CS Paper Radar

Gaze responses to false-positive computer-aided detection prompts during colonoscopy: a paired-video and real-time eye-tracking study

Te Luo, Yan Zhu, Peiyao Fu, Ruijie Yang, Xian Yang, Quanlin Li, Pinghong Zhou, Shuo Wang

cs.AI ·submitted 2026-09-22 02:24 UTC · v1

Abstract

False-positive computer-aided detection (CADe) prompts may divert endoscopists' attention during colonoscopy, yet the attentional impact of individual prompts remains unclear. We used event-locked eye tracking to quantify gaze attraction and attention occupation in complementary retrospective and prospective studies. In a retrospective paired-video experiment, 3 senior and 2 novice endoscopists viewed 60 colonoscopy videos with and without CADe. The prospective study recorded gaze during 42 real-time CADe-assisted colonoscopies performed by 9 senior endoscopists. Screened CADe prompts outside expert-annotated lesion windows were classified as false-positive artifact events. False-positive prompts attracted gaze in 48.6% (68/140) of retrospective observations and 65.2% (533/817) of prospective events. Among attraction events with complete recovery, median attention occupation lasted 1000 ms in the retrospective study and 1100 ms in the prospective study. Corresponding median prompt durations were 33 ms and 267 ms, with median time amplifications of 17.55-fold and 5.15-fold, respectively. In paired retrospective comparisons, visible artifact prompts drew gaze closer to the prompted region than did the same-coordinate unassisted reference. Secondary retrospective analyses showed high lesion gaze recognition without and with CADe (98.0% versus 99.0%). First gaze entry into lesion regions occurred 147.8 ms earlier with CADe. Across controlled and real-time clinical settings, false-positive CADe prompts frequently captured gaze, with attention persisting beyond prompt visibility. These findings support considering prompt-related attentional burden in CADe evaluation and design.

Comment
21 pages,3 figures

Closest papers

Nearest neighbours by meaning across the whole index.

SurgGaze: Implicit Calibration for Accurate Gaze Analysis in Operating Rooms with Wearable Eyetrackers

cs.HC ·2026-09-22 ·Jingying Wang, Rosiana Natalie, Keyuan Hu, Wenqian Xu, Brian George +3 more
similarity 0.64
Abstract

Accurate gaze tracking is essential for understanding surgeons' visual attention and cognitive processes during laparoscopic surgery, yet wearable eye trackers produce large errors systematically correlated with ground-truth gaze locations, as demonstrated in Study 1. We introduce SurgGaze, an implicit calibration method that corrects these errors using high-confidence surgical moments. Building on evidence that surgeons' gaze converges near the tool-tissue contact point (TTCP) during dissection, SurgGaze uses TTCP as a surrogate for true gaze to construct training pairs. We evaluate SurgGaze in a simulated operating room trial and an authentic operating room case study. In simulation, SurgGaze reduced gaze estimation error by 40.6%, significantly outperforming conventional 9-point explicit calibration. The case study showed that these moments provide reliable training data and that calibrated gaze improves interpretation of surgeons' attention beyond numeric error reduction. These findings demonstrate that structured behavioral signals can enable implicit calibration for gaze tracking in complex real-world settings.

0.28

GazeRIB: Systematic Evaluation of Multi-Reader Gaze-Guided Chest X-ray Learning

cs.CV cs.HCeess.IVeess.SP ·2026-10-30 ·Nattakorn Kittisut, Roy M. Gabriel, Marly van Assen, Mohammadreza Zandehshahvar, Carlo N. De Cecco +2 more
similarity 0.57
Abstract · 20 pages on main manuscripts (3 tables + 4 figures), 14 pages supplementary (10 tables + 8 figures)

Radiologists' visual attention can supervise medical image learning, but how reader panel composition affects its value remains untested. We evaluated GazeRIB (Gaze-guided Radiologist-Informed Blackout), which masks unviewed regions during training and uses unmasked images at inference. Eight experts repeatedly read the same 80 chest X-rays (CXRs). We compared individual readers with three-, five- and eight-reader panels across seven architectures and 10 seeds, evaluating 910 models on a separate 2,897-CXR cohort for four-class severity prediction. Every panel improved macro F1 over the no-gaze baseline by 5.33-7.47 percentage points (pp; Bonferroni-adjusted p < 0.007); no individual reader reached significance on this endpoint. Three readers captured 73-80% of the eight-reader gain in macro F1, the area under the receiver-operating-characteristic curve (ROC-AUC) and the area under the precision-recall curve (AU-PRC). On external validation without retraining, all four panels improved ROC-AUC on SIIM-FISABIO-RSNA by +1.93 to +4.24 pp (p <= 0.004); on MIMIC-Eye no panel differed significantly from baseline, whereas the single-reader average declined (-1.40 pp, p = 0.008). Reader composition therefore influenced performance, although transfer depended on the cohort.

