Model-Based Iterative Reconstruction with View-Dependent Detector Displacements for Cone-Beam CT

Doga Topcicek, Sharmin Majumder, Whitney A. Poling, Dmitriy D. Bruder, Zhili Feng, Dali Wang, Xiao Wang

eess.IV ·submitted 2026-09-18 17:25 UTC · v1

Abstract

Detector shifting is used in industrial cone-beam computed tomography to reduce ring artifacts, but the resulting detector motion can vary nonuniformly across projection views and produce detector positions that cannot be represented by fixed offsets. Although analytical reconstruction can accommodate this motion, approaches that use projection interpolation or rebinning may limit spatial resolution and introduce artifacts. MBIR provides an alternative by representing the acquisition geometry explicitly within the reconstruction model. Existing separable distance-driven MBIR formulations assume fixed detector geometry across projection views and therefore cannot directly represent nonuniform motion in both detector dimensions, as this motion changes the voxel-to-detector mapping. We extend the separable distance-driven MBIR model to incorporate recorded horizontal and vertical detector displacements into the distance-driven overlap computation while leaving measured projections unchanged. Forward-projection validation achieved an NRMSE of 0.0338 across 1080 views. The proposed model achieved a 3D SSIM of 0.9404 and NRMSE of 0.0406, compared with 0.5396 and 0.1740 for fixed-detector MBIR. A second industrial dataset showed reduced structured artifacts compared with FDK.

Comment
5 pages, 5 figures

Closest papers

Nearest neighbours by meaning across the whole index.

EUReCA: End-to-End Unified CBCT Reconstruction Across Clinical Acquisitions

eess.IV cs.AI ·2026-10-27 ·Jiening Zhu, Chengzhu Zhang, Jason Fan, LiCheng Kuo, Weixing Cai +6 more
similarity 0.65
Abstract

Cone-beam computed tomography (CBCT) is widely used for image-guided radiotherapy, but reducing the number of projections to lower dose and scan time makes reconstruction increasingly ill-posed. We present EUReCA (End-to-end Unified REconstruction across Clinical Acquisitions), a geometry-aware feed-forward model for variable-view clinical linac CBCT. For a given acquisition trajectory, EUReCA accepts 8-100 projections with a single set of weights, without view-count-specific retraining; the same architecture and training recipe extend unchanged to other clinical trajectories. It combines learned projection features with an in-frame Feldkamp-Davis-Kress (FDK) reconstruction. The model encodes each projection with a shared multiscale backbone, back-projects features into multiresolution 3D grids using the acquisition geometry, aggregates variable numbers of views at fixed computational cost, and refines the volume with a global 3D transformer and multilevel decoder. On simulated data, EUReCA achieved 29.9-33.2 dB PSNR with 10-100 views and outperformed all applicable feed-forward baselines; it also exceeded iterative optimization-based methods while running orders of magnitude faster. On 15 measured patient CBCT scans evaluated against vendor reconstructions, EUReCA achieved the best performance at every tested view count. These results suggest that geometry-aware, measurement-anchored feed-forward reconstruction can provide a practical and flexible foundation for variable-view linac CBCT.

0.25

RePrior: Measurement-Reconciled Prior Correction for Sparse-View CBCT Reconstruction

eess.IV cs.CV ·2026-10-08 ·Mengrui Yin, Tianxingjian Ding, Wufan Zhao, Ziyang Yan, Yu Tian
similarity 0.61
Abstract

Sparse-view cone-beam computed tomography (CBCT) is severely under-constrained by limited X-ray projections. Learned reconstruction can provide complementary anatomical information, but using it as a prior in patient-specific Gaussian reconstruction introduces two challenges. First, the discrepancy between the learned prior and current reconstruction is spatially non-uniform: some local differences contain useful missing 3D information, whereas others reflect prior bias. Second, even a volumetrically beneficial correction can conflict with the observed X-ray measurements. Since X-ray measurements are line integrals, spatially separated corrections may affect overlapping rays, with their signed projection responses reinforcing or partially canceling in the measurement residual, so their feasibility cannot always be assessed independently. In this paper, we introduce RePrior, a multi-stage progressive prior-correction framework that addresses correction actionability, measurement feasibility, and representation expressivity. Selective Correction Proposal (SCP) first identifies actionable signed local corrections from prior--reconstruction discrepancies. Measurement-Constrained Reconciliation (MCR) then jointly enforces their consistency with patient-specific X-ray measurements, while Hybrid Residual Enhancement (HRE) recovers additional correction capacity through complementary voxel- and Gaussian-domain degrees of freedom around the reconciled anchor. RePrior requires neither test-time ground truth nor case-specific network fine-tuning. RePrior gains approximately 2.6~dB in 3D PSNR over R$^2$-Gaussian across LUNA16, PANORAMA, and PENGWIN. Beyond prior-assisted reconstruction, it delivers additional gains in volumetric quality and observed-view projection fidelity, with consistent gains in held-out-view fidelity in the backbone-matched evaluation.

