focused on English with limited multilingual representation, particularly damaging low-resource language performance. Related open training datasets are often limited in size or do not follow region-localized harmful topics to broaden the scope of alignment beyond cultures. We propose a scalable template-based augmentation pipeline to produce massive multilingual refusal and benign corpora, extracting safe templates from harmful prompts, translating them and then filling in the slots with culturally authentic entities, both harmful and benign. As a result, we release MSafeTemp, a validated corpus spanning 60 languages useful for multilingual safety alignment and evaluation. Using the dataset, we show that English-only evaluation misjudges multilingual safety: for several models, attacks that fail in English succeed once translated, while culturally localized variants expose further failures that translation alone misses. We also confirm that augmenting safety training data through templates allows for higher diversity and quality of alignment, resulting in improved safety performance beyond English. MSafeTemp and the respective pipeline are aimed at facilitating research and development of safer and more responsible models for less-represented cultures.

0.15

Multilingual Safety Signals Are Multi-Layered: Filtering Safety-Degrading Data for Safer LLMs

cs.CL cs.AIcs.LG ·2026-08-26 ·Jiakun Li, Guowei Song, Sijia Li, Xingwei He, Hongzheng Chai +1 more
top venue similarity 0.61
Abstract · Accepted to EMNLP 2026 Main Conference. 16 pages, 11 figures

Preserving safety alignment during large language models fine-tuning is critical, however, recent studies have demonstrated that even benign fine-tuning data may contain safety-degrading samples that silently undermine safety alignment. Existing approaches typically identify such samples using representations from a single safety-sensitive layer. While this assumption has shown effectiveness in monolingual settings, its validity for multilingual models remains unclear due to potential cross-lingual differences in representation patterns. Through a cross-lingual analysis, we show that sensitive layers are only partially shared across languages, with safety-relevant signals often distributed across multiple layers. Motivated by these observations, we propose MMSAFE, a multi-layer framework for multilingual safety-degrading data identification that captures both shared and language-specific safety signals. Extensive experiments across multiple models, languages, and safety benchmarks demonstrate that MMSAFE reduces the average harmful-response ratio by 60% compared with random filtering and achieves stronger average performance than the strongest single-layer baseline, demonstrating the effectiveness of multi-layer modeling for robust multilingual safety alignment.

0.39

Complex-Text Robustness Evaluation and Failure Diagnosis for Low-Resource Multilingual Text-to-Speech

cs.CL cs.SD ·2026-09-10 ·Tianlun Zuo, Ziyu Zhang, Tingzhi Mao, Zhonghua Fu, Lei Xie
published similarity 0.61
Abstract · NCMMSC 2026 accepted

Low-resource multilingual text-to-speech (TTS) systems have expanded language coverage, but their robustness under complex text inputs remains insufficiently diagnosed. Existing evaluations mainly focus on naturalness, speaker similarity, and content consistency using regular test sentences, while providing limited insight into how multilingual TTS systems fail when handling challenging inputs such as numbers, dates, named entities, long sentences, code-switched expressions, and punctuation-related structures. This paper proposes a complex-text robustness diagnosis framework for low-resource multilingual TTS. We evaluate robustness from three dimensions: content consistency, language consistency, and generation stability. A multilingual robustness testing scheme is designed for Thai, Vietnamese, Swahili, and Indonesian, covering ordinary sentences and multiple types of complex text inputs. We further introduce automatic diagnostic metrics, including character error rate, language identification accuracy, and duration abnormal rate. To support input-level risk analysis before speech generation, we propose a lightweight Text Risk Score (TRS), which estimates synthesis risk from interpretable text features without manual annotation or model training. Experiments on three representative multilingual TTS systems, including OmniVoice, VoxCPM2, and MMS-TTS, show that complex text inputs expose systematic failure patterns that are not fully reflected by ordinary short-sentence evaluation. Different systems exhibit distinct vulnerabilities in number normalization, named entity handling, long-text generation, and code-switched input processing. Furthermore, TRS shows a positive correlation with content errors and duration abnormalities, demonstrating its usefulness as a low-cost pre-synthesis indicator for complex-text risk diagnosis in low-resource multilingual TTS.

0.38