CS Paper Radar

Contact-Stable Deformable Tissue Simulation Using Implicit Integration and Live-Pose Grasp Constraints for Laparoscopic Surgery Robot Policy Evaluation

Juahn Oh, Dongho Yee, Jinseok Lee, Jiyul Lee, Yechan Seo, Seong Jeong, Minsung Kim, Seonho Shim, Younghoon Noh, Hyuk Choi, Youngbin Kong, Hyoun-Joong Kong

cs.RO ·submitted 2026-09-22 03:52 UTC · v2
hot direction

Abstract

Closed-loop evaluation of surgical robots requires tissue that deforms, can be grasped and lifted, and reproduces the anatomy in which the robot will operate. We present a simulator in which this tissue is reconstructed from a fixed-view RGB-D recording of the surgical field, composited to remove the instruments, closed into watertight volumes and tetrahedralised; the pipeline was applied unchanged to three specimens of two species (thirteen organs, 146,061 tetrahedra, no inverted elements). For one specimen, the organs are placed in a bimanual cell in which two Franka FR3 arms operate motorised instruments through 6 mm trocars. The core contribution is the numerical and contact design that keeps this cell stable: implicit integration, simulation meshes separate from collision meshes, numerical guards, and a grasp constraint captured at the live tissue pose. In 45 repeated grasp-lifts, a friction grasp held the tissue in 0 of 15 trials and each constraint grasp in 13 of 15; on displaced tissue, a rest-pose constraint produced one-step snaps of up to 17.8 mm, which live-pose capture eliminates. Against the recording, front-surface depth error is 1.33 to 1.41 mm, organ silhouette IoU is 0.80, and in five grasp-lifts reproduced from video the landmark displacement RMSE is 11.8 mm against 14.2 mm for a static prediction. Biofidelity is not claimed; the environment is intended for closed-loop feasibility, safety, contact and policy screening.

Comment
Submitted to IEEE ICRA 2027

Closest papers

Nearest neighbours by meaning across the whole index.

Occupancy Network-Guided Autonomous Robotic Partial Nephrectomy

cs.RO cs.CV ·2026-09-14 ·Ethan Kilmer, Pit Henrich, Jiawei Ge, Paul M. Scheikl, Laura Connolly +11 more
top venue similarity 0.66
Abstract

Autonomous soft-tissue cancer surgery has been limited to interventions on organ surfaces, because current systems cannot perceive and adapt to anatomy once it deforms or is cut. We introduce the first vision-guided autonomous system capable of performing complete tumor resections for partial nephrectomy. Our system integrates conditional occupancy networks, trained entirely in a physics-based simulation, that infer full 3-D anatomy (tumor, margin tissue, and kidney) from single-view partial point clouds. These occupancy networks maintain intraoperative tracking even as tissue is cut and deformed, enabling adaptive planning and execution. The surgical platform combines a depth camera for capturing surface point clouds, dual robotic arms for electrosurgical cutting and vacuum-based tissue manipulation, and an autonomous control strategy for tumor resection. In patient-derived hydrogel phantoms under an open partial nephrectomy setting, the robot performed eight consecutive autonomous tumor resections comprising 77 electrosurgical cuts, with all cuts achieving negative surgical margins and 1.61 $\pm$ 0.48 mm mean absolute margin error. This work demonstrates, for the first time, a foundation for supervised autonomous closed-loop, imaging-driven, margin-negative tumor removal in phantoms.

0.30

Observation-Referenced Tissue Deformation Forecasting with Tool-Driven and Residual Dynamics

cs.RO ·2026-10-09 ·Tom Olesch, Nan Xiao, Xiongye Xiao, Jonathan C. DeLong, Fei Liu
similarity 0.66
Abstract · 8 pages, 6 figures, 1 table. Submitted to ICRA 2027

Forecasting tissue deformation from future instrument motion could support predictive planning and increasingly autonomous surgical systems. We study this problem using a scene-specific differentiable surface model fitted to an observed tool-tissue interaction window. Rather than forecasting absolute simulated positions, we introduce an \textit{observation-referenced} formulation that anchors each tissue point to its last valid observation and adds only the deformation induced by the known, preplanned future tool trajectory. This reduces sensitivity to reconstruction, initialization, and persistent simulation offsets while preserving the predicted deformation response. The physical model uses differentiable, mesh-free position-based dynamics with scene-specific rigidity, attachment, region scale, and grasp coupling. We further introduce an optional \textit{observation-referenced residual model} combining graph-spectral spatial modes with periodic harmonic dynamics for structured motion not explained by the tool input. We evaluate the framework retrospectively on 12 surgical manipulation clips from three datasets. Observation referencing provides the largest gain, with a median within-clip error ratio of $0.598$ relative to the corresponding absolute simulation forecast. The optional periodic residual further improves forecasting when the remaining motion exhibits periodic structure. These results support observation-referenced deformation prediction as a practical building block for future surgical world models, digital twins, and generative simulators that must predict how tissue evolves under instrument actions.

