CS Paper Radar

Measurement-Gated Provenance Attenuation for Frozen EEG Representations

Anuar Aimoldin, Yankai Chen, Ayana Mussabayeva, Nurdaulet Akhanov, Xue Liu

cs.LG ·submitted 2026-09-26 19:23 UTC · v1
code/data

Abstract

Frozen EEG representations retain acquisition signatures as well as neural activity. Source predictability alone does not identify what should be removed: it can reflect measurement effects or genuine biological and population differences, which should not be erased. We propose Measurement-Gated Provenance Attenuation (MGPA), built on one principle: measurement evidence determines where correction may act, and preserved information determines what it should aim for. Paired measurement contrasts define a gate outside which nothing changes; inside it, the source score is moved to the value the preserved coordinates already predict: for a fixed affine score, this keeps the same information as any target set by those coordinates and needs the least expected squared movement. Closed-form and critic-guided iterative constructions apply it without source identity or encoder retraining. Three studies test the principle at increasing distance from its assumptions. Under controlled reference changes, where the source-task association is known, MGPA brings source to near chance with task performance unchanged, whereas erasing what predicts source (LEACE) lowers frozen-task AUROC from .753 to .656 while barely touching source; ablations attribute the attenuation to the gate's directions and 2.7x less movement to the conditional target. Across recordings from different devices and electrodes, iterative correction lowers source accessibility while preserving or improving task performance. Finally, one iterative map selected on one task and reused unchanged on existing heads for two others raises their worst-association AUROC (lowest over device-label shifts) by .057 and .019 over LEACE, at a cost to those heads while the training association holds. A reusable correction shows its value in how an existing predictor behaves once acquisition cues stop being reliable, not only in what a probe can read.

Comment
23 pages, 4 figures, 11 tables. Code: https://github.com/sneddy/mgpa-paper

Closest papers

Nearest neighbours by meaning across the whole index.

PhysioTRACE: Provenance-Aware Stress Tests for Physiological Foundation Models

cs.LG ·2026-09-28 ·Ayana Mussabayeva, Anuar Aimoldin, Olivier Oullier, Xue Liu, Kun Zhang
similarity 0.70
Abstract · Main text: 10 pages, 4 figures. Appendix: 31 pages with full protocol details, per-seed results, and sensitivity analysis

Physiological foundation models encode how a signal was recorded alongside the physiology it reflects. When recording conditions are associated with diagnosis, this acquisition provenance can become a shortcut, yet the usual evidence, shifted transfer and provenance decodability, does not show whether a predictor uses it. We introduce PhysioTRACE, a four-axis behavioral audit for frozen encoders that separates what a probe can decode from what a fixed task head relies on. Recover scores how decodable provenance is; Stress reverses only the provenance-target association on the same held-out records; Intervene removes a train-localized provenance component; and Verify certifies that removal only if it beats matched random projections within a declared utility margin. Each audit thus ends in one of three verdicts: no reliance, or reliance with the remedy certified or refused. Across EEG and ECG, five training objectives, and five frozen foundation models, the relation between Recover's calibrated score and out-of-distribution utility changes sign between datasets, so neither can stand in for a reliance test. On paired EEG views where the shortcut is known by construction, the audit detects it (the exposed head loses about 0.2 AUROC when the association is reversed, while a control head is unaffected) and certifies removal of a rank-two component that restores control-level behavior without measurable utility loss, for both encoder objectives tested. On real ECG device metadata it returns all three verdicts: it certifies a remedy that removes 91% of one model's excess vulnerability, finds no reliance where device and diagnosis are barely associated, and refuses the remedy for a second model whose localized direction also carries task signal. Robustness to how inputs were recorded therefore needs a behavioral test, and PhysioTRACE provides one that can pass, fail, or refuse a remedy.

0.24

Identifying Neural Source Dynamics from Unknown Local Interventions

cs.LG ·2026-09-28 ·Ayana Mussabayeva, Jiaqi Sun, Anuar Aimoldin, Olivier Oullier, Kun Zhang
similarity 0.64
Abstract · 11 pages main text, 52 pages total including references and appendices; 3 figures

Electroencephalography (EEG) records mixtures of brain-source activity. Even with a known anatomical forward model, experiments that excite only part of the source-state space leave the dynamics unidentified, and repetition cannot resolve the ambiguity. We show that unknown local mechanism changes can supply the missing information. We consider linear dynamics among fixed anatomical sources with known source-state initialization patterns. Changing one source's update rule for one transition leaves a rank-one, source-specific signature in subsequent EEG: subtracting matched baseline responses isolates it, and the forward model identifies the source and calibrates its response history. Combining these histories with initialization responses recovers source interactions without baseline reachability and without first identifying the intervention coefficients. We establish sufficient recovery conditions, a direct estimator, and a noise-sensitivity bound conditional on correct source labels. Simulated EEG on anatomy derived from magnetic resonance imaging confirms the information gain: with baseline excitation confined to four of twelve source coordinates, eight unknown changes recover all dynamics in 32/32 systems, whereas baseline realization, baseline regression through an invertible forward model, and changes that leave the tested states unexposed all fail, and explicitly constructed alternative dynamics reproduce every baseline mean. Where baseline information suffices, direct reconstruction is also more reliable than a matched-information spectral estimator. Nonlocal changes and forward-model error limit accuracy even when source labels are correct.

