CS Paper Radar

SpecBraM: What Should an EEG Foundation Model Predict? Masked Band-Power Prediction versus Waveform Reconstruction

Peng Xie, Yequan Bie, Jianda Mao, Kani Chen

cs.LG ·submitted 2026-10-05 22:49 UTC · v1

Abstract

Self-supervised EEG models often reconstruct masked waveforms or predict discrete codes. We study a task-aligned alternative: masked band-power prediction (MBP), which predicts fixed narrow-band log spectral energy for masked channel-time patches. This target retains rhythm power relevant to sleep staging while avoiding phase-sensitive waveform reconstruction and a learned codebook. Across three pretraining seeds, we compare band-power and waveform targets with matched backbones, pretraining data (2,388 hours), and training steps, including a 2x2 tokenizer-by-target design. On ISRUC and HMC sleep staging, MBP exceeds raw- and band-waveform reconstruction by 1.6-2.8 balanced-accuracy points with all labels and 4.7-7.3 points with 1% of labels under a strict linear probe; the target effect exceeds the tokenizer effect. Its frozen features reach 0.7916/0.7425 balanced accuracy, versus 0.7636/0.7227 for a matched rich handcrafted spectral baseline, although the gap is about one point with 1% of labels. Full fine-tuning reaches 0.8107/0.7669. The gains do not extend to every task with spectral cues, including motor imagery, depression screening, and vigilance regression. These results support choosing pretraining targets to match the physical quantities and spatial and temporal scales relevant to downstream labels.

Comment
12 pages, 3 figures, 9 tables; includes an appendix

Closest papers

Nearest neighbours by meaning across the whole index.

Controlled Evaluation of EEG Foundation Models: Random Initialisation, Band-Power and Validation-Selected Probes

cs.LG cs.AI ·2026-10-23 ·Mingyu Jeon, Suwan Cho, Jae Young Suh
similarity 0.72
Abstract

EEG foundation models report downstream gains, yet their protocols seldom include three controls. These are the same encoder untrained, spectral features fitted on the same data, and a layer picked without looking at test scores. We therefore evaluate five publicly released EEG foundation models and an in-house JEPA-style model under one protocol with all three controls and several seeds, on five benchmarks and four added task families. The controls change the reading in three ways. First, picking the probed layer by its test score raises the layer-wise peak by an average of +0.034 and reverses the peak-versus-output gap in 9 of 36 cells. Second, with the layer picked on validation, random initialisation matches or beats pretraining for half of the models on sleep and emotion, and no model beats a five-band log-power baseline on emotion or motor imagery. Third, after full fine-tuning only 5 of 30 pairs gain beyond twice their seed spread, and the one clear loss of -0.290 AUROC persists under matched learning rates. From these results we draw four reporting practices, and we release every cell for re-analysis.

0.06

MANAS-2: Constrained Reconstruction for EEG Foundation Models

cs.AI cs.LG ·2026-09-12 ·Arvasu Kulkarni, Aditya Ray Mishra, Jeet Bandhu Lahiri, Mahir Jain, Parshva Runwal +3 more
similarity 0.71
Abstract · 17 pages, 3 figures, 15 tables

Masked reconstruction is widely used for EEG foundation models, but optimizing reconstruction on low-SNR waveforms does not necessarily produce the most useful latent representation. We introduce MANAS-2, a new EEG foundation model that combines a Raw-Band Hybrid (RBH) masked autoencoder with Constrained Reconstruction (ConRec), a physics-motivated regularizer. RBH jointly reconstructs temporal waveform patches and compact spectral-band targets, while ConRec acts only on the temporal decoder output, penalizing differences in RMS energy between adjacent short windows of the reconstructed waveform. ConRec is intended to shape the encoder by biasing it toward the organization of oscillatory-envelope information. Across seven held-out EEG datasets, adding ConRec to an otherwise identical RBH model increases frozen ridge recovery of six-band spectral power from mean R^2=0.860 to 0.906 and recovery of inter-patch band-energy dynamics from R^2=0.283 to 0.354, while temporal waveform information remains highly recoverable from the frozen latents. Applied to a temporal-only masked autoencoder, ConRec also improves frozen downstream transfer and frequency-dependent latent geometry despite receiving no spectral targets: i.e., the effects of ConRec are architecture-independent. MANAS-2 also outperforms leading EEG Foundation Models on most downstream knowledge-transfer tasks. From the effects of ConRec, we see that a physically motivated constraint imposed through the decoder can make for a more spectrally organized and transferable latent space. MANAS-2 therefore provides a new EEG foundation model built around constrained reconstruction as a mechanism for shaping representation--rather than reconstruction--quality.

