Qinghui Liu, Jon André Ottesen, Thu Nguyen, Geir Ringstad, Ingrid Mossige, Siri Fløgstad Svensson, Sissel Riis Kalstad, Atle Bjørnerud, Per Kristian Eide, Kyrre Eeg Emblem

eess.IV cs.AIcs.CVcs.LG ·submitted 2026-09-17 20:49 UTC · v3

Abstract

The brain fluid clearance system can be studied with intrathecal contrast-enhanced magnetic resonance imaging (MRI). By injecting a tracer into the spinal canal and performing MRI over 24--48\,h, one can measure how a tracer injected into the cerebrospinal fluid spreads through the brain. As this is an invasive procedure requiring several MRI scans, we ask how much of the later tracer distribution can be predicted from the pre-contrast scan and elapsed time alone. Using 104 training patients (878 MRI volumes), we compared a direct image-to-image regression model with a more complex generative model based on conditional flow matching, and tested both on 23 held-out patients and on 51 patients from a separate cohort with idiopathic normal pressure hydrocephalus (iNPH). Relative to simply copying the pre-contrast scan, the direct model reduced the mean absolute error (intensities normalized to $[0,1]$) from 0.089 to 0.036, about 60\%, in held-out patients and from 0.075 to 0.056, about 25\%, in the iNPH cohort. The reduction held in every sampled elapsed-time interval and brain compartment, and errors remained largest at 20--30\,h and in the ventricles, where enhancement is strongest. Its predicted change maps agreed with the observed tracer enhancement rather than only reproducing anatomy. The generative model was less accurate in both cohorts. A substantial part of the later tracer distribution is therefore predictable from the patient's brain anatomy as seen on pre-contrast MRI, and the added model complexity gave no benefit at this data scale. Whether this accuracy suffices for a given clinical use remains to be established; with prospective validation, such forecasts could help simplify the MRI protocol used to assess brain clearance.

Comment
34 pages, 13 figures, 6 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Generalizable field of view extension for diffusion MRI via conditional flow matching

cs.AI ·2026-10-12 ·Gaurav Rudravaram, Lianrui Zuo, Ema Topolnjak, Michael E. Kim, Adam M. Saunders +20 more
similarity 0.65
Abstract

Incomplete field-of-view (FOV) diffusion MRI (dMRI) acquisitions compromise whole-brain white matter analysis by excluding brain regions from tractography and connectivity studies. While deep generative models for dMRI FOV extension have been proposed, their generalizability remains limited by the acquisition-dependent nature of dMRI, where signal intensity varies with b-value, gradient direction, and scanner protocol, and the inherent 4D complexity of the data, making it difficult to train models that transfer across sites or acquisition schemes without retraining. We propose a flow-matching generative model that extends the dMRI FOV in both the superior and inferior directions by predicting apparent diffusion coefficients (ADC) in six directions, conditioned on the two nearest acquired slices and the full-FOV T1w image to enforce both local diffusion continuity and anatomical consistency. The ADC representation decouples the model from acquisition-specific b-values and gradient directions, providing a middle-ground across protocols. The model was trained on 3,103 subjects (5,105 sessions) across five different datasets spanning diverse acquisition schemes (b = 500 and 1000 s/mm$^2$; 21--192 gradient directions), four single-shell (b = 1000) and one multi-shell (b = 500/1000). Evaluated on 299 subjects across five independent datasets spanning b = 750--1500 s/mm$^2$ and 32--90 gradient directions, with single- and multi-shell schemes unseen during training, the proposed method achieves significantly improved bundle Dice score on downstream tractography (p < 0.01).

