CS Paper Radar

PSF-Informed Reconstruction: An Enhanced 2D Directional Filtered Backprojection Method for Cone-Beam Rotary Computed Laminography

Chengxiang Wang, Wei Yu, Baodong Liu

cs.CV ·submitted 2026-10-31 13:54 UTC · v1

Abstract

Cone-beam rotary computed laminography (CL) presents a viable alternative to cone-beam CT for imaging objects with high aspect ratios. Conventional reconstruction techniques, such as CL-FBP and CL-FDK, often yield suboptimal results charac?terized by pronounced superimposition artifacts, reduced contrast,and blurred edges, primarily due to their reliance on 1D row-wise filtering along detector rows. To address these limitations and improve reconstruction quality, we proposed a novel 2D directional filtered backprojection (DFBP) method based on the point spread function (PSF). First, an exact expression for the projection process is derived by establishing the relationship between a reconstructed pixel and its corresponding projection point on the detector. Second, a revised backprojection process incorporating two weighting factors is introduced to counteract the nonlinearity inherent in conventional backprojection, leading to a simplified PSF formulation. Third, to circumvent the computational burden of 3D image space filtering,an approximate method by linearizing the coordinate relationship in Fourier space under some assumptions is developed that transfers the 3D filtering operation to the 2D projection space. This approach facilitates the derivation of a formally simple yet effective 2D direc?tional filter, which integrates a 2D von Hann window and a 2D sinc window. Experimental results demonstrate that the proposed method produces reconstructions with superior contrast, sharper boundaries,and fewer superimposition artifacts compared to CL-FBP and CL?FDK. Moreover, it enables more accurate recovery of internal structures, such as bubble defects and electronic components.

Closest papers

Nearest neighbours by meaning across the whole index.

Model-Based Iterative Reconstruction with View-Dependent Detector Displacements for Cone-Beam CT

eess.IV ·2026-09-18 ·Doga Topcicek, Sharmin Majumder, Whitney A. Poling, Dmitriy D. Bruder, Zhili Feng +2 more
similarity 0.61
Abstract · 5 pages, 5 figures

Detector shifting is used in industrial cone-beam computed tomography to reduce ring artifacts, but the resulting detector motion can vary nonuniformly across projection views and produce detector positions that cannot be represented by fixed offsets. Although analytical reconstruction can accommodate this motion, approaches that use projection interpolation or rebinning may limit spatial resolution and introduce artifacts. MBIR provides an alternative by representing the acquisition geometry explicitly within the reconstruction model. Existing separable distance-driven MBIR formulations assume fixed detector geometry across projection views and therefore cannot directly represent nonuniform motion in both detector dimensions, as this motion changes the voxel-to-detector mapping. We extend the separable distance-driven MBIR model to incorporate recorded horizontal and vertical detector displacements into the distance-driven overlap computation while leaving measured projections unchanged. Forward-projection validation achieved an NRMSE of 0.0338 across 1080 views. The proposed model achieved a 3D SSIM of 0.9404 and NRMSE of 0.0406, compared with 0.5396 and 0.1740 for fixed-detector MBIR. A second industrial dataset showed reduced structured artifacts compared with FDK.

0.41

Field-of-View Extension in Dental Cone-Beam CT via Implicit Neural Representations and Diffusion Model-Based Refinement

cs.CV cs.AI ·2026-09-23 ·Susanne Schaub, Florentin Bieder, Matheus L. Oliveira, Yulan Wang, Buyanbileg Sodnom-ish +3 more
publishedcode/data similarity 0.59
Abstract · Accepted at MICAD 2026

Dental cone-beam computed tomography (CBCT) systems often employ detector configurations that provide a truncated field of view (FOV) that only captures a small part of the patient's anatomy. In this work, we aim to reconstruct an extended FOV using projections of truncated FOV scans. To this end, we propose a three-stage framework that consists of (1) an implicit neural representation (INR) for estimating missing parts of the truncated projection data, (2) an iterative reconstruction for generating a secondary volumetric image with improved anatomical consistency and (3) a fast diffusion model for image enhancement. The proposed approach combines the strengths of continuous representations, physics-based reconstruction and generative refinement within a unified pipeline for truncated CBCT imaging. Experimental results demonstrate that the method effectively reduces truncation artifacts, improves the reconstruction of structures extending beyond the original FOV and produces images with enhanced quality. Our code is publicly available at https://github.com/SusanneSchaub/CBCT-FOV-Extension.

