CS Paper Radar

CLC-YOLO: A Compact Channel-Gated Prototype Network for Real-Time Leakage-Aware Breast Ultrasound Lesion Segmentation

M. Fazri Nizar, Muhammad Naufal Rachmatullah, Julian Supardi

cs.CV ·submitted 2026-09-19 12:22 UTC · v2
publishedcode/data

Abstract

Reliable breast ultrasound lesion segmentation requires accurate boundaries and evaluation that prevents patients or duplicate images from crossing data splits. We propose Channel Local Contrast (CLC), a compact refinement of the YOLO26 segmentation prototype head. CLC adds a fixed local high-pass residual controlled by 64 zero-initialized, bounded channel gates. Baseline and CLC were compared in five matched folds on each of four breast ultrasound datasets. BUS-BRA used patient-disjoint outer tests with separate inner validation. BUS-UCLM and BrEaST used patient-grouped validation folds; BUSI used duplicate-component groups because patient identifiers are unavailable. Group-macro Dice increased by 1.68, 3.11, 1.12, and 2.45 percentage points on BUS-BRA, BUS-UCLM, BUSI, and BrEaST, respectively. Only the BUS-BRA paired 95% confidence interval excluded zero. CLC adds 64 parameters and 0.0049 giga floating-point operations (GFLOPs). At 640 pixels, single-T4, batch-one, 16-bit floating-point (FP16) TensorRT graph times were 2.1478 ms for CLC and 2.0512 ms for baseline, excluding preprocessing and postprocessing. CLC increased group-macro Dice across all four datasets with a measured T4 forward-pass overhead of 0.0966 ms. Code: https://github.com/mfazrinizar/CLC-YOLO

Comment
Accepted to IEEE ICAITech 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Can Multimodal Decision Models Classify Breast Ultrasound Images? Benchmarking CLEF and CLEF-Flash Across Prompts and Datasets

eess.IV cs.CV ·2026-10-09 ·Tran Cao Minh, Hai Tran, Ha Minh Tan
similarity 0.63
Abstract

Multimodal decision models return probabilities over predefined alternatives, offering a structured interface for image classification. This study benchmarks inference with CLEF and CLEF-Flash on 2818 breast ultrasound images from Dataset B, BUSI, and BUS-BRA. Dataset B and BUS-BRA use binary benign-malignant classification, whereas BUSI includes normal, benign, and malignant categories. Model parameters remain unchanged, and original images are submitted without user-defined preprocessing. Three prompts provide minimal labels, an explicit classification task, or sonographic criteria. We report accuracy, macro F1, balanced accuracy, macro precision, throughput, and latency. CLEF-Flash with the clinical prompt achieves the highest accuracy on all three datasets: 74.85% on Dataset B, 66.28% on BUSI, and 51.63% on BUS-BRA. On BUSI, however, CLEF with the task-guided prompt achieves the highest macro F1 (64.51%) and balanced accuracy (68.72%). CLEF-Flash has lower latency in every matched comparison. Clinical instructions improve CLEF-Flash accuracy relative to the minimal prompt but reduce CLEF accuracy on all datasets. Confusion matrices reveal frequent benign-to-malignant errors, particularly on BUS-BRA, where all configurations fall below the 67.63% accuracy of a majority-class predictor. These findings demonstrate dataset-and prompt-dependent performance and motivate class-specific evaluation before applying multimodal decision models to breast ultrasound analysis.

0.51

Region-aware error triage for medical image segmentation with groupwise conformal risk control

cs.CV ·2026-11-06 ·Nishi Kanta Paul, Md Shihabul Islam Shovo, Hoileong Lee
similarity 0.62
Abstract · 22 pages, 7 figures, 12 tables. Submitted to Biomedical Signal Processing and Control (BSPC)

Segmentation masks are increasingly reviewed rather than redrawn, which requires knowing where a mask is likely wrong. Learned error maps rank pixels by risk, but the number of pixels to warn is chosen ad hoc, and calibrating one warning threshold over all error pixels may leave errors far from the predicted contour under-flagged. We propose RACE-Triage, a post-hoc error triage framework that leaves the segmentation mask unchanged. A risk network is trained on out-of-fold predictions from backbone-independent inputs. The predicted contour partitions each image into a boundary band and a non-boundary region, and conformal risk control is applied separately in each region to bound the expected fraction of missed errors among cases with errors there. On ISIC 2018 dermoscopy and BUSI breast ultrasound (where patient identifiers are unavailable, so independence across images is assumed), pooled control met its overall target but missed on average 31.8% and 36.4% of non-boundary errors. Regional control reduced these fractions to 19.3% and 20.9% and raised the recall of size-filtered false-negative components from 0.722 to 0.818 and from 0.611 to 0.763. The mean warned area grew by 1.6 and 4.9 percentage points, and its 95th percentile reached 23.5% and 38.5%. The effect held across three seeds and a second backbone, and area-matched heuristics did not reproduce it. On the external PH$^2$ set, frozen thresholds exceeded both targets, whereas recalibration with 100 local images brought the mean over repeated splits below them. Regional calibration improves non-boundary error coverage at a measured increase in warned area.

