CS Paper Radar

Towards Transparent Diagnostics: Investigating Architectural Trade-offs and Explainability in Malaria Detection

Suman Kunwar, Avishek Dangol

cs.CV ·submitted 2026-09-16 13:24 UTC · v2

Abstract

More than 80 countries have reported malaria cases with 610 thousand deaths and are projected to increase. Identifying malaria early and accurately helps save lives and effective way to diagnose malaria is through microscopic methods that are labor intensive and require experts with special equipment. Deep learning (DL) has shown promising results in medical diagnosis. Here, we explored various DL models: ResNet18, MobileNetV2, EfficientNet-B2, VGG19 and proposed model ResNet18+TTA (ResNet18 backbone with modified classification head and test time augmentation) for detecting malaria presence using blood smears taken from the NIH Malaria dataset. Our experiment shows MobileNetV2 achieved 96.85 % accuracy with smallest model size (8.49 MB) and fastest inference (1.35 ms). The ResNet18+TTA model achieved 97.96 % accuracy, 0.996 AUC with longest inference time (13.32 ms). Larger architecture outputs a larger model size with moderate accuracy. Upon further pruning, ResNet18+TTA model gained a slight improvement in accuracy and reduced inference time. GRAD-CAM, SHAP and LIME provide explainable AI (XAI) insights into model predictions, using explanation agreement and divergence to evaluate predictive reliability.

Comment
14 pages, 10 figures

Closest papers

Nearest neighbours by meaning across the whole index.

EMFE: A lightweight, explainable machine learning framework for malaria cell classification

cs.CV ·2026-08-25 ·Md Abdullah Al Kafi, Walayat Hussain, Mousumi Karmakar, Sumit Kumar Banshal, Ahmed Al Marouf
similarity 0.71
Abstract

Automated malaria diagnosis from stained blood-smear microscopy is dominated by deep convolutional neural networks that are accurate but computationally expensive, poorly interpretable, and rarely validated with patient-level rigor. We present EMFE (Efficient Mathematical Feature Extraction), a five-feature framework for classifying single red-blood-cell images as parasitized or uninfected using Gray World color normalization, adaptive green-channel thresholding, morphological spot detection, and classical machine learning. Using the NIH LHNCBC malaria dataset (27,558 images from 200 patients), we evaluate Random Forest, Histogram Gradient Boosting, and Support Vector Machine classifiers under patient-grouped nested cross-validation (K_outer=20, K_inner=3), ensuring that cells from each patient remain within a single fold. The optimized Random Forest achieves 94.6% pooled out-of-fold accuracy (95% CI [93.6, 95.7]), corroborated by an untouched 40-patient holdout test (94.3%) and a patient-level permutation test (p<0.001, 1,000 permutations). Ablation experiments quantify the contribution of individual features and pipeline stages. Hardware-matched comparisons with retrained DenseNet121, ResNet50, and MobileNetV2 models assess the accuracy-efficiency trade-off. Synthetic perturbations characterize three failure modes, while explainability analysis identifies spot saturation as the dominant discriminative feature. Patient-level aggregation further quantifies sensitivity-specificity trade-offs and false-positive accumulation. These results demonstrate a statistically rigorous, interpretable, and computationally lightweight alternative to deep learning, while explicitly quantifying its limitations.

0.24

Parallel Training Using a CNN-DNN Architecture for Accelerated Development of Diagnostic Models

cs.CV ·2026-09-11 ·Janine Weber-Hamacher, Astha Jaiswal, Philipp Fervers, Dorotya Móré, Athanasios Giannakis +6 more
similarity 0.70
Abstract

Artificial intelligence has shown promise in assisting radiologists in imaging-based diagnosis across a wide range of diseases. Efficient training of large deep learning models is essential to cope with extremely large data sets or dynamically growing disease data, like in a pandemic like situation. In this retrospective study, we collected 300 CT scans from COVID-19 and non-COVID-19 pneumonia patients from three different centers in Germany. We investigated a hybrid CNN-DNN network model based on image decomposition and localization that naturally supports parallel and efficient training of deep learning models. In total, 156 models with three different architectures were trained to capture features at different levels resulting in 12 patient-level COVID-19 diagnosis models. Diagnostic performance as well as time saving were measured. The highest accuracy was obtained from DenseNet121 and 3D CNN models with a parallel CNN-DNN approach, resulting in $88.78\%$ training, $76.67\%$ validation and $76.03\%$ test accuracy for the DenseNet121 with $4\times4\times1$ subdomains and $87.72\%$ training, $76.82\%$ validation and $74.86\%$ test accuracy, respectively, for the 3D CNN with $4\times4\times1$ subdomains. The strongest reduction in parallel training time by a factor of $31$ was observed for the 3D CNN model and $4\times4\times2$ subdomains. Our parallel training approach improves efficiency as well as performance enabling rapid model development, among others crucial for pandemic preparedness.