0.17

GazeFS: Target-Centered Gaze-Trajectory Forecasting and Stabilization from Gaze-Head History

cs.HC cs.AI ·2026-09-03 ·Yaozheng Xia, Zaiping Zhu, Bo Pang, Minghao Xie, Hui Li +2 more
similarity 0.56
Abstract

Target-centered gaze interaction requires more than suppressing frame-to-frame fluctuations: target acquisition produces task-aligned changes in gaze-head dynamics, while a gaze trace may retain a persistent target-relative residual direction. We formulate gaze correction as online target-centered gaze-trajectory forecasting and stabilization and introduce GazeFS, which maps a variable-length gaze-head history to the next target-center direction and a short-horizon Search/Focus estimate without target information at inference. Across 7,960 acquisition episodes from 30 participants, Search-Focus differences remain stable under quality control, onset exclusion, and duration matching. History windows improve phase decoding over the current endpoint, but explicit task progress remains a strong control. Under the 30-participant, five-fold grouped out-of-fold protocol across three seeds, the reductions relative to raw hold in Focus episode bias, within-episode dispersion, and P90 target error are 0.182 degrees, 0.257 degrees, and 0.400 degrees, with participant-bootstrap 95% confidence intervals excluding zero. Endpoint-free replay from empty history preserves the Focus advantage and yields raw-network phase balanced accuracy/AUPRC of 0.925/0.993; coordinate controls further show that recent history contributes beyond explicit progress metadata. GazeFS therefore improves Focus target centering and empirical residual contraction while leaving temporal smoothness as a separate objective.

0.21

Low Cost Eye Tracking for Vision Screening

cs.RO ·2026-09-25 ·Maissa Abir Smaili, Yaman Ismaiel, Zafer Iscan
similarity 0.56
Abstract · 5 pages, 7 figures

This engineering study assesses gaze-assisted data acquisition during visual screening with a Gaze Quest implementation via webcam and GC308 near infrared camera with an Orlosky eye tracking pipeline. Ten subjects performed under both acquisition conditions. Accuracy of Tumbling E orientation, reported application logMAR value,and response latency were determined from keyboard responses and hence are behavioral outputs as opposed toeye tracker screening results. Frame-to-frame change in theangle between successive normalized gaze vectors (28.2degrees) served as the GC308 eye tracker derived diagnostic with an effective sampling rate of roughly 8 FPS. No screen target calibration or gaze to screen translation was done on the GC308 eye tracker output data for the current analysis and hence, these data represent acquisition stability and not gaze accuracy in relation to the target. The webcam pipeline relied on 25-point screen calibration. Because the display resolution and pixel pitch could not be retained in the records of the study, the reported application logMAR values cannot be viewed as measures of visual acuity in any way.

0.20

EndoSCOP-V: A Multi-Turn Video Understanding Evaluation Framework for Multimodal Models in Endoscopy Reporting and Clinical Reasoning

cs.CV cs.AI ·2026-11-07 ·Abhishek Tyagi, Tanmay Jain, Vilas Biradar, Krithi Krishna Koduri, Misba Hul Bashir Masoodi +13 more
published similarity 0.56
Abstract · NeurIPS 2026

Endoscopic diagnosis unfolds over native video, where a single positive finding during traversal of the gastrointestinal tract sets off a multi-minute chain of reasoning over location, morphology, severity and intervention. Existing endoscopy multimodal benchmarks test only static images or single-disease videos, which miss the temporal and clinical reasoning that real-world reporting demands. We introduce EndoSCOP-V, a video-grounded multi-turn evaluation framework for structured endoscopy reporting and clinical reasoning. It contains 1,307 real-world endoscopy and colonoscopy videos (63.2 h; 97% 1080p) averaging about 174 s. Its 20,274 question-answer turns are instantiated deterministically from clinician-filled structured endoscopy-reporting EHRs, so no per-case annotation is synthetic or LLM-rephrased. They come from 1,033 clinician-reviewed templates, about 18 per disease, that span a clinically aligned 9-task x 30-sub-task reporting taxonomy over 54 World Endoscopy Organization (WEO) MST 3.0 diseases. 22% of procedures carry co-existing pathologies, up to six per case. A Markovian context-pruned oracle-forcing protocol evaluates the dialogue turn by turn, injecting the gold answer before each subsequent turn so that per-turn reasoning is isolated from cascading dialogue errors. A panel of 15 board-certified endoscopists sets a 78% strict-accuracy baseline on 1,500 questions. Across 14 open-weight LMMs, the best 27B-class model reaches 59.8% strict accuracy, falling to 53.4% once format-trivial disease-rejection items are excluded. On a between-subjects spot-check, the best of 3 frontier proprietary models trails the clinician panel by 23 pp on strict NDR accuracy. Sub-task analysis reveals consistent gaps in quantitative measurement, multi-variable grading and intervention reasoning on long-horizon video. Data: Hugging Face (EndoSCOP-V). Code: GitHub (abhi25t/EndoSCOP-V).