0.20

PSF-Informed Reconstruction: An Enhanced 2D Directional Filtered Backprojection Method for Cone-Beam Rotary Computed Laminography

cs.CV ·2026-10-31 ·Chengxiang Wang, Wei Yu, Baodong Liu
similarity 0.61
Abstract

Cone-beam rotary computed laminography (CL) presents a viable alternative to cone-beam CT for imaging objects with high aspect ratios. Conventional reconstruction techniques, such as CL-FBP and CL-FDK, often yield suboptimal results charac?terized by pronounced superimposition artifacts, reduced contrast,and blurred edges, primarily due to their reliance on 1D row-wise filtering along detector rows. To address these limitations and improve reconstruction quality, we proposed a novel 2D directional filtered backprojection (DFBP) method based on the point spread function (PSF). First, an exact expression for the projection process is derived by establishing the relationship between a reconstructed pixel and its corresponding projection point on the detector. Second, a revised backprojection process incorporating two weighting factors is introduced to counteract the nonlinearity inherent in conventional backprojection, leading to a simplified PSF formulation. Third, to circumvent the computational burden of 3D image space filtering,an approximate method by linearizing the coordinate relationship in Fourier space under some assumptions is developed that transfers the 3D filtering operation to the 2D projection space. This approach facilitates the derivation of a formally simple yet effective 2D direc?tional filter, which integrates a 2D von Hann window and a 2D sinc window. Experimental results demonstrate that the proposed method produces reconstructions with superior contrast, sharper boundaries,and fewer superimposition artifacts compared to CL-FBP and CL?FDK. Moreover, it enables more accurate recovery of internal structures, such as bubble defects and electronic components.

0.30

EPC-RawDC: Equivariant Physics Constrained 3D Diffusion with Raw Data Consistency for CBCT to CT Image Synthesis

cs.CV cs.AIphysics.med-ph ·2026-10-29 ·Alzahra Altalib, Chunhui Li, Alessandro Perelli
code/datahot direction similarity 0.60
Abstract · 10 pages, 4 figures, 8 tables

Cone beam computed tomography (CBCT) is widely used for image guided and adaptive radiotherapy, but scatter, noise, reconstruction artifacts, and inaccurate Hounsfield units limit its quantitative use. Recent diffusion approaches for CBCT to CT synthesis remain largely image driven, with limited use of the underlying acquisition physics. We propose EPC-RawDC, a conditional 3D latent diffusion framework that combines volumetric generative modeling with two complementary constraints derived from the same scanner specific CBCT forward model. First, geometry equivariant projection constraint exploits the rotational equivariance of the CBCT forward operator by supervising the synthesized CT through correspondingly transformed reference projections. Second, raw data consistency uses noisy projection measurements of the individual acquisition as scan specific supervision during training. The framework was evaluated on two independent clinical cohorts with distinct scanner geometries and projection sources. For JUST, the physics constraints used measured clinical raw CBCT projections acquired with an Elekta system, whereas for SynthRAD2025 the projection data were simulated from the reference CT using a Varian geometry with Poisson photon statistics. EPC-RawDC achieved an SSIM of 0.97 in both cohorts and improved PSNR over DDPM by 2.66 dB on SynthRAD2025 and 2.10 dB on JUST, while reducing mean MAE by 20.3% and 19.0%, respectively. On SynthRAD2025, projection consistency and equivariant errors were reduced by 55.0% and 41.4% relative to DDPM. These results demonstrate that combining a volumetric diffusion prior with scanner geometry and scan specific projection measurements improves quantitative CBCT to CT synthesis across both simulated and measured projection domains. Code available after publication at https://github.com/ALZAHRAALTALIB/EPC-RawDC.

0.37

Hexagonal Basis Projectors for Model-Based Iterative CT Reconstruction

cs.CV ·2026-10-17 ·Ke Chen, Alireza Entezari
similarity 0.60
Abstract

Image representation affects both the forward model and quantitative feature recovery in model-based iterative CT reconstruction. For isotropically bandlimited signals, the hexagonal lattice is the most sampling-efficient lattice in two dimensions, with greater directional isotropy and a larger alias-free bandwidth than the Cartesian grid at equal density. We develop constant and linear hexagonal projectors for two-dimensional fan-beam CT using box spline calculus. Both bases form a partition of unity on common coefficient centers; the linear tent also reproduces affine functions. We derive analytic ray footprints and effective detector-blur expressions and implement efficient GPU forward and backprojection. On simulated FORBILD data, the linear model improves on Cartesian and hexagonal pixels, with its best noisy-data accuracy at the coarser resolution. Real-world 2DeteCT comparisons use high-dose, high-resolution Cartesian reconstructions as pseudo ground truth and show competitive image and feature agreement. These results establish a practical hexagonal representation for quantitative CT.