0.37

EUReCA: End-to-End Unified CBCT Reconstruction Across Clinical Acquisitions

eess.IV cs.AI ·2026-10-27 ·Jiening Zhu, Chengzhu Zhang, Jason Fan, LiCheng Kuo, Weixing Cai +6 more
similarity 0.58
Abstract

Cone-beam computed tomography (CBCT) is widely used for image-guided radiotherapy, but reducing the number of projections to lower dose and scan time makes reconstruction increasingly ill-posed. We present EUReCA (End-to-end Unified REconstruction across Clinical Acquisitions), a geometry-aware feed-forward model for variable-view clinical linac CBCT. For a given acquisition trajectory, EUReCA accepts 8-100 projections with a single set of weights, without view-count-specific retraining; the same architecture and training recipe extend unchanged to other clinical trajectories. It combines learned projection features with an in-frame Feldkamp-Davis-Kress (FDK) reconstruction. The model encodes each projection with a shared multiscale backbone, back-projects features into multiresolution 3D grids using the acquisition geometry, aggregates variable numbers of views at fixed computational cost, and refines the volume with a global 3D transformer and multilevel decoder. On simulated data, EUReCA achieved 29.9-33.2 dB PSNR with 10-100 views and outperformed all applicable feed-forward baselines; it also exceeded iterative optimization-based methods while running orders of magnitude faster. On 15 measured patient CBCT scans evaluated against vendor reconstructions, EUReCA achieved the best performance at every tested view count. These results suggest that geometry-aware, measurement-anchored feed-forward reconstruction can provide a practical and flexible foundation for variable-view linac CBCT.

0.25

Hexagonal Basis Projectors for Model-Based Iterative CT Reconstruction

cs.CV ·2026-10-17 ·Ke Chen, Alireza Entezari
similarity 0.57
Abstract

Image representation affects both the forward model and quantitative feature recovery in model-based iterative CT reconstruction. For isotropically bandlimited signals, the hexagonal lattice is the most sampling-efficient lattice in two dimensions, with greater directional isotropy and a larger alias-free bandwidth than the Cartesian grid at equal density. We develop constant and linear hexagonal projectors for two-dimensional fan-beam CT using box spline calculus. Both bases form a partition of unity on common coefficient centers; the linear tent also reproduces affine functions. We derive analytic ray footprints and effective detector-blur expressions and implement efficient GPU forward and backprojection. On simulated FORBILD data, the linear model improves on Cartesian and hexagonal pixels, with its best noisy-data accuracy at the coarser resolution. Real-world 2DeteCT comparisons use high-dose, high-resolution Cartesian reconstructions as pseudo ground truth and show competitive image and feature agreement. These results establish a practical hexagonal representation for quantitative CT.

0.22

A Unified Frequency-Domain Model for Cascaded Filter-Interpolation Modulation in Tomographic Reconstruction

eess.IV physics.optics ·2026-09-24 ·Detian Li, Yang Zou, Penghao Geng, Shengkun Yao
similarity 0.56
Abstract

The fidelity of image reconstruction from projections in linear inverse problems, such as tomography, is critically dependent on the synergistic interaction between frequency-domain filtering and spatial-domain interpolation. However, a physical model that can quantitatively describe how these two components cascade interact in the frequency domain and ultimately determine image quality is still lacking to this day. Here, we introduce a unified frequency-domain model that conceptualizes the combined effect of filtering and interpolation in the filtered backprojection (FBP) algorithm as a cascaded modulation process. This model demonstrates that the effective reconstruction spectrum is determined by the original projection data being sequentially modulated by the frequency responses of the filter and the interpolation kernel. Comprehensive numerical simulations and synchrotron radiation CT experiments validate the model, confirming its power to explain the performance hierarchy of classical filter-interpolation pairs under both ideal and noisy conditions. The model successfully predicts key performance characteristics, including spatial resolution and structural fidelity, thereby elucidating the physical principles behind the efficacy of specific combinations. This work establishes a generalizable theoretical foundation for analyzing cascaded systems in linear inverse problems, moving the practice of algorithm selection in computational imaging from empiricism to a principled, physics-based paradigm.