0.16

GliomaINK: A Tumor and Anatomy Conditioned Flow Matching Framework for 3D MRI Sequence Synthesis in Glioma Patients

eess.IV cs.CVq-bio.TO ·2026-10-16 ·Moinak Bhattacharya, Annie Singh, Mohammad Chaudhry, Prateek Prasanna, Gagandeep Singh
similarity 0.65
Abstract

Background: Incomplete multiparametric MR examinations limit glioma characterization and downstream AI tools. Generative models can synthesize missing MRI sequences, but anatomical structure and clinically relevant tumor features are challenging to preserve. We propose GliomaINK, an anatomy-guided conditional flow matching framework for cross-sequence 3D brain MRI synthesis. Methods: A 3D SwinUNETR predicted the conditional velocity field while an auxiliary topology-preserving loss encouraged structural consistency. The model was trained on 1,083 patients from the BraTS-AG dataset and independently tested on an in-house clinical cohort. Downstream tasks include image quality, tumor segmentation, IDH1 mutation-status prediction, and overall survival prediction. Two radiologists independently evaluated the anatomical fidelity, pathological representation, and overall image quality of the synthesized images. Results: GliomaINK exhibited the highest PSNR across all six MRI translation directions in both evaluation cohorts. In the BraTS-AG test set, the PSNR reached $25.64\pm0.55$ dB for the T2W-to-T1C synthesis, compared with $13.78\pm0.32$ dB for Pix2Pix and $18.90\pm0.53$ dB for SPADE. For downstream tumor segmentation, the method showed strong performance across tumor subregions with Dice scores reaching $0.928\pm0.014$ for edema, and $0.885\pm0.040$ for enhancing tumor. For the IDH1 mutation-status prediction, GliomaINK achieved the highest AUROC score in four of the six sequence configurations, reaching $0.827\pm0.088$. Conclusion: Anatomy-guided conditional flow matching enables high-fidelity cross-sequence glioma MRI synthesis demonstrating potential for preservation of clinically relevant information in synthesized MRI and improving downstream tasks.

0.18

Conditional Flow Matching for Cross-Field MRI Harmonisation

cs.CV ·2026-09-01 ·Baris Imre, Aram Salehi, Levente Baljer, Andrew Webb, Marius Staring +1 more
similarity 0.64
Abstract · 10 pages, 2 figures

Magnetic resonance images of the same subject look markedly different across field strengths, which complicates the comparison and pooling of data across sites. We address cross-field brain-MRI translation for the MRIxFields2026 challenge, and in particular its Task~3: a single model that translates between any directed pair of the five field strengths and across three contrasts. We phrase the problem as a conditional flow matching path: because the source and target volumes are spatially registered, we learn a velocity field that carries the source slice directly to the target slice, rather than starting from noise. To learn this mapping from only three paired subjects, the unified model is trained in three stages: a degradation-bridge pretraining that distills a restoration prior from the abundant unpaired retrospective cohort, a cross-field finetuning over all directed pairs on the paired cohort, and an adversarial refinement that sharpens the output. At inference, we integrate the learned velocity with a second-order Heun solver in a handful of steps. A restoration prior learned without any paired data already reaches a mean SSIM of 0.837, and each subsequent training stage improves on it. A single 6.3M-parameter model thereby covers all 60 field-pair and contrast combinations, with inference in five solver steps per slice. On the challenge evaluation set the model reaches a mean SSIM of 0.909, averaged over the three contrasts, outperforming regression and diffusion baselines built on the identical network on all three challenge metrics.

0.22

C-WFDM: A ControlNet-Guided Wavelet-Fusion Diffusion Model for Multimodal Brain MRI Completion

cs.CV ·2026-11-03 ·Muhammad Nabi Yasinzai, Remika Mito, Mangor Pedersen
similarity 0.63
Abstract

