CS Paper Radar

A Unified Frequency-Domain Model for Cascaded Filter-Interpolation Modulation in Tomographic Reconstruction

Detian Li, Yang Zou, Penghao Geng, Shengkun Yao

eess.IV physics.optics ·submitted 2026-09-24 08:29 UTC · v1

Abstract

The fidelity of image reconstruction from projections in linear inverse problems, such as tomography, is critically dependent on the synergistic interaction between frequency-domain filtering and spatial-domain interpolation. However, a physical model that can quantitatively describe how these two components cascade interact in the frequency domain and ultimately determine image quality is still lacking to this day. Here, we introduce a unified frequency-domain model that conceptualizes the combined effect of filtering and interpolation in the filtered backprojection (FBP) algorithm as a cascaded modulation process. This model demonstrates that the effective reconstruction spectrum is determined by the original projection data being sequentially modulated by the frequency responses of the filter and the interpolation kernel. Comprehensive numerical simulations and synchrotron radiation CT experiments validate the model, confirming its power to explain the performance hierarchy of classical filter-interpolation pairs under both ideal and noisy conditions. The model successfully predicts key performance characteristics, including spatial resolution and structural fidelity, thereby elucidating the physical principles behind the efficacy of specific combinations. This work establishes a generalizable theoretical foundation for analyzing cascaded systems in linear inverse problems, moving the practice of algorithm selection in computational imaging from empiricism to a principled, physics-based paradigm.

Closest papers

Nearest neighbours by meaning across the whole index.

Informed Sinogram Interpolation for Sparse View Reconstruction

eess.IV ·2026-09-16 ·Yuejie Liu, Alessandro Lupoli, David Uribe Gallo, Andreas Fischer, Felix Krahmer
similarity 0.58
Abstract

Computed tomography (CT) has been widely used in medical examinations and non-destructive testing. Micro-CT (microfocus X-ray CT system) is an advanced version that can observe the internal structures of small objects. However, secondary radiation can prevent micro-CT from imaging the full structure of the object. Given the same amount of secondary scans as primary scans, simple subtraction solves the problem at the price of doubled acquisition time. To reduce the acquisition time, one aims to limit the secondary scans to as few imaging angles as possible and interpolate to recover the missing data. Different interpolation methods have been explored for limited-angle tomography, such as polynomial or spline interpolation, compressive sensing, deep learning, etc. In contrast to many of these scenarios, the secondary imaging setup considered in this paper often exhibits simple sinusoidal structures that are not exploited directly by any of the aforementioned approaches. This paper aims to fill this gap with a continuous mathematical model describing the secondary sinogram only with information from the projection space. Building on this model, we propose an interpolation method that effectively interpolates secondary scans from limited observations.

0.27

Taming Neural Fields with a Frequency-Lipschitz Curriculum for Sparse-View CT Reconstruction

cs.CV cs.LG ·2026-11-11 ·Songtao Hu, Jingrui Wu, Hong Ding, Fanhao Zhu, Yunhao Liu +1 more
similarity 0.58
Abstract

Sparse-view computed tomography (SVCT) reduces radiation dose by acquiring fewer projection views, but the resulting under-determined inverse problem requires careful regularization to prevent reconstruction algorithms from fitting streak artifacts and hallucinated structures. Existing implicit neural representation (INR) methods rely on implicit spectral bias or iterative external denoising, yet they provide limited control over when high-frequency capacity is exposed during optimization. To address this limitation, we propose FLIC (Frequency-Lipschitz INR Curriculum), a capacity-controlled self-prior INR framework that makes the network's representational capacity explicit and schedulable. The core of our method is a joint frequency-Lipschitz curriculum that couples random Fourier feature encoding with spectrally normalized MLP decoding under non-uniform Lipschitz budgets, guiding reconstruction along a coarse-to-fine trajectory from stable global anatomy to fine details. The terminal capacity is automatically calibrated from FBP gradient statistics, enabling scan-adaptive regularization without per-scan manual tuning of the terminal Lipschitz budget. We further introduce a prior-guided adaptive ray sampling strategy that concentrates integration samples near high-gradient anatomical boundaries, improving forward-model fidelity. The entire framework operates in a single training stage without iterative denoising, enabling efficient per-image reconstruction. Extensive experiments on four public CT datasets under noise-free and low-dose settings show that our method achieves state-of-the-art unsupervised reconstruction quality with consistent performance across diverse anatomical structures.