0.39

BrainCodes: A Lightweight EEG Foundation Model over Discrete Neural Codes

cs.LG cs.NE ·2026-10-21 ·Kleanthis Avramidis, Ivan Tashev, Dimitra Emmanouilidou
position similarity 0.66
Abstract · Preprint. Under review

Recent electroencephalography (EEG) foundation models increasingly emphasize model scale, potentially limiting their deployment on resource-constrained devices and in everyday environments. We argue that transferable EEG features can instead be learned with a compact architecture and introduce BrainCodes, a lightweight foundation model pretrained through self-supervised learning on more than 800 hours of recordings from over 1,000 participants. Our architecture combines a quantization-based neural tokenizer with a spatiotemporal encoder that supports arbitrary electrode configurations. The pretraining objective explicitly encourages representations that capture spatial connectivity through channel positional encoding, and sensitivity to narrowband neural oscillations through an auxiliary training objective. Our model matches or surpasses the state of the art across diverse neurophysiological monitoring tasks, including sleep staging, attention assessment, and cognitive load estimation. BrainCodes transfers effectively to low-resource wearable devices while using up to 97% fewer trainable parameters than comparable architectures. Beyond predictive accuracy, our evaluation framework characterizes the geometry and invariances of learned EEG representations across measurable spatial, temporal, and spectral signal properties.

0.21

Benchmarking EEG Foundation Models at Scale: Lessons from 20,000 Evaluations

cs.LG eess.SP ·2026-09-26 ·Zhige Chen, Shu Peng, Chengxuan Qin, Rui Liu, Rui Yang +2 more
benchmarkcode/data similarity 0.65
Abstract · 91 pages, including appendices and supplementary material

Electroencephalography (EEG) foundation models (FMs) promise transferable neural representations, yet their advantages over strong supervised baselines and their prospects for further scaling remain unclear. To address these questions, we introduce EEG-Arena, an open-source benchmark covering 30 EEG FMs and 25 supervised baselines evaluated on 57 downstream tasks from 23 public datasets. Through more than 20,000 evaluations across five experimental protocols, we assess downstream performance, pretraining benefits, model size scaling, pretraining data scaling, and robustness to channel configuration. We find that (1) EEG FMs outperform strong task-specific supervised baselines on most evaluated tasks, particularly under non-bipolar settings; (2) compared with architecture-matched supervised training from scratch, pretraining improves both early optimization and final downstream performance, with larger and more consistent gains as more labeled downstream data become available; (3) existing EEG FMs do not exhibit a consistent positive relationship between parameter count and downstream performance; (4) under a fixed architecture, increasing the pretraining data scale yields sustained downstream gains; and (5) channel-flexible FMs achieve higher absolute performance than channel-constrained models across most evaluated channel configurations. Together, these findings demonstrate the downstream value of EEG FMs and identify pretraining data expansion as a promising direction for further progress. To support continued research, we release EEG-Arena as an open-source evaluation framework that provides shared infrastructure for reproducible benchmarking, model comparison, and community-driven development.

0.56

Matched-Input Estimates Differ in Sign Across Architectures: Auditing EEG Foundation Models on Motor Imagery

cs.LG q-bio.NC ·2026-09-20 ·Kevin Zhou, Sparsh Roy
similarity 0.64
Abstract

Pretrained EEG foundation models are increasingly proposed as general-purpose encoders for brain-computer interfaces, yet recent benchmarks disagree about when their representations transfer to downstream tasks. We audit LaBraM and CBraMod on motor imagery under a validation-locked protocol in which preprocessing, architecture, optimization, freeze depth, checkpoint, temperature, and method selection are determined using training-session data only. On four-class BCI Competition IV-2a, every supervised comparator evaluated here outperforms every foundation-model configuration, including validation-selected fine-tuning. We then examine a key confound: foundation models and task-specific decoders are normally evaluated using different input pipelines. Retraining three supervised architectures on the broadband arrays consumed by the foundation models produces matched-input accuracy differences of opposite sign across architectures: broadband input improves ATCNet by 0.078 accuracy while reducing EEG Conformer accuracy by 0.088. None of the three individual matched-input terms is significant after multiple-comparison correction at n = 9, so we treat the sign variation descriptively rather than as a formal architecture-by-pipeline interaction. These observed sign differences suggest that a single comparator may not provide an architecture-invariant decomposition of a pretrained-versus-supervised performance gap. The four-class deficit also does not reproduce uniformly across motor-imagery datasets: on two-class BNCI2014-004 we cannot detect the same separation between fine-tuned CBraMod and the supervised comparators. Finally, validation-fitted temperature scaling returns foundation-model calibration error to the supervised range despite substantially lower four-class accuracy.

