CS Paper Radar

Lessons learned from deploying imaging AI with the open PACS-AI platform

Samuel Kadoury, Julie G. Hussin, Pascal Thériault-Lauzier, Laurent Létourneau-Guillon, Rob Lewis, Adam McArthur, Gordon J. Harris, Houda Bahig, Pierre-Luc Déziel, Jay Kshirsagar, Jacob L. Jaremko, Julien Cohen-Adad, Jacques Delfrate, Robert Avram

cs.CV cs.CY ·submitted 2026-09-22 19:18 UTC · v1

Abstract

We describe deploying imaging AI at six hospitals through PACS-AI, an open self-hosted platform. The binding constraint is not model accuracy but infrastructure to route studies, display results, capture feedback, and audit what runs. At one center, angiography models completed 515 of 607 jobs (84.8%); failures reflected absent diagnostic views, and 78.1% of 638 clinician ratings were positive. Publishing honest readiness levels for every model is itself a governance practice.

Comment
28 pages (21 main text + 7 supplementary), 3 figures, 1 table

Closest papers

Nearest neighbours by meaning across the whole index.

Can General-Purpose Generative AI Supply Training Data for Medical Vision Models? A Multimodal Retrospective Study

cs.CV cs.AI ·2026-11-07 ·Jiachuan Peng, Kyle Lam, Jierui Qu, Lin Li, Haining Zheng +8 more
similarity 0.61
Abstract

Background: Well-annotated, diverse medical imaging datasets remain a major constraint for vision-based medical AI. We evaluated Nano Banana, a general-purpose image generation and editing model, as a source of synthetic medical images for model training, subgroup augmentation, and model auditing. Methods: In this retrospective study across four imaging modalities, chest radiography, fundus photography, and CT models were trained only on synthetic images and externally validated on real-world data against real-data-trained models. Carotid ultrasound models were trained on a private Human Phenotype Project cohort (aged 40-75 years) with and without synthetic augmentation. Clinicians rated image plausibility. Evaluation used AUROC, AUPR, calibration, and decision curve analysis. Findings: Synthetic-only models achieved AUROCs of 0.877 (95% CI 0.843-0.910) for pneumonia (n=14863), 0.963 (0.948-0.975) for retinal detachment (n=1149), and 0.711 (0.600-0.823) for renal calculus (n=4122), comparable to real-data-trained models, but their calibration and net benefit were not consistently more favorable. With mixed synthetic-real training, a carotid ultrasound model produced an ordinal vascular age index that stratified 633 external subjects into subgroups differing in BMI and glucose (both p<0.01), linking vascular aging to cardiometabolic health. To stress-test shortcut learning, editing a moderate tessellated pattern into fundus photographs reduced the true-class probability for central serous chorioretinopathy from 0.996 to 0.822. Clinician-guided editing raised low-quality CT plausibility from 3.10/5 to 4.30/5. Interpretation: Synthetic data can complement real data in model training, subgroup representation, and model testing via controlled editing, but its clinical value should be assessed with calibration, decision curve analysis, and clinician review, not discrimination alone.

0.26

MedPAO-Assist: Edge-Deployable, Modality-Aware Agentic AI for Radiology Report Structuring

cs.AI ·2026-10-17 ·Shrish Shrinath Vaidya, Minmini Selvam, Ganapathy Krishnamurthi
published similarity 0.59
Abstract · The paper has been accepted at MICCAI Workshop Agentic AI for Medicine, 2026

The adoption of Large Language Models for radiology report structuring has been largely dominated by either proprietary cloud-based models or large open models requiring high-end GPUs for deployment, which is a critical bottleneck for clinical adoption in radiology workflows that demand data privacy and offline operation. To address this, we present MedPAO-Assist, an edge-deployable agentic framework that generates structured radiology reports directly from radiologist dictation and voice commands, requiring only $\approx3.3$ GB peak RAM and achieving an average end-to-end latency of $\approx31$ seconds on a standard laptop CPU through an asynchronous, multi-threaded execution pipeline. The system currently supports four major imaging modalities -- Chest X-ray, Chest CT, Abdomen CT, and Brain MRI. To our knowledge, it is among the earliest agentic systems to run its entire pipeline with a Small Language Model (SLM) in the 0.6B-parameter range. This multi-agent architecture, built around an Extract-Ground-Generate paradigm, performs concept extraction, SNOMED-CT grounding, and structured report generation, followed by a speech-driven human-in-the-loop correction phase, together forming a fully "no-touch" reporting workflow that requires no keyboard input, external API calls, or internet connectivity. We evaluate each pipeline stage individually -- concept extraction, ontology grounding, and concept categorization and report hardware profiling results demonstrating the system's feasibility for real-time, CPU-only clinical deployment.