Multimodal brain MRI provides complementary anatomical, tissue, and pathological information to support downstream artificial intelligence (AI) applications. However, modality availability is uneven across public and pooled neuroimaging datasets: T1-weighted (T1w) MRI is widely represented, T2-weighted (T2w) and fluid-attenuated inversion recovery (FLAIR) MRI are less consistently available, and gadolinium-enhanced T1-weighted (T1Gd) MRI is relatively scarce. Pooled datasets therefore contain participants with different combinations of acquired MRI contrasts, reflecting variation in the study designs, acquisition protocols, and clinical or research objectives of the contributing studies. Many missing-modality benchmarks simulate incomplete MRI by withholding contrasts from complete four-modality cases, which may not represent the observed availability patterns in pooled datasets. To address this gap, we introduce C-WFDM, a ControlNet extension of our Wavelet-Fusion Diffusion Model (WFDM), for subject-specific missing-modality completion. C-WFDM is built on an earlier BrainScape snapshot comprising 157 public MRI datasets and 45,880 preprocessed scans. The pretrained WFDM backbone retains target-modality and metadata conditioning, while target-specific ControlNet adapters use MRI contrasts from the same participant to guide synthesis. C-WFDM synthesizes T2w from T1w, FLAIR from T1w and T2w, and T1Gd from T1w, T2w, and FLAIR. Acquired conditioning contrasts are used when available, and generated intermediate contrasts are used only when required. We compare C-WFDM with ALDM, cWDM, and Pix2Pix using paired structural similarity index (SSIM), peak signal-to-noise ratio (PSNR), and mean absolute error (MAE). In the BrainScape completion experiment, C-WFDM achieves the best T2w and FLAIR results among the evaluated models, with SSIM values of 0.9232 and 0.8904, respectively.

0.26

Covariate-Conditioned One-Step Diffusion for Multi-Horizon 3D Brain MRI Prediction in Aging and Neurodegeneration

eess.IV cs.AIcs.CVcs.LG ·2026-11-05 ·Natenaile Asmamaw Shiferaw, Ali Farki, Deepika Koundal, Jussi Tohka
code/data similarity 0.62
Abstract · 5 pages, 2 figures, 4 tables. Submitted to IEEE ISBI 2027

Predicting longitudinal brain changes from magnetic resonance imaging (MRI) can help characterize structural progression associated with aging and neurodegeneration. However, diffusion-based forecasting typically requires iterative denoising, limiting inference efficiency. We propose a covariate-conditioned one-step diffusion framework for multi-horizon prediction of 3D gray-matter density (GMD) maps. Rather than directly generating future anatomy, the model predicts longitudinal GMD changes through residual prediction in a single denoising step. The predicted changes are added to the baseline GMD map to reconstruct future anatomy. The model is conditioned on baseline anatomy, age, diagnosis, APOE4 allele count, and continuous follow-up time. Training combines mean squared error with a Pearson correlation loss to improve the spatial agreement between predicted and observed GMD changes. A unified model supports prediction horizons from 2 to 10 years. On the held-out ADNI test set, our method achieves a $Δ$-Pearson of 0.478, mean squared error (MSE) of $5.176 \times 10^{-3}$, and structural similarity index measure (SSIM) of 0.979, with $Δ$-Pearson reaching 0.582 at 10 years. Without retraining, external evaluation on AIBL yields a $Δ$-Pearson of 0.450, MSE of $4.016 \times 10^{-3}$, and SSIM of 0.985. Ablation studies further demonstrate the benefits of residual prediction, covariate conditioning, and correlation-based supervision. Code: https://github.com/natenaile/OneStepBrainMRI.

0.34

VariaFlow: Uncertainty-Aware Flow Matching for Unsupervised Anomaly Detection

cs.CV ·2026-10-30 ·Arnela Hadzic, Martin Urschler, Cosmin I. Bercea
published similarity 0.61
Abstract · Accepted for WACV 2027

Reconstruction-based anomaly detection no longer fails at reconstruction. Generative models produce high-quality pseudo-healthy reconstructions, and the remaining difficulty is the step of scoring residuals. The residual between a scan and its reconstruction has two indistinguishable sources, genuine pathology and the anatomical variation that separates one healthy brain from another. Scoring against a single reconstruction treats both as anomalous, inflating false positives where healthy anatomy varies most while small or subtle lesions are lost in the surrounding reconstruction error. We identify the missing quantity as the predictive variance, how much a healthy reconstruction can vary at each location. We introduce VariaFlow, which estimates this variance from an ensemble of mask-guided restorations under an unconditional flow matching prior, each started from a different noise initialization, and which normalizes the residual by the resulting standard deviation. Few-step flow matching keeps the ensemble computationally affordable, and restoring at two spatial scales captures lesions of different size. Across three brain MRI datasets spanning stroke and tumor, VariaFlow is trained once on healthy anatomy and generalizes across all three, attaining the highest AUROC (0.94, 0.80, 0.78) on each and the highest AUPRC on both cross-domain datasets, exceeding the strongest baseline by 37% and 50%. Under domain shift, the same baseline drops by up to 52% in AUPRC, whereas VariaFlow stays more stable and achieves the best small-lesion Dice on all three datasets.