0.13

PSF-Informed Reconstruction: An Enhanced 2D Directional Filtered Backprojection Method for Cone-Beam Rotary Computed Laminography

cs.CV ·2026-10-31 ·Chengxiang Wang, Wei Yu, Baodong Liu
similarity 0.56
Abstract

Cone-beam rotary computed laminography (CL) presents a viable alternative to cone-beam CT for imaging objects with high aspect ratios. Conventional reconstruction techniques, such as CL-FBP and CL-FDK, often yield suboptimal results charac?terized by pronounced superimposition artifacts, reduced contrast,and blurred edges, primarily due to their reliance on 1D row-wise filtering along detector rows. To address these limitations and improve reconstruction quality, we proposed a novel 2D directional filtered backprojection (DFBP) method based on the point spread function (PSF). First, an exact expression for the projection process is derived by establishing the relationship between a reconstructed pixel and its corresponding projection point on the detector. Second, a revised backprojection process incorporating two weighting factors is introduced to counteract the nonlinearity inherent in conventional backprojection, leading to a simplified PSF formulation. Third, to circumvent the computational burden of 3D image space filtering,an approximate method by linearizing the coordinate relationship in Fourier space under some assumptions is developed that transfers the 3D filtering operation to the 2D projection space. This approach facilitates the derivation of a formally simple yet effective 2D direc?tional filter, which integrates a 2D von Hann window and a 2D sinc window. Experimental results demonstrate that the proposed method produces reconstructions with superior contrast, sharper boundaries,and fewer superimposition artifacts compared to CL-FBP and CL?FDK. Moreover, it enables more accurate recovery of internal structures, such as bubble defects and electronic components.

0.30

Tomographic Sparse View Selection using the View Covariance Loss

eess.IV ·2026-11-06 ·Jingsong Lin, Amirkoushyar Ziabari, Singanallur V. Venkatakrishnan, Obaidullah Rahman, Gregery T. Buzzard +1 more
top venuehighly cited similarity 0.56
Abstract · Accepted version of the article published in IEEE Transactions on Pattern Analysis and Machine Intelligence. 11 pages main paper plus 3 page…

Standard computed tomography (CT) reconstruction algorithms such as filtered back projection (FBP) and Feldkamp-Davis-Kress (FDK) require many views for producing high-quality reconstructions, which can slow image acquisition and increase cost in non-destructive evaluation (NDE) applications. Over the past 20 years, a variety of methods have been developed for computing high-quality CT reconstructions from sparse views. However, the problem of how to select the best views for CT reconstruction remains open. In this paper, we present a novel view covariance loss (VCL) function that measures the joint information of a set of views by approximating the normalized mean squared error (NMSE) of the reconstruction. We present fast algorithms for computing the VCL along with an algorithm for selecting a subset of views that approximately minimizes its value. Our experiments on simulated and measured data indicate that for a fixed number of views our proposed view covariance loss selection (VCLS) algorithm results in reconstructions with lower NRMSE, fewer artifacts, and greater accuracy than current alternative approaches.

0.48

Joint Image Denoising and Interpolation via Mixed Graph Filtering

eess.IV cs.CVeess.SP ·2026-11-18 ·Gene Cheung, Niruhan Viswarupan, Romisaa Elsaidy
similarity 0.55
Abstract

Images often require both denoising and interpolation, yet treating the two tasks separately is suboptimal: interpolation introduces correlated noise that complicates subsequent denoising, while denoising may remove image details useful for interpolation. In this paper, we study joint image denoising and interpolation from a mixed graph filtering perspective, where denoising is modeled using undirected graph filters and interpolation using directed graph filters. We first establish that, under mild conditions, any (pseudo-)linear denoiser and interpolator can be interpreted as solution filters of maximum a posteriori (MAP) estimation problems regularized by undirected and directed graph smoothness priors, respectively. Guided by these results, we formulate graph-based joint denoising and interpolation problems using both directed and undirected graph structures. We characterize when joint denoising/interpolation reduces to a separable pipeline and when a genuinely coupled optimization is required. For the non-separable case, we recover sparse graph operators from given denoisers and interpolators, yielding an efficient linear-system formulation solvable via conjugate gradient. Experimental results demonstrate that our proposed joint framework consistently outperforms separate denoising and interpolation pipelines across multiple denoiser-interpolator combinations.