0.23

From Instrument-Mounted Demonstrations to In-Vivo Execution: Learning Bimanual Laparoscopic Appendectomy Without Robot-Collected Demonstrations

cs.RO ·2026-09-22 ·Dongho Yee, Juahn Oh, Jinseok Lee, Jiyul Lee, Yechan Seo +8 more
code/data similarity 0.65
Abstract · Submitted to IEEE ICRA 2027. Project page & Dataset: https://rosota-research.github.io/instrument-mounted-demonstrations-in-vivo/

Most minimally invasive surgery is still performed with hand-held laparoscopic instruments, and the surgeon's instrument kinematics are lost when the operation ends; only the endoscope video is kept. This paper presents an end-to-end pipeline that captures this motion in the operating room and uses it to train a surgical robot policy, validated on live animals. We introduce a surgical instrument-state logger that mounts on the shaft of a standard laparoscopic instrument and recovers its pose and jaw state from an inertial sensor, a time-of-flight sensor and a Hall sensor, with no external camera or tracker. A data pipeline measures the latency of every sensor channel against a robot ground truth and aligns the channels before forming observation-action pairs. On these demonstrations we train a diffusion policy with a fine-tuned DINOv3 backbone, selecting its design by closed-loop rollouts in a physics simulator reconstructed from depth maps of an ex-vivo rabbit appendix. The policy is then retrained on 849 in-vivo demonstrations from four live rabbits and deployed on four additional live rabbits with electrosurgery armed. With the surgeon selecting the surgical phase, the policy completed the appendectomy in three of the four animals. The results show that demonstrations recorded from a surgeon's own instruments are sufficient to train, select and deploy a bimanual surgical policy in vivo. The robot serves only as the timing reference for sensor calibration and as the executor, and collects no demonstrations. Both demonstration corpora are released to support future surgical robot learning research.

0.34

Surgical Master Console Using General-Purpose Robot Arms and a Separable Articulated Distal Interface: Porcine In-Vivo Evaluation

cs.RO ·2026-09-27 ·Minsung Kim, Seonho Shim, Dongho Yee, Younghoon Noh, Juahn Oh +7 more
similarity 0.64
Abstract · Submitted to IEEE ICRA 2027

High-performance surgical master consoles offer intuitive articulated manipulation but are expensive and difficult to reproduce, while accessible commercial haptic devices lack built-in interfaces for surgical wrist articulation and continuous grasp. We present a laparoscopic master in which general-purpose robot manipulators provide the programmable base and surgical-specific interaction is concentrated in a separable distal adapter. Each 6-DoF arm carries a custom 2-DoF direct-drive wrist, continuous grasp sensing, and clutch-based workspace management; the complete bimanual hardware costs approximately US$5,500, below common bimanual commercial haptic references. To support sustained hand-guided use, we characterize current scaling, gravity, and break-away friction and use them for posture-dependent gravity compensation and motion-gated assistance, reducing continuous actuation and thermal loading. A common master state drives either Isaac Sim or an RCM-constrained dual-FR3 platform. Master-state publication to FR3 target update adds at most 8 ms, and tip tracking shows 0.31-0.66 mm mean delay-aligned residuals. In a porcine cholecystectomy experiment, five common operator-side metrics and hand/tip-speed distributions were compared descriptively with human in-vivo telemetry from 120 clinical Versius recordings of 99 cholecystectomy procedures; no interruption originated from the master console, and no abnormal clinical signs were recorded during the 7-day postoperative observation period. These results demonstrate a surgical master built from general-purpose robot arms with surgical-specific interaction concentrated in a separable distal interface.

0.32

SimRetract: Zero-Shot Sim-to-Real Robotic Assistance for Retractor Take-Over in Open Surgery

cs.RO ·2026-10-28 ·Xucheng Wang, Zhizhou Yang, Sung Eun Kim, Romain Hardy, Michael P. Sampson +5 more
code/data similarity 0.63
Abstract

We demonstrate the first zero-shot sim-to-real transfer for a surgeon-robot collaboration task in open surgery: retractor take-over. A robot arm takes a retractor from the surgeon's hand and preserves retraction at handoff, using a policy trained only on simulated demonstrations, without human demonstrations or real-world fine-tuning. Imitation learning from real demonstrations is limited by collection and labeling costs, and by performance degradation when the environment changes. Our framework, SimRetract, generates simulated demonstrations designed for transfer: the policy observes masked instrument images and grasp geometry, learns to recover from off-nominal states, and acts with margin for execution drift. Deployed zero-shot, it grasps the retractor in 90% of 50 surgeon-defined phantom presentations and preserves retraction at handoff in 78%. Results on unseen retractors suggest potential for generalization to instruments with similar grasp geometry. Across ten policy configurations and 1,200 simulated and real trials, we localize the sim-to-real gap to components: in simulation, grasp rates across ablations span 80-96%, while on the real robot removing the instrument mask alone drops performance to 22% grasped and 12% held. Transfer-oriented design thus makes zero-shot sim-to-real transfer feasible for a surgical assistance task without human demonstrations. Code is available here: https://anonymous.4open.science/r/simretract-58D2.