0.32

Measurement-Gated Provenance Attenuation for Frozen EEG Representations

cs.LG ·2026-09-26 ·Anuar Aimoldin, Yankai Chen, Ayana Mussabayeva, Nurdaulet Akhanov, Xue Liu
code/data similarity 0.63
Abstract · 23 pages, 4 figures, 11 tables. Code: https://github.com/sneddy/mgpa-paper

Frozen EEG representations retain acquisition signatures as well as neural activity. Source predictability alone does not identify what should be removed: it can reflect measurement effects or genuine biological and population differences, which should not be erased. We propose Measurement-Gated Provenance Attenuation (MGPA), built on one principle: measurement evidence determines where correction may act, and preserved information determines what it should aim for. Paired measurement contrasts define a gate outside which nothing changes; inside it, the source score is moved to the value the preserved coordinates already predict: for a fixed affine score, this keeps the same information as any target set by those coordinates and needs the least expected squared movement. Closed-form and critic-guided iterative constructions apply it without source identity or encoder retraining. Three studies test the principle at increasing distance from its assumptions. Under controlled reference changes, where the source-task association is known, MGPA brings source to near chance with task performance unchanged, whereas erasing what predicts source (LEACE) lowers frozen-task AUROC from .753 to .656 while barely touching source; ablations attribute the attenuation to the gate's directions and 2.7x less movement to the conditional target. Across recordings from different devices and electrodes, iterative correction lowers source accessibility while preserving or improving task performance. Finally, one iterative map selected on one task and reused unchanged on existing heads for two others raises their worst-association AUROC (lowest over device-label shifts) by .057 and .019 over LEACE, at a cost to those heads while the training association holds. A reusable correction shows its value in how an existing predictor behaves once acquisition cues stop being reliable, not only in what a probe can read.

0.33

What masking geometry works best for EEG foundation models?

cs.LG ·2026-09-27 ·Pierre Guetschel, Bruno Aristimunha, Yassine El Ouahidi, Arnaud Delorme, Thomas Moreau +1 more
code/data similarity 0.62
Abstract · A controlled evaluation across MAE and JEPA. 44 pages, 12 figures, 15 tables. Project page: https://pierregtch.github.io/eeg-fm-masking

EEG foundation models hold promise for scalable brain-signal decoding across clinical and cognitive neuroscience applications, yet their pre-training pipelines remain poorly understood. Among design choices, the masking strategy is particularly critical: it determines what the network must predict and from which context. Yet it has never been ablated in isolation, as each new model bundles a new masking strategy with a new backbone and objective. In this paper, we formalize the design choices for spatio-temporal masking strategies and train various models with a single pipeline under varying masking configurations across two SSL frameworks (MAE and JEPA). We then systematically evaluate the resulting 58 pre-trained models on the 12 datasets of OpenEEGBench under a linear probe. Both frameworks agree on an optimal masking configuration and on shared failure modes. Outside these, performance is robust: 11 MAE and 9 JEPA configurations are statistically indistinguishable from the best. We further identify a novel JEPA-specific failure mode, tagged bias-inflation collapse, invisible to standard detectors. With a well-chosen mask, our pipeline reaches REVE-level downstream performance at a fraction of REVE's pre-training compute.

0.45

Probing Spatial and Spectral Grounding in EEG Foundation Models

cs.NE ·2026-10-21 ·Kleanthis Avramidis, Ivan Tashev, Dimitra Emmanouilidou
similarity 0.62
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

EEG foundation models are advancing at an unprecedented pace, yet their evaluation is driven by downstream accuracy, which reveals little about whether their predictions rely on physiologically interpretable signal structure. We introduce a set of perturbation probes in two grounding axes: spatial grounding in channel identity and topographic locality, and spectral grounding in oscillatory content and waveform morphology. We apply these probes to five published EEG foundation models across motor-imagery and seizure recordings. Our experiments reveal differences in both representational sensitivity and downstream reliance. Electrode identity may be encoded without influencing downstream classification: permuting LaBraM's positional codes heavily displaced its embeddings yet reduced motor-imagery accuracy by only 1.2 points, while spectral details may be discriminable without producing specific responses to simulated clinical markers, as only REVE exceeded a spectral baseline on this task. These dissociations are hidden in common benchmarks, demonstrating how grounding probes can complement performance-based evaluation by revealing what EEG foundation models encode and what their predictions depend on.

0.09