0.23

Hexagonal Basis Projectors for Model-Based Iterative CT Reconstruction

cs.CV ·2026-10-17 ·Ke Chen, Alireza Entezari
similarity 0.54
Abstract

Image representation affects both the forward model and quantitative feature recovery in model-based iterative CT reconstruction. For isotropically bandlimited signals, the hexagonal lattice is the most sampling-efficient lattice in two dimensions, with greater directional isotropy and a larger alias-free bandwidth than the Cartesian grid at equal density. We develop constant and linear hexagonal projectors for two-dimensional fan-beam CT using box spline calculus. Both bases form a partition of unity on common coefficient centers; the linear tent also reproduces affine functions. We derive analytic ray footprints and effective detector-blur expressions and implement efficient GPU forward and backprojection. On simulated FORBILD data, the linear model improves on Cartesian and hexagonal pixels, with its best noisy-data accuracy at the coarser resolution. Real-world 2DeteCT comparisons use high-dose, high-resolution Cartesian reconstructions as pseudo ground truth and show competitive image and feature agreement. These results establish a practical hexagonal representation for quantitative CT.

0.22

Physics Guided Diffusion Model Based Exposure Interpolation for High Dynamic Range Imaging

cs.CV ·2026-10-27 ·Zhengguo Li, Chaobing Zheng
similarity 0.53
Abstract · 11 pages, 6 figures

Ghosting artifacts are an open problem for popular multi-shot based high dynamic range (HDR) imaging. An effective solution is to capture two large-exposure-ratio (LER) standard dynamic range (SDR) images simultaneously via a single-shot. Brightness order reversal (BOR) artifacts are generated when the two LER images are directly fused together. It is crucial to interpolate an image with an exposure time in between the exposure times of two LER images. In this paper, a novel physics-guided diffusion model based exposure interpolation algorithm is proposed to address the BOR artifacts. An initial image is interpolated by a physics-driven component, and the residual high-frequency details are generated by a new diffusion model based component. The new diffusion model is based on the correlation analysis of generative models and includes a new predicted target to reduce the variation of the Pearson correlation between the noisy data and the target, as well as the amplification factor of the fitting error. Compared with existing neural augmented exposure interpolation algorithms on top of convolution neural networks, the proposed exposure interpolation algorithm has an inherent advantage to generate more high frequency information. Experiment results validate the proposed exposure interpolation algorithm.

0.29

Consecutive Posterior Fusion for Diffusive Recovery of Unobservable Image Structures

cs.CV cs.AI ·2026-10-02 ·Elena Morotti, Davide Evangelista, Elena Loli Piccolomini
similarity 0.53
Abstract · 21 pages, 7 figures, 2 tables

Solving severely ill-posed imaging inverse problems requires recovering image structures that are unobservable or weakly constrained by the measurements. Diffusion models provide expressive learned priors for inferring such missing information, while posterior sampling incorporates measurement consistency along the reverse process. Standard diffusion posterior samplers, however, rely on instantaneous measurement-aware estimates, without explicitly exploiting information carried by previous posterior corrections. We introduce Consecutive Posterior Fusion Denoising Diffusion Null-Space Models (CPF-DDNM), an inference-time strategy that fuses consecutive measurement-aware estimates to improve the diffusive recovery of unobservable image structures, without requiring retraining or additional denoiser evaluations. We instantiate this principle within DDNM, whose range/null-space decomposition reveals that consecutive fusion preserves the measurement-determined component while acting exclusively on the prior-driven null-space estimate. We thus provide a geometric interpretation of CPF-DDNM and a local error analysis that characterizes the optimal time-dependent fusion coefficient, including the extrapolative regime. Experiments on sparse-view and simulated low-dose computed tomography, as well as medical image super-resolution, show consistent improvements over DDNM and competitive performance against diffusion-based inverse solvers.

0.14