0.27

Safety-Constrained Cascade Inference for Robust Malaria Cell Classification Under Field Corruptions

cs.CV ·2026-09-26 ·J. T. Hagbe, Michel Emel
code/data similarity 0.69
Abstract · 28 pages, 6 figures, 8 tables. Code available at https://github.com/josehagbe3/MalariaVision

Automated malaria diagnosis from thin blood-smear microscopy could meaningfully reduce the burden on under-resourced laboratories, but a model that maximises accuracy on clean laboratory images fails badly the moment an inexpensive smartphone camera introduces sensor noise. This paper introduces MalariaCascade, a two-stage inference system in which a lightweight MobileNetV2 sentinel (2,225,153 parameters) makes confident classifications at low compute cost and escalates uncertain cases to an EfficientNet-B3 expert (10,697,769 parameters) that sees only clean, standardised images regardless of how corrupted the incoming frame is. Structural isolation of the expert stage, not learned robustness, is the mechanism. The sentinel is trained under a safety-score objective that places an explicit floor on Recall(Parasitised) (>=0.95) and Recall(Uninfected) (>=0.40) before precision is optimised, ensuring the checkpoint satisfies clinical safety constraints by construction. On the NIH Malaria Cell Images Dataset (27,558 cells), the cascade reaches Accuracy=0.9736, Recall(Parasitised)=0.9570, Precision(Parasitised)=0.9912, F1=0.9738, and AUROC=0.9955 on the clean test set. Under Gaussian sensor noise at full severity, cascade Recall(Parasitised) degrades by only 2.4 pp (0.9570 to 0.9329), while the flat single-model baseline collapses by 63.0 pp (0.9584 to 0.3281). McNemar's test confirms the cascade improvement is statistically significant (chi^2=11.14, p=0.00085). An ablation isolating the structural property shows that routing clean images to the expert is responsible for a 16.8 pp Recall(Parasitised) advantage under sensor noise relative to a cascade where the expert also sees corrupted inputs.

0.33

Interpretable Deep Learning Models for Breast Cancer Diagnosis Using Medical Imaging

cs.CV cs.AI ·2026-10-27 ·Sami Alnawali, Muhammad Atif Saeed, Abdul Hadi, Azka Atiq, Akhtar Jamil +1 more
benchmark similarity 0.67
Abstract · 37 page, 45 Figures

Deep learning shows promise for breast cancer diagnosis, but limited interpretability hinders clinical adoption. We benchmark ten ImageNet-pretrained models (ResNet50, VGG19, InceptionV3, DenseNet121, Xception, MobileNetV2, EfficientNet, ConvNeXt, ViT, and Swin Transformer) for benign-versus-malignant classification on the BreakHis histopathology dataset using a patient-level split, and explain their predictions with Grad-CAM, LIME, Integrated Gradients, and LRP. DenseNet121 performed best, with 99.4% test accuracy and an AUC-ROC of 0.999, and significantly outperformed all other models (p < 0.001). Transformer-based models trailed the CNNs. The explanations consistently highlighted nuclei-rich and glandular regions of diagnostic relevance. Combining transfer learning with explainable AI can thus yield accurate, interpretable tools for breast cancer diagnosis.

0.19

How well do routinely collected demographic and clinical variables aid point-of-care lung ultrasound TB classification

eess.IV cs.CVcs.LG ·2026-10-05 ·Joshua M. Jansen van Vüren, Christiaan M. Geldenhuys, Devendra S. Parihar, Véronique Suttels, Trevor Brokowski +5 more
published similarity 0.66
Abstract · Accepted: SATNAC, Drakensberg, South Africa, 2026

We consider the fusion of lung ultrasound images with routinely-collected clinical and demographic data for the purpose of automated tuberculosis (TB) screening using deep-learning. Such deep-learning based screening tools for TB could meaningfully support the health care system in Africa, where the burden of disease is severe and resources are constrained. Beginning with an established ResNet baseline for classification of lung ultrasound images, which achieves an area under the receiver operating characteristic (AUROC) curve of 0.91 [0.86,0.96] (95% CI), we consider the incorporation of the clinical and demographic data using three fusion approaches. We find that a simple average-based fusion of the output scores of separately-trained image and clinical data classifiers consistently matches or outperforms a more complex approach where the data is fused earlier and a combined classifier is trained. Fusing the image and the clinical classifiers in this way leads to a classifier with an overall AUROC of 0.95 [0.91,0.99] (specificity of 0.76 at sensitivity 0.93) which is an improvement of 4% absolute over the image-only baseline. We also find that greedy feature selection can be used to reduce the number of clinical and demographic inputs without sacrificing classification performance. Finally, when we differentiate between clinical and demographic data that are self-reported, that require some basic measurement or calculation, and that require a point-of-care (POC) test, we find the inclusion of the POC tests included in this study to be of minimal benefit to classification performance. We conclude that the incorporation of routinely-collected clinical and demographic data is a promising way to improve the performance of lung ultrasound based automatic classification.