0.30

Thyroid Nodule Segmentation in Ultrasound Images with Conformal Uncertainty Estimation

cs.CV stat.AP ·2026-10-09 ·Francesco Teodori, Pierpaolo Brutti, Umberto Ferraro Petrillo
publishedbenchmark similarity 0.61
Abstract · Presented at the CIBB 2026 conference

Thyroid nodules affect a large proportion of the general population. Although most are benign, a non-negligible fraction is malignant. Ultrasound imaging is the primary diagnostic modality, and accurate nodule segmentation is a prerequisite for CAD systems to classify malignancy and assess metastatic risk.\\ In this work, we propose a thyroid nodule segmentation framework that integrates a DeepLabV3+, channel-attention modules and post-hoc conformal prediction, providing both accurate mask and pixel-level uncertainty estimates. We address thyroid ultrasound nodule segmentation as the first stage of a pipeline that also includes malignancy classification and metastatic risk prediction. We adopt DeepLabV3+, whose Atrous Spatial Pyramid Pooling (ASPP) captures multi-scale context, with an EfficientNet-B5 backbone for its accuracy-efficiency trade-off. Additionally, we test three channel-attention modules: Squeeze-and-Excitation, CBAM and Grouped Channel Attention (GCA), paired with two loss formulations (Dice-BCE and Boundary).\\ Since binary masks do not indicate prediction confidence, we wrap the trained model with a split conformal prediction layer that produces pixel-level uncertainty maps with statistical coverage guarantees.\\ We evaluate all configurations on the TN3K public benchmark using a fixed split and directly compare them with state-of-the-art methods. The plain backbone already improves upon previously reported results, with CBAM + Dice-BCE emerging as the best overall configuration.

0.17

Beyond Accuracy: Uncertainty-Guided Boundary Refinement for Reliable Biomedical Image Segmentation

cs.CV cs.LG ·2026-09-11 ·Anima Kujur
similarity 0.60
Abstract

Accurate biomedical image segmentation requires not only high global overlap but also reliable delineation of clinically meaningful boundaries. In blood-smear microscopy, cytoplasm and nucleus contours provide the structural basis for downstream morphology analysis; however, deep segmentation models may remain uncertain or overconfident near ambiguous boundary regions even when achieving strong Dice scores. This work proposes a Reliability-Aware Boundary Refinement Network (RABR-Net), a two-stage framework for trustworthy image segmentation. A strong UNet++ EfficientNet-B4 base segmenter first produces initial class probabilities and logits. Predictive entropy, test-time augmentation variance, margin uncertainty, probability gradients, and soft boundary cues are then combined into a boundary-aware reliability representation. This representation guides a gated residual refiner that selectively corrects uncertain boundary pixels while preserving confident regions of the base prediction. The framework is evaluated using overlap accuracy, class-wise Dice, Boundary Dice, HD95/ASSD, calibration, risk--coverage analysis, robustness under image perturbations, qualitative correction maps, and paired statistical testing. On the held-out test set, the proposed method improves Dice from 0.9602 to 0.9614, Boundary Dice from 0.3448 to 0.3611, and HD95 from 3.0354 to 2.8274 compared with the cached base prediction. Statistical analysis confirms significant improvements in Dice, Boundary Dice, and HD95. Qualitative results show that the learned gate concentrates around uncertain cytoplasm and nucleus boundaries, and correction maps confirm localized boundary refinement. Although calibration does not automatically improve after refinement, the proposed framework provides an interpretable and reliability-focused strategy for boundary-sensitive biomedical image segmentation.

0.22

DualMiT-Net: Local-Global Transformer-Convolutional Fusion for Breast Mass Segmentation in Mammographic Regions of Interest

cs.CV cs.AIcs.LG ·2026-08-15 ·Alibek Kamiluly, Milana Muratova, Yash Patel, Fan Li
similarity 0.60
Abstract

Breast mass segmentation is an important step in computer-aided mammography, but it remains difficult because masses can have low contrast, irregular shapes, and boundaries that blend with surrounding breast tissue. To address this problem, we present DualMiT-Net, a dual-branch network that uses both a focused view of the mass and a wider view of the surrounding tissue. The local branch uses a Mix Transformer (MiT-B5) encoder to learn mass shape, texture, and boundary information, while the global branch uses an EfficientNet-B5 encoder to learn surrounding breast context. Features from the two branches are shared at the deeper encoder levels and are then progressively fused in a single decoder. A spatial gate controls how much global information is added during decoding. We also evaluated four input representations and selected a percentile-windowed mammogram combined with a Gabor texture response. The model was trained and evaluated on the mass subset of the Curated Breast Imaging Subset of the Digital Database for Screening Mammography (CBIS-DDSM) using a patient-level split. Across three training runs, DualMiT-Net with exponential moving average weights achieved a mean Dice coefficient of 0.9375 and a mean Intersection over Union of 0.8834. It also achieved better Dice and IoU scores than six standard encoder-decoder baselines trained using the same data and training settings. These results show that combining local mass information with wider breast context can provide accurate and consistent breast mass segmentation.