0.34

Taming foundation model with invariance-oriented pre-training for broad-spectrum EEG analysis across signal-level, brain-state, and brain-health tasks

cs.LG cs.AI ·2026-08-25 ·Yulong Dou, Han Wu, Guo Chen, Fangmao Ju, Zhiming Cui +1 more
benchmark similarity 0.63
Abstract

Electroencephalography (EEG) is a widely used window into human brain function, but most EEG models remain tied to a one-dataset-one-model supervised paradigm. Recent EEG foundation models offer a route toward reusable representations, but most remain reconstruction-centered, assuming that EEG content predictable from local context is necessarily transferable neural information. Here we present INCEPT, an invariance-oriented EEG foundation model trained on over 11,000 hours of unlabelled clinical EEG. Rather than prioritizing signal recovery alone, INCEPT learns representation-level stability across correlated EEG observations, separating stable neural structure and essential subject-sensitive information from the nuisance variability that dominates scalp recordings while preserving subject-, state- and condition-discriminative information. We evaluate INCEPT on a broad-spectrum benchmark of ten datasets spanning three levels of post-acquisition EEG analysis: signal-level assessment, brain-state decoding, and brain-health evaluation. INCEPT ranks first among recent EEG foundation models on 26 of 30 linear-probing metrics and 24 of 30 fine-tuning metrics, and also surpasses strong task-specific specialist encoders across diverse downstream settings. Objective ablations and representation analyses further show that invariance-oriented pre-training improves transfer and organizes subject-sensitive neural representations beyond reconstruction alone. These results establish invariance learning as a promising principle for building reusable EEG foundation models.

0.11

Controlled Evaluation of EEG Foundation Models: Random Initialisation, Band-Power and Validation-Selected Probes

cs.LG cs.AI ·2026-10-23 ·Mingyu Jeon, Suwan Cho, Jae Young Suh
similarity 0.63
Abstract

EEG foundation models report downstream gains, yet their protocols seldom include three controls. These are the same encoder untrained, spectral features fitted on the same data, and a layer picked without looking at test scores. We therefore evaluate five publicly released EEG foundation models and an in-house JEPA-style model under one protocol with all three controls and several seeds, on five benchmarks and four added task families. The controls change the reading in three ways. First, picking the probed layer by its test score raises the layer-wise peak by an average of +0.034 and reverses the peak-versus-output gap in 9 of 36 cells. Second, with the layer picked on validation, random initialisation matches or beats pretraining for half of the models on sleep and emotion, and no model beats a five-band log-power baseline on emotion or motor imagery. Third, after full fine-tuning only 5 of 30 pairs gain beyond twice their seed spread, and the one clear loss of -0.290 AUROC persists under matched learning rates. From these results we draw four reporting practices, and we release every cell for re-analysis.

0.06

Reference Coordinates, Output Perturbations, and Information Loss in EEG Decoding

eess.SP ·2026-11-17 ·Runni Zhou, Rongrong Fu, Xinghao Yan, Xiaoyang Li
similarity 0.63
Abstract · 45 pages including supplementary material; 5 figures in the main text. Data and code included as ancillary material

Electroencephalography (EEG) decoders can respond to reference changes that preserve all relative-potential information. We use established measurement-operator theory to distinguish coordinate sensitivity, additional output-channel perturbations, and electrode loss. Exact pseudoinverse alignment supplies a consistency control; measurement-operator canonicalization (MOC) denotes a graph-Tikhonov estimator. The broader evaluation covers three public motor-imagery datasets and four decoders. The primary EEGNet comparison on Cho2017 and PhysioNet uses three paired training seeds, three shared noise realizations, and six front ends, with identical CAR training inputs sharing checkpoints. At 10 dB output perturbation, MOC-minus-raw disagreement was -0.144 and -0.107, while balanced-accuracy differences were 0.044 and 0.050, respectively; these four contrasts passed the retained Holm correction. MOC also reduced disagreement relative to pseudoinversion across all three seeds in both cohorts. However, comparison with fixed graph smoothing after pseudoinversion did not establish an additional MOC benefit. Preserving zero reference rows changed raw disagreement by less than 0.001 in magnitude; inverse-method predictions were unchanged. For canonical front ends, cross-reference disagreement was close to the reference obtained from independent noise within the same operator. Controlled weak-mode reconstruction and equal-rank electrode masks exposed separate stability and information-loss effects. The results locate the complete-reference gains within spatial processing under the specified stress model, while requiring decoding accuracy alongside consistency to assess practical utility.