0.25

Geometry-bridge flow matching for blind rigid-motion correction in head cone-beam CT

cs.CL physics.med-phcs.CV ·2026-11-18 ·Sungho Yun, Seungryong Cho
similarity 0.54
Abstract

Rigid motion of a patient head during head cone-beam CT (CBCT) scan can degrade image quality and complicate recovery of accurate anatomical structures from the measured projections. We present a 3D flow-matching prior approach that learns the image changes induced by motion. Its geometry-bridge connects motion-corrupted and motion-free Feldkamp-Davis-Kress (FDK) reconstructed images of the same source volume through progressively reduced simulated motion. The forward projector's geometry derivative supplies analytic velocity targets along this path. A plug-and-play loop encompasses the learned image updates together with spline-based pose estimation, conjugate-gradient data consistency, and image total-variation regularization. Both the refined image volume and the FDK reconstructed image volume at the estimated poses are evaluated. On simulated 360-view scans from 30 held-out CQ500 patients with nominal per-component motion amplitudes within 10 mm / 10 degrees, the framework achieved state-of-the-art image reconstruction quality and motion accuracy in comparison with other methos such as learned autofocus and diffusion-based joint reconstruction. Mean peak signal-to-noise ratio (PSNR) reached 37.1 dB and mean detector-plane reprojection error (RPE) was 0.27 mm. With matched endpoints at the inference settings, the geometry bridge improved PSNR by 1.6 dB and reduced RPE by 33% relative to image-linear training. With 50 prior updates and coarse-to-fine motion estimation, total processing time averaged 9.1 minutes per patient on an RTX A6000.

0.14

EPC-RawDC: Equivariant Physics Constrained 3D Diffusion with Raw Data Consistency for CBCT to CT Image Synthesis

cs.CV cs.AIphysics.med-ph ·2026-10-29 ·Alzahra Altalib, Chunhui Li, Alessandro Perelli
code/datahot direction similarity 0.54
Abstract · 10 pages, 4 figures, 8 tables

Cone beam computed tomography (CBCT) is widely used for image guided and adaptive radiotherapy, but scatter, noise, reconstruction artifacts, and inaccurate Hounsfield units limit its quantitative use. Recent diffusion approaches for CBCT to CT synthesis remain largely image driven, with limited use of the underlying acquisition physics. We propose EPC-RawDC, a conditional 3D latent diffusion framework that combines volumetric generative modeling with two complementary constraints derived from the same scanner specific CBCT forward model. First, geometry equivariant projection constraint exploits the rotational equivariance of the CBCT forward operator by supervising the synthesized CT through correspondingly transformed reference projections. Second, raw data consistency uses noisy projection measurements of the individual acquisition as scan specific supervision during training. The framework was evaluated on two independent clinical cohorts with distinct scanner geometries and projection sources. For JUST, the physics constraints used measured clinical raw CBCT projections acquired with an Elekta system, whereas for SynthRAD2025 the projection data were simulated from the reference CT using a Varian geometry with Poisson photon statistics. EPC-RawDC achieved an SSIM of 0.97 in both cohorts and improved PSNR over DDPM by 2.66 dB on SynthRAD2025 and 2.10 dB on JUST, while reducing mean MAE by 20.3% and 19.0%, respectively. On SynthRAD2025, projection consistency and equivariant errors were reduced by 55.0% and 41.4% relative to DDPM. These results demonstrate that combining a volumetric diffusion prior with scanner geometry and scan specific projection measurements improves quantitative CBCT to CT synthesis across both simulated and measured projection domains. Code available after publication at https://github.com/ALZAHRAALTALIB/EPC-RawDC.

0.37

Tomographic Sparse View Selection using the View Covariance Loss

eess.IV ·2026-11-06 ·Jingsong Lin, Amirkoushyar Ziabari, Singanallur V. Venkatakrishnan, Obaidullah Rahman, Gregery T. Buzzard +1 more
top venuehighly cited similarity 0.54
Abstract · Accepted version of the article published in IEEE Transactions on Pattern Analysis and Machine Intelligence. 11 pages main paper plus 3 page…

Standard computed tomography (CT) reconstruction algorithms such as filtered back projection (FBP) and Feldkamp-Davis-Kress (FDK) require many views for producing high-quality reconstructions, which can slow image acquisition and increase cost in non-destructive evaluation (NDE) applications. Over the past 20 years, a variety of methods have been developed for computing high-quality CT reconstructions from sparse views. However, the problem of how to select the best views for CT reconstruction remains open. In this paper, we present a novel view covariance loss (VCL) function that measures the joint information of a set of views by approximating the normalized mean squared error (NMSE) of the reconstruction. We present fast algorithms for computing the VCL along with an algorithm for selecting a subset of views that approximately minimizes its value. Our experiments on simulated and measured data indicate that for a fixed number of views our proposed view covariance loss selection (VCLS) algorithm results in reconstructions with lower NRMSE, fewer artifacts, and greater accuracy than current alternative approaches.

0.48