CS Paper Radar

Safety-Constrained Cascade Inference for Robust Malaria Cell Classification Under Field Corruptions

J. T. Hagbe, Michel Emel

cs.CV ·submitted 2026-09-26 22:58 UTC · v1
code/data

Abstract

Automated malaria diagnosis from thin blood-smear microscopy could meaningfully reduce the burden on under-resourced laboratories, but a model that maximises accuracy on clean laboratory images fails badly the moment an inexpensive smartphone camera introduces sensor noise. This paper introduces MalariaCascade, a two-stage inference system in which a lightweight MobileNetV2 sentinel (2,225,153 parameters) makes confident classifications at low compute cost and escalates uncertain cases to an EfficientNet-B3 expert (10,697,769 parameters) that sees only clean, standardised images regardless of how corrupted the incoming frame is. Structural isolation of the expert stage, not learned robustness, is the mechanism. The sentinel is trained under a safety-score objective that places an explicit floor on Recall(Parasitised) (>=0.95) and Recall(Uninfected) (>=0.40) before precision is optimised, ensuring the checkpoint satisfies clinical safety constraints by construction. On the NIH Malaria Cell Images Dataset (27,558 cells), the cascade reaches Accuracy=0.9736, Recall(Parasitised)=0.9570, Precision(Parasitised)=0.9912, F1=0.9738, and AUROC=0.9955 on the clean test set. Under Gaussian sensor noise at full severity, cascade Recall(Parasitised) degrades by only 2.4 pp (0.9570 to 0.9329), while the flat single-model baseline collapses by 63.0 pp (0.9584 to 0.3281). McNemar's test confirms the cascade improvement is statistically significant (chi^2=11.14, p=0.00085). An ablation isolating the structural property shows that routing clean images to the expert is responsible for a 16.8 pp Recall(Parasitised) advantage under sensor noise relative to a cascade where the expert also sees corrupted inputs.

Comment
28 pages, 6 figures, 8 tables. Code available at https://github.com/josehagbe3/MalariaVision

Closest papers

Nearest neighbours by meaning across the whole index.

Towards Transparent Diagnostics: Investigating Architectural Trade-offs and Explainability in Malaria Detection

cs.CV ·2026-09-16 ·Suman Kunwar, Avishek Dangol
similarity 0.69
Abstract · 14 pages, 10 figures

More than 80 countries have reported malaria cases with 610 thousand deaths and are projected to increase. Identifying malaria early and accurately helps save lives and effective way to diagnose malaria is through microscopic methods that are labor intensive and require experts with special equipment. Deep learning (DL) has shown promising results in medical diagnosis. Here, we explored various DL models: ResNet18, MobileNetV2, EfficientNet-B2, VGG19 and proposed model ResNet18+TTA (ResNet18 backbone with modified classification head and test time augmentation) for detecting malaria presence using blood smears taken from the NIH Malaria dataset. Our experiment shows MobileNetV2 achieved 96.85 % accuracy with smallest model size (8.49 MB) and fastest inference (1.35 ms). The ResNet18+TTA model achieved 97.96 % accuracy, 0.996 AUC with longest inference time (13.32 ms). Larger architecture outputs a larger model size with moderate accuracy. Upon further pruning, ResNet18+TTA model gained a slight improvement in accuracy and reduced inference time. GRAD-CAM, SHAP and LIME provide explainable AI (XAI) insights into model predictions, using explanation agreement and divergence to evaluate predictive reliability.

