CS Paper Radar

Envelope Characterizations for Trajectories of the Ćuk Converter

Aleksandra Lekić, Dušan Stipanović

eess.SY ·submitted 2026-10-03 11:38 UTC · v1
unusual

Abstract

In this paper, a complete characterization of the stability and the boundaries of the envelopes for trajectories of the Ćuk converter is provided in the cases of time and state-dependent switching. In particular, difference equations are developed and used to compute boundaries for the system's response envelopes as well as Lyapunov functions to show the system's stability in both continuous and discontinuous regimes of operation. Each case is illustrated by multiple simulations.

Closest papers

Nearest neighbours by meaning across the whole index.

A Small-Gain-Like Framework for Large-Signal Stability Evaluation of Multi-Converter Systems

eess.SY ·2026-08-30 ·Qiannan Qu, Kaiwen Chen, Xin Xiang, Wuhua Li, Yunjie Gu
theory similarity 0.43
Abstract · 13 pages, 10 figures, 4 tables

The increasing penetration of grid-connected converters has greatly altered the large-signal behavior of power systems. Their angle dynamics, shaped by diverse control algorithms and coupled through complex circuit interactions, pose substantial challenges to large-signal stability evaluation of multi-converter systems. To resolve this issue, the small-gain theorem, which characterizes the dissipation capability of interconnected systems (the small-gain-like property) via the individual dissipation capabilities of subsystems, is introduced to investigate transient angle motions in multi-converter systems. A large-signal model involving a set of interconnected relative angle motions is first developed, and the small-gain-like property is then established for multi-converter systems within certain angle limits, which further enables the construction of Lyapunov functions. Based on this, an ellipsoidal forward-invariant region is identified inside the angle-limit region, which serves as an effective estimate of the large-signal stability region for multi-converter systems. The method is further applied to a paralleled system and a four-converter system, where the large-signal stability boundaries are explicitly computed and subsequently validated through experiments. The proposed small-gain-like based large-signal stability evaluation method enables quantitative stability assessment in multi-converter systems with diverse control algorithms, which may provide a scalable framework for large-signal stability evaluation and parameter design in modern power systems.

0.32

Numerical Stability Issues and a Mitigation Method in Switching Events Calculation Considering State Variable Discontinuities for EMT Simulation

eess.SY ·2026-11-08 ·Sheng Lei
similarity 0.42
Abstract · Copyright may be transferred without notice, after which this version may no longer be accessible

Some existing methods for switching events calculation considering state variable discontinuities for EMT simulation can encounter numerical stability issues, either over-stabilizing or destabilizing the studied power systems. This paper documents these issues in detail with a concrete example. The underlying mechanism of the issues are revealed via systematic analysis. A mitigation method for the issues is proposed. The convergence behavior of the method is analyzed. Numerical examples demonstrate the effectiveness of the method. It is observed that the method also helps to improve the accuracy of the simulation results.

0.29

Quantitative Stability Region Estimation of Grid-Forming Inverters with Current Limiting via a State-Dependent Switched Energy Function

eess.SY ·2026-11-11 ·Yifan Zhang, Yang Wu
similarity 0.41
Abstract

With increasing renewable energy integration, grid-forming (GFM) inverters are becoming key components of future power systems. Compared with synchronous generators (SGs), GFM inverters have limited overcurrent capability and require current limiting. This can lead to switching between normal and current-limited operating modes under large disturbances, complicating synchronization dynamics and posing a longstanding challenge to existing transient-stability analysis methods. In this paper, a state-dependent switched (SdS) energy function theory is proposed for transient-stability analysis of GFM inverters with current limiting, whose dynamics can be abstracted as SdS nonlinear systems. Regional energy functions are constructed for individual operating modes and continuously matched at switching interfaces, yielding a continuous piecewise energy function. Hence, the derived conservative estimate of the stability region (region of attraction, ROA) spans different operating regions without prescribing subsequent current limiting activations and releases, a fundamental distinction from conventional methods using signal-mode energy functions. Techniques for incorporating damping energy are extended to the proposed framework to capture damping effects and further reduce the conservatism of the ROA estimates. The methodology applies to GFM inverters with different synchronization control loops and current-limiting strategies. Experiments on a physical GFM inverter under various grid contingencies validate the proposed quantitative transient stability assessment.