0.24

A frontier machine intelligence for human neuroimaging

cs.AI ·2026-11-11 ·Chenhui Zhao, Akshay Rao, Akhil Kondepudi, Yiwei Lyu, Xinhai Hou +17 more
similarity 0.59
Abstract · 41 pages, 4 main figures, 9 extended data figures

Medical imaging is essential for diagnosing disease, guiding treatment and monitoring patients over time. Although artificial intelligence has advanced image interpretation, existing medical models often address restricted tasks, while general-purpose proprietary models lack access to private clinical imaging required to achieve medical expertise. Developing models that can interpret complex examinations and communicate their findings in the context of clinical decisions remains a major challenge. Here, we show that Neuro-VL, a vision-language model trained on nearly one million neuroimaging studies from routine clinical care, can interpret complete imaging examinations and engage in natural language conversations about their findings. Across internal and international datasets, Neuro-VL outperformed frontier general-purpose and specialized medical models in diagnosing, localizing, and describing abnormalities, as well as generating comprehensive radiology reports. The model also compared serial examinations to assess disease progression and more reliably resisted misleading clinical assumptions than leading frontier models from OpenAI and Google. These results extend health system learning beyond individual predictions to interactive image interpretation and longitudinal disease monitoring. They demonstrate how the collective clinical experience of health systems can be used to develop medical AI with specialized expertise and broad clinical capabilities.

0.40

CARDEA: Auditable Reasoning Grounded in Spatial Evidence for End-to-End Coronary Angiography Interpretation

cs.CV ·2026-09-07 ·Jia-Jen Lee, Shih-Yen Hou, Kee Koon Ng, Wei-Chun Wang, Shih-Sheng Chang
code/data similarity 0.58
Abstract · 25 pages, 3 figures and 4 tables in the main text; supplementary appendix with 5 figures and 1 table. Model weights: https://huggingface.co/…

Invasive coronary angiography (CAG) is the gold standard for diagnosing coronary artery disease, but interpretation varies substantially among observers. Existing AI systems can improve consistency but lack auditable decision processes and are limited in comprehensive open-ended assessment, undermining clinician trust and clinical adoption readiness. We developed CARDEA, a unified large vision-language model that serves as the inference core of a CAG pipeline. It was trained solely on public datasets and closed-ended tasks in three stages: visual feature alignment, a self-distilled Chain-of-Box (CoB) cold start, and reinforcement learning with verifiable rewards (RLVR) with a CoB reward encouraging bounding-box use in the reasoning trace. We assessed its two study-level diagnoses, dominance classification and complexity assessment, against a dedicated classifier and two interventional cardiologists. Report generation was excluded from training and evaluated zero-shot across stages on an external cohort using vessel-severity macro-$F_1$. CARDEA trailed the classifier on in-distribution dominance but drew level under domain shift (accuracy, 0.91 [95% confidence interval (CI), 0.86 to 0.95]) and was comparable to the cardiologists on complexity assessment (accuracy, 0.90 [CI, 0.82 to 0.97]). Only RLVR improved zero-shot report generation, raising its vessel-severity macro-$F_1$ (0.686 [CI, 0.664 to 0.707]) above the untuned base model (0.513) and over twice the always-normal floor (0.312). CARDEA runs an end-to-end CAG pipeline from raw multi-view videos through keyframe selection to study-level diagnosis while exposing auditable spatial evidence behind its conclusions. RLVR on verifiable closed-ended tasks surfaced open-ended reporting ability that supervised imitation did not. Clinical use requires prospective validation against expert cardiologists.

0.43

Multi-Site Real-World Performance of Commercial AI for Pulmonary and Incidental Pulmonary Embolism Detection

cs.CV cs.AI ·2026-09-29 ·Aawez Mansuri, Mohammadreza Chavoshi, Theodorus Dapamede, Wasif Bala, Beatrice Brown-Mulry +11 more
published similarity 0.58
Abstract

Pulmonary embolism (PE) is a leading cause of cardiovascular mortality, yet the real-world performance of FDA-cleared AI detection models remains incompletely characterized. We retrospectively evaluated two FDA-cleared AI algorithms from a single commercial platform (Aidoc Medical BriefCase), one for PE triage on dedicated CT pulmonary angiography (CTPA; n = 30,678) and one for incidental PE (iPE) detection on routine contrast-enhanced CTs (n = 37,191), across a 17-facility academic health system. Reference-standard labels were extracted from radiology reports using a validated LLM pipeline (97% accuracy, kappa = 0.94). The PE model achieved 86.8% sensitivity and 99.1% specificity, with sensitivity declining from 99.3% for saddle emboli to 72.9% for subsegmental PE, and from 89.7% for acute to 65.3% for non-acute PE. The iPE model achieved 73.5% sensitivity and 99.8% specificity. Both models demonstrated lower sensitivity than FDA-clearance benchmarks while exceeding cleared specificity, with diminishing performance for peripheral and non-acute emboli mirroring known human reader limitations and underscoring the need for standardized post-market surveillance of AI-enabled medical devices.