0.19

MORPHA: Morphology-Constrained Training and the Limits of Cross-Acquisition Transfer in Low-Resource Malaria Microscopy

cs.CV ·2026-09-05 ·Favour Okechukwu Igwezeke, Chikodili Helen Ugwuishiwu, Joseph Uzochukwu Emesiani, Samuel Ifebuche Agada, Ekenechukwu Lilian Anozie +2 more
published similarity 0.67
Abstract · 11 pages, 2 figures. Author-submitted manuscript prior to peer review. The work was accepted for poster presentation at MIRASOL 2026, a MICC…

In low-resource malaria microscopy, a model trained on one smear preparation routinely meets images from another, and how well morphology-based constraints transfer across this acquisition gap is unclear. We study this on real African field microscopy from Uganda (Lacuna), asking where encoding measured parasite morphology as a training constraint improves cross-acquisition transfer and where generic regularisation suffices. We present MORPHA, a morphological consistency constraint that derives stage-conditional statistics from the stage-annotated BBBC041 dataset and penalises predictions that deviate from them. Defined uniformly across binary, object-level, and stage-aware regimes without changing architecture or inference, it shapes training in the binary regime. The detection regime is a mapped boundary. On transfer from thin-smear cells to thick-smear field images, the constraint reduces the binary-classification generalisation drop by 30.8% (F1 0.578 to 0.699) at negligible within-domain cost and lowers in-distribution calibration error by 49% (ECE 0.0162 to 0.0082). A content-free control applying the identical constraint to random statistics recovers less of the drop (25.3% vs 30.8%), indicating the measured content, not constraining alone, contributes to the gain. Two standard confidence regularisers exceed the constraint on raw transfer, locating where morphology adds value and where generic regularisation suffices. We map two deployment-relevant boundaries: thin-smear statistics do not transfer to thick-smear detection (trophozoite AP@0.50 falls to 0.000), and cross-acquisition pseudo-labelling fails before filtering applies. Together these yield a morphology-grounded consistency signal and evidence-based guidance for malaria dataset and model design in low-resource settings.

0.27

EMFE: A lightweight, explainable machine learning framework for malaria cell classification

cs.CV ·2026-08-25 ·Md Abdullah Al Kafi, Walayat Hussain, Mousumi Karmakar, Sumit Kumar Banshal, Ahmed Al Marouf
similarity 0.63
Abstract

Automated malaria diagnosis from stained blood-smear microscopy is dominated by deep convolutional neural networks that are accurate but computationally expensive, poorly interpretable, and rarely validated with patient-level rigor. We present EMFE (Efficient Mathematical Feature Extraction), a five-feature framework for classifying single red-blood-cell images as parasitized or uninfected using Gray World color normalization, adaptive green-channel thresholding, morphological spot detection, and classical machine learning. Using the NIH LHNCBC malaria dataset (27,558 images from 200 patients), we evaluate Random Forest, Histogram Gradient Boosting, and Support Vector Machine classifiers under patient-grouped nested cross-validation (K_outer=20, K_inner=3), ensuring that cells from each patient remain within a single fold. The optimized Random Forest achieves 94.6% pooled out-of-fold accuracy (95% CI [93.6, 95.7]), corroborated by an untouched 40-patient holdout test (94.3%) and a patient-level permutation test (p<0.001, 1,000 permutations). Ablation experiments quantify the contribution of individual features and pipeline stages. Hardware-matched comparisons with retrained DenseNet121, ResNet50, and MobileNetV2 models assess the accuracy-efficiency trade-off. Synthetic perturbations characterize three failure modes, while explainability analysis identifies spot saturation as the dominant discriminative feature. Patient-level aggregation further quantifies sensitivity-specificity trade-offs and false-positive accumulation. These results demonstrate a statistically rigorous, interpretable, and computationally lightweight alternative to deep learning, while explicitly quantifying its limitations.

0.24

CoSWA-YOLOv12: Scale-Invariant Tiny Object Detection and Segmentation of Malaria Parasites

cs.CV cs.AI ·2026-08-25 ·Ahmed Tahiru Issah, Carine Mukamakuza
published similarity 0.61
Abstract · Accepted at The 3rd MIRASOL workshop, a satellite event at MICCAI 2026. To appear in Springer Lecture Notes in Computer Science (LNCS)