0.29

Pathology Randomization for Synthetic Priors and Zero-Shot Detection

cs.CV cs.AIeess.IV ·2026-11-16 ·Alexandra G. Roberts, Tonmoy Hossain, Mark Olchanyi, Stefan Brandstätter, Jonathan Williams Ramirez +5 more
benchmarkcode/data similarity 0.61
Abstract · 25 pages, 9 figures, 13 tables (8-page main text with appendices). Code: https://github.com/agr78/Pathology-Randomizer

Hospital brain imaging archives hold a diverse array of pathology at sample sizes beyond prospective studies, particularly for underrepresented populations and diseases. To unlock uncurated clinical data and scale analysis, methods are needed to detect abnormalities across contrasts and resolutions. Synthetic data has provided robust, contrast-agnostic models for a variety of human neuroimaging tasks in healthy anatomy, but pathology detection and other tasks in clinical settings still require real patient data, contrast-specific models, or disease-specific generators. We propose PathoDraw, a generative model of brain MRI with pathology. A conditional distribution of lesions given the healthy anatomy is drawn into the label map before contrast-agnostic rendering, and a single network estimates healthy anatomy with exact signed intensity deviation of any input scan. The contrast-agnostic 3D UNet learns the healthy labels under the lesion and the signed deviation directly and identifies pathology via robust tissue statistics and learned features, despite no training on real pathology. We show zero-shot detection on public stroke, tumor, and white matter hyperintensity datasets as well as archived clinical data, spanning $T_1$w, FLAIR and $T_2$w at various resolutions under a recent unsupervised anomaly detection benchmark protocol. Our single model exceeds or performs comparably to contrast-specific anomaly detectors trained on real scans and keeps healthy anatomy intact. The same generator trains networks for super-resolution and for registration in the presence of pathology. Our model, robust across acquisition and disease, enables the use of uncurated, archived data for clinical analysis. Our code is available at https://github.com/agr78/Pathology-Randomizer.

0.47

Spatial Feature-wise Linear Modulation (SpFiLM) for Contrast Agent-Aware Brain Parcellation

eess.IV cs.CVcs.LG ·2026-09-07 ·Pushpendra Singh, Joshua R. Astley, Roman Rodionov, John Duncan, Tom Vercauteren +1 more
published similarity 0.60
Abstract · 10 pages, 2 figures. Accepted at MLCN 2026 (MICCAI workshop)

Most automated brain parcellation tools are developed and validated on T1-weighted (T1w) MRI. Yet, some clinical workflows for which parcellation is relevant only use contrast-enhanced T1w (T1ce) MRI, on which T1w-trained models are less accurate. We present a unified network that parcellates both pre- and post-contrast agent T1w MRI reliably, trained on a combination of the two with conditioning that spatially modulates its response differently for each. Feature-wise Linear Modulation (FiLM) is a known approach for input-based modulation in networks. It applies a per-channel scale and shift uniformly across the input. However, the appearance change between pre- and post-contrast varies locally across the brain, making FiLM suboptimal for our use case. In this work, we introduce Spatial FiLM (SpFiLM), a conditioning layer whose modulation varies spatially, assembling a voxel-wise scale and shift from image-derived spatial patterns. Using a cohort of 134 patients with paired T1w and T1ce MRI parcellated into 106 classes, the addition of SpFiLM layers in a UNet increased the mean Dice on the test set of 25 patients from 80.2% to 84.1%, a 4.9% relative improvement. Adding SpFiLM layers led to the best performance on both pre- and post-contrast MRI, even when controlling for network parameter counts.

0.34