0.36

SpecBraM: What Should an EEG Foundation Model Predict? Masked Band-Power Prediction versus Waveform Reconstruction

cs.LG ·2026-10-05 ·Peng Xie, Yequan Bie, Jianda Mao, Kani Chen
similarity 0.63
Abstract · 12 pages, 3 figures, 9 tables; includes an appendix

Self-supervised EEG models often reconstruct masked waveforms or predict discrete codes. We study a task-aligned alternative: masked band-power prediction (MBP), which predicts fixed narrow-band log spectral energy for masked channel-time patches. This target retains rhythm power relevant to sleep staging while avoiding phase-sensitive waveform reconstruction and a learned codebook. Across three pretraining seeds, we compare band-power and waveform targets with matched backbones, pretraining data (2,388 hours), and training steps, including a 2x2 tokenizer-by-target design. On ISRUC and HMC sleep staging, MBP exceeds raw- and band-waveform reconstruction by 1.6-2.8 balanced-accuracy points with all labels and 4.7-7.3 points with 1% of labels under a strict linear probe; the target effect exceeds the tokenizer effect. Its frozen features reach 0.7916/0.7425 balanced accuracy, versus 0.7636/0.7227 for a matched rich handcrafted spectral baseline, although the gap is about one point with 1% of labels. Full fine-tuning reaches 0.8107/0.7669. The gains do not extend to every task with spectral cues, including motor imagery, depression screening, and vigilance regression. These results support choosing pretraining targets to match the physical quantities and spatial and temporal scales relevant to downstream labels.

0.14

Matched-Input Estimates Differ in Sign Across Architectures: Auditing EEG Foundation Models on Motor Imagery

cs.LG q-bio.NC ·2026-09-20 ·Kevin Zhou, Sparsh Roy
similarity 0.62
Abstract

Pretrained EEG foundation models are increasingly proposed as general-purpose encoders for brain-computer interfaces, yet recent benchmarks disagree about when their representations transfer to downstream tasks. We audit LaBraM and CBraMod on motor imagery under a validation-locked protocol in which preprocessing, architecture, optimization, freeze depth, checkpoint, temperature, and method selection are determined using training-session data only. On four-class BCI Competition IV-2a, every supervised comparator evaluated here outperforms every foundation-model configuration, including validation-selected fine-tuning. We then examine a key confound: foundation models and task-specific decoders are normally evaluated using different input pipelines. Retraining three supervised architectures on the broadband arrays consumed by the foundation models produces matched-input accuracy differences of opposite sign across architectures: broadband input improves ATCNet by 0.078 accuracy while reducing EEG Conformer accuracy by 0.088. None of the three individual matched-input terms is significant after multiple-comparison correction at n = 9, so we treat the sign variation descriptively rather than as a formal architecture-by-pipeline interaction. These observed sign differences suggest that a single comparator may not provide an architecture-invariant decomposition of a pretrained-versus-supervised performance gap. The four-class deficit also does not reproduce uniformly across motor-imagery datasets: on two-class BNCI2014-004 we cannot detect the same separation between fine-tuned CBraMod and the supervised comparators. Finally, validation-fitted temperature scaling returns foundation-model calibration error to the supervised range despite substantially lower four-class accuracy.

0.32

Benchmarking Label-Revealed Online Updates for EEG BCI Decoding

cs.LG eess.SP ·2026-10-05 ·Bogdan Kozyrskiy, Artem Grachev, Abraham I. Camelo Guerrero
benchmark similarity 0.62
Abstract

Electroencephalography (EEG) signals drift over time, which can cause static brain-computer interface (BCI) models to degrade in practice. We present a benchmark for online adaptation and compare two widely used pipeline families, Common Spatial Patterns (CSP) and Riemannian covariance-based methods, under time-ordered prequential (test-then-train) evaluation. We examine (i) which pipelines benefit most from label-revealed updates, (ii) whether controlled forgetting of older data improves robustness, and (iii) how a minimal-calibration cold start compares with starting from a pretrained model. Across four datasets (three motor-imagery datasets and one movement-decoding dataset), label-revealed online updates improve 13 of 14 model/dataset pairs on the two largest streams, with relative accuracy gains of up to about 18% over a frozen model. A Shapley-based data-valuation analysis over temporal blocks assigns the largest mean value to the most recent block in each of the three analyzed datasets, while older blocks retain positive value.

0.42