Automated microscopy could widen access to malaria diagnosis in low-resource settings, but the deadliest species, P. falciparum, presents in its early ring stage as an object only a few tens of pixels wide. Such tiny targets are systematically under-detected: overlap-based label assignment starves them of positive samples, and overlap-based box regression gives weak gradients at their scale. The Normalized Gaussian Wasserstein Distance (NWD) repairs both effects, but applied uniformly across a slide that also holds objects three to four times larger it loosens their supervision and erodes their localisation, so overall accuracy can fall even as the tiny class improves. We present CoSWA-YOLOv12, a compact YOLOv12 instance-segmentation detector whose core Cooperative Scale-adaptive Wasserstein Assignment routes the Wasserstein treatment to an object in inverse proportion to its size, tapering back to standard assignment for larger species. Two further components support it: a wavelet detail residual, and a min-max Gaussian regression loss (M2-NWD). All three additions are transfer-safe: each reproduces the standard pretrained model exactly at initialisation, so public pretrained weights load without any loss of accuracy. On a five-class Rwandan thick-smear dataset, CoSWA-YOLOv12 raises P. falciparum recall from 0.63 to 0.74 and mAP@50 from 0.73 to 0.81 (mask), cuts missed P. falciparum from 38% to 15%, and improves strict-localisation mAP@50-95 on all five classes for both detection and segmentation, while a 2x2 ablation shows the scale gate and the regression loss are synergistic.

0.63

Investigating White Blood Cells as a Source of False-Positive Malaria Parasite Detection in African Blood-Smear Images

cs.CV cs.AI ·2026-08-30 ·Samuel A. Adeniji, Goodness C. Obasi, Chris-Victor Ntwali, Aondana M. Iorumbur, Confidence Raymond +2 more
published similarity 0.60
Abstract · Accepted at the 3rd MIRASOL workshop, a satellite event at MICCAI 2026. To appear in Springer Lecture Notes in Computer Science (LNCS)

White blood cells (WBCs) present on every Giemsa-stained thick blood smear share visual properties with early-stage Plasmodium falciparum ring-form trophozoites: small size, round morphology, and intense purple staining. They are a plausible but untested source of false positives in parasite-only detectors. We trained two YOLOv12s models on the Lacuna Malaria Detection dataset (8,000 images from Uganda and Ghana): Model A with parasite labels only, and Model B with both parasite and WBC labels. Seven independent spatial and statistical analyses tested whether false positive (FP) predictions cluster near WBC locations. All seven refute the hypothesis. In both models, 95% of FPs are pure background detections (IoU below 0.10 against any ground-truth box); zero are WBC class confusions. Ripley's Cross-K analysis shows spatial repulsion between FP centroids and WBC positions at every radius tested. Model B outperforms Model A overall (mAP50 0.859 vs. 0.755), and the advantage is uniform across all WBC-proximity bands, pointing to multi-task representation learning rather than WBC suppression as the cause. False positives arise from Giemsa stain debris and preparation artifacts. Effective mitigation requires staining artifact augmentation and annotation of unannotated early-stage ring forms rather than WBC labeling alone.

0.44

Camera trap classification with deep learning under ground truth uncertainty

cs.CV ·2026-08-31 ·Leonard Hockerts, Peter S. Stewart, Sarthak Arora, Tiffany J. Vlaar
similarity 0.56
Abstract · 28 pages, 5 figures

Supervised deep learning methods enable the rapid processing of ecological image data, but depend on a costly annotation process. Consequently, training labels are commonly derived from volunteer citizen science projects. However, disagreement among volunteers introduces uncertainty in the "ground truth" data that are assumed to be correct for model training and validation. Using two datasets containing camera trap images with associated volunteer and expert classifications, we investigated the effects of training under higher ground truth uncertainty. We observed improved overall test accuracy, particularly for images that were more difficult for volunteers. Species-level accuracy also generally improved, but generalisation to a different dataset did not. The benefits of ground truth uncertainty were enhanced by pre-training on ImageNet. Pre-training also reduced the number of training epochs required; further reductions in computational cost, but not gains in accuracy, resulted from additional pre-training on other camera trap images. With unbalanced training data, we still observed a clear benefit of increased ground truth uncertainty for overall accuracy, especially on difficult images. Class imbalance improved accuracy for common species, reduced rare species accuracy, and changed patterns of misclassification to more closely resemble mistakes made by volunteers. Our findings have implications for applying deep learning across ecological image types with multiple labels. Practitioners can improve accuracy, especially on difficult examples, by including moderate levels of label disagreement during training and using models pre-trained on general image data. In addition to improving the use of citizen science-derived labels in model training, our study suggests avenues for more effectively integrating human and deep learning classifications in combined workflows. (abridged)