0.22

Harmonic Stability of Power Systems: A Control-Theoretic Definition and Assessment Criteria

eess.SY ·2026-08-20 ·N. Bhoir, A. Sarkar, J. E. Machado, J. Schiffer
similarity 0.41
Abstract

Harmonic interactions have become a defining dynamic stability phenomenon in converter-based power systems (CBPSs). However, a formalization of the notion of harmonic stability in the context of nonlinear dynamical systems is not available thus far. In this paper, we propose a definition of harmonic stability formulated as a combination of two standard stability notions, namely, bounded-input bounded-output (BIBO) and internal stability properties with respect to any nominal periodic trajectory. Moreover, we rigorously show that the local harmonic stability of any nominal periodic trajectory of nonlinear CBPSs is implied by the stability properties of its linear time-periodic (LTP) approximation. In addition, to enable computationally tractable stability assessment, we develop a framework based on harmonic state-space (HSS) representations of LTP models. In particular, we provide time-invariant linear matrix inequality (LMI) conditions to certify harmonic stability. The proposed methodology is illustrated on a grid-following converter system, where the HSS-based analysis numerically confirms harmonic stability around the periodic operating trajectory.

0.29

Blackbox Small-Signal Modeling of Grid-Connected Inverters in Asymmetrical Power Grids

eess.SY ·2026-09-01 ·Airan Frances, Dionisio Ramirez, Javier Uceda
top venuehighly cited similarity 0.41
Abstract · 11 pages, 14 figures, IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 38, NO. 10, OCTOBER 2023

Power electronic converters are envisaged to be key enablers of modern electric power distribution systems. Grid-connected three-phase inverters are widely used in Smart Grids and microgrids, but also in standard grids. They provide controllability and dynamic decoupling capabilities, which are fundamental in the integration of renewable sources and storage systems and in specialized applications such as FACTS. Nevertheless, power electronics-based systems can exhibit dynamic interactions, which may lead to power quality issues. Although the electrical model of each element of these systems is important for their system-level analysis, they are rarely available. Blackbox modeling strategies are useful for obtaining behavioral models of commercial electronic converters. Most blackbox modeling strategies are focused on dc-dc electronic converters; however, some works have extended these concepts to three-phase converters by means of the dq framework, under the assumption of symmetrical and balanced conditions. This work proposes a new structure in the sequence domain to represent the dynamic behavior of grid-connected commercial converters in asymmetrical conditions. Experimental tests have been performed on a three-phase inverter to identify its blackbox model and its performance has been validated during an asymmetric voltage sag.

0.82

Barrier Function Control for the Interconnection of DC Electronic Loads to Utility Grid

eess.SY ·2026-10-22 ·Grigoris Michos, Christos K. Verginis
similarity 0.40
Abstract · preprint for paper to appear in IEEE ISGT Europe conference 2026

This paper proposes a nonlinear control law that facilitates the safe integration of DC electronic loads to the utility grid. Specifically, by employing suitable reciprocal barrier functions, it is rigorously proven that the closed-loop system guarantees constrained operation within a desired operating region, despite the influence of fast converter dynamics and fluctuating constant power load demand. This way, the proposed controller guarantees safety of the electronic components from surges in power demand and high transients. The theoretic results are validated in simulation scenarios, where the performance of the proposed controller is compared against the conventional saturated-PI controller. Contrary to the latter, the proposed method guarantees stable and safe operation, enhancing the system robustness.

0.16

Safe Barrier Function Control for Grid-Following Inverters under Weak Grid Conditions

eess.SY ·2026-10-18 ·Grigoris Michos, Christos K. Verginis
similarity 0.40
Abstract · 10 pages

This paper proposes a barrier control approach for the safe regulation of grid-following voltage-source-converters (VSC), operating in weak grid conditions. The proposed controller aims to enhance the transient performance and synchronization properties of the VSC, providing frequency and current limiting guarantees by employing smooth control barrier functions. First, a dynamic model is derived that includes the dynamic state interactions that are omitted in quasi-steady-state approaches, revealing the destabilizing elements both during transient and steady-state performance. Then, it is analytically proven that the proposed control law guarantees frequency limitation and inner current evolution in prescribed safety regions, while counteracting the destabilizing strong coupling between PCC voltage and injected current. In addition, sufficient conditions are formulated that guarantee the stability of the closed-loop system with respect to desired operating points. The theoretic results are verified in simulations of case studies operating in varying grid strength.

0.32

Relative-Degree Wall Restricts Passivity-Based Stability Analysis in Inverter-Dominant Grids

eess.SY ·2026-08-30 ·Xiaoyu Peng, Zhongze Li, Xi Ru, Xinghua Chen, Feng Liu
top venue similarity 0.39
Abstract

This letter reveals a fundamental limitation of passivity-based distributed stability analysis in power systems. Under the standard formulation, passivity certification inherently imposes a relative-degree compatibility constraint that excludes many high-fidelity inverter dynamic models (e.g., those that include electromagnetic transients). Potential extensions of passivity frameworks are discussed to break this limitation.

0.43