0.26

An Eye-Tracking Dataset for Viewing Distance Categories in Real-World Scenarios

cs.HC ·2026-08-29 ·Dohwa Kim, Yejin Choi, Seungbok Lee, Chi Yoon Jeong, Eunji Park
dataset similarity 0.55
Abstract · 22 pages, 6 figures, Manuscript submitted to Scientific Data

Estimating viewing distance from gaze behavior is essential for understanding user intent and enabling distance-aware interactive systems. However, most existing eye-tracking datasets have been collected in constrained settings, such as laboratory environments or static tasks. Consequently, they only partially capture viewing behaviors in real-world situations where viewing distance changes with natural head and body movements. We introduce GazeDepth, an eye-tracking dataset collected from 19 participants using a wearable tracker during tasks reflecting real-world scenarios. GazeDepth includes fixed-distance viewing scenarios with constant observer-target distances at near (33 cm), middle (50 cm), and far (300 cm), as well as variable-distance viewing scenarios in which participants shift gaze among targets at different depths in indoor and outdoor environments. The dataset provides synchronized gaze data, pupil size, 3D eye-vectors, and head-motion signals, along with distance labels. Statistical analyses showed that distance-related gaze features, such as vergence angle and estimated viewing distance, differed consistently across viewing-distance categories. In addition, classification models trained on GazeDepth further demonstrated that the dataset captures gaze characteristics that distinguish the three viewing-distance categories, supporting gaze-based distance inference and distance-aware interaction in realistic scenarios.

0.26

How Early Can You Tell? Early Eye Gaze Dynamics and Cybersickness Progression in Virtual Reality

cs.HC ·2026-09-21 ·Nevzat Umut Demirseren, Isayas Berhe Adhanom
similarity 0.54
Abstract · 6 pages, 3 figures

Cybersickness remains one of the primary barriers to prolonged and comfortable virtual reality (VR) use, yet the temporal development of cybersickness remains poorly understood because its onset and progression vary substantially across individuals. Eye tracking provides a continuous and unobtrusive measure of user behavior, making it well suited for investigating how users respond throughout VR exposure. However, existing work has mainly focused on aggregate gaze measures or post-exposure assessments, leaving the relationship between early eye-movement dynamics and discomfort progression underexplored. In this paper, we investigate whether early eye-movement dynamics characterize the subsequent progression of cybersickness. Using trajectories of fixation duration, fixation dispersion, saccade amplitude, saccade velocity, and gaze eccentricity computed over the first one to five minutes of VR exposure, we evaluate their association with subsequent discomfort progression and compare early gaze dynamics between participants with low and high post-exposure cybersickness severity. Our results show that early fixation dispersion is consistently associated with subsequent discomfort progression, whereas no significant differences are observed between cybersickness severity groups. These findings suggest that early fixation dispersion can characterize the progression of discomfort rather than the final cybersickness severity. Overall, this work provides new insight into the temporal relationship between early eye-movement behavior and cybersickness progression, contributing to the understanding of gaze dynamics during immersive experiences.

0.19

RadAI: Gaze-Intention Fusion Pipeline for Attention-Guided Educational Videos in Chest X-Ray Interpretation

cs.CV ·2026-10-24 ·Kavish Mehta, Yuvan Siddharth Katamaneni, Akash Awasthi
publishedhot direction similarity 0.54
Abstract · 5 pages, 2 figures, 1 table, accepted to 2026 MIT IEEE URTC conference

Chest radiograph interpretation errors often arise from failures in visual search: although trainees may correctly identify an abnormality once pointed out, they frequently fail to fixate on the relevant region, while expert search strategies (where radiologists look, in what sequence, and for how long) remain largely implicit. Eye movement modeling examples (EMME), which replay a recorded expert's gaze over the image, have been shown to improve novice detection of findings on chest radiographs, but producing one requires an eye-tracking session on that specific case, so teaching sets are limited to recorded sessions by experts. In this work, RadAI is presented, the first end-to-end framework for transforming predicted radiologist gaze into narrated instructional videos, enabling scalable gaze-guided training without collecting new eye-tracking data. Given only a chest X-ray and its report, RadAI predicts an expert fixation sequence, associates each interval of that sequence with the diagnostic finding it pursues, extracts the corresponding image region, and renders the result as an EMME-style video in which each highlighted finding is narrated with synthesized speech. RadAI is evaluated on 97 cases from the EGD-CXR dataset, assessing whether the highlighted regions correspond to annotated abnormality locations. We position this work as a framework for scalable generation of educational content for residents and medical students in the field of radiology.

0.34