0.22

Towards Democratising Low-Data Medical Image Classification: CPU-Trainable ZACH-ViT and Its Geometric Variants

cs.CV cs.LG ·2026-11-12 ·Athanasios Angelakis
similarity 0.56
Abstract · 17 pages, 4 figures

Medical image classification in resource-constrained settings must contend with limited annotations and computational capacity. We evaluate four ZACH-ViT variants with linear, Euclidean prototype, Poincare and spherical heads alongside two compact multiple-instance-learning baselines. All models are trained from scratch with fewer than 260,000 parameters across seven MedMNIST+ datasets and three external benchmarks (PCam, ISIC2017 and Shenzhen tuberculosis radiographs). The low-data protocol uses 50 training images per class and five seeds, with validation-selected checkpoints at 23 and 47 epochs; a full-data reference uses one seed. Compact-TransMIL achieves the highest ten-dataset mean test Macro-F1 at 23 epochs (53.34%) and with full data (73.93%). At 47 epochs, ZACH-Linear narrowly leads (57.76% versus 57.54% for Compact-TransMIL). Extending training improves Macro-F1 in 239 of 300 paired comparisons. On ISIC2017, hZACH-Spherical has the highest 47-epoch low-data Macro-F1 (44.09% with SD 4.09%), whereas ZACH-EuclideanProto leads with full data (51.27%). We additionally conduct 40 CPU-only training runs on ISIC2017 and Shenzhen using four CPU threads; model-only single-image inference requires approximately 4-9 ms, while image decoding and preprocessing substantially increase end-to-end latency. The results demonstrate the feasibility of CPU-only training on the tested platform and the task- and regime-dependence of compact medical imaging under strict resource constraints.

0.18

SCOUT: Risk-Guided Foundation-Model Escalation for Robust Tissue Detection in Whole-Slide Images

cs.CV ·2026-11-18 ·Cristian Tommasino, Antonio M. Rinaldi
benchmarkcode/data similarity 0.56
Abstract

Reliable tissue detection is essential for whole-slide image analysis, yet high average segmentation accuracy can conceal failures involving pale tissue, small fragments, and heterogeneous staining. Pathology foundation models offer transferable representations, but exhaustive inference is computationally demanding and may introduce false-positive tissue predictions. We propose SCOUT (Selective Correction of Uncertain Tissue), a risk-guided cascade that selectively refines an initial thumbnail-based tissue mask. A lightweight audit network estimates the spatial distribution of segmentation errors and prioritizes candidate regions for processing by a frozen pathology foundation model. An asymmetric consensus rule integrates the resulting predictions with the initial mask to recover missed tissue while limiting false positives. A calibrated slide-level review score additionally controls the marginal rate of unflagged case-group failures under the calibration assumptions. Evaluation on a public multi-source, multi-stain benchmark shows that SCOUT reduces the proportion of case groups requiring mask correction from 38.1% for the best released detector to 18.6%, with particularly pronounced improvements in immunohistochemistry. Source-held-out experiments demonstrate better generalization than a segmentation network trained on the same annotations, while selective inference achieves an observed failure rate no higher than processing all candidate regions. Downstream, lymph-node classification with SCOUT masks is non-inferior to that obtained with two of the three released detectors evaluated. A variant built on an openly licensed foundation model is publicly released as an installable Python package with trained weights. These results support risk-guided foundation-model inference as an effective approach to tissue detection across heterogeneous histopathology data.

0.28