0.25

Architecture-aware Robustness Evaluation of Explainable Deep Learning for Breast Cancer Diagnosis

cs.CV ·2026-09-18 ·Balenthira Thanusanth, Selvarajah Thuseethan, Roshan G. Ragel, Bimali S. Weerakoon, Ayesh Jayasinghe +1 more
code/data similarity 0.65
Abstract · 12 pages, 7 figures

Explainable Artificial Intelligence (XAI) has become essential in medical image analysis to ensure transparency of deep learning (DL)-based diagnostic systems. However, selecting appropriate XAI techniques for breast cancer recognition remains largely ad hoc, with limited systematic evaluation across different DL architectures. This study presents a systematic architecture-aware evaluation protocol to assess the effectiveness of nine widely used XAI techniques across four categories of DL models: very deep, lightweight, transformer-based and hybrid neural networks. The evaluation is conducted on a breast ultrasound dataset comprising 780 images using clinically aligned spatial metrics, including Pointing Game, Intersection over Union and Mean Coverage, to quantify agreement between generated explanations and expert-annotated lesion regions. Results indicate that explanation quality is primarily influenced by the interaction between model architecture and XAI method, rather than any single technique consistently outperforming others. Hybrid architectures produce more spatially coherent explanations, while lightweight and transformer-based models exhibit greater variability across methods. The findings show that no single technique generalises across architectures and evaluation criteria, emphasising the need for joint selection of DL models and XAI techniques. Explainability depends on both model design and explanation strategy and should not be considered independently. This work provides a structured evaluation protocol and practical guidance for selecting XAI techniques in breast cancer diagnosis, supporting more transparent clinical decision-support systems. \textcolor{blue}{Code is publicly available at https://github.com/Nishan-Charlie/Explainable-AI}

0.29

Robust Lightweight Deep Learning Models for Oral Cancer Screening

cs.AI ·2026-08-21 ·Siddhant Bharadwaj, Aakash Shedsale, Tejashree Subramanya, Mohd. Azfar, Praveen Birur +4 more
published similarity 0.65
Abstract · 10 pages, 3 figures, Paper accepted for the 6th International Conference on AI-ML Systems, 2026

Oral cancer is a leading cause of mortality in low-to-middle-income countries, where a shortage of specialists delays diagnosis. While point-of-care screening via smartphones offers a scalable solution, developing robust AI for resource-constrained settings poses significant challenges, including class imbalance in training data, variable data quality, and computational constraints on edge devices. In this paper, we present the optimisation of lightweight deep learning models for smartphone-based oral cancer screening. Using a diverse, multi-centre retrospective dataset of approximately 30,000 images acquired over a decade, we systematically evaluate state-of-the-art convolutional, transformer, and hybrid architectures. Through rigorous pipeline ablation, we demonstrate that directly optimising hybrid architectures for the edge strictly outperforms computationally heavy paradigms, such as large models or knowledge distillation. Furthermore, interpretability analysis and simulated noise-stress tests revealed that the system anchors on clinical features and remains robust to unstructured sensor noise, despite vulnerabilities to impulse bit errors. In the held-out test set, our optimised MobileViTv2 models achieved an average sensitivity of 83.2 $\pm$ 1.5% and an average specificity of 86.0 $\pm$ 0.8%, with the best model exhibiting 87.4% sensitivity, 86.5% specificity, and a critical negative predictive value of 97.2% with reference to specialist labels. These results confirm that with targeted architectural selection and streamlined optimisation, interpretable and robust lightweight AI models exhibit high potential for edge deployment to enable automated triage in primary care settings.

0.30

CoAtNet-DeepMoE: A Convolution-Attention Hybrid with DeepSeek Mixture-of-Experts for Parameter-Efficient Tomato Disease Classification

cs.CV ·2026-09-16 ·Md Nadim Mahamood, Md Arif Shahriar, Md Shafi Ud Doula, Kamrul Hasan
code/data similarity 0.65
Abstract · 16 pages, 8 tables, 6 figures

The world population is growing rapidly, and technology is improving in parallel. Meeting the huge demand for food for these 7 billion people not only depends on increasing food production but also on reducing food loss. Crop losses due to disease affect both the food supply and the financial and economic stability of a country. Tomatoes are among the top food-producing crops globally, and a significant portion of this production is lost due to disease. People have used Machine Learning techniques for feature extraction and early diagnosis of tomato diseases, and nowadays, Deep Learning-based models are widely used for disease recognition. However, most existing models are highly parameter-intensive, which increases the time required for training and inference. As a result, while lightweight models are more suitable for user-friendly applications, they often show a reduction in performance. To balance performance and model size, we propose CoAtNet-DeepMoE, a Convolution-Attention hybrid architecture for rich feature extraction, further enhanced with a DeepSeek Mixture of Experts to substantially reduce the number of parameters without sacrificing accuracy. We evaluate our model on both balanced and imbalanced datasets from Kaggle and PlantVillage, demonstrating robustness and achieving 99.80% accuracy, 99.80% precision, 99.80% recall, and 99.80% F1-score on Kaggle, and 99.83% accuracy, 99.85% precision, 99.76% recall, and 99.80% F1-score on PlantVillage, representing state-of-the-art performance with only 2.47M parameters. The source code will be available at https://github.com/nadimbrur/CoAt-MoE.

0.39