0.22

Task-driven sparse-view planar X-ray computed tomography for axial metrology

eess.IV cs.CV ·2026-11-01 ·Yibin Tian, Shuming Yang, Wolfgang Heidrich
similarity 0.58
Abstract

Computational imaging can reduce the acquisition burden when the system is designed around task-relevant information rather than complete image recovery. We investigate this framework for sparse-view planar X-ray tomography (XCT) of layered objects, using measurement of the axial termination gap (ATG) of back-drilled printed-circuit-board (PCB) vias as a representative task. Instead of using 3D reconstruction, the proposed method estimates ATG directly from polychromatic projection data through a physics-based sensitivity model. A gated hierarchical estimator first fits ATG together with radiometric perturbations and selectively introduces global geometry and specimen-warp models only when a reduced chi-squared adequacy test and Bayesian information criterion justify the added degrees of freedom. The same low-dimensional perturbation model is incorporated into marginalized Fisher-information analyses, yielding task-specific conditional and calibration-aware Cram'er-Rao bounds. Numerical experiments show that, under a fixed total photon budget, task-driven metrology changes little over 12-64 views, while reconstruction-driven metrology is strongly view-dependent with much larger errors. The direct estimator also follows the expected photon-limited scaling. These results demonstrate a computational sensing strategy in which XCT acquisition, physical modeling, and inference are evaluated according to the quantitative information required by the task rather than for general-purpose volumetric image fidelity.

0.25

View optimization in Computed Tomography

eess.IV ·2026-11-02 ·Seemeen Karimi, Christopher McGuire
published similarity 0.58
Abstract · All figures are in the PDF. presented at a conference, conference proceedings pending

Many emerging CT imaging applications must operate with data from sparse projection angles, on the order of 10 views, such as first responder scenarios, dynamic imaging of detonation events, and flash imaging of materials under extreme conditions in high energy-density science. Few-view imaging is a data undersampling problem, that degrades tomographic reconstructions with streaks, shadows, and other aliasing artifacts, due to ill-conditioning. In few- view CT, the specific set of projection angles can strongly impact reconstruction quality, and the optimal angles depend on the object being scanned. Despite a surge of recent research, there is much to explore in this problem. We present an object-aware performance prediction framework for few-view projection datasets based on a matrix decomposition of the discretized forward model augmented with expected object gradient information. The method yields a quantitative score for a candidate set of view angles that can underpin a view selection recommendation algorithm. A key feature is that it can be applied at multiple stages of acquisition: a priori, before any radiographs are taken, or adaptively, after some radiographs are collected, to determine the next best view. We demonstrate the approach using simulated CT data with 5 view and 15 view configurations. Preliminary results are encouraging; images reconstructed using a standard statistical algorithm show that reconstruction accuracy agrees with our performance score. Reconstruction accuracy was evaluated against a known ground truth using an information theoretic score. Continued testing with complex objects and multiple geometries is necessary.

0.14

Field-of-View Extension in Dental Cone-Beam CT via Implicit Neural Representations and Diffusion Model-Based Refinement

cs.CV cs.AI ·2026-09-23 ·Susanne Schaub, Florentin Bieder, Matheus L. Oliveira, Yulan Wang, Buyanbileg Sodnom-ish +3 more
publishedcode/data similarity 0.58
Abstract · Accepted at MICAD 2026

Dental cone-beam computed tomography (CBCT) systems often employ detector configurations that provide a truncated field of view (FOV) that only captures a small part of the patient's anatomy. In this work, we aim to reconstruct an extended FOV using projections of truncated FOV scans. To this end, we propose a three-stage framework that consists of (1) an implicit neural representation (INR) for estimating missing parts of the truncated projection data, (2) an iterative reconstruction for generating a secondary volumetric image with improved anatomical consistency and (3) a fast diffusion model for image enhancement. The proposed approach combines the strengths of continuous representations, physics-based reconstruction and generative refinement within a unified pipeline for truncated CBCT imaging. Experimental results demonstrate that the method effectively reduces truncation artifacts, improves the reconstruction of structures extending beyond the original FOV and produces images with enhanced quality. Our code is publicly available at https://github.com/SusanneSchaub/CBCT-FOV-Extension.

0.37