0.04

MoWE: Spatially Adaptive Mixture-of-Wavelet-Experts Pooling for Ultrasound Lesion Segmentation

cs.CV ·2026-10-18 ·Reaz Hassan Joarder, Sidratul Tanzila Tasmi, Alif Arshad Bakshi, Md. Bakhtiar Hasan, Md Hasanul Kabir
published similarity 0.60
Abstract · Accepted to WACV 2027

We present Mixture-of-Wavelet-Experts (MoWE), a spatially adaptive routing mechanism that replaces max-pooling and strided convolutions in U-Net architectures for ultrasound lesion segmentation. Standard pooling operations suppress high-frequency spatial details, including potential boundary cues in speckled regions. Recent frequency-domain methods preserve some of these details, but a single wavelet family applies the same spectral bias across the image. MoWE instead uses a context-aware router to assign local regions to fixed wavelet families according to local texture and global feature context. The decoder reuses the encoder's spatial routing maps during the inverse transform. Learnable channel-wise gates rescale the high-frequency subbands before reconstruction. We evaluate MoWE with U-Net on four ultrasound lesion benchmarks (BUSI, TN3K, UDIAT, BUS-UCLM) and one cardiac dataset (CAMUS), and with nnU-Net on BUSI. On BUSI, MoWE improves U-Net Dice from 72.59\% to 74.55\% and reduces HD95 from 47.01 to 43.49\,px. With nnU-Net, MoWE improves Dice from 80.18\% to 81.97\% and reduces ASSD from 20.07 to 17.25\,px. On U-Net, MoWE reduces trainable parameters by 6.4\%.

0.26

When Adaptation Hurts: Connecting Representational Drift to OOD Failures in MedSAM Fine-Tuning

cs.CV ·2026-08-21 ·Marko Haralović, Sounic Akkaraju, Carlo Baretta, Vasil Zapryanov, Alexia Briassouli
publishedcode/data similarity 0.60
Abstract · Accepted at the SAFER Workshop, MICCAI 2026, non camera-ready version

Foundation models for medical image segmentation, like prompt-based MedSAM, generalize well across domains and modalities, often in zero or few-shot setups. However, their performance depends on the quality of prompts and the adaptation of the models to custom datasets. This work systematically examines how MedSAM generalizes across diverse medical imaging benchmarks, with six adaptation strategies: full-model and encoder-only LoRA, shallow and deep visual prompt tuning (VPT), and decoder-only and full fine-tuning. Models are trained on the International Skin Imaging Collaboration Challenge (ISIC 2018) dataset and evaluated under clean and increasingly noisy prompts on IN and Out-of-Distribution (OOD) datasets: close-OOD PH2 (dermoscopy), far-OOD BUSI (Breast Ultrasound Images Dataset) and CBIS-DDSM (Curated Breast Imaging Subset of the Digital Database for Screening Mammography). We show that adaptation improves performance on IN and close-OOD data but often reduces performance on far-OOD data. Full fine-tuning provides the best tradeoff, while encoder-only LoRA is the strongest parameter-efficient alternative, outperforming standard LoRA and VPT under far-OOD shifts. Using Centered Kernel Alignment (CKA), we show that far-OOD degradation is strongly associated with drift in decoder representations, whereas encoder similarity alone does not explain robustness. This suggests encoder-only LoRA provides stronger robustness than standard LoRA by adapting the encoder to distribution shift in visual features, while preserving the decoder pathway. We further show that random 0-100 pixel jitter on prompts produces more robust and better performing models. We thus conclude that robust MedSAM adaptation requires the combined consideration of prompt noise exposure, domain shift, and representation preservation. We release our code: https://github.com/ImSounic/medsam-vpt

0.68

M3D-Net: Hierarchical Coordination of Spatial Context, Feature Reuse, and Differential Attention for Mammography Classification

cs.CV cs.LG ·2026-09-23 ·Zheng Yu, Xinhang Li, Jiabao Gao, Boyang Wang, Xiang Li
similarity 0.59
Abstract · Submitted to IEEE ICASSP 2027; 5 pages, 4 figures

Breast image classification requires local detail and global tissue context, yet these cues can weaken as representations deepen. We present M3D-Net, a mammography encoder that hierarchically coordinates multi-scale coordinate attention, bounded dynamic feature reuse, and differential attention through resolution-aware operator placement. Within-stage retrieval preserves access to earlier features, coordinate-aware aggregation integrates local and global context, and differential attention operates at coarse resolutions. We evaluate image-only classification on AISSLab mammography and an adapted image--clinical model on BrEaST ultrasound. Against EdgeNeXt, RepViT, and TransXNet, the proposed implementations achieve the highest recorded validation accuracy and late-training accuracy, with the lowest endpoint cross-entropy loss. Validation accuracies reach 97.78\% and 80.39\%, respectively. These results support further evaluation of hierarchical coordination across breast imaging settings; repeated-seed, component-controlled, and independent evaluations remain necessary.

0.23