0.25

MedImageOSWorld: Benchmarking GUI Agents for Medical Image Consoles

cs.AI cs.CV ·2026-10-03 ·Ziyang Long, Xinqi Li, Lujing Xing, Hsin-Jung Yang
benchmark similarity 0.57
Abstract · 11 pages, 3 figures. Supplementary material (8 pages) included as an ancillary file

Graphical consoles offer a practical interface for medical acquisition assistance, allowing agents to work through the controls and visual feedback used by human operators. Reliable assistance requires linking on-screen anatomy to acquisition decisions that determine what image evidence becomes available next. We introduce MedImageOSWorld, a benchmark for evaluating this capability in simulated CT, MR, and ultrasound consoles. Using screenshots and mouse-and-keyboard actions, agents configure protocols, plan acquisitions, inspect the resulting images, and make corrective adjustments across seven capability levels, from console operation to feedback-driven control. Evaluation combines task-specific workflow checks with hidden anatomical ground truth to assess procedural completion and acquisition outcomes separately. A common evaluation protocol specifies episode conditions and interaction budgets, while recorded trajectories support analysis of how agents observe, act, and respond to acquisition feedback. Across eleven open-weight agents, success rates range from 3.0 to 25.0 on a 0-100 scale while workflow-progress rates reach 21.5-74.5: agents complete much of the console workflow but rarely acquire the intended anatomy. Success collapses between perception and planning, from 79-90% at the lowest three levels for the best agent to at most 12% for millimetre-level planning and 0% for closed-loop control among open-weight agents. Two proprietary agents reach success rates of about 34 and exceed the best open-weight agent mainly in acquisition quality (61 versus 42). MedImageOSWorld provides a controlled setting for studying whether general-purpose GUI agents can translate visual observations into effective medical acquisition decisions.

0.37

When Repository Labels Are Not Image-Level Truth: A Supervision Auditing Framework for Chest Radiograph AI

eess.IV cs.CV ·2026-08-10 ·Yesika Alexandra Agudelo-Londoño, Jhon Wilmer Pino-Román, Brahian Carrera Rodríguez, José Miguel Castañeda-Bedoya, Juan Pablo Gómez-López +7 more
published similarity 0.57
Abstract · Accepted (oral) at the 3rd MICCAI Student Board (MSB) EMERGE Workshop, MICCAI 2026. This is the authors' version; the final authenticated ve…

Public chest X-ray repositories are widely used to train medical AI systems, yet their labels are typically extracted from radiology reports rather than verified directly on images. As a result, repository labels are often treated as image-level ground truth without validating whether they reflect what is actually visible in the radiograph. We introduce Repository Supervision Auditing (RSA), a framework that evaluates repository-derived labels against expert image-level annotations before model development. Using cardiomegaly in MIMIC-CXR as a case study, RSA compares repository labels with radiologist-reviewed image annotations, characterizes disagreement sources, and builds a curated cohort for deployment-oriented evaluation. Repository-derived cardiomegaly labels showed near-zero agreement with expert image-level assessment, identifying only 1% of expert-confirmed cases. Most discrepancies resulted from non-mention rather than explicit report negation, with expert-confirmed cardiomegaly identified in nearly half of studies assigned a repository-derived No Finding label. Using the resulting expert-curated cohort, a DenseNet121 model achieved a test ROC-AUC of 0.853. These findings show that repository labels may not reliably represent image-level truth and highlight supervision auditing as a critical step for developing trustworthy medical imaging AI.

0.24

FRAC-MAS: A Safe and Explainable Multi-Agent System for Fracture Diagnosis

cs.AI ·2026-08-22 ·Hardik Iyer, Tirath Bhathawala, Mihir Panchal, Ying-Jung Chen, Kiran Bhowmick +2 more
publishedcode/data similarity 0.57
Abstract · Medical Image Computing and Computer Assisted Intervention (MICCAI) 2nd Workshop on Agentic AI for Medicine (AgenticMed)

Fracture detection and its clinical interpretability see notable improvements when deep vision models are integrated with agentic AI architectures. While deep learning models achieve high diagnostic performance, their black-box nature limits clinical adoption. We propose FRAC-MAS, an agentic AI system for automated, explainable, and safe bone fracture detection. The framework combines a stacked ensemble of four vision models with conformal prediction to produce statistically grounded differential diagnoses, while a multi-agent workflow performs independent verification, retrieves clinical guidelines, and generates patient-friendly reports. A pipeline-depth ablation study confirms that our multi-agent critic triages 86.6% of cases into a high-confidence auto-confirmed cohort while escalating uncertain cases, outperforming a single-agent baseline. Patient preference studies against Llama, MedGemma, and Gemini further demonstrate significantly more comprehensible clinical reports. These results suggest that integrating multi-agent critics with conformal guarantees enables safer radiology triage while preserving clinician oversight. More broadly, FRAC-MAS demonstrates how cooperative agentic architectures can serve as auditable, human-in-the-loop decision support systems for safety-critical healthcare. Our code is available at https://github.com/hardik1712/FRAC-MAS, and the website is available at https://frac-mas.vercel.app.

0.41