0.29

ProCut: Probabilistic Cutting Topology for Autonomous Electrosurgical Tissue Dissection

cs.RO ·2026-10-05 ·Xiao Liang, Fei Liu, Florian Richter, Genie Rubaiyat, Michael Yip
similarity 0.62
Abstract

Accurately modeling and tracking the deformation of soft tissue is critical for a wide range of interventional and surgical procedures. However, current methods struggle in scenarios involving topological changes, such as cutting and dissection, due to the inherent non-linearity and discontinuity introduced by explicit changes in connectivity. In this work, we present a novel, fully differentiable framework that enables robust estimation and modeling of topological changes during deformable tracking. Our method introduces a continuous, sigmoid-based formulation to smooth the otherwise discrete event of tissue cutting, making it amenable to gradient-based optimization within a differentiable Position-Based Dynamics (PBD) simulation. To account for uncertainty and improve robustness in the presence of noisy visual data, we incorporate Stein Variational Gradient Descent (SVGD) for particle-based probabilistic inference, generating multiple hypotheses for topological state estimation. Building on this foundation, we develop an autonomous dissection algorithm for thin-shell tissues that leverages topological updates to guide closed-loop cutting trajectory control. We evaluate our approach in both simulated and real-world electrosurgical environments, demonstrating significant improvements in topological estimation accuracy and dissection precision over existing methods. Our results highlight the potential of this framework to advance automation in soft-tissue surgical procedures by enabling reliable perception and control in the presence of complex structural changes.

0.16

Robotic Optical Coherence Tomography-Guided Geometric Modeling of Soft Tissue: 3D Representations for Data-Driven Closed-Loop Shape Control

cs.RO ·2026-10-23 ·Chaoyu Zhang, Guangshen Ma, Mark Draelos
similarity 0.62
Abstract · 30 pages, 18 figures

In medical robotics, data-driven soft-tissue shape control requires deforming tissue toward desired morphologies through sequential physical interactions. This challenge is particularly important in microscale manipulation, where localized deformation is difficult to observe, represent, and control, while physics-based models can be computationally expensive and difficult to adapt to realistic environments. Optical coherence tomography (OCT) provides high-resolution volumetric perception of tissue deformation, but target-conditioned control requires effective representations of both observed and desired tissue states. In this work, we introduce an OCT-guided data-driven framework for tissue shape control, learned from user-guided demonstrations and executed with closed-loop OCT feedback. We study full-volume, tissue-masked sparse-volume, and voxelized point-cloud representations, with or without residual conditioning, using deterministic (Explicit) and generative diffusion (Diffusion) policies. Across 12 configurations and 576 phantom rollouts on 3-DoF depth and 6-DoF directional tasks, OCT-derived 3D representations support both Explicit and Diffusion policies, with performance depending on representation and residual conditioning. Residual conditioning reduces directional Shape RMSE from 0.748 to 0.555 mm for full-volume Diffusion, while voxelized point-cloud Explicit with residuals achieves 0.534 mm for depth and 0.443 mm for directional control, with comparable accuracy at intermediate unseen targets and consistent performance across deployments. We further evaluate the framework in 60 ex vivo porcine rollouts, extending to biological tissue with final geometric errors comparable to human demonstrations. These results establish volumetric OCT as current and goal representations for learned closed-loop tissue shape control across deterministic and generative action models.

0.07

Robotic Budding: From Homogeneous Cells to Diverse Morphologies in Physical Self-Reproduction

cs.RO ·2026-10-22 ·Siyuan Zhang, Junyan Liu, Wanglin He, Hod Lipson
similarity 0.62
Abstract

Physical self-reproduction in modular robots remains difficult because a robot must not only move, but also collect, align, dock, and separate modules reliably in hardware. Taking inspiration from how genetically identical cells form the varied tissues of an organism, we introduce a single standardized robotic module that combines a magnetic docking interface with two actuated joints and folds from a flat, two-dimensional configuration into three-dimensional structures. Modules of this single design can be assembled into two morphologies: a three-module "trilobite" and a five-module "seal". Using a small set of discrete motion commands, a human operator steers an assembled parent robot to dock magnetically with a sequence of spare modules, which are assembled into a second, structurally identical individual that then separates from the parent. Because the parent retains all of its original modules, this is a budding-style form of physical reproduction. Here, we report preliminary hardware demonstrations of this full process on both morphologies. We discuss the current scope of the system, including its present reliance on direct human teleoperation rather than autonomous control, and outline directions toward autonomous execution of this process and repeated validation